Abstract

Background

The benefits of sentinel lymph node biopsy (SLNB) for breast cancer patients with histologically negative axillary nodes, in whom axillary lymph node dissection (ALND) is thereby avoided, are now established. Low false negative rate, certainly with blue dye technique, mostly reflects the established high inherent accuracy of SLNB and low axillary nodal metastatic load (subject to patient selection). SLN identification rate is influenced by volume, injection site and choice of mapping agent, axillary nodal metastatic load, SLN location and skill at axillary dissection. Being more subject to technical failure, SLN identification seems to be a more reasonable variable for learning curve assessment than false negative rate.
Methylene blue is as good an SLN mapping agent as Isosulfan blue and is much cheaper. Addition of radio-colloid mapping to blue dye does not achieve a sufficiently higher identification rate to justify the cost. Methylene blue is therefore the agent of choice for SLN mapping in developing countries.
The American Society of Breast Surgeons recommends that, for competence, surgeons should perform 20 SLNB but admits that the learning curve with a standardized technique may be "much shorter". One appropriate remedy for this dilemma is to plot individual learning curves.

Methods

Using methylene blue dye, experienced breast surgeons performed SLNB in selected patients with breast cancer (primary tumor < 5 cm and clinically negative ipsilateral axilla). Intraoperative assessment and completion ALND were performed for standardization on the first 13 of 24 cases. SLN identification was plotted for each surgeon on a tabular cumulative sum (CUSUM) chart with sequential probability ratio test (SPRT) limits based on a target identification rate of 85%.

Results

The CUSUM plot crossed the SPRT limit line after 8 consecutive, positively identified SLN, signaling achievement of an acceptable level of competence.

Conclusion

Tabular CUSUM charting, based on a justified choice of parameters, indicates that the learning curve for SLNB using methylene blue dye is completed after 8 consecutive, positively identified SLN. CUSUM charting may be used to plot individual learning curves for trainee surgeons by applying a proxy parameter for failure in the presence of a mentor (such as failed SLN identification within 15 minutes).
Appendix
Available only for authorised users
Literature
1.
go back to reference Mansel RE, Fallowfield L, Kissin M, Goyal A, Newcombe RG, Dixon JM, Yiangou C, Horgan K, Bundred N, Monypenny I: Randomized multicenter trial of sentinel node biopsy versus standard axillary treatment in operable breast cancer: the ALMANAC Trial. J Natl Cancer Inst. 2006, 98: 599-609.CrossRefPubMed Mansel RE, Fallowfield L, Kissin M, Goyal A, Newcombe RG, Dixon JM, Yiangou C, Horgan K, Bundred N, Monypenny I: Randomized multicenter trial of sentinel node biopsy versus standard axillary treatment in operable breast cancer: the ALMANAC Trial. J Natl Cancer Inst. 2006, 98: 599-609.CrossRefPubMed
2.
go back to reference Kim T, Giuliano AE, Lyman GH: Lymphatic mapping and sentinel lymph node biopsy in early-stage breast carcinoma: a metaanalysis. Cancer. 2006, 106: 4-16. 10.1002/cncr.21568.CrossRefPubMed Kim T, Giuliano AE, Lyman GH: Lymphatic mapping and sentinel lymph node biopsy in early-stage breast carcinoma: a metaanalysis. Cancer. 2006, 106: 4-16. 10.1002/cncr.21568.CrossRefPubMed
3.
go back to reference Carmon M, Olsha O, Rivkin L, Spira RM, Golomb E: Intraoperative palpation for clinically suspicious axillary sentinel lymph nodes reduces the false-negative rate of sentinel lymph node biopsy in breast cancer. Breast J. 2006, 12: 199-201. 10.1111/j.1075-122X.2006.00241.x.CrossRefPubMed Carmon M, Olsha O, Rivkin L, Spira RM, Golomb E: Intraoperative palpation for clinically suspicious axillary sentinel lymph nodes reduces the false-negative rate of sentinel lymph node biopsy in breast cancer. Breast J. 2006, 12: 199-201. 10.1111/j.1075-122X.2006.00241.x.CrossRefPubMed
4.
go back to reference Simmons RM: Review of sentinel lymph node credentialing: how many cases are enough?. J Am Coll Surg. 2001, 193: 206-209. 10.1016/S1072-7515(01)00998-X.CrossRefPubMed Simmons RM: Review of sentinel lymph node credentialing: how many cases are enough?. J Am Coll Surg. 2001, 193: 206-209. 10.1016/S1072-7515(01)00998-X.CrossRefPubMed
5.
go back to reference O'Hea BJ, Hill AD, El Shirbiny AM, Yeh SD, Rosen PP, Coit DG, Borgen PI, Cody HS: Sentinel lymph node biopsy in breast cancer: initial experience at Memorial Sloan-Kettering Cancer Center. J Am Coll Surg. 1998, 186: 423-427. 10.1016/S1072-7515(98)00060-X.CrossRefPubMed O'Hea BJ, Hill AD, El Shirbiny AM, Yeh SD, Rosen PP, Coit DG, Borgen PI, Cody HS: Sentinel lymph node biopsy in breast cancer: initial experience at Memorial Sloan-Kettering Cancer Center. J Am Coll Surg. 1998, 186: 423-427. 10.1016/S1072-7515(98)00060-X.CrossRefPubMed
6.
go back to reference Cox C, White L, Allred N, Meyers M, Dickson D, Dupont E, Cantor A, Ly Q, Dessureault S, King J: Survival outcomes in node-negative breast cancer patients evaluated with complete axillary node dissection versus sentinel lymph node biopsy. Ann Surg Oncol. 2006, 13: 708-711. 10.1245/ASO.2006.05.017.CrossRefPubMed Cox C, White L, Allred N, Meyers M, Dickson D, Dupont E, Cantor A, Ly Q, Dessureault S, King J: Survival outcomes in node-negative breast cancer patients evaluated with complete axillary node dissection versus sentinel lymph node biopsy. Ann Surg Oncol. 2006, 13: 708-711. 10.1245/ASO.2006.05.017.CrossRefPubMed
7.
go back to reference Kuijt GP, Poll-Franse van de LV, Voogd AC, Nieuwenhuijzen GA, Roumen RM: Survival after negative sentinel lymph node biopsy in breast cancer at least equivalent to after negative extensive axillary dissection. Eur J Surg Oncol. 2006, 33 (7): 832-837.CrossRefPubMed Kuijt GP, Poll-Franse van de LV, Voogd AC, Nieuwenhuijzen GA, Roumen RM: Survival after negative sentinel lymph node biopsy in breast cancer at least equivalent to after negative extensive axillary dissection. Eur J Surg Oncol. 2006, 33 (7): 832-837.CrossRefPubMed
8.
go back to reference Naik AM, Fey J, Gemignani M, Heerdt A, Montgomery L, Petrek J, Port E, Sacchini V, Sclafani L, VanZee K: The risk of axillary relapse after sentinel lymph node biopsy for breast cancer is comparable with that of axillary lymph node dissection: a follow-up study of 4008 procedures. Ann Surg. 2004, 240: 462-468. 10.1097/01.sla.0000137130.23530.19.CrossRefPubMedPubMedCentral Naik AM, Fey J, Gemignani M, Heerdt A, Montgomery L, Petrek J, Port E, Sacchini V, Sclafani L, VanZee K: The risk of axillary relapse after sentinel lymph node biopsy for breast cancer is comparable with that of axillary lymph node dissection: a follow-up study of 4008 procedures. Ann Surg. 2004, 240: 462-468. 10.1097/01.sla.0000137130.23530.19.CrossRefPubMedPubMedCentral
9.
go back to reference Gold HT, Do HT, Osborne MP: Cost-effectiveness of isosulfan blue vs. methylene blue dye in sentinel node biopsy. J Clin Oncol. 2005, 23: 6103- Gold HT, Do HT, Osborne MP: Cost-effectiveness of isosulfan blue vs. methylene blue dye in sentinel node biopsy. J Clin Oncol. 2005, 23: 6103-
10.
go back to reference Simmons R, Thevarajah S, Brennan MB, Christos P, Osborne M: Methylene blue dye as an alternative to isosulfan blue dye for sentinel lymph node localization. Ann Surg Oncol. 2003, 10: 242-247. 10.1245/ASO.2003.04.021.CrossRefPubMed Simmons R, Thevarajah S, Brennan MB, Christos P, Osborne M: Methylene blue dye as an alternative to isosulfan blue dye for sentinel lymph node localization. Ann Surg Oncol. 2003, 10: 242-247. 10.1245/ASO.2003.04.021.CrossRefPubMed
11.
go back to reference Salhab M, Al Sarakbi W, Mokbel K: Skin and fat necrosis of the breast following methylene blue dye injection for sentinel node biopsy in a patient with breast cancer. Int Semin Surg Oncol. 2005, 2: 26-10.1186/1477-7800-2-26.CrossRefPubMedPubMedCentral Salhab M, Al Sarakbi W, Mokbel K: Skin and fat necrosis of the breast following methylene blue dye injection for sentinel node biopsy in a patient with breast cancer. Int Semin Surg Oncol. 2005, 2: 26-10.1186/1477-7800-2-26.CrossRefPubMedPubMedCentral
12.
go back to reference Blessing WD, Stolier AJ, Teng SC, Bolton JS, Fuhrman GM: A comparison of methylene blue and lymphazurin in breast cancer sentinel node mapping. Am J Surg. 2002, 184: 341-345. 10.1016/S0002-9610(02)00948-0.CrossRefPubMed Blessing WD, Stolier AJ, Teng SC, Bolton JS, Fuhrman GM: A comparison of methylene blue and lymphazurin in breast cancer sentinel node mapping. Am J Surg. 2002, 184: 341-345. 10.1016/S0002-9610(02)00948-0.CrossRefPubMed
13.
go back to reference Eldrageely K, Vargas MP, Khalkhali I, Venegas R, Burla M, Gonzalez KD, Vargas HI: Sentinel lymph node mapping of breast cancer: a case-control study of methylene blue tracer compared to isosulfan blue. Am Surg. 2004, 70: 872-875.PubMed Eldrageely K, Vargas MP, Khalkhali I, Venegas R, Burla M, Gonzalez KD, Vargas HI: Sentinel lymph node mapping of breast cancer: a case-control study of methylene blue tracer compared to isosulfan blue. Am Surg. 2004, 70: 872-875.PubMed
14.
go back to reference Golshan M, Nakhlis F: Can methylene blue only be used in sentinel lymph node biopsy for breast cancer?. Breast J. 2006, 12: 428-430. 10.1111/j.1075-122X.2006.00299.x.CrossRefPubMed Golshan M, Nakhlis F: Can methylene blue only be used in sentinel lymph node biopsy for breast cancer?. Breast J. 2006, 12: 428-430. 10.1111/j.1075-122X.2006.00299.x.CrossRefPubMed
15.
go back to reference Nour A: Efficacy of methylene blue dye in localization of sentinel lymph node in breast cancer patients. Breast J. 2004, 10: 388-391. 10.1111/j.1075-122X.2004.21360.x.CrossRefPubMed Nour A: Efficacy of methylene blue dye in localization of sentinel lymph node in breast cancer patients. Breast J. 2004, 10: 388-391. 10.1111/j.1075-122X.2004.21360.x.CrossRefPubMed
16.
go back to reference Varghese P, Mostafa A, Abdel-Rahman AT, Akberali S, Gattuso J, Canizales A, Wells CA, Carpenter R: Methylene blue dye versus combined dye-radioactive tracer technique for sentinel lymph node localisation in early breast cancer. Eur J Surg Oncol. 2007, 33: 147-152. 10.1016/j.ejso.2006.09.026.CrossRefPubMed Varghese P, Mostafa A, Abdel-Rahman AT, Akberali S, Gattuso J, Canizales A, Wells CA, Carpenter R: Methylene blue dye versus combined dye-radioactive tracer technique for sentinel lymph node localisation in early breast cancer. Eur J Surg Oncol. 2007, 33: 147-152. 10.1016/j.ejso.2006.09.026.CrossRefPubMed
17.
go back to reference Newman LA: Lymphatic mapping and sentinel lymph node biopsy in breast cancer patients: a comprehensive review of variations in performance and technique. J Am Coll Surg. 2004, 199: 804-816. 10.1016/j.jamcollsurg.2004.05.277.CrossRefPubMed Newman LA: Lymphatic mapping and sentinel lymph node biopsy in breast cancer patients: a comprehensive review of variations in performance and technique. J Am Coll Surg. 2004, 199: 804-816. 10.1016/j.jamcollsurg.2004.05.277.CrossRefPubMed
18.
go back to reference Derossis AM, Fey J, Yeung H, Yeh SD, Heerdt AS, Petrek J, VanZee KJ, Montgomery LL, Borgen PI, Cody HS: A trend analysis of the relative value of blue dye and isotope localization in 2,000 consecutive cases of sentinel node biopsy for breast cancer. J Am Coll Surg. 2001, 193: 473-478. 10.1016/S1072-7515(01)01038-9.CrossRefPubMed Derossis AM, Fey J, Yeung H, Yeh SD, Heerdt AS, Petrek J, VanZee KJ, Montgomery LL, Borgen PI, Cody HS: A trend analysis of the relative value of blue dye and isotope localization in 2,000 consecutive cases of sentinel node biopsy for breast cancer. J Am Coll Surg. 2001, 193: 473-478. 10.1016/S1072-7515(01)01038-9.CrossRefPubMed
19.
go back to reference McMasters KM, Tuttle TM, Carlson DJ, Brown CM, Noyes RD, Glaser RL, Vennekotter DJ, Turk PS, Tate PS, Sardi A: Sentinel lymph node biopsy for breast cancer: a suitable alternative to routine axillary dissection in multi-institutional practice when optimal technique is used. J Clin Oncol. 2000, 18: 2560-2566.PubMed McMasters KM, Tuttle TM, Carlson DJ, Brown CM, Noyes RD, Glaser RL, Vennekotter DJ, Turk PS, Tate PS, Sardi A: Sentinel lymph node biopsy for breast cancer: a suitable alternative to routine axillary dissection in multi-institutional practice when optimal technique is used. J Clin Oncol. 2000, 18: 2560-2566.PubMed
20.
go back to reference Hung WK, Chan CM, Ying M, Chong SF, Mak KL, Yip AW: Randomized clinical trial comparing blue dye with combined dye and isotope for sentinel lymph node biopsy in breast cancer. Br J Surg. 2005, 92: 1494-1497. 10.1002/bjs.5211.CrossRefPubMed Hung WK, Chan CM, Ying M, Chong SF, Mak KL, Yip AW: Randomized clinical trial comparing blue dye with combined dye and isotope for sentinel lymph node biopsy in breast cancer. Br J Surg. 2005, 92: 1494-1497. 10.1002/bjs.5211.CrossRefPubMed
21.
go back to reference Morrow M, Rademaker AW, Bethke KP, Talamonti MS, Dawes LG, Clauson J, Hansen N: Learning sentinel node biopsy: results of a prospective randomized trial of two techniques. Surgery. 1999, 126: 714-720.CrossRefPubMed Morrow M, Rademaker AW, Bethke KP, Talamonti MS, Dawes LG, Clauson J, Hansen N: Learning sentinel node biopsy: results of a prospective randomized trial of two techniques. Surgery. 1999, 126: 714-720.CrossRefPubMed
22.
