Skip to main content
Top
Published in: Journal of Cardiovascular Magnetic Resonance 1/2010

Open Access 01-12-2010 | Research

Reproducibility of adenosine stress cardiovascular magnetic resonance in multi-vessel symptomatic coronary artery disease

Authors: Sharon Chih, Peter S Macdonald, Michael P Feneley, Matthew Law, Robert M Graham, Jane A McCrohon

Published in: Journal of Cardiovascular Magnetic Resonance | Issue 1/2010

Login to get access

Abstract

Purpose

First-pass perfusion cardiovascular magnetic resonance (CMR) is increasingly being utilized in both clinical practice and research. However, the reproducibility of this technique remains incompletely evaluated, particularly in patients with severe coronary artery disease (CAD). The purpose of this study was to determine the inter-study reproducibility of adenosine stress CMR in patients with symptomatic multi-vessel CAD and those at low risk for CAD.

Methods

Twenty patients (10 with CAD, 10 low risk CAD) underwent two CMR scans 8 ± 2 days apart. Basal, mid and apical left ventricular short axis slices were acquired using gadolinium 0.05 mmol/kg at peak stress (adenosine, 140 μ/kg/min, 4 min) and rest. Myocardial perfusion was evaluated qualitatively by assessing the number of ischemic segments, and semi-quantitatively by determining the myocardial perfusion reserve index (MPRi) using a normalized upslope method. Inter-study and observer reproducibility were assessed--the latter being defined by the coefficient of variation (CoV), which was calculated from the standard deviation of the differences of the measurements, divided by the mean. Additionally, the percentage of myocardial segments with perfect agreement and inter- and intra-observer MPRi correlation between studies, were also determined.

Results

The CoV for the number of ischemic segments was 31% with a mean difference of -0.15 ± 0.88 segments and 91% perfect agreement between studies. MPRi was lower in patients with CAD (1.13 ± 0.21) compared to those with low risk CAD (1.59 ± 0.58), p = 0.02. The reproducibility of MPRi was 19% with no significant difference between patients with CAD and those with low risk CAD (p = 0.850). Observer reproducibility for MPRi was high: inter-observer CoV 9%, r = 0.93 and intra-observer CoV 5%, r = 0.94. For trials using perfusion CMR as an endpoint, an estimated sample size of 12 subjects would be required to detect a two-segment change in the number of ischemic segments (power 0.9, α 0.05).

