Skip to main content
Top
Published in: Diagnostic Pathology 1/2014

Open Access 01-12-2014 | Research

Spectral- and time-domain optical coherence tomography measurements of macular thickness in young myopic eyes

Authors: Lin Liu, Jun Zou, Lili Jia, Jian-guo Yang, Shao-rong Chen

Published in: Diagnostic Pathology | Issue 1/2014

Login to get access

Abstract

Purpose

To evaluate the variation in macular retinal thickness and volume in young Chinese myopic patients using time-domain optical coherence tomography (Stratus TD-OCT) and spectral-domain optical coherence tomography (Cirrus HD-OCT).

Methods

Ninety-two eyes of 92 myopic subjects were recruited in this study. Based upon spherical equivalence (SE), subjects were divided into two groups: the low to moderate myopia group (-0.5 D ≤ SE < -6.0 D), and the high myopia group (SE ≥ -6.0 D). Stratus TD-OCT and Cirrus HD-OCT were used to compare macular retinal thickness and volume between the two groups. Bland–Altman analysis and Pearson correlation were used to measure agreement between the two OCT systems.

Results

Average macular retinal thickness and total macular volume measured by Cirrus HD-OCT and Stratus TD-OCT of the low to moderate myopia group were 283.52 ± 12.14 μm and 245.38 ± 8.55 μm, respectively, and 10.08 ± 0.37 mm3 and 6.85 ± 0.26 mm3, respectively, and the high myopia groups were 269.58 ± 10.72 μm and 235.65 ± 7.54 μm, respectively, and 9.71 ± 0.36 mm3 and 6.52 ± 0.25 mm3, respectively. The measurements of the two OCTs showed that macular retinal thickness of the parafovea was significantly lower in the high myopia group compared with the low to moderate myopia group, except at the fovea (all P-values less than 0.001, except at the fovea). Using the Bland–Altman method and Pearson correlation, measurements of macular thickness in nine macular retinal subfields and total macular volumes showed good agreement between the two OCTs in myopic eyes (all P-values less than 0.001), with better agreement in the low to moderate myopia group than in the high myopia group.

Conclusions

The average macular retinal thickness of the fovea did not vary with myopia, while the total volume and retinal thickness of the parafovea were thinner with increasing myopia. There was good agreement between the two OCTs in myopic eyes in all macular subfields, and the Cirrus HD-OCT system provided thicker macular retinal thickness measurements than the Stratus TD-OCT system.

Virtual slides

Appendix
Available only for authorised users
Literature
1.
go back to reference Bar Dayan Y, Levin A, Morad Y, Grotto I, Ben-David R, Goldberg A, Onn E, Avni I, Levi Y, Benyamini OG: The changing prevalence of myopia in young adults: a 13-year series population-based prevalence surveys. Invest Ophthalmol Vis Sci. 2005, 46 (8): 2760-2765. 10.1167/iovs.04-0260.PubMedCrossRef Bar Dayan Y, Levin A, Morad Y, Grotto I, Ben-David R, Goldberg A, Onn E, Avni I, Levi Y, Benyamini OG: The changing prevalence of myopia in young adults: a 13-year series population-based prevalence surveys. Invest Ophthalmol Vis Sci. 2005, 46 (8): 2760-2765. 10.1167/iovs.04-0260.PubMedCrossRef
2.
go back to reference Wong TY, Foster PJ, Hee J, Ng TP, Tielsch JM, Chew SJ, Johnson GJ, Seah SK: Prevalence and risk factors for refractive errors in adult Chinese in Singapore. Invest Ophthalmol Vis Sci. 2000, 41: 2486-2494.PubMed Wong TY, Foster PJ, Hee J, Ng TP, Tielsch JM, Chew SJ, Johnson GJ, Seah SK: Prevalence and risk factors for refractive errors in adult Chinese in Singapore. Invest Ophthalmol Vis Sci. 2000, 41: 2486-2494.PubMed
3.
go back to reference Grosvenor T: Why is there an epidemic of myopia?. Clin Exp Optom. 2003, 86: 273-275. 10.1111/j.1444-0938.2003.tb03122.x.PubMedCrossRef Grosvenor T: Why is there an epidemic of myopia?. Clin Exp Optom. 2003, 86: 273-275. 10.1111/j.1444-0938.2003.tb03122.x.PubMedCrossRef
4.
go back to reference Lim R, Mitchell P: Cumming RG Refractive associations with cataract: the blue mountains eye study. Invest Ophthalmol Vis Sci. 1999, 40 (12): 3021-3026.PubMed Lim R, Mitchell P: Cumming RG Refractive associations with cataract: the blue mountains eye study. Invest Ophthalmol Vis Sci. 1999, 40 (12): 3021-3026.PubMed
5.
go back to reference Mitchell P, Hourihan F, Sandbach J, Wang JJ: The relationship between glaucoma and myopia: The Blue Mountains Eye Study. Ophthalmology. 1999, 106: 2010-2015. 10.1016/S0161-6420(99)90416-5.PubMedCrossRef Mitchell P, Hourihan F, Sandbach J, Wang JJ: The relationship between glaucoma and myopia: The Blue Mountains Eye Study. Ophthalmology. 1999, 106: 2010-2015. 10.1016/S0161-6420(99)90416-5.PubMedCrossRef
6.
go back to reference Stirpe M, Michels RG: Retinal detachment in highly myopic eyes due to macular holes and epiretinal traction. Retina. 1990, 10 (2): 113-114. 10.1097/00006982-199004000-00004.PubMedCrossRef Stirpe M, Michels RG: Retinal detachment in highly myopic eyes due to macular holes and epiretinal traction. Retina. 1990, 10 (2): 113-114. 10.1097/00006982-199004000-00004.PubMedCrossRef
7.
go back to reference Saw SM, Gazzard G, Shih-Yen EC, Chua WH: Myopia and associated pathological complications. Ophthalmic Physiol Opt. 2005, 25 (5): 381-391. 10.1111/j.1475-1313.2005.00298.x.PubMedCrossRef Saw SM, Gazzard G, Shih-Yen EC, Chua WH: Myopia and associated pathological complications. Ophthalmic Physiol Opt. 2005, 25 (5): 381-391. 10.1111/j.1475-1313.2005.00298.x.PubMedCrossRef
8.
go back to reference Wang FR: Current status and problems in the study of myopia. Zhong hua Yan Ke Za Zhi. 2003, 39 (6): 381-384. Wang FR: Current status and problems in the study of myopia. Zhong hua Yan Ke Za Zhi. 2003, 39 (6): 381-384.
9.
go back to reference Yanoff M, Fine BS: Ocular Pathology: A Text and Atlas. 1989, Philadelphia: JB Lippincott, 408-3 Yanoff M, Fine BS: Ocular Pathology: A Text and Atlas. 1989, Philadelphia: JB Lippincott, 408-3
10.
go back to reference van Velthoven ME, Faber DJ, Verbraak FD, van Leeuwen TG, de Smet MD: Recent developments in optical coherence tomography for imaging the retina. Progr Retin Eye Res. 2007, 26: 57-77. 10.1016/j.preteyeres.2006.10.002.CrossRef van Velthoven ME, Faber DJ, Verbraak FD, van Leeuwen TG, de Smet MD: Recent developments in optical coherence tomography for imaging the retina. Progr Retin Eye Res. 2007, 26: 57-77. 10.1016/j.preteyeres.2006.10.002.CrossRef
11.
go back to reference Chen TC, Cense B, Pierce MC, Nassif N, Park BH, Yun SH, White BR, Bouma BE, Tearney GJ, de Boer JF: Spectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging. Arch Ophthalmol. 2005, 123: 1715-1720. 10.1001/archopht.123.12.1715.PubMedCrossRef Chen TC, Cense B, Pierce MC, Nassif N, Park BH, Yun SH, White BR, Bouma BE, Tearney GJ, de Boer JF: Spectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging. Arch Ophthalmol. 2005, 123: 1715-1720. 10.1001/archopht.123.12.1715.PubMedCrossRef
12.
go back to reference Paunescu LA, Schuman JS, Price LL, Stark PC, Beaton S, Ishikawa H, Wollstein G, Fujimoto JG: Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using Stratus OCT. Invest Ophthalmol Vis Sci. 2004, 45 (6): 1716-1724. 10.1167/iovs.03-0514.PubMedPubMedCentralCrossRef Paunescu LA, Schuman JS, Price LL, Stark PC, Beaton S, Ishikawa H, Wollstein G, Fujimoto JG: Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using Stratus OCT. Invest Ophthalmol Vis Sci. 2004, 45 (6): 1716-1724. 10.1167/iovs.03-0514.PubMedPubMedCentralCrossRef
13.
go back to reference Ma XY, Yan L, He L, He D, Lu H: Ocular fundus manifestation of two patients following long-term chloroquine therapy: a case report. Diagn Pathol. 2010, 5: 20-10.1186/1746-1596-5-20.PubMedPubMedCentralCrossRef Ma XY, Yan L, He L, He D, Lu H: Ocular fundus manifestation of two patients following long-term chloroquine therapy: a case report. Diagn Pathol. 2010, 5: 20-10.1186/1746-1596-5-20.PubMedPubMedCentralCrossRef
14.
go back to reference Onal S, Tugal-Tutkun I, Neri P, P Herbort C: Optical coherence tomography imaging in uveitis. Int Ophthalmol. 2013, 7: 9- Onal S, Tugal-Tutkun I, Neri P, P Herbort C: Optical coherence tomography imaging in uveitis. Int Ophthalmol. 2013, 7: 9-
15.
go back to reference Liu L, Zou J, Huang H, Yang JG, Chen SR: The influence of corneal astigmatism on retinal nerve fiber layer thickness and optic nerve head parameter measurements by spectral-domain optical coherence tomography. Diagn Pathol. 2012, 7: 55-10.1186/1746-1596-7-55.PubMedPubMedCentralCrossRef Liu L, Zou J, Huang H, Yang JG, Chen SR: The influence of corneal astigmatism on retinal nerve fiber layer thickness and optic nerve head parameter measurements by spectral-domain optical coherence tomography. Diagn Pathol. 2012, 7: 55-10.1186/1746-1596-7-55.PubMedPubMedCentralCrossRef
16.
go back to reference Giammaria D, Ioni A, Bartoli B, Cofini V, Pellegrini G, Giannotti B: Comparison of macular thickness measurements between time-domain and spectral-domain optical coherence tomographies in eyes with and without macular abnormalities. Retina. 2011, 31 (4): 707-716.PubMed Giammaria D, Ioni A, Bartoli B, Cofini V, Pellegrini G, Giannotti B: Comparison of macular thickness measurements between time-domain and spectral-domain optical coherence tomographies in eyes with and without macular abnormalities. Retina. 2011, 31 (4): 707-716.PubMed
17.
go back to reference Kakinoki M, Sawada O, Sawada T, Kawamura H, Ohji M: Comparison of macular thickness between Cirrus HD-OCT and Stratus OCT. Ophthalmic Surg Lasers Imaging. 2009, 40 (2): 135-140. 10.3928/15428877-20090301-09.PubMedCrossRef Kakinoki M, Sawada O, Sawada T, Kawamura H, Ohji M: Comparison of macular thickness between Cirrus HD-OCT and Stratus OCT. Ophthalmic Surg Lasers Imaging. 2009, 40 (2): 135-140. 10.3928/15428877-20090301-09.PubMedCrossRef
18.
go back to reference Han IC, Jaffe GJ: Comparison of spectral-and time-domain optical coherence tomography for retinal thickness measurements in healthy and diseased eyes. Am J Ophthalmol. 2009, 147 (5): 847-858. 10.1016/j.ajo.2008.11.019. 858.e1PubMedCrossRef Han IC, Jaffe GJ: Comparison of spectral-and time-domain optical coherence tomography for retinal thickness measurements in healthy and diseased eyes. Am J Ophthalmol. 2009, 147 (5): 847-858. 10.1016/j.ajo.2008.11.019. 858.e1PubMedCrossRef
19.
go back to reference Shin HJ, Cho BJ: Comparison of retinal nerve fiber layer thickness between Stratus and Spectralis OCT. Korean J Ophthalmol. 2011, 25 (3): 166-173. 10.3341/kjo.2011.25.3.166.PubMedPubMedCentralCrossRef Shin HJ, Cho BJ: Comparison of retinal nerve fiber layer thickness between Stratus and Spectralis OCT. Korean J Ophthalmol. 2011, 25 (3): 166-173. 10.3341/kjo.2011.25.3.166.PubMedPubMedCentralCrossRef
20.
go back to reference Lim MC, Hoh ST, Foster PJ, Lim TH, Chew SJ, Seah SK, Aung T: Use of optical coherence tomography to assess variations in macular retinal thickness in myopia. Invest Ophthalmol Vis Sci. 2005, 46 (3): 974-978. 10.1167/iovs.04-0828.PubMedCrossRef Lim MC, Hoh ST, Foster PJ, Lim TH, Chew SJ, Seah SK, Aung T: Use of optical coherence tomography to assess variations in macular retinal thickness in myopia. Invest Ophthalmol Vis Sci. 2005, 46 (3): 974-978. 10.1167/iovs.04-0828.PubMedCrossRef
21.
go back to reference Zhong XW, Ge J, Chen XL, Nie HH, Huang J: Comparison of retinal morphology and ultrastructure in defocus-induced myopia and form-deprivation myopia in rhesus monkeys. Zhonghua Yan Ke Za Zhi. 2005, 41 (7): 625-630.PubMed Zhong XW, Ge J, Chen XL, Nie HH, Huang J: Comparison of retinal morphology and ultrastructure in defocus-induced myopia and form-deprivation myopia in rhesus monkeys. Zhonghua Yan Ke Za Zhi. 2005, 41 (7): 625-630.PubMed
Metadata
Title
Spectral- and time-domain optical coherence tomography measurements of macular thickness in young myopic eyes
Authors
Lin Liu
Jun Zou
Lili Jia
Jian-guo Yang
Shao-rong Chen
Publication date
01-12-2014
Publisher
BioMed Central
Published in
Diagnostic Pathology / Issue 1/2014
Electronic ISSN: 1746-1596
DOI
https://doi.org/10.1186/1746-1596-9-38

Other articles of this Issue 1/2014

Diagnostic Pathology 1/2014 Go to the issue