Abstract

Background

Stress fractures of the base of the acromion are rare and tend to progress well when conservatively treated. The need for surgery due to this type of fracture has only been reported in two case reports.

Case presentation

A 39-year-old patient, manual laborer, with a stress fracture at the base of the acromion that required surgical treatment due to persistent symptoms and consolidation failure.

Conclusion

We described a new mechanism of injury for stress fractures of the base of the acromion. After the failure of conservative treatment, the patient exhibited good results with osteosynthesis with a plate and screws, with no need for a bone graft.
Appendix
Available only for authorised users
Literature
1.
go back to reference Anavian J, Wijdicks CA, Schroder LK, Vang S, Cole PA: Surgery for scapula process fractures. Good outcome in 26 patients. Acta Orthop. 2009, 80: 344-350. 10.3109/17453670903025394.CrossRefPubMedPubMedCentral Anavian J, Wijdicks CA, Schroder LK, Vang S, Cole PA: Surgery for scapula process fractures. Good outcome in 26 patients. Acta Orthop. 2009, 80: 344-350. 10.3109/17453670903025394.CrossRefPubMedPubMedCentral
2.
go back to reference Hill BW, Anavian J, Jacobson AR, Cole PA: Surgical management of isolated acromion fractures: Technical tricks and clinical experience. J Orthop Trauma. 2014, 28: 107-113. 10.1097/BOT.0000000000000040.CrossRef Hill BW, Anavian J, Jacobson AR, Cole PA: Surgical management of isolated acromion fractures: Technical tricks and clinical experience. J Orthop Trauma. 2014, 28: 107-113. 10.1097/BOT.0000000000000040.CrossRef
3.
go back to reference Dennis D, Ferlic D, Clayton M: Acromial stress fractures associated with cuff-tear arthropathy. J Bone Joint Surg Am. 1986, 68: 937-940.PubMed Dennis D, Ferlic D, Clayton M: Acromial stress fractures associated with cuff-tear arthropathy. J Bone Joint Surg Am. 1986, 68: 937-940.PubMed
4.
go back to reference Hall R, Calvert P: Stress fracture of the acromion: an unusual mechanism and review of the literature. J Bone Joint Surg (Br). 1994, 77: 153-154. Hall R, Calvert P: Stress fracture of the acromion: an unusual mechanism and review of the literature. J Bone Joint Surg (Br). 1994, 77: 153-154.
5.
go back to reference Rask M, Steinberg L: Fracture of the acromion caused by muscle forces. J Bone Joint Surg Am. 1978, 60: 1146-1147.PubMed Rask M, Steinberg L: Fracture of the acromion caused by muscle forces. J Bone Joint Surg Am. 1978, 60: 1146-1147.PubMed
7.
go back to reference Taneja AK, Negromonte FP, Skaf A: Stress injury of the acromion: case report and literature review. Eur J Orthop Surg Traumatol. 2013, 23: S189-S192. 10.1007/s00590-013-1181-6.CrossRefPubMed Taneja AK, Negromonte FP, Skaf A: Stress injury of the acromion: case report and literature review. Eur J Orthop Surg Traumatol. 2013, 23: S189-S192. 10.1007/s00590-013-1181-6.CrossRefPubMed
8.
go back to reference Ward WG, Bergfeld JA, Carson WG: Stress fracture of the base of the acromial process. Am J Sports Med. 1994, 22: 146-147. 10.1177/036354659402200123.CrossRefPubMed Ward WG, Bergfeld JA, Carson WG: Stress fracture of the base of the acromial process. Am J Sports Med. 1994, 22: 146-147. 10.1177/036354659402200123.CrossRefPubMed
9.
go back to reference Warner JJ, Port J: Stress fracture of the acromion. J Shoulder Elbow Surg. 1994, 3: 262-265. 10.1016/S1058-2746(09)80045-1.CrossRefPubMed Warner JJ, Port J: Stress fracture of the acromion. J Shoulder Elbow Surg. 1994, 3: 262-265. 10.1016/S1058-2746(09)80045-1.CrossRefPubMed
10.
go back to reference Wahlquist TC, Hunt AF, Braman JP: Acromial base fractures after reverse total shoulder arthroplasty: report of five cases. J Shoulder Elbow Surg. 2011, 20: 1178-1183. 10.1016/j.jse.2011.01.029.CrossRefPubMed Wahlquist TC, Hunt AF, Braman JP: Acromial base fractures after reverse total shoulder arthroplasty: report of five cases. J Shoulder Elbow Surg. 2011, 20: 1178-1183. 10.1016/j.jse.2011.01.029.CrossRefPubMed
11.
go back to reference As-Sultany M, Tambe A, Clark D: Nonunion of a scapular spine fracture: case report and management with open reduction, internal fixation, and bone graft. Int J Shoulder Surg. 2008, 2: 64-67. 10.4103/0973-6042.42202.CrossRefPubMedPubMedCentral As-Sultany M, Tambe A, Clark D: Nonunion of a scapular spine fracture: case report and management with open reduction, internal fixation, and bone graft. Int J Shoulder Surg. 2008, 2: 64-67. 10.4103/0973-6042.42202.CrossRefPubMedPubMedCentral
12.
go back to reference Ogawa K, Naniwa T: Fractures of the acromion and the lateral scapular spine. J Shoulder Elbow Surg. 1997, 6: 544-548. 10.1016/S1058-2746(97)90087-2.CrossRefPubMed Ogawa K, Naniwa T: Fractures of the acromion and the lateral scapular spine. J Shoulder Elbow Surg. 1997, 6: 544-548. 10.1016/S1058-2746(97)90087-2.CrossRefPubMed
Metadata
Title
A stress fracture of the base of the acromion: a case report
Authors
Eduardo Angeli Malavolta
Jorge Henrique Assunção
Edwin Eiji Sunada
Mauro Emilio Conforto Gracitelli
Arnaldo Amado Ferreira Neto
Publication date
01-12-2014
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2014
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-15-302

Other articles of this Issue 1/2014

BMC Musculoskeletal Disorders 1/2014 Go to the issue