Conclusions

Adenosine stress CMR, by qualitative and semi-quantitative normalized upslope analyses are reproducible techniques in both patients with multi-vessel CAD and those without known CAD. The robust inter-study reproducibility of perfusion CMR supports its clinical and research application.
Appendix
Available only for authorised users
Literature
1.
go back to reference Nandalur KR, Dwamena BA, Choudhri AF, Nandalur MR, Carlos RC: Diagnostic Performance of Stress Cardiac Magnetic Resonance Imaging in the Detection of Coronary Artery Disease: A Meta-Analysis. Journal of the American College of Cardiology. 2007, 50: 1343-1353. 10.1016/j.jacc.2007.06.030.CrossRefPubMed Nandalur KR, Dwamena BA, Choudhri AF, Nandalur MR, Carlos RC: Diagnostic Performance of Stress Cardiac Magnetic Resonance Imaging in the Detection of Coronary Artery Disease: A Meta-Analysis. Journal of the American College of Cardiology. 2007, 50: 1343-1353. 10.1016/j.jacc.2007.06.030.CrossRefPubMed
2.
go back to reference Ishida N, Sakuma H, Motoyasu M, Okinaka T, Isaka N, Nakano T, Takeda K: Noninfarcted myocardium: correlation between dynamic first-pass contrast-enhanced myocardial MR imaging and quantitative coronary angiography. Radiology. 2003, 229: 209-216. 10.1148/radiol.2291021118.CrossRefPubMed Ishida N, Sakuma H, Motoyasu M, Okinaka T, Isaka N, Nakano T, Takeda K: Noninfarcted myocardium: correlation between dynamic first-pass contrast-enhanced myocardial MR imaging and quantitative coronary angiography. Radiology. 2003, 229: 209-216. 10.1148/radiol.2291021118.CrossRefPubMed
3.
go back to reference Sakuma H, Suzawa N, Ichikawa Y, Makino K, Hirano T, Kitagawa K, Takeda K: Diagnostic accuracy of stress first-pass contrast-enhanced myocardial perfusion MRI compared with stress myocardial perfusion scintigraphy. AJR Am J Roentgenol. 2005, 185: 95-102.CrossRefPubMed Sakuma H, Suzawa N, Ichikawa Y, Makino K, Hirano T, Kitagawa K, Takeda K: Diagnostic accuracy of stress first-pass contrast-enhanced myocardial perfusion MRI compared with stress myocardial perfusion scintigraphy. AJR Am J Roentgenol. 2005, 185: 95-102.CrossRefPubMed
4.
go back to reference Schwitter J, Wacker CM, van Rossum AC, Lombardi M, Al-Saadi N, Ahlstrom H, Dill T, Larsson HBW, Flamm SD, Marquardt M, Johansson L: MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial. Eur Heart J. 2008, 29: 480-489. 10.1093/eurheartj/ehm617.CrossRefPubMed Schwitter J, Wacker CM, van Rossum AC, Lombardi M, Al-Saadi N, Ahlstrom H, Dill T, Larsson HBW, Flamm SD, Marquardt M, Johansson L: MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial. Eur Heart J. 2008, 29: 480-489. 10.1093/eurheartj/ehm617.CrossRefPubMed
5.
go back to reference Jahnke C, Nagel E, Gebker R, Kokocinski T, Kelle S, Manka R, Fleck E, Paetsch I: Prognostic Value of Cardiac Magnetic Resonance Stress Tests: Adenosine Stress Perfusion and Dobutamine Stress Wall Motion Imaging. Circulation. 2007, 115: 1769-1776. 10.1161/CIRCULATIONAHA.106.652016.CrossRefPubMed Jahnke C, Nagel E, Gebker R, Kokocinski T, Kelle S, Manka R, Fleck E, Paetsch I: Prognostic Value of Cardiac Magnetic Resonance Stress Tests: Adenosine Stress Perfusion and Dobutamine Stress Wall Motion Imaging. Circulation. 2007, 115: 1769-1776. 10.1161/CIRCULATIONAHA.106.652016.CrossRefPubMed
6.
go back to reference Ingkanisorn WP, Kwong RY, Bohme NS, Geller NL, Rhoads KL, Dyke CK, Paterson DI, Syed MA, Aletras AH, Arai AE: Prognosis of negative adenosine stress magnetic resonance in patients presenting to an emergency department with chest pain. J Am Coll Cardiol. 2006, 47: 1427-1432. 10.1016/j.jacc.2005.11.059.CrossRefPubMed Ingkanisorn WP, Kwong RY, Bohme NS, Geller NL, Rhoads KL, Dyke CK, Paterson DI, Syed MA, Aletras AH, Arai AE: Prognosis of negative adenosine stress magnetic resonance in patients presenting to an emergency department with chest pain. J Am Coll Cardiol. 2006, 47: 1427-1432. 10.1016/j.jacc.2005.11.059.CrossRefPubMed
7.
go back to reference Elkington A, Gatehouse P, Ablitt NA, Yang G, Firmin DN, Pennell DJ: Interstudy reproducibility of quantitative perfusion cardiovascular magnetic resonance. J Cardiovasc Magn reson. 2005, 7: 815-822. 10.1080/10976640500287877.CrossRefPubMed Elkington A, Gatehouse P, Ablitt NA, Yang G, Firmin DN, Pennell DJ: Interstudy reproducibility of quantitative perfusion cardiovascular magnetic resonance. J Cardiovasc Magn reson. 2005, 7: 815-822. 10.1080/10976640500287877.CrossRefPubMed
8.
go back to reference Muhling OM, Dickson ME, Zenovich A, Huang Y, Wilson BV, Wilson RF, Anand IS, Seethamraju RT, Jerosch-Herold M, Wilke NM: Quantitative magnetic resonance first-pass perfusion analysis: inter- and intraobserver agreement. J Cardiovasc Magn Reson. 2001, 3: 247-256. 10.1081/JCMR-100107473.CrossRefPubMed Muhling OM, Dickson ME, Zenovich A, Huang Y, Wilson BV, Wilson RF, Anand IS, Seethamraju RT, Jerosch-Herold M, Wilke NM: Quantitative magnetic resonance first-pass perfusion analysis: inter- and intraobserver agreement. J Cardiovasc Magn Reson. 2001, 3: 247-256. 10.1081/JCMR-100107473.CrossRefPubMed
9.
go back to reference Syed MA, Paterson DI, Ingkanisorn PW, Rhoads KL: Reproducibility and inter-observer variability of dobutamine stress CMR in patients with severe coronary disease: implications for clinical research. Journal of Cardiovascular Magnetic Resonance. 2005, 7: 763-768. 10.1080/10976640500287414.CrossRefPubMed Syed MA, Paterson DI, Ingkanisorn PW, Rhoads KL: Reproducibility and inter-observer variability of dobutamine stress CMR in patients with severe coronary disease: implications for clinical research. Journal of Cardiovascular Magnetic Resonance. 2005, 7: 763-768. 10.1080/10976640500287414.CrossRefPubMed
10.
go back to reference Wilson PW, D'Agostino RB, Levy D, Belanger AM, Silbershatz H, Kannel WB: Prediction of coronary heart disease using risk factor categories. Circulation. 1998, 97: 1837-1847.CrossRefPubMed Wilson PW, D'Agostino RB, Levy D, Belanger AM, Silbershatz H, Kannel WB: Prediction of coronary heart disease using risk factor categories. Circulation. 1998, 97: 1837-1847.CrossRefPubMed
11.
go back to reference Grothues F, Smith GC, Moon JCC, Bellenger NG, Collins P, Klein HU, Pennell DJ: Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. The American Journal of Cardiology. 2002, 90: 29-34. 10.1016/S0002-9149(02)02381-0.CrossRefPubMed Grothues F, Smith GC, Moon JCC, Bellenger NG, Collins P, Klein HU, Pennell DJ: Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. The American Journal of Cardiology. 2002, 90: 29-34. 10.1016/S0002-9149(02)02381-0.CrossRefPubMed
12.
go back to reference Bellenger NG, Burgess MI, Ray SG, Lahiri A, Coats AJS, Cleland JGF, Pennell DJ: Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance. Are they interchangeable?. Eur Heart J. 2000, 21: 1387-1396. 10.1053/euhj.2000.2011.CrossRefPubMed Bellenger NG, Burgess MI, Ray SG, Lahiri A, Coats AJS, Cleland JGF, Pennell DJ: Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance. Are they interchangeable?. Eur Heart J. 2000, 21: 1387-1396. 10.1053/euhj.2000.2011.CrossRefPubMed
13.
go back to reference Al-Saadi N, Nagel E, Gross M, Bornstedt A, Schnackenburg B, Klein C, Klimek W, Oswald H, Fleck E: Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance. Circulation. 2000, 101: 1379-1383.CrossRefPubMed Al-Saadi N, Nagel E, Gross M, Bornstedt A, Schnackenburg B, Klein C, Klimek W, Oswald H, Fleck E: Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance. Circulation. 2000, 101: 1379-1383.CrossRefPubMed
14.
go back to reference Costa MA, Shoemaker S, Futamatsu H, Klassen C, Angiolillo DJ, Nguyen M, Siuciak A, Gilmore P, Zenni MM, Guzman L, Bass TA, Wilke N: Quantitative Magnetic Resonance Perfusion Imaging Detects Anatomic and Physiologic Coronary Artery Disease as Measured by Coronary Angiography and Fractional Flow Reserve. J Am Coll Cardiol. 2007, 50: 514-522. 10.1016/j.jacc.2007.04.053.CrossRefPubMed Costa MA, Shoemaker S, Futamatsu H, Klassen C, Angiolillo DJ, Nguyen M, Siuciak A, Gilmore P, Zenni MM, Guzman L, Bass TA, Wilke N: Quantitative Magnetic Resonance Perfusion Imaging Detects Anatomic and Physiologic Coronary Artery Disease as Measured by Coronary Angiography and Fractional Flow Reserve. J Am Coll Cardiol. 2007, 50: 514-522. 10.1016/j.jacc.2007.04.053.CrossRefPubMed
Metadata
Title
Reproducibility of adenosine stress cardiovascular magnetic resonance in multi-vessel symptomatic coronary artery disease
Authors
Sharon Chih
Peter S Macdonald
Michael P Feneley
Matthew Law
Robert M Graham
Jane A McCrohon
Publication date
01-12-2010
Publisher
BioMed Central
Published in
Journal of Cardiovascular Magnetic Resonance / Issue 1/2010
Electronic ISSN: 1532-429X
DOI
https://doi.org/10.1186/1532-429X-12-42

Other articles of this Issue 1/2010

Journal of Cardiovascular Magnetic Resonance 1/2010 Go to the issue