Skip to main content
Top
Published in: Journal of Cardiovascular Magnetic Resonance 1/2008

Open Access 01-12-2008 | Research

Resting myocardial perfusion quantification with CMR arterial spin labeling at 1.5 T and 3.0 T

Authors: Benjamin E Northrup, Kyle S McCommis, Haosen Zhang, Shuddhadeb Ray, Pamela K Woodard, Robert J Gropler, Jie Zheng

Published in: Journal of Cardiovascular Magnetic Resonance | Issue 1/2008

Login to get access

Abstract

Background

The magnetic resonance technique of arterial spin labeling (ASL) allows myocardial perfusion to be quantified without the use of a contrast agent. This study aimed to use a modified ASL technique and T1 regression algorithm, previously validated in canine models, to calculate myocardial blood flow (MBF) in normal human subjects and to compare the accuracy and repeatability of this calculation at 1.5 T and 3.0 T. A computer simulation was performed and compared with experimental findings.

Results

Eight subjects were imaged, with scans at 3.0 T showing significantly higher T1 values (P < 0.001) and signal-to-noise ratios (SNR) (P < 0.002) than scans at 1.5 T. The average MBF was found to be 0.990 ± 0.302 mL/g/min at 1.5 T and 1.058 ± 0.187 mL/g/min at 3.0 T. The repeatability at 3.0 T was improved 43% over that at 1.5 T, although no statistically significant difference was found between the two field strengths. In the simulation, the accuracy and the repeatability of the MBF calculations were 61% and 38% higher, respectively, at 3.0 T than at 1.5 T, but no statistically significant differences were observed. There were no significant differences between the myocardial perfusion data sets obtained from the two independent observers. Additionally, there was a trend toward less variation in the perfusion data from the two observers at 3.0 T as compared to 1.5 T.

