Abstract

Background

Reproducible and suitable animal models are required for in vivo experiments to investigate new biodegradable and osteoinductive biomaterials for augmentation of bones at risk for osteoporotic fractures. Sheep have especially been used as a model for the human spine due to their size and similar bone metabolism. However, although sheep and human vertebral bodies have similar biomechanical characteristics, the shape of the vertebral bodies, the size of the transverse processes, and the different orientation of the facet joints of sheep are quite different from those of humans making the surgical approach complicated and unpredictable. Therefore, an adequate and safe animal model for bone augmentation was developed using a standardized femoral and tibia augmentation site in sheep.

Methods

The cancellous bone of the distal femur and proximal tibia were chosen as injection sites with the surgical approach via the medial aspects of the femoral condyle and proximal tibia metaphysis (n = 4 injection sites). For reproducible drilling and injection in a given direction and length, a custom-made c-shaped aiming device was designed. Exact positioning of the aiming device and needle positioning within the intertrabecular space of the intact bone could be validated in a predictable and standardized fashion using fluoroscopy. After sacrifice, bone cylinders (∅ 32 mm) were harvested throughout the tibia and femur by means of a diamond-coated core drill, which was especially developed to harvest the injected bone area exactly. Thereafter, the extracted bone cylinders were processed as non-decalcified specimens for μCT analysis, histomorphometry, histology, and fluorescence evaluation.

Results

The aiming device could be easily placed in 63 sheep and assured a reproducible, standardized injection area. In four sheep, cardiovascular complications occurred during surgery and pulmonary embolism was detected by computed tomography post surgery in all of these animals. The harvesting and evaluative methods assured a standardized analysis of all samples.

Conclusions

This experimental animal model provides an excellent basis for testing new biomaterials for their suitability as bone augmentation materials. Concomitantly, similar cardiovascular changes occur during vertebroplasties as in humans, thus making it a suitable animal model for studies related to vertebroplasty.
Appendix
Available only for authorised users
Literature
1.
go back to reference Turner RT, Maran A, Lotinun S, Hefferan T, Evans GL, Zhang M, Sibonga JD: Animal models for osteoporosis. Rev Endocr Metab Disord. 2001, 2: 117-127. 10.1023/A:1010067326811.CrossRefPubMed Turner RT, Maran A, Lotinun S, Hefferan T, Evans GL, Zhang M, Sibonga JD: Animal models for osteoporosis. Rev Endocr Metab Disord. 2001, 2: 117-127. 10.1023/A:1010067326811.CrossRefPubMed
2.
go back to reference Zhu XS, Zhang ZM, Mao HQ, Geng DC, Zou J, Wang GL, Zhang ZG, Wang JH, Chen L, Yang HL: A novel sheep vertebral bone defect model for injectable bioactive vertebral augmentation materials. J Mater Sci Mater Med. 2011, 22: 159-164. 10.1007/s10856-010-4191-5.CrossRefPubMed Zhu XS, Zhang ZM, Mao HQ, Geng DC, Zou J, Wang GL, Zhang ZG, Wang JH, Chen L, Yang HL: A novel sheep vertebral bone defect model for injectable bioactive vertebral augmentation materials. J Mater Sci Mater Med. 2011, 22: 159-164. 10.1007/s10856-010-4191-5.CrossRefPubMed
3.
go back to reference Galovich LA, Perez-Higueras A, Altonaga JR, Orden JM, Barba ML, Morillo MT: Biomechanical, histological and histomorphometric analyses of calcium phosphate cement compared to PMMA for vertebral augmentation in a validated animal model. Eur Spine J. 2011, 20 (Suppl 3): 376-382.CrossRefPubMedPubMedCentral Galovich LA, Perez-Higueras A, Altonaga JR, Orden JM, Barba ML, Morillo MT: Biomechanical, histological and histomorphometric analyses of calcium phosphate cement compared to PMMA for vertebral augmentation in a validated animal model. Eur Spine J. 2011, 20 (Suppl 3): 376-382.CrossRefPubMedPubMedCentral
4.
go back to reference Cotten A, Boutry N, Cortet B, Assaker R, Demondion X, Leblond D, Chastanet P, Duquesnoy B, Deramond H: Percutaneous vertebroplasty: state of the art. Radiographics. 1998, 18: 311-320. discussion 320–313CrossRefPubMed Cotten A, Boutry N, Cortet B, Assaker R, Demondion X, Leblond D, Chastanet P, Duquesnoy B, Deramond H: Percutaneous vertebroplasty: state of the art. Radiographics. 1998, 18: 311-320. discussion 320–313CrossRefPubMed
5.
go back to reference Benneker LM, Gisep A, Krebs J, Boger A, Heini PF, Boner V: Development of an in vivo experimental model for percutaneous vertebroplasty in sheep. Vet Comp Orthop Traumatol. 2012, 25: 173-177. 10.3415/VCOT-11-02-0026.CrossRefPubMed Benneker LM, Gisep A, Krebs J, Boger A, Heini PF, Boner V: Development of an in vivo experimental model for percutaneous vertebroplasty in sheep. Vet Comp Orthop Traumatol. 2012, 25: 173-177. 10.3415/VCOT-11-02-0026.CrossRefPubMed
6.
go back to reference Krebs J, Ferguson SJ, Hoerstrup SP, Goss BG, Haeberli A, Aebli N: Influence of bone marrow fat embolism on coagulation activation in an ovine model of vertebroplasty. J Bone Joint Surg Am. 2008, 90: 349-356. 10.2106/JBJS.G.00058.CrossRefPubMed Krebs J, Ferguson SJ, Hoerstrup SP, Goss BG, Haeberli A, Aebli N: Influence of bone marrow fat embolism on coagulation activation in an ovine model of vertebroplasty. J Bone Joint Surg Am. 2008, 90: 349-356. 10.2106/JBJS.G.00058.CrossRefPubMed
7.
go back to reference Krebs J, Ferguson SJ, Nuss K, Leskosek B, Hoerstrup SP, Goss BG, Shaw S, Aebli N: Plasma levels of endothelin-1 after a pulmonary embolism of bone marrow fat. Acta Anaesthesiol Scand. 2007, 51: 1107-1114. 10.1111/j.1399-6576.2007.01369.x.CrossRefPubMed Krebs J, Ferguson SJ, Nuss K, Leskosek B, Hoerstrup SP, Goss BG, Shaw S, Aebli N: Plasma levels of endothelin-1 after a pulmonary embolism of bone marrow fat. Acta Anaesthesiol Scand. 2007, 51: 1107-1114. 10.1111/j.1399-6576.2007.01369.x.CrossRefPubMed
8.
go back to reference Aebli N, Krebs J, Schwenke D, Davis G, Theis JC, Aebli N, Krebs J, Schwenke D, Davis G, Theis JC: Cardiovascular changes during multiple vertebroplasty with and without vent-hole: an experimental study in sheep. Spine (Phila Pa 1976). 2003, 28: 1504-1511. discussion 1511–1502 Aebli N, Krebs J, Schwenke D, Davis G, Theis JC, Aebli N, Krebs J, Schwenke D, Davis G, Theis JC: Cardiovascular changes during multiple vertebroplasty with and without vent-hole: an experimental study in sheep. Spine (Phila Pa 1976). 2003, 28: 1504-1511. discussion 1511–1502
9.
go back to reference Boger A, Benneker LM, Krebs J, Boner V, Heini PF, Gisep A: The effect of pulsed jet lavage in vertebroplasty on injection forces of PMMA bone cement: an animal study. Eur Spine J. 2009, 18: 1957-1962. 10.1007/s00586-009-1079-5.CrossRefPubMedPubMedCentral Boger A, Benneker LM, Krebs J, Boner V, Heini PF, Gisep A: The effect of pulsed jet lavage in vertebroplasty on injection forces of PMMA bone cement: an animal study. Eur Spine J. 2009, 18: 1957-1962. 10.1007/s00586-009-1079-5.CrossRefPubMedPubMedCentral
10.
go back to reference Aebli N, Krebs J, Davis G, Walton M, Williams MJ, Theis JC: Fat embolism and acute hypotension during vertebroplasty: an experimental study in sheep. Spine (Phila Pa 1976). 2002, 27: 460-466. 10.1097/00007632-200203010-00005.CrossRef Aebli N, Krebs J, Davis G, Walton M, Williams MJ, Theis JC: Fat embolism and acute hypotension during vertebroplasty: an experimental study in sheep. Spine (Phila Pa 1976). 2002, 27: 460-466. 10.1097/00007632-200203010-00005.CrossRef
11.
go back to reference Aebli N, Krebs J, Schwenke D, Davis G, Theis JC, Aebli N, Krebs J, Schwenke D, Davis G, Theis JC: Pressurization of vertebral bodies during vertebroplasty causes cardiovascular complications: an experimental study in sheep. Spine (Phila Pa 1976). 2003, 28: 1513-1519. discussion 1519–1520 Aebli N, Krebs J, Schwenke D, Davis G, Theis JC, Aebli N, Krebs J, Schwenke D, Davis G, Theis JC: Pressurization of vertebral bodies during vertebroplasty causes cardiovascular complications: an experimental study in sheep. Spine (Phila Pa 1976). 2003, 28: 1513-1519. discussion 1519–1520
12.
go back to reference Rapado A: General management of vertebral fractures. Bone. 1996, 18: 191S-196S. 10.1016/8756-3282(95)00501-3.CrossRefPubMed Rapado A: General management of vertebral fractures. Bone. 1996, 18: 191S-196S. 10.1016/8756-3282(95)00501-3.CrossRefPubMed
13.
go back to reference Old JL, Calvert M: Vertebral compression fractures in the elderly. Am Fam Physician. 2004, 69: 111-116.PubMed Old JL, Calvert M: Vertebral compression fractures in the elderly. Am Fam Physician. 2004, 69: 111-116.PubMed
14.
go back to reference Lewis G: Percutaneous vertebroplasty and kyphoplasty for the stand-alone augmentation of osteoporosis-induced vertebral compression fractures: present status and future directions. J Biomed Mater Res B Appl Biomater. 2007, 81: 371-386.CrossRefPubMed Lewis G: Percutaneous vertebroplasty and kyphoplasty for the stand-alone augmentation of osteoporosis-induced vertebral compression fractures: present status and future directions. J Biomed Mater Res B Appl Biomater. 2007, 81: 371-386.CrossRefPubMed
15.
go back to reference Lavelle W, Carl A, Lavelle ED, Khaleel MA: Vertebroplasty and kyphoplasty. Anesthesiol Clin. 2007, 25: 913-928. 10.1016/j.anclin.2007.07.011.CrossRefPubMed Lavelle W, Carl A, Lavelle ED, Khaleel MA: Vertebroplasty and kyphoplasty. Anesthesiol Clin. 2007, 25: 913-928. 10.1016/j.anclin.2007.07.011.CrossRefPubMed
16.
go back to reference Hulme PA, Krebs J, Ferguson SJ, Berlemann U, Hulme PA, Krebs J, Ferguson SJ, Berlemann U: Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies. Spine (Phila Pa 1976). 2006, 31: 1983-2001. 10.1097/01.brs.0000229254.89952.6b.CrossRef Hulme PA, Krebs J, Ferguson SJ, Berlemann U, Hulme PA, Krebs J, Ferguson SJ, Berlemann U: Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies. Spine (Phila Pa 1976). 2006, 31: 1983-2001. 10.1097/01.brs.0000229254.89952.6b.CrossRef
17.
go back to reference Garfin SR, Yuan HA, Reiley MA: New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures. Spine (Phila Pa 1976). 2001, 26: 1511-1515. 10.1097/00007632-200107150-00002.CrossRef Garfin SR, Yuan HA, Reiley MA: New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures. Spine (Phila Pa 1976). 2001, 26: 1511-1515. 10.1097/00007632-200107150-00002.CrossRef
18.
go back to reference Lemke DM: Vertebroplasty and kyphoplasty for treatment of painful osteoporotic compression fractures. J Am Acad Nurse Pract. 2005, 17: 268-276. 10.1111/j.1745-7599.2005.0045.x.CrossRefPubMed Lemke DM: Vertebroplasty and kyphoplasty for treatment of painful osteoporotic compression fractures. J Am Acad Nurse Pract. 2005, 17: 268-276. 10.1111/j.1745-7599.2005.0045.x.CrossRefPubMed
19.
go back to reference Phillips FM, Pfeifer BA, Lieberman IH, Kerr EJ, Choi IS, Pazianos AG: Minimally invasive treatments of osteoporotic vertebral compression fractures: vertebroplasty and kyphoplasty. Instr Course Lect. 2003, 52: 559-567.PubMed Phillips FM, Pfeifer BA, Lieberman IH, Kerr EJ, Choi IS, Pazianos AG: Minimally invasive treatments of osteoporotic vertebral compression fractures: vertebroplasty and kyphoplasty. Instr Course Lect. 2003, 52: 559-567.PubMed
20.
go back to reference Wilke HJ, Kettler A, Wenger KH, Claes LE: Anatomy of the sheep spine and its comparison to the human spine. Anat Rec. 1997, 247: 542-555. 10.1002/(SICI)1097-0185(199704)247:4<542::AID-AR13>3.0.CO;2-P.CrossRefPubMed Wilke HJ, Kettler A, Wenger KH, Claes LE: Anatomy of the sheep spine and its comparison to the human spine. Anat Rec. 1997, 247: 542-555. 10.1002/(SICI)1097-0185(199704)247:4<542::AID-AR13>3.0.CO;2-P.CrossRefPubMed
21.
go back to reference Wilke HJ, Kettler A, Claes LE: Are sheep spines a valid biomechanical model for human spines?. Spine (Phila Pa 1976). 1997, 22: 2365-2374. 10.1097/00007632-199710150-00009.CrossRef Wilke HJ, Kettler A, Claes LE: Are sheep spines a valid biomechanical model for human spines?. Spine (Phila Pa 1976). 1997, 22: 2365-2374. 10.1097/00007632-199710150-00009.CrossRef
22.
go back to reference Turner AS: The sheep as a model for osteoporosis in humans. Vet J. 2002, 163: 232-239. 10.1053/tvjl.2001.0642.CrossRefPubMed Turner AS: The sheep as a model for osteoporosis in humans. Vet J. 2002, 163: 232-239. 10.1053/tvjl.2001.0642.CrossRefPubMed
23.
go back to reference Hildebrand T, Laib A, Muller R, Dequeker J, Ruegsegger P: Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus. J Bone Miner Res. 1999, 14: 1167-1174. 10.1359/jbmr.1999.14.7.1167.CrossRefPubMed Hildebrand T, Laib A, Muller R, Dequeker J, Ruegsegger P: Direct three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus. J Bone Miner Res. 1999, 14: 1167-1174. 10.1359/jbmr.1999.14.7.1167.CrossRefPubMed
24.
go back to reference Rubin C, Turner AS, Muller R, Mittra E, McLeod K, Lin W, Qin YX: Quantity and quality of trabecular bone in the femur are enhanced by a strongly anabolic, noninvasive mechanical intervention. J Bone Miner Res. 2002, 17: 349-357. 10.1359/jbmr.2002.17.2.349.CrossRefPubMed Rubin C, Turner AS, Muller R, Mittra E, McLeod K, Lin W, Qin YX: Quantity and quality of trabecular bone in the femur are enhanced by a strongly anabolic, noninvasive mechanical intervention. J Bone Miner Res. 2002, 17: 349-357. 10.1359/jbmr.2002.17.2.349.CrossRefPubMed
25.
go back to reference Moreland DB, Landi MK, Grand W: Vertebroplasty: techniques to avoid complications. Spine J. 2001, 1: 66-71. 10.1016/S1529-9430(01)00013-4.CrossRefPubMed Moreland DB, Landi MK, Grand W: Vertebroplasty: techniques to avoid complications. Spine J. 2001, 1: 66-71. 10.1016/S1529-9430(01)00013-4.CrossRefPubMed
26.
go back to reference Benneker LM, Heini PF, Suhm N, Gisep A, Benneker LM, Heini PF, Suhm N, Gisep A: The effect of pulsed jet lavage in vertebroplasty on injection forces of polymethylmethacrylate bone cement, material distribution, and potential fat embolism: a cadaver study. Spine (Phila Pa 1976). 2008, 33: E906-E910. 10.1097/BRS.0b013e318183bb6d. Benneker LM, Heini PF, Suhm N, Gisep A, Benneker LM, Heini PF, Suhm N, Gisep A: The effect of pulsed jet lavage in vertebroplasty on injection forces of polymethylmethacrylate bone cement, material distribution, and potential fat embolism: a cadaver study. Spine (Phila Pa 1976). 2008, 33: E906-E910. 10.1097/BRS.0b013e318183bb6d.
27.
go back to reference Phillips FM, Todd Wetzel F, Lieberman I, Campbell-Hupp M, Phillips FM, Todd Wetzel F, Lieberman I, Campbell-Hupp M: An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty. Spine (Phila Pa 1976). 2002, 27: 2173-2178. 10.1097/00007632-200210010-00018. discussion 2178–2179CrossRef Phillips FM, Todd Wetzel F, Lieberman I, Campbell-Hupp M, Phillips FM, Todd Wetzel F, Lieberman I, Campbell-Hupp M: An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty. Spine (Phila Pa 1976). 2002, 27: 2173-2178. 10.1097/00007632-200210010-00018. discussion 2178–2179CrossRef
28.
go back to reference Yeom JS, Kim WJ, Choy WS, Lee CK, Chang BS, Kang JW: Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. J Bone Joint Surg Br. 2003, 85: 83-89. 10.1302/0301-620X.85B1.13026.CrossRefPubMed Yeom JS, Kim WJ, Choy WS, Lee CK, Chang BS, Kang JW: Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. J Bone Joint Surg Br. 2003, 85: 83-89. 10.1302/0301-620X.85B1.13026.CrossRefPubMed
29.
go back to reference Schmidt R, Cakir B, Mattes T, Wegener M, Puhl W, Richter M: Cement leakage during vertebroplasty: an underestimated problem?. Eur Spine J. 2005, 14: 466-473. 10.1007/s00586-004-0839-5.CrossRefPubMedPