Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2014

Open Access 01-12-2014 | Research article

Motion patterns in activities of daily living: 3- year longitudinal follow-up after total shoulder arthroplasty using an optical 3D motion analysis system

Authors: Michael W Maier, Mirjam Niklasch, Thomas Dreher, Felix Zeifang, Oliver Rettig, Matthias C Klotz, Sebastian I Wolf, Philip Kasten

Published in: BMC Musculoskeletal Disorders | Issue 1/2014

Login to get access

Abstract

Background

Total shoulder arthroplasty (TSA) can improve function in osteoarthritic shoulders, but the ability to perform activities of daily living (ADLs) can still remain impaired. Routinely, shoulder surgeons measure range of motion (ROM) using a goniometer. Objective data are limited, however, concerning functional three-dimensional changes in ROM in ADLs after TSA in patients with degenerative glenohumeral osteoarthritis.

Methods

This study included ten consecutive patients, who received TSA for primary glenohumeral osteoarthritis. The patients were examined the day before, 6 months, and 3 years after shoulder replacement as well. We compared them with a control group (n = 10) without any shoulder pathology and measured shoulder movement by 3D motion analysis using a novel 3 D model. The measurement included static maximum values, the ability to perform and the ROM of the ADLs “combing the hair”, “washing the opposite armpit”, “tying an apron”, and “taking a book from a shelf”.

Results

Six months after surgery, almost all TSA patients were able to perform the four ADLs (3 out of 40 tasks could not be performed by the 10 patients); 3 years postoperatively all patients were able to carry out all ADLs (40 out of 40 tasks possible). In performing the ADLs, comparison of the pre- with the 6-month and 3-year postoperative status of the TSA group showed that the subjects did not fully use the available maximum flexion/extension ROM in performing the four ADLs. The ROM used for flexion/extension did not change significantly (preoperatively 135°-0° -34° vs. 3 years postoperatively 131° -0° -53°). For abduction/adduction, ROM improved significantly from 33°-0° -27° preoperatively to 76° -0° -35° postoperatively. Compared to the controls (118°) the TSA group used less ROM for abduction to perform the four ADLs 3 years postoperatively.