Conclusion

This suggests that this ASL technique can be used, preferably at 3.0 T, to quantify myocardial perfusion in humans and with further development could be useful in the clinical setting as an alternative method of perfusion analysis.
Appendix
Available only for authorised users
Literature
1.
go back to reference Wei K, Kaul S: The coronary microcirculation in health and disease. Cardiol Clin. 2004, 22 (2): 221-31. 10.1016/j.ccl.2004.02.005.CrossRefPubMed Wei K, Kaul S: The coronary microcirculation in health and disease. Cardiol Clin. 2004, 22 (2): 221-31. 10.1016/j.ccl.2004.02.005.CrossRefPubMed
2.
go back to reference Zhang H, Shea SM, Park V, Li D, Woodard PK, Gropler RJ, Zheng J: Accurate myocardial T1 measurements: toward quantification of myocardial blood flow with arterial spin labeling. Magn Reson Med. 2005, 53 (5): 1135-42. 10.1002/mrm.20461.CrossRefPubMed Zhang H, Shea SM, Park V, Li D, Woodard PK, Gropler RJ, Zheng J: Accurate myocardial T1 measurements: toward quantification of myocardial blood flow with arterial spin labeling. Magn Reson Med. 2005, 53 (5): 1135-42. 10.1002/mrm.20461.CrossRefPubMed
3.
go back to reference L'Abbate A, Sambuceti G: How to study coronary microvascular dysfunction and its clinical relevance. Ital Heart J. 2002, 3 (4): 230-6.PubMed L'Abbate A, Sambuceti G: How to study coronary microvascular dysfunction and its clinical relevance. Ital Heart J. 2002, 3 (4): 230-6.PubMed
4.
go back to reference Rahimtoola SH: Hibernating myocardium has reduced blood flow at rest that increases with low-dose dobutamine. Circulation. 1996, 94: 3055-61.CrossRefPubMed Rahimtoola SH: Hibernating myocardium has reduced blood flow at rest that increases with low-dose dobutamine. Circulation. 1996, 94: 3055-61.CrossRefPubMed
5.
go back to reference Belle V, Kahler E, Waller C, Rommel E, Voll S, Hiller KH, Bauer WR, Haase A: In vivo quantification of cardiac perfusion in rats using a noninvasive MR spin-labeling method. J Magn Reson Imaging. 1998, 8 (6): 1240-5. 10.1002/jmri.1880080610.CrossRefPubMed Belle V, Kahler E, Waller C, Rommel E, Voll S, Hiller KH, Bauer WR, Haase A: In vivo quantification of cardiac perfusion in rats using a noninvasive MR spin-labeling method. J Magn Reson Imaging. 1998, 8 (6): 1240-5. 10.1002/jmri.1880080610.CrossRefPubMed
6.
go back to reference Kim SG: Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med. 1995, 34 (3): 293-301. 10.1002/mrm.1910340303.CrossRefPubMed Kim SG: Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med. 1995, 34 (3): 293-301. 10.1002/mrm.1910340303.CrossRefPubMed
7.
go back to reference Waller C, Kahler E, Hiller KH, Hu K, Nahrendorf M, Voll S, Haase A, Ertl G, Bauer WR: Myocardial perfusion and intracapillary blood volume in rats at rest and with coronary dilatation: MR imaging in vivo with use of a spin-labeling technique. Radiology. 2000, 215 (1): 189-197.CrossRefPubMed Waller C, Kahler E, Hiller KH, Hu K, Nahrendorf M, Voll S, Haase A, Ertl G, Bauer WR: Myocardial perfusion and intracapillary blood volume in rats at rest and with coronary dilatation: MR imaging in vivo with use of a spin-labeling technique. Radiology. 2000, 215 (1): 189-197.CrossRefPubMed
8.
go back to reference Waller C, Hiller KH, Kahler E, Hu K, Nahrendorf M, Voll S, Haase A, Ertl G, Bauer WR: Serial magnetic resonance imaging of microvascular remodeling in the infracted rat heart. Circulation. 2001, 103 (11): 1564-9.CrossRefPubMed Waller C, Hiller KH, Kahler E, Hu K, Nahrendorf M, Voll S, Haase A, Ertl G, Bauer WR: Serial magnetic resonance imaging of microvascular remodeling in the infracted rat heart. Circulation. 2001, 103 (11): 1564-9.CrossRefPubMed
9.
