Skip to main content
Top
Published in: Journal of Cardiovascular Magnetic Resonance 1/2008

Open Access 01-12-2008 | Research

Measurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSE

Authors: Neil Maredia, Sebastian Kozerke, Abdul Larghat, Nik Abidin, John P Greenwood, Peter Boesiger, Sven Plein

Published in: Journal of Cardiovascular Magnetic Resonance | Issue 1/2008

Login to get access

Abstract

Aim

To compare three-dimensional (3D) k-t sensitivity encoded (k-t SENSE) cine cardiovascular magnetic resonance (CMR), before and after contrast administration, against standard 2D imaging for the assessment of left ventricular volumes and mass.

Method

Twenty-six subjects (14 volunteers, 12 patients) underwent multiple breathhold 2D balanced turbo-field echo cine CMR in addition to k-t SENSE accelerated 3D imaging (acceleration factor 5; 5× k-t SENSE), performed before and after administration of a high-relaxivity gadolinium-based contrast agent (Gadobutrolum). k-t acceleration factors of 7 and 10 were also assessed in six volunteers. Left ventricular end diastolic volume (EDV), end systolic volume (ESV), mass, and ejection fraction (EF) were calculated for each method.

Results

There was at least moderate agreement between the EDV, ESV, mass and EF calculated by 2D and 3D 5× k-t SENSE methods before contrast (concordance coefficients 0.92, 0.95, 0.97, 0.92, respectively). Agreement improved following contrast (concordance coefficients 0.97, 0.99, 0.98, 0.93, respectively). The 3D method underestimated all parameters compared to 2D (mean bias pre-contrast 6.1 ml, 0.6 ml, 3.5 g, 2.0% respectively). 3D image quality scores were significantly poorer than 2D, showing a non-significant trend to improvement following contrast administration. Parameters derived with k-t acceleration factors of 7 and 10 showed poorer agreement with 2D values.

Conclusion

Left ventricular volumes and mass are reliably assessed using 3D 5× k-t SENSE accelerated CMR. Contrast administration further improves agreement between 5× k-t SENSE and 2D-derived measurements. k-t acceleration factors greater than 5, though feasible, produce poorer agreement with 2D values.
Appendix
Available only for authorised users
Literature
1.
go back to reference Semelka RC, Tomei E, Wagner S, Mayo J, Caputo G, O'Sullivan M, Parmley WW, Chatterjee K, Wolfe C, Higgins CB: Interstudy reproducibility of dimensional and functional measurements between cine magnetic resonance studies in the morphologically abnormal left ventricle. Am Heart J. 1990, 119 (6): 1367-1373. 10.1016/S0002-8703(05)80187-5.CrossRefPubMed Semelka RC, Tomei E, Wagner S, Mayo J, Caputo G, O'Sullivan M, Parmley WW, Chatterjee K, Wolfe C, Higgins CB: Interstudy reproducibility of dimensional and functional measurements between cine magnetic resonance studies in the morphologically abnormal left ventricle. Am Heart J. 1990, 119 (6): 1367-1373. 10.1016/S0002-8703(05)80187-5.CrossRefPubMed
2.
go back to reference Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF: MR Evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology. 2001, 219 (1): 264-269.CrossRefPubMed Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF: MR Evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology. 2001, 219 (1): 264-269.CrossRefPubMed
3.
go back to reference Lorenz CH, Walker ES, Morgan VL, Klein SS, Graham TP: Normal human right and left ventricular mass, systolic function and gender differences by cine magnetic resonance imaging. J Cardiovasc Magn Reson. 1999, 1 (1): 7-21. 10.3109/10976649909080829.CrossRefPubMed Lorenz CH, Walker ES, Morgan VL, Klein SS, Graham TP: Normal human right and left ventricular mass, systolic function and gender differences by cine magnetic resonance imaging. J Cardiovasc Magn Reson. 1999, 1 (1): 7-21. 10.3109/10976649909080829.CrossRefPubMed
4.
go back to reference Alfakih K, Plein S, Thiele H, Jones T, Ridgway JP, Sivananthan MU: Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences. J Magn Reson Imaging. 2003, 17 (3): 323-329. 10.1002/jmri.10262.CrossRefPubMed Alfakih K, Plein S, Thiele H, Jones T, Ridgway JP, Sivananthan MU: Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences. J Magn Reson Imaging. 2003, 17 (3): 323-329. 10.1002/jmri.10262.CrossRefPubMed
5.
go back to reference Alfakih K, Plein S, Bloomer T, Jones T, Ridgway J, Sivananthan M: Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging. J Magn Reson Imaging. 2003, 18 (1): 25-32. 10.1002/jmri.10329.CrossRefPubMed Alfakih K, Plein S, Bloomer T, Jones T, Ridgway J, Sivananthan M: Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging. J Magn Reson Imaging. 2003, 18 (1): 25-32. 10.1002/jmri.10329.CrossRefPubMed
6.
go back to reference Bloomer TN, Plein S, Radjenovic A, Higgins DM, Jones TR, Ridgway JP, Sivananthan MU: Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle. J Magn Reson Imaging. 2001, 14 (6): 685-692. 10.1002/jmri.10019.CrossRefPubMed Bloomer TN, Plein S, Radjenovic A, Higgins DM, Jones TR, Ridgway JP, Sivananthan MU: Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle. J Magn Reson Imaging. 2001, 14 (6): 685-692. 10.1002/jmri.10019.CrossRefPubMed
7.
go back to reference Moon JC, Lorenz CH, Francis JM, Smith GC, Pennell DJ: Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility. Radiology. 2002, 223 (3): 789-797. 10.1148/radiol.2233011181.CrossRefPubMed Moon JC, Lorenz CH, Francis JM, Smith GC, Pennell DJ: Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility. Radiology. 2002, 223 (3): 789-797. 10.1148/radiol.2233011181.CrossRefPubMed
8.
go back to reference Kozerke S, Tsao J: Reduced data acquisition methods in cardiac imaging. Top Magn Reson Imaging. 2004, 15: 161-168. 10.1097/01.rmr.0000132789.84706.9d.CrossRefPubMed Kozerke S, Tsao J: Reduced data acquisition methods in cardiac imaging. Top Magn Reson Imaging. 2004, 15: 161-168. 10.1097/01.rmr.0000132789.84706.9d.CrossRefPubMed
9.
go back to reference Tsao J, Boesiger P, Pruessmann KP: k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med. 2003, 50 (5): 1031-1042. 10.1002/mrm.10611.CrossRefPubMed Tsao J, Boesiger P, Pruessmann KP: k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med. 2003, 50 (5): 1031-1042. 10.1002/mrm.10611.CrossRefPubMed
10.
go back to reference Baltes C, Kozerke S, Hansen MS, Pruessmann KP, Tsao J, Boesiger P: Accelerating cine phase-contrast flow measurements using k-t BLAST and k-t SENSE. Magn Reson Med. 2005, 54 (6): 1430-8. 10.1002/mrm.20730.CrossRefPubMed Baltes C, Kozerke S, Hansen MS, Pruessmann KP, Tsao J, Boesiger P: Accelerating cine phase-contrast flow measurements using k-t BLAST and k-t SENSE. Magn Reson Med. 2005, 54 (6): 1430-8. 10.1002/mrm.20730.CrossRefPubMed
11.
go back to reference Tsao J, Kozerke S, Boesiger P, Pruessmann KP: Optimizing spatiotemporal sampling for k-t BLAST and k-t SENSE: application to high-resolution real-time cardiac steady-state free precession. Magn Reson Med. 2005, 53 (6): 1372-82. 10.1002/mrm.20483.CrossRefPubMed Tsao J, Kozerke S, Boesiger P, Pruessmann KP: Optimizing spatiotemporal sampling for k-t BLAST and k-t SENSE: application to high-resolution real-time cardiac steady-state free precession. Magn Reson Med. 2005, 53 (6): 1372-82. 10.1002/mrm.20483.CrossRefPubMed
12.
go back to reference Jahnke C, Paetsch I, Gebker R, Bornstedt A, Fleck E, Nagel E: Accelerated 4D dobutamine stress MR imaging with k-t BLAST: feasibility and diagnostic performance. Radiology. 2006, 241: 718-28. 10.1148/radiol.2413051522.CrossRefPubMed Jahnke C, Paetsch I, Gebker R, Bornstedt A, Fleck E, Nagel E: Accelerated 4D dobutamine stress MR imaging with k-t BLAST: feasibility and diagnostic performance. Radiology. 2006, 241: 718-28. 10.1148/radiol.2413051522.CrossRefPubMed
13.
go back to reference McConnell MV, Khasgiwala VC, Savord BJ, Chen MH, Chuang ML, Edelman RR, Manning WJ: Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. AJR Am J Roentgenol. 1997, 168 (5): 1369-1375.CrossRefPubMed McConnell MV, Khasgiwala VC, Savord BJ, Chen MH, Chuang ML, Edelman RR, Manning WJ: Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. AJR Am J Roentgenol. 1997, 168 (5): 1369-1375.CrossRefPubMed
14.
go back to reference Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986, 1: 307-311.CrossRefPubMed Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986, 1: 307-311.CrossRefPubMed
15.
go back to reference Lin LI: A concordance coefficient to evaluate reproducibility. Biometrics. 1989, 45 (1): 255-268. 10.2307/2532051.CrossRefPubMed Lin LI: A concordance coefficient to evaluate reproducibility. Biometrics. 1989, 45 (1): 255-268. 10.2307/2532051.CrossRefPubMed
18.
go back to reference Paetsch I, Thiele H, Schnackenburg B, Bornstedt A, Müller-York A, Schwab J, Fleck E, Nagel E: Improved functional cardiac MR imaging using the intravascular contrast agent CLARISCAN. Int J Cardiovasc Imaging. 2003, 19 (4): 337-43. 10.1023/A:1025432415983.CrossRefPubMed Paetsch I, Thiele H, Schnackenburg B, Bornstedt A, Müller-York A, Schwab J, Fleck E, Nagel E: Improved functional cardiac MR imaging using the intravascular contrast agent CLARISCAN. Int J Cardiovasc Imaging. 2003, 19 (4): 337-43. 10.1023/A:1025432415983.CrossRefPubMed
19.
go back to reference Hansen MS, Baltes C, Tsao J, Kozerke S, Pruessmann KP, Eggers H: k-t BLAST reconstruction from non-Cartesian k-t space sampling. Magn Reson Med. 2006, 55 (1): 85-91. 10.1002/mrm.20734.CrossRefPubMed Hansen MS, Baltes C, Tsao J, Kozerke S, Pruessmann KP, Eggers H: k-t BLAST reconstruction from non-Cartesian k-t space sampling. Magn Reson Med. 2006, 55 (1): 85-91. 10.1002/mrm.20734.CrossRefPubMed
20.
go back to reference Jahnke C, Nagel E, Gebker R, Bornstedt A, Schnackenburg B, Kozerke S, Fleck E, Paetsch I: Four-dimensional single breathhold magnetic resonance imaging using kt-BLAST enables reliable assessment of left- and right-ventricular volumes and mass. J Magnetic Resonance Imaging. 2007, 25 (4): 737-742. 10.1002/jmri.20877.CrossRef Jahnke C, Nagel E, Gebker R, Bornstedt A, Schnackenburg B, Kozerke S, Fleck E, Paetsch I: Four-dimensional single breathhold magnetic resonance imaging using kt-BLAST enables reliable assessment of left- and right-ventricular volumes and mass. J Magnetic Resonance Imaging. 2007, 25 (4): 737-742. 10.1002/jmri.20877.CrossRef
21.
go back to reference Greil GF, Germann S, Kozerke S, Baltes C, Tsao J, Urschitz MS, Seeger A, Tangcharoen T, Bialkowsky A, Miller S, Sieverding L: Assessment of left ventricular volumes and mass with fast 3D cine steady-state free precession k-t space broad-use linear acquisition speed-up technique (k-t BLAST). J Magnetic Resonance Imaging. 2008, 27 (3): 510-515. 10.1002/jmri.21200.CrossRef Greil GF, Germann S, Kozerke S, Baltes C, Tsao J, Urschitz MS, Seeger A, Tangcharoen T, Bialkowsky A, Miller S, Sieverding L: Assessment of left ventricular volumes and mass with fast 3D cine steady-state free precession k-t space broad-use linear acquisition speed-up technique (k-t BLAST). J Magnetic Resonance Imaging. 2008, 27 (3): 510-515. 10.1002/jmri.21200.CrossRef
Metadata
Title
Measurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSE
Authors
Neil Maredia
Sebastian Kozerke
Abdul Larghat
Nik Abidin
John P Greenwood
Peter Boesiger
Sven Plein
Publication date
01-12-2008
Publisher
BioMed Central
Published in
Journal of Cardiovascular Magnetic Resonance / Issue 1/2008
Electronic ISSN: 1532-429X
DOI
https://doi.org/10.1186/1532-429X-10-27

Other articles of this Issue 1/2008

Journal of Cardiovascular Magnetic Resonance 1/2008 Go to the issue