Conclusion

TSA improves the ability to perform ADL and the individual ROM in ADLs in patients with degenerative glenohumeral osteoarthritis over the course of 3 years. However, TSA patients do not use their maximum available abduction ROM in performing ADLs. This is not related to limitations in active ROM, but rather may be caused by pathologic motion patterns, impaired proprioception or both.
Appendix
Available only for authorised users
Literature
1.
go back to reference Orfaly RM, Rockwood CA, Esenyel CZ, Wirth MA: A prospective functional outcome study of shoulder arthroplasty for osteoarthritis with an intact rotator cuff. J Shoulder Elbow Surg. 2003, 12: 214-221. 10.1016/S1058-2746(02)86882-3.CrossRefPubMed Orfaly RM, Rockwood CA, Esenyel CZ, Wirth MA: A prospective functional outcome study of shoulder arthroplasty for osteoarthritis with an intact rotator cuff. J Shoulder Elbow Surg. 2003, 12: 214-221. 10.1016/S1058-2746(02)86882-3.CrossRefPubMed
2.
go back to reference Kasten P, Maier M, Wendy P, Rettig O, Raiss P, Wolf S, Loew M: Can shoulder arthroplasty restore the range of motion in activities of daily living? A prospective 3D video motion analysis study. J Shoulder Elbow Surg. 2010, 19: 59-65. 10.1016/j.jse.2009.10.012.CrossRefPubMed Kasten P, Maier M, Wendy P, Rettig O, Raiss P, Wolf S, Loew M: Can shoulder arthroplasty restore the range of motion in activities of daily living? A prospective 3D video motion analysis study. J Shoulder Elbow Surg. 2010, 19: 59-65. 10.1016/j.jse.2009.10.012.CrossRefPubMed
3.
go back to reference Deshmukh AV, Koris M, Zurakowski D, Thornhill TS: Total shoulder arthroplasty: long-term survivorship, functional outcome, and quality of life. J Shoulder Elbow Surg. 2005, 14: 471-479. 10.1016/j.jse.2005.02.009.CrossRefPubMed Deshmukh AV, Koris M, Zurakowski D, Thornhill TS: Total shoulder arthroplasty: long-term survivorship, functional outcome, and quality of life. J Shoulder Elbow Surg. 2005, 14: 471-479. 10.1016/j.jse.2005.02.009.CrossRefPubMed
4.
go back to reference van de Sande MA, Brand R, Rozing PM: Indications, complications, and results of shoulder arthroplasty. Scand J Rheumatol. 2006, 35: 426-434. 10.1080/03009740600759720.CrossRefPubMed van de Sande MA, Brand R, Rozing PM: Indications, complications, and results of shoulder arthroplasty. Scand J Rheumatol. 2006, 35: 426-434. 10.1080/03009740600759720.CrossRefPubMed
5.
go back to reference Constant CR, Murley AH: A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987, 214: 160-164.PubMed Constant CR, Murley AH: A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987, 214: 160-164.PubMed
6.
go back to reference Goodwin J, Clark C, Deakes J, Burdon D, Lawrence C: Clinical methods of goniometry: a comparative study. Disabil Rehabil. 1992, 14: 10-15. 10.3109/09638289209166420.CrossRefPubMed Goodwin J, Clark C, Deakes J, Burdon D, Lawrence C: Clinical methods of goniometry: a comparative study. Disabil Rehabil. 1992, 14: 10-15. 10.3109/09638289209166420.CrossRefPubMed
7.
go back to reference Rettig O, Fradet L, Kasten P, Raiss P, Wolf SI: A new kinematic model of the upper extremity based on functional joint parameter determination for shoulder and elbow. Gait Posture. 2009, 30: 469-476. 10.1016/j.gaitpost.2009.07.111.CrossRefPubMed Rettig O, Fradet L, Kasten P, Raiss P, Wolf SI: A new kinematic model of the upper extremity based on functional joint parameter determination for shoulder and elbow. Gait Posture. 2009, 30: 469-476. 10.1016/j.gaitpost.2009.07.111.CrossRefPubMed
8.
go back to reference Walch G, Badet R, Boulahia A, Khoury A: Morphologic study of the glenoid in primary glenohumeral osteoarthritis. J Arthroplasty. 1999, 14: 756-760. 10.1016/S0883-5403(99)90232-2.CrossRefPubMed Walch G, Badet R, Boulahia A, Khoury A: Morphologic study of the glenoid in primary glenohumeral osteoarthritis. J Arthroplasty. 1999, 14: 756-760. 10.1016/S0883-5403(99)90232-2.CrossRefPubMed