go back to reference Bauer WR, Hiller KH, Galuppo P, Neubauer S, Köpke J, Haase A, Waller C, Ertl G: Fast high-resolution magnetic resonance imaging demonstrates fractality of myocardial perfusion in microscopic dimensions. Circ Res. 2001, 88 (3): 340-346.CrossRefPubMed Bauer WR, Hiller KH, Galuppo P, Neubauer S, Köpke J, Haase A, Waller C, Ertl G: Fast high-resolution magnetic resonance imaging demonstrates fractality of myocardial perfusion in microscopic dimensions. Circ Res. 2001, 88 (3): 340-346.CrossRefPubMed
10.
go back to reference Wacker CM, Fidler F, Dueren C, Hirn S, Jakob PM, Ertl G, Haase A, Bauer WR: Quantitative assessment of myocardial perfusion with a spin-labeling technique: preliminary results in patients with coronary artery disease. J Magn Reson Imaging. 2003, 18 (5): 555-560. 10.1002/jmri.10386.CrossRefPubMed Wacker CM, Fidler F, Dueren C, Hirn S, Jakob PM, Ertl G, Haase A, Bauer WR: Quantitative assessment of myocardial perfusion with a spin-labeling technique: preliminary results in patients with coronary artery disease. J Magn Reson Imaging. 2003, 18 (5): 555-560. 10.1002/jmri.10386.CrossRefPubMed
11.
go back to reference Bergmann SR, Fox KA, Rand AL, McElvany KD, Welch MJ, Markham J, Sobel BE: Quantification of regional myocardial blood flow in vivo with H215O. Circulation. 1984, 70: 724-733.CrossRefPubMed Bergmann SR, Fox KA, Rand AL, McElvany KD, Welch MJ, Markham J, Sobel BE: Quantification of regional myocardial blood flow in vivo with H215O. Circulation. 1984, 70: 724-733.CrossRefPubMed
12.
go back to reference McCommis KS, Zhang H, Herrero P, Gropler RJ, Zheng J: Feasibility study of myocardial perfusion and oxygenation by noncontrast MRI: comparison with PET study in a canine model. Magn Reson Imaging. 2008, 26: 11-19. 10.1016/j.mri.2007.04.009.PubMedCentralCrossRefPubMed McCommis KS, Zhang H, Herrero P, Gropler RJ, Zheng J: Feasibility study of myocardial perfusion and oxygenation by noncontrast MRI: comparison with PET study in a canine model. Magn Reson Imaging. 2008, 26: 11-19. 10.1016/j.mri.2007.04.009.PubMedCentralCrossRefPubMed
13.
go back to reference Lotz J, Döker R, Noeske R, Schüttert M, Felix R, Galanski M, Gutberlet M, Meyer GP: In vitro validation of phase-contrast flow measurements at 3 T in comparison to 1.5 T: precision, accuracy, and signal-to-noise ratios. J Magn Reson Imaging. 2005, 21: 604-610. 10.1002/jmri.20275.CrossRefPubMed Lotz J, Döker R, Noeske R, Schüttert M, Felix R, Galanski M, Gutberlet M, Meyer GP: In vitro validation of phase-contrast flow measurements at 3 T in comparison to 1.5 T: precision, accuracy, and signal-to-noise ratios. J Magn Reson Imaging. 2005, 21: 604-610. 10.1002/jmri.20275.CrossRefPubMed
14.
15.
go back to reference Merkle EM, Dale BM: Abdominal MRI at 3.0 T: the basics revisited. AJR. 2006, 186: 1524-32. 10.2214/AJR.05.0932.CrossRefPubMed Merkle EM, Dale BM: Abdominal MRI at 3.0 T: the basics revisited. AJR. 2006, 186: 1524-32. 10.2214/AJR.05.0932.CrossRefPubMed
16.
go back to reference Edelstein WA, Glover GH, Hardy CJ, Redington RW: The intrinsic signal-to-noise ratio in NMR imaging. Magn Reson Med. 1986, 3: 604-618. 10.1002/mrm.1910030413.CrossRefPubMed Edelstein WA, Glover GH, Hardy CJ, Redington RW: The intrinsic signal-to-noise ratio in NMR imaging. Magn Reson Med. 1986, 3: 604-618. 10.1002/mrm.1910030413.CrossRefPubMed
17.
go back to reference Schindera ST, Merkle EM, Dale BM, DeLong DM, Nelson RC: Abdominal magnetic resonance imaging at 3.0 T: what is the ultimate gain in signal-to-noise ratio?. Acad Radiol. 2006, 13 (10): 1236-43. 10.1016/j.acra.2006.06.018.CrossRefPubMed Schindera ST, Merkle EM, Dale BM, DeLong DM, Nelson RC: Abdominal magnetic resonance imaging at 3.0 T: what is the ultimate gain in signal-to-noise ratio?. Acad Radiol. 2006, 13 (10): 1236-43. 10.1016/j.acra.2006.06.018.CrossRefPubMed
18.