go back to reference Klausen TL, Chakera AH, Friis E, Rank F, Hesse B, Holm S: Radiation doses to staff involved in sentinel node operations for breast cancer. Clin Physiol Funct Imaging. 2005, 25: 196-202. 10.1111/j.1475-097X.2005.00611.x.CrossRefPubMed Klausen TL, Chakera AH, Friis E, Rank F, Hesse B, Holm S: Radiation doses to staff involved in sentinel node operations for breast cancer. Clin Physiol Funct Imaging. 2005, 25: 196-202. 10.1111/j.1475-097X.2005.00611.x.CrossRefPubMed
23.
go back to reference Fisher B, Jeong JH, Anderson S, Bryant J, Fisher ER, Wolmark N: Twenty-five-year follow-up of a randomized trial comparing radical mastectomy, total mastectomy, and total mastectomy followed by irradiation. N Engl J Med. 2002, 347: 567-575. 10.1056/NEJMoa020128.CrossRefPubMed Fisher B, Jeong JH, Anderson S, Bryant J, Fisher ER, Wolmark N: Twenty-five-year follow-up of a randomized trial comparing radical mastectomy, total mastectomy, and total mastectomy followed by irradiation. N Engl J Med. 2002, 347: 567-575. 10.1056/NEJMoa020128.CrossRefPubMed
25.
go back to reference Lerch L, Donald JC, Olivotto IA, Lesperance M, van der WN, Rusnak C, Biberdorf D, Ross A, Hayashi A: Measuring surgeon performance of sentinel lymph node biopsy in breast cancer treatment by cumulative sum analysis. Am J Surg. 2007, 193: 556-559. 10.1016/j.amjsurg.2007.01.012.CrossRefPubMed Lerch L, Donald JC, Olivotto IA, Lesperance M, van der WN, Rusnak C, Biberdorf D, Ross A, Hayashi A: Measuring surgeon performance of sentinel lymph node biopsy in breast cancer treatment by cumulative sum analysis. Am J Surg. 2007, 193: 556-559. 10.1016/j.amjsurg.2007.01.012.CrossRefPubMed
26.
go back to reference Davies OL: Design and analysis of industrial experiments. 1956, London: Oliver and Boyd Davies OL: Design and analysis of industrial experiments. 1956, London: Oliver and Boyd
27.
go back to reference Biau DJ, Resche-Rigon M, Godiris-Petit G, Nizard RS, Porcher R: Quality control of surgical and interventional procedures: a review of the CUSUM. Qual Saf Health Care. 2007, 16: 203-207. 10.1136/qshc.2006.020776.CrossRefPubMedPubMedCentral Biau DJ, Resche-Rigon M, Godiris-Petit G, Nizard RS, Porcher R: Quality control of surgical and interventional procedures: a review of the CUSUM. Qual Saf Health Care. 2007, 16: 203-207. 10.1136/qshc.2006.020776.CrossRefPubMedPubMedCentral
28.
go back to reference Sibanda T, Sibanda N: The CUSUM chart method as a tool for continuous monitoring of clinical outcomes using routinely collected data. BMC Med Res Methodol. 2007, 7: 46-10.1186/1471-2288-7-46.CrossRefPubMedPubMedCentral Sibanda T, Sibanda N: The CUSUM chart method as a tool for continuous monitoring of clinical outcomes using routinely collected data. BMC Med Res Methodol. 2007, 7: 46-10.1186/1471-2288-7-46.CrossRefPubMedPubMedCentral
30.
go back to reference Grunkemeier GL, Wu YX, Furnary AP: Cumulative sum techniques for assessing surgical results. Ann Thorac Surg. 2003, 76: 663-667. 10.1016/S0003-4975(03)00873-7.CrossRefPubMed Grunkemeier GL, Wu YX, Furnary AP: Cumulative sum techniques for assessing surgical results. Ann Thorac Surg. 2003, 76: 663-667. 10.1016/S0003-4975(03)00873-7.CrossRefPubMed
31.
go back to reference Kestin IG: A statistical approach to measuring the competence of anaesthetic trainees at practical procedures. Br J Anaesth. 1995, 75: 805-809.CrossRefPubMed Kestin IG: A statistical approach to measuring the competence of anaesthetic trainees at practical procedures. Br J Anaesth. 1995, 75: 805-809.CrossRefPubMed
32.
go back to reference Oliveira Filho GR: The construction of learning curves for basic skills in anesthetic procedures: an application for the cumulative sum method. Anesth Analg. 2002, 95: 411-6. 10.1097/00000539-200208000-00033.PubMed Oliveira Filho GR: The construction of learning curves for basic skills in anesthetic procedures: an application for the cumulative sum method. Anesth Analg. 2002, 95: 411-6. 10.1097/00000539-200208000-00033.PubMed
33.
go back to reference Van Rij AM, McDonald JR, Pettigrew RA, Putterill MJ, Reddy CK, Wright JJ: Cusum as an aid to early assessment of the surgical trainee. Br J Surg. 1995, 82: 1500-1503. 10.1002/bjs.1800821117.CrossRefPubMed Van Rij AM, McDonald JR, Pettigrew RA, Putterill MJ, Reddy CK, Wright JJ: Cusum as an aid to early assessment of the surgical trainee. Br J Surg. 1995, 82: 1500-1503. 10.1002/bjs.1800821117.CrossRefPubMed
34.
go back to reference Young A, Miller JP, Azarow K: Establishing learning curves for surgical residents using Cumulative Summation (CUSUM) Analysis. Curr Surg. 2005, 62: 330-334. 10.1016/j.cursur.2004.09.016.CrossRefPubMed Young A, Miller JP, Azarow K: Establishing learning curves for surgical residents using Cumulative Summation (CUSUM) Analysis. Curr Surg. 2005, 62: 330-334. 10.1016/j.cursur.2004.09.016.CrossRefPubMed
35.
go back to reference Clarke D, Newcombe RG, Mansel RE: The learning curve in sentinel node biopsy: the ALMANAC experience. Ann Surg Oncol. 2004, 11: 211S-215S.CrossRefPubMed Clarke D, Newcombe RG, Mansel RE: The learning curve in sentinel node biopsy: the ALMANAC experience. Ann Surg Oncol. 2004, 11: 211S-215S.CrossRefPubMed
36.
go back to reference D'Eredita' G, Ferrarese F, Cecere V, Massa ST, de Carne F, Fabiano G: Subareolar injection may be more accurate than other techniques for sentinel lymph node biopsy in breast cancer. Ann Surg Oncol. 2003, 10: 942-947. 10.1245/ASO.2003.01.022.CrossRefPubMed D'Eredita' G, Ferrarese F, Cecere V, Massa ST, de Carne F, Fabiano G: Subareolar injection may be more accurate than other techniques for sentinel lymph node biopsy in breast cancer. Ann Surg Oncol. 2003, 10: 942-947. 10.1245/ASO.2003.01.022.CrossRefPubMed
37.
go back to reference Kern KA: Sentinel lymph node mapping in breast cancer using subareolar injection of blue dye. J Am Coll Surg. 1999, 189: 539-545. 10.1016/S1072-7515(99)00200-8.CrossRefPubMed Kern KA: Sentinel lymph node mapping in breast cancer using subareolar injection of blue dye. J Am Coll Surg. 1999, 189: 539-545. 10.1016/S1072-7515(99)00200-8.CrossRefPubMed
38.
go back to reference Klimberg VS, Rubio IT, Henry R, Cowan C, Colvert M, Korourian S: Subareolar versus peritumoral injection for location of the sentinel lymph node. Ann Surg. 1999, 229: 860-864. 10.1097/00000658-199906000-00013.CrossRefPubMedPubMedCentral Klimberg VS, Rubio IT, Henry R, Cowan C, Colvert M, Korourian S: Subareolar versus peritumoral injection for location of the sentinel lymph node. Ann Surg. 1999, 229: 860-864. 10.1097/00000658-199906000-00013.CrossRefPubMedPubMedCentral
39.
go back to reference Brogi E, Torres-Matundan E, Tan LK, Cody HS: The results of frozen section, touch preparation, and cytological smear are comparable for intraoperative examination of sentinel lymph nodes: a study in 133 breast cancer patients. Ann Surg Oncol. 2005, 12: 173-180. 10.1245/ASO.2005.03.067.CrossRefPubMed Brogi E, Torres-Matundan E, Tan LK, Cody HS: The results of frozen section, touch preparation, and cytological smear are comparable for intraoperative examination of sentinel lymph nodes: a study in 133 breast cancer patients. Ann Surg Oncol. 2005, 12: 173-180. 10.1245/ASO.2005.03.067.CrossRefPubMed
40.
go back to reference McLaughlin SA, Ochoa-Frongia LM, Patil SM, Cody HS, Sclafani LM: Influence of frozen-section analysis of sentinel lymph node and lumpectomy margin status on reoperation rates in patients undergoing breast-conservation therapy. J Am Coll Surg. 2008, 206: 76-82. 10.1016/j.jamcollsurg.2007.07.021.CrossRefPubMed McLaughlin SA, Ochoa-Frongia LM, Patil SM, Cody HS, Sclafani LM: Influence of frozen-section analysis of sentinel lymph node and lumpectomy margin status on reoperation rates in patients undergoing breast-conservation therapy. J Am Coll Surg. 2008, 206: 76-82. 10.1016/j.jamcollsurg.2007.07.021.CrossRefPubMed
41.
go back to reference Fenaroli P, Tondini C, Motta T, Virotta G, Personeni A: Axillary sentinel node biopsy under local anaesthesia in early breast cancer. Ann Oncol. 2000, 11: 1617-1618. 10.1023/A:1008341101082.CrossRefPubMed Fenaroli P, Tondini C, Motta T, Virotta G, Personeni A: Axillary sentinel node biopsy under local anaesthesia in early breast cancer. Ann Oncol. 2000, 11: 1617-1618. 10.1023/A:1008341101082.CrossRefPubMed
42.
go back to reference de Kanter AY, Menke-Pluijmers MB, Henzen-Logmans SC, van Geel AN, van Eijck CJ, Wiggers T, Eggermont AM: Reasons for failure to identify positive sentinel nodes in breast cancer patients with significant nodal involvement. Eur J Surg Oncol. 2006, 32: 498-501. 10.1016/j.ejso.2006.02.012.CrossRefPubMed de Kanter AY, Menke-Pluijmers MB, Henzen-Logmans SC, van Geel AN, van Eijck CJ, Wiggers T, Eggermont AM: Reasons for failure to identify positive sentinel nodes in breast cancer patients with significant nodal involvement. Eur J Surg Oncol. 2006, 32: 498-501. 10.1016/j.ejso.2006.02.012.CrossRefPubMed
43.
go back to reference Mathijssen IM, Strijdhorst H, Kiestra SK, Wereldsma JC: Added value of ultrasound in screening the clinically negative axilla in breast cancer. J Surg Oncol. 2006, 94: 364-367. 10.1002/jso.20590.CrossRefPubMed Mathijssen IM, Strijdhorst H, Kiestra SK, Wereldsma JC: Added value of ultrasound in screening the clinically negative axilla in breast cancer. J Surg Oncol. 2006, 94: 364-367. 10.1002/jso.20590.CrossRefPubMed
44.
go back to reference Biau DJ, Williams SM, Schlup MM, Nizard RS, Porcher R: Quantitative and individualized assessment of the learning curve using LC-CUSUM. Br J Surg. 2008, 95: 925-929. 10.1002/bjs.6056.CrossRefPubMed Biau DJ, Williams SM, Schlup MM, Nizard RS, Porcher R: Quantitative and individualized assessment of the learning curve using LC-CUSUM. Br J Surg. 2008, 95: 925-929. 10.1002/bjs.6056.CrossRefPubMed
45.
go back to reference Tekkis PP, Senagore AJ, Delaney CP, Fazio VW: Evaluation of the learning curve in laparoscopic colorectal surgery: comparison of right-sided and left-sided resections. Ann Surg. 2005, 242: 83-91. 10.1097/01.sla.0000167857.14690.68.CrossRefPubMedPubMedCentral Tekkis PP, Senagore AJ, Delaney CP, Fazio VW: Evaluation of the learning curve in laparoscopic colorectal surgery: comparison of right-sided and left-sided resections. Ann Surg. 2005, 242: 83-91. 10.1097/01.sla.0000167857.14690.68.CrossRefPubMedPubMedCentral
46.
go back to reference Tekkis PP, Fazio VW, Lavery IC, Remzi FH, Senagore AJ, Wu JS, Strong SA, Poloneicki JD, Hull TL, Church JM: Evaluation of the learning curve in ileal pouch-anal anastomosis surgery. Ann Surg. 2005, 241: 262-268. 10.1097/01.sla.0000152018.99541.f1.CrossRefPubMedPubMedCentral Tekkis PP, Fazio VW, Lavery IC, Remzi FH, Senagore AJ, Wu JS, Strong SA, Poloneicki JD, Hull TL, Church JM: Evaluation of the learning curve in ileal pouch-anal anastomosis surgery. Ann Surg. 2005, 241: 262-268. 10.1097/01.sla.0000152018.99541.f1.CrossRefPubMedPubMedCentral
47.
go back to reference Spiegelhalter D, Grigg O, Kinsman R, Treasure T: Risk-adjusted sequential probability ratio tests: applications to Bristol, Shipman and adult cardiac surgery. Int J Qual Health Care. 2003, 15: 7-13. 10.1093/intqhc/15.1.7.CrossRefPubMed Spiegelhalter D, Grigg O, Kinsman R, Treasure T: Risk-adjusted sequential probability ratio tests: applications to Bristol, Shipman and adult cardiac surgery. Int J Qual Health Care. 2003, 15: 7-13. 10.1093/intqhc/15.1.7.CrossRefPubMed
48.
go back to reference Marrazzo A, Taormina P, Noto A, Cardinale G, Casa L, Mercadante S, Lo GD, David M: Localization of the sentinel lymph node in breast cancer: prospective comparison of vital staining and radioactive tracing methods. Chir Ital. 2004, 56: 621-627.PubMed Marrazzo A, Taormina P, Noto A, Cardinale G, Casa L, Mercadante S, Lo GD, David M: Localization of the sentinel lymph node in breast cancer: prospective comparison of vital staining and radioactive tracing methods. Chir Ital. 2004, 56: 621-627.PubMed
Metadata
Title
Sentinel lymph node biopsy for breast cancer using methylene blue dye manifests a short learning curve among experienced surgeons: a prospective tabular cumulative sum (CUSUM) analysis
Authors
Jeffrey M East
Christopher SP Valentine
Emil Kanchev
Garfield O Blake
Publication date
01-12-2009
Publisher
BioMed Central
Published in
BMC Surgery / Issue 1/2009
Electronic ISSN: 1471-2482
DOI
https://doi.org/10.1186/1471-2482-9-2

Other articles of this Issue 1/2009

BMC Surgery 1/2009 Go to the issue