9.
go back to reference Neer CS: Articular replacement for the humeral head. J Bone Joint Surg Am. 1955, 37-A: 215-228.PubMed Neer CS: Articular replacement for the humeral head. J Bone Joint Surg Am. 1955, 37-A: 215-228.PubMed
10.
go back to reference Rettig O, Maier MW, Gantz S, Raiss P, Zeifang F, Wolf SI: Does the reverse shoulder prosthesis medialize the center of rotation in the glenohumeral joint?. Gait Posture. 2013, 37 (1): 29-31. 10.1016/j.gaitpost.2012.04.019. doi:10.1016/j.gaitpost.2012.04.019. Epub 2012 Aug 2CrossRefPubMed Rettig O, Maier MW, Gantz S, Raiss P, Zeifang F, Wolf SI: Does the reverse shoulder prosthesis medialize the center of rotation in the glenohumeral joint?. Gait Posture. 2013, 37 (1): 29-31. 10.1016/j.gaitpost.2012.04.019. doi:10.1016/j.gaitpost.2012.04.019. Epub 2012 Aug 2CrossRefPubMed
11.
go back to reference Maier MW, Niklasch M, Dreher T, Wolf SI, Zeifang F, Loew M, Kasten P: Proprioception three years after shoulder arthroplasty in 3D motion analysis: a prospective study. Arch Orthop Trauma Surg. 2012, 132 (7): 1003-1010. doi:10.1007/s00402-012-1495-6. Epub 2012 Mar 9CrossRefPubMed Maier MW, Niklasch M, Dreher T, Wolf SI, Zeifang F, Loew M, Kasten P: Proprioception three years after shoulder arthroplasty in 3D motion analysis: a prospective study. Arch Orthop Trauma Surg. 2012, 132 (7): 1003-1010. doi:10.1007/s00402-012-1495-6. Epub 2012 Mar 9CrossRefPubMed
12.
go back to reference Kasten P, Maier M, Rettig O, Raiss P, Wolf S, Loew M: Proprioception in total, hemi- and reverse shoulder arthroplasty in 3D motion analyses: a prospective study. Int Orthop. 2009, 33: 1641-1647. 10.1007/s00264-008-0666-0.CrossRefPubMed Kasten P, Maier M, Rettig O, Raiss P, Wolf S, Loew M: Proprioception in total, hemi- and reverse shoulder arthroplasty in 3D motion analyses: a prospective study. Int Orthop. 2009, 33: 1641-1647. 10.1007/s00264-008-0666-0.CrossRefPubMed
13.
go back to reference Kasten P, Rettig O, Loew M, Wolf S, Raiss P: Three-dimensional motion analysis of compensatory movements in patients with radioulnar synostosis performing activities of daily living. J Orthop Sci. 2009, 14: 307-312. 10.1007/s00776-009-1332-0.CrossRefPubMed Kasten P, Rettig O, Loew M, Wolf S, Raiss P: Three-dimensional motion analysis of compensatory movements in patients with radioulnar synostosis performing activities of daily living. J Orthop Sci. 2009, 14: 307-312. 10.1007/s00776-009-1332-0.CrossRefPubMed
14.
go back to reference Wu G, van der Helm FC, Veeger HE, Makhsous M, Van Roy P, Anglin C, Nagels J, Karduna AR, McQuade K, Wang X, Werner FW, Buchholz B: ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion–Part II: shoulder, elbow, wrist and hand. J Biomech. 2005, 38: 981-992. 10.1016/j.jbiomech.2004.05.042.CrossRefPubMed Wu G, van der Helm FC, Veeger HE, Makhsous M, Van Roy P, Anglin C, Nagels J, Karduna AR, McQuade K, Wang X, Werner FW, Buchholz B: ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion–Part II: shoulder, elbow, wrist and hand. J Biomech. 2005, 38: 981-992. 10.1016/j.jbiomech.2004.05.042.CrossRefPubMed
15.
go back to reference Carman AB, Milburn PD: Determining rigid body transformation parameters from ill-conditioned spatial marker co-ordinates. J Biomech. 2006, 39: 1778-1786. 10.1016/j.jbiomech.2005.05.028.CrossRefPubMed Carman AB, Milburn PD: Determining rigid body transformation parameters from ill-conditioned spatial marker co-ordinates. J Biomech. 2006, 39: 1778-1786. 10.1016/j.jbiomech.2005.05.028.CrossRefPubMed
16.
go back to reference Chiari L, Della Croce U, Leardini A, Cappozzo A: Human movement analysis using stereophotogrammetry. Part 2: instrumental errors. Gait Posture. 2005, 21: 197-211. 10.1016/j.gaitpost.2004.04.004.CrossRefPubMed Chiari L, Della Croce U, Leardini A, Cappozzo A: Human movement analysis using stereophotogrammetry. Part 2: instrumental errors. Gait Posture. 2005, 21: 197-211. 10.1016/j.gaitpost.2004.04.004.CrossRefPubMed
17.
go back to reference Doorenbosch CA, Harlaar J, Veeger DH: The globe system: an unambiguous description of shoulder positions in daily life movements. J Rehabil Res Dev. 2003, 40: 147-155.CrossRefPubMed Doorenbosch CA, Harlaar J, Veeger DH: The globe system: an unambiguous description of shoulder positions in daily life movements. J Rehabil Res Dev. 2003, 40: 147-155.CrossRefPubMed
18.
go back to reference Armstrong AD, MacDermid JC, Chinchalkar S, Stevens RS, King GJ: Reliability of range-of-motion measurement in the elbow and forearm. J Shoulder Elbow Surg. 1998, 7: 573-580. 10.1016/S1058-2746(98)90003-9.CrossRefPubMed Armstrong AD, MacDermid JC, Chinchalkar S, Stevens RS, King GJ: Reliability of range-of-motion measurement in the elbow and forearm. J Shoulder Elbow Surg. 1998, 7: 573-580. 10.1016/S1058-2746(98)90003-9.CrossRefPubMed
19.
go back to reference Boone DC, Azen SP, Lin CM, Spence C, Baron C, Lee L: Reliability of goniometric measurements. Phys Ther. 1978, 58: 1355-1390.PubMed Boone DC, Azen SP, Lin CM, Spence C, Baron C, Lee L: Reliability of goniometric measurements. Phys Ther. 1978, 58: 1355-1390.PubMed
20.
go back to reference Carey MA, Laird DE, Murray KA, Stevenson JR: Reliability, validity, and clinical usability of a digital goniometer. Work. 2010, 36: 55-66.PubMed Carey MA, Laird DE, Murray KA, Stevenson JR: Reliability, validity, and clinical usability of a digital goniometer. Work. 2010, 36: 55-66.PubMed
21.
go back to reference Flowers KR, Stephens-Chisar J, LaStayo P, Galante BL: Intrarater reliability of a new method and instrumentation for measuring passive supination and pronation: a preliminary study. J Hand Ther. 2001, 14: 30-35. 10.1016/S0894-1130(01)80022-3.CrossRefPubMed Flowers KR, Stephens-Chisar J, LaStayo P, Galante BL: Intrarater reliability of a new method and instrumentation for measuring passive supination and pronation: a preliminary study. J Hand Ther. 2001, 14: 30-35. 10.1016/S0894-1130(01)80022-3.CrossRefPubMed
22.
go back to reference Gunal I, Kose N, Erdogan O, Gokturk E, Seber S: Normal range of motion of the joints of the upper extremity in male subjects, with special reference to side. J Bone Joint Surg Am. 1996, 78: 1401-1404.PubMed Gunal I, Kose N, Erdogan O, Gokturk E, Seber S: Normal range of motion of the joints of the upper extremity in male subjects, with special reference to side. J Bone Joint Surg Am. 1996, 78: 1401-1404.PubMed
23.
go back to reference Johnson K: Closing in on the neural mechanisms of finger joint angle sense. Focus on “Quantitative analysis of dynamic strain sensitivity in human skin mechanoreceptors”. J Neurophysiol. 2004, 92: 3167-3168. 10.1152/jn.00724.2004.CrossRefPubMed Johnson K: Closing in on the neural mechanisms of finger joint angle sense. Focus on “Quantitative analysis of dynamic strain sensitivity in human skin mechanoreceptors”. J Neurophysiol. 2004, 92: 3167-3168. 10.1152/jn.00724.2004.CrossRefPubMed
24.
go back to reference Kolber MJ, Saltzman SB, Beekhuizen KS, Cheng MS: Reliability and minimal detectable change of inclinometric shoulder mobility measurements. Physiother Theory Pract. 2009, 25: 572-581. 10.3109/09593980802667995.CrossRefPubMed Kolber MJ, Saltzman SB, Beekhuizen KS, Cheng MS: Reliability and minimal detectable change of inclinometric shoulder mobility measurements. Physiother Theory Pract. 2009, 25: 572-581. 10.3109/09593980802667995.CrossRefPubMed