go back to reference Edelman RR, Manning WJ, Burstein D, Paulin S: Coronary arteries: breath-hold MR angiography. Radiology. 1991, 181 (3): 641-3.CrossRefPubMed Edelman RR, Manning WJ, Burstein D, Paulin S: Coronary arteries: breath-hold MR angiography. Radiology. 1991, 181 (3): 641-3.CrossRefPubMed
19.
go back to reference Zheng J, Li D, Cavagna FM, Harris K, Klocke FJ, Maggioni F, Carr J, Simonetti O, Laub G, Finn JP: Contrast-enhanced coronary MR angiography: relationship between coronary artery delineation and blood T1. J Magn Reson Imaging. 2001, 14: 348-354. 10.1002/jmri.1193.CrossRefPubMed Zheng J, Li D, Cavagna FM, Harris K, Klocke FJ, Maggioni F, Carr J, Simonetti O, Laub G, Finn JP: Contrast-enhanced coronary MR angiography: relationship between coronary artery delineation and blood T1. J Magn Reson Imaging. 2001, 14: 348-354. 10.1002/jmri.1193.CrossRefPubMed
20.
go back to reference Kim HW, Klem I, Kim RJ: Detection of myocardial ischemia by stress perfusion cardiovascular magnetic resonance. Cardiol Clin. 2007, 25 (1): 57-70. 10.1016/j.ccl.2007.02.002.CrossRefPubMed Kim HW, Klem I, Kim RJ: Detection of myocardial ischemia by stress perfusion cardiovascular magnetic resonance. Cardiol Clin. 2007, 25 (1): 57-70. 10.1016/j.ccl.2007.02.002.CrossRefPubMed
21.
go back to reference Nitzche EU, Choi Y, Czermin J, Hoh CK, Huang S-C, Schelbert HR: Noninvasive quantification of myocardial blood flow in humans: a direct comparison of the [13N] ammonia and the [15O] water techniques. Circulation. 1996, 93: 2000-2006.CrossRef Nitzche EU, Choi Y, Czermin J, Hoh CK, Huang S-C, Schelbert HR: Noninvasive quantification of myocardial blood flow in humans: a direct comparison of the [13N] ammonia and the [15O] water techniques. Circulation. 1996, 93: 2000-2006.CrossRef
22.
go back to reference Schepis T, Gaemperli O, Treyer V, Valenta I, Burger C, Koepfli P, Namdar M, Adachi I, Alkadhi H, Kaufmann PA: Absolute quantification of myocardial blood flow 13N-ammonia and 3-dimensional PET. J Nuc Med. 2007, 48 (11): 1783-9. 10.2967/jnumed.107.044099.CrossRef Schepis T, Gaemperli O, Treyer V, Valenta I, Burger C, Koepfli P, Namdar M, Adachi I, Alkadhi H, Kaufmann PA: Absolute quantification of myocardial blood flow 13N-ammonia and 3-dimensional PET. J Nuc Med. 2007, 48 (11): 1783-9. 10.2967/jnumed.107.044099.CrossRef
23.
go back to reference Hsu LY, Rhoads KL, Holly JE, Kellman P, Aletras AH, Arai AE: Quantitative myocardial perfusion analysis with a dual-bolus contrast-enhanced first-pass MRI technique in humans. J Magn Reson Imaging. 2006, 23 (3): 315-22. 10.1002/jmri.20502.CrossRefPubMed Hsu LY, Rhoads KL, Holly JE, Kellman P, Aletras AH, Arai AE: Quantitative myocardial perfusion analysis with a dual-bolus contrast-enhanced first-pass MRI technique in humans. J Magn Reson Imaging. 2006, 23 (3): 315-22. 10.1002/jmri.20502.CrossRefPubMed
24.
go back to reference Holm DA, Sidaros K: Slice profile optimization in arterial spin labeling using presaturation and optimized RF pulses. Magn Reson Imaging. 2006, 24: 1229-1240. 10.1016/j.mri.2006.07.011.CrossRefPubMed Holm DA, Sidaros K: Slice profile optimization in arterial spin labeling using presaturation and optimized RF pulses. Magn Reson Imaging. 2006, 24: 1229-1240. 10.1016/j.mri.2006.07.011.CrossRefPubMed
25.
go back to reference Buxton RB: Quantifying CBF with arterial spin labeling. J Magn Reson Imaging. 2005, 22: 723-726. 10.1002/jmri.20462.CrossRefPubMed Buxton RB: Quantifying CBF with arterial spin labeling. J Magn Reson Imaging. 2005, 22: 723-726. 10.1002/jmri.20462.CrossRefPubMed
26.
go back to reference Pell GS, Lewis DP, Ordidge RJ, Branch CA: TurboFLASH FAIR imaging with optimized inversion and imaging profiles. Magn Reson Med. 2004, 51: 46-54. 10.1002/mrm.10674.CrossRefPubMed Pell GS, Lewis DP, Ordidge RJ, Branch CA: TurboFLASH FAIR imaging with optimized inversion and imaging profiles. Magn Reson Med. 2004, 51: 46-54. 10.1002/mrm.10674.CrossRefPubMed
27.
go back to reference Zhou J, van Zijl PCM: Effect of transit times on quantification of cerebral blood flow by the FAIR T1-difference approach. Magn Reson Med. 1999, 42: 890-4. 10.1002/(SICI)1522-2594(199911)42:5<890::AID-MRM8>3.0.CO;2-8.CrossRefPubMed Zhou J, van Zijl PCM: Effect of transit times on quantification of cerebral blood flow by the FAIR T1-difference approach. Magn Reson Med. 1999, 42: 890-4. 10.1002/(SICI)1522-2594(199911)42:5<890::AID-MRM8>3.0.CO;2-8.CrossRefPubMed
28.
go back to reference Kwong KK, Chesler DA, Weisskoff RM, Donahue KM, Davis TL, Ostergaard L, Campbell TA: MR perfusion studies with T1-weighted echo planar imaging. Magn Reson Med. 1995, 34: 878-887. 10.1002/mrm.1910340613.CrossRefPubMed Kwong KK, Chesler DA, Weisskoff RM, Donahue KM, Davis TL, Ostergaard L, Campbell TA: MR perfusion studies with T1-weighted echo planar imaging. Magn Reson Med. 1995, 34: 878-887. 10.1002/mrm.1910340613.CrossRefPubMed
29.
go back to reference Schwarzbauer C, Morrissey SP, Haase A: Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spin within the detection slice. Magn Reson Med. 1996, 35: 540-546.CrossRefPubMed Schwarzbauer C, Morrissey SP, Haase A: Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spin within the detection slice. Magn Reson Med. 1996, 35: 540-546.CrossRefPubMed
30.
go back to reference Yang Y, Frank JA, Hou L, Ye FQ, McLaughlin AC, Duyn JH: Multislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling. Magn Reson Med. 1998, 39: 825-832. 10.1002/mrm.1910390520.CrossRefPubMed Yang Y, Frank JA, Hou L, Ye FQ, McLaughlin AC, Duyn JH: Multislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling. Magn Reson Med. 1998, 39: 825-832. 10.1002/mrm.1910390520.CrossRefPubMed
31.
go back to reference Zhou J, Mori S, van Zijl PCM: FAIR excluding radiation damping (FAIRER). Magn Reson Med. 1998, 40: 712-9. 10.1002/mrm.1910400511.CrossRefPubMed Zhou J, Mori S, van Zijl PCM: FAIR excluding radiation damping (FAIRER). Magn Reson Med. 1998, 40: 712-9. 10.1002/mrm.1910400511.CrossRefPubMed
32.
go back to reference Helpern JA, Branch CA, Yongbi MN, Huang NC: Perfusion imaging by uninverted flow-sensitive alternating inversion recovery (UNFAIR). Magn Reson Imaging. 1997, 15: 135-139. 10.1016/S0730-725X(96)00353-0.CrossRefPubMed Helpern JA, Branch CA, Yongbi MN, Huang NC: Perfusion imaging by uninverted flow-sensitive alternating inversion recovery (UNFAIR). Magn Reson Imaging. 1997, 15: 135-139. 10.1016/S0730-725X(96)00353-0.CrossRefPubMed
33.
go back to reference Zhou J, van Zijl PCM: Perfusion imaging using FAIR with a short predelay. Magn Reson Med. 1999, 41: 1099-1107. 10.1002/(SICI)1522-2594(199906)41:6<1099::AID-MRM5>3.0.CO;2-G.CrossRefPubMed Zhou J, van Zijl PCM: Perfusion imaging using FAIR with a short predelay. Magn Reson Med. 1999, 41: 1099-1107. 10.1002/(SICI)1522-2594(199906)41:6<1099::AID-MRM5>3.0.CO;2-G.CrossRefPubMed
34.
go back to reference Frank LR, Wong EC, Buxton RB: Slice profile effects in adiabatic inversion: application to multislice perfusion imaging. Magn Reson Med. 1997, 38: 558-564. 10.1002/mrm.1910380409.CrossRefPubMed Frank LR, Wong EC, Buxton RB: Slice profile effects in adiabatic inversion: application to multislice perfusion imaging. Magn Reson Med. 1997, 38: 558-564. 10.1002/mrm.1910380409.CrossRefPubMed
Metadata
Title
Resting myocardial perfusion quantification with CMR arterial spin labeling at 1.5 T and 3.0 T
Authors
Benjamin E Northrup
Kyle S McCommis
Haosen Zhang
Shuddhadeb Ray
Pamela K Woodard
Robert J Gropler
Jie Zheng
Publication date
01-12-2008
Publisher
BioMed Central
Published in
Journal of Cardiovascular Magnetic Resonance / Issue 1/2008
Electronic ISSN: 1532-429X
DOI
https://doi.org/10.1186/1532-429X-10-53

Other articles of this Issue 1/2008

Journal of Cardiovascular Magnetic Resonance 1/2008 Go to the issue