Skip to main content
Top
Published in: Journal of Cardiovascular Magnetic Resonance 1/2015

Open Access 01-12-2015 | Technologist presentation

Turning up the adenosine turns off the spleen

Authors: Michelle Walkden, Jennifer Bryant, Ausami Abbas, Stephen Harden, James Shambrook, Charles Peebles

Published in: Journal of Cardiovascular Magnetic Resonance | Special Issue 1/2015

Login to get access

Excerpt

Adenosine as a stress agent is well tolerated and has a good safety profile but occasionally when administered at 140mg/kg/min it fails to produce a haemodynamic or symptomatic response. …
Literature
1.
go back to reference Weerackody R, Burchell T, Mohiddin S, Crake T, Mathur A, Westwood M, Davies C: High dose adenosine stress perfusion cardiovascular. Journal of Cardiovascular Magnetic Resonance. 2010, 12 (Suppl 1): P222-10.1186/1532-429X-12-S1-P222.CrossRef Weerackody R, Burchell T, Mohiddin S, Crake T, Mathur A, Westwood M, Davies C: High dose adenosine stress perfusion cardiovascular. Journal of Cardiovascular Magnetic Resonance. 2010, 12 (Suppl 1): P222-10.1186/1532-429X-12-S1-P222.CrossRef
2.
go back to reference Karamitsos T, Ntusi N, Francis J, Holloway C, Myerson S, Neubauer : Feasibility and safety of high-dose adenosine perfusion cardiovascular magnetic resonance. Journal of Cardiovascular Magnetic Resonance. 2010, 12: 66-10.1186/1532-429X-12-66.PubMedCentralCrossRefPubMed Karamitsos T, Ntusi N, Francis J, Holloway C, Myerson S, Neubauer : Feasibility and safety of high-dose adenosine perfusion cardiovascular magnetic resonance. Journal of Cardiovascular Magnetic Resonance. 2010, 12: 66-10.1186/1532-429X-12-66.PubMedCentralCrossRefPubMed
3.
go back to reference Manisty C, Ripley D, Captur G, Peebles C, Wong T, Schelbert E, Herrey A, Greenwood J, Moon J: ‘Splenic switch-off' to detect adenosine understress; a novel method to improve test sensitivity. Journal of Cardiovascular Magnetic Resonance. 2014, 16 (Suppl 1): O1-10.1186/1532-429X-16-S1-O1.PubMedCentralCrossRef Manisty C, Ripley D, Captur G, Peebles C, Wong T, Schelbert E, Herrey A, Greenwood J, Moon J: ‘Splenic switch-off' to detect adenosine understress; a novel method to improve test sensitivity. Journal of Cardiovascular Magnetic Resonance. 2014, 16 (Suppl 1): O1-10.1186/1532-429X-16-S1-O1.PubMedCentralCrossRef
Metadata
Title
Turning up the adenosine turns off the spleen
Authors
Michelle Walkden
Jennifer Bryant
Ausami Abbas
Stephen Harden
James Shambrook
Charles Peebles
Publication date
01-12-2015
Publisher
BioMed Central
DOI
https://doi.org/10.1186/1532-429X-17-S1-T1

Other articles of this Special Issue 1/2015

Journal of Cardiovascular Magnetic Resonance 1/2015 Go to the issue