25.
go back to reference Kolber MJ, Vega F, Widmayer K, Cheng MS: The reliability and minimal detectable change of shoulder mobility measurements using a digital inclinometer. Physiother Theory Pract. 2011, 27: 176-184. 10.3109/09593985.2010.481011.CrossRefPubMed Kolber MJ, Vega F, Widmayer K, Cheng MS: The reliability and minimal detectable change of shoulder mobility measurements using a digital inclinometer. Physiother Theory Pract. 2011, 27: 176-184. 10.3109/09593985.2010.481011.CrossRefPubMed
26.
go back to reference Urban V, Kalberer F, Roos M, Dumont CE: Reliability of active range-of-motion measurement of the rotation in the forearm: comparison of three measurement devices. Z Orthop Ihre Grenzgeb. 2002, 140: 72-76. 10.1055/s-2002-22094.CrossRefPubMed Urban V, Kalberer F, Roos M, Dumont CE: Reliability of active range-of-motion measurement of the rotation in the forearm: comparison of three measurement devices. Z Orthop Ihre Grenzgeb. 2002, 140: 72-76. 10.1055/s-2002-22094.CrossRefPubMed
27.
go back to reference Mullaney MJ, McHugh MP, Johnson CP, Tyler TF: Reliability of shoulder range of motion comparing a goniometer to a digital level. Physiother Theory Pract. 2010, 26: 327-333. 10.3109/09593980903094230.CrossRefPubMed Mullaney MJ, McHugh MP, Johnson CP, Tyler TF: Reliability of shoulder range of motion comparing a goniometer to a digital level. Physiother Theory Pract. 2010, 26: 327-333. 10.3109/09593980903094230.CrossRefPubMed
28.
go back to reference Constant CR: An evaluation of the Constant-Murley shoulder assessment. J Bone Joint Surg Br. 1997, 79: 695-696.PubMed Constant CR: An evaluation of the Constant-Murley shoulder assessment. J Bone Joint Surg Br. 1997, 79: 695-696.PubMed
29.
go back to reference Constant CR, Gerber C, Emery RJ, Sojbjerg JO, Gohlke F, Boileau P: A review of the Constant score: modifications and guidelines for its use. J Shoulder Elbow Surg. 2008, 17: 355-361. 10.1016/j.jse.2007.06.022.CrossRefPubMed Constant CR, Gerber C, Emery RJ, Sojbjerg JO, Gohlke F, Boileau P: A review of the Constant score: modifications and guidelines for its use. J Shoulder Elbow Surg. 2008, 17: 355-361. 10.1016/j.jse.2007.06.022.CrossRefPubMed
30.
go back to reference Magermans DJ, Chadwick EK, Veeger HE, van der Helm FC: Requirements for upper extremity motions during activities of daily living. Clin Biomech (Bristol, Avon). 2005, 20: 591-599. 10.1016/j.clinbiomech.2005.02.006.CrossRef Magermans DJ, Chadwick EK, Veeger HE, van der Helm FC: Requirements for upper extremity motions during activities of daily living. Clin Biomech (Bristol, Avon). 2005, 20: 591-599. 10.1016/j.clinbiomech.2005.02.006.CrossRef
31.
go back to reference Veeger HE, Magermans DJ, Nagels J, Chadwick EK, Van der Helm FC: A kinematical analysis of the shoulder after arthroplasty during a hair combing task. Clin Biomech (Bristol, Avon). 2006, 21 (Suppl 1): S39-S44.CrossRef Veeger HE, Magermans DJ, Nagels J, Chadwick EK, Van der Helm FC: A kinematical analysis of the shoulder after arthroplasty during a hair combing task. Clin Biomech (Bristol, Avon). 2006, 21 (Suppl 1): S39-S44.CrossRef
Metadata
Title
Motion patterns in activities of daily living: 3- year longitudinal follow-up after total shoulder arthroplasty using an optical 3D motion analysis system
Authors
Michael W Maier
Mirjam Niklasch
Thomas Dreher
Felix Zeifang
Oliver Rettig
Matthias C Klotz
Sebastian I Wolf
Philip Kasten
Publication date
01-12-2014
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2014
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-15-244

Other articles of this Issue 1/2014

BMC Musculoskeletal Disorders 1/2014 Go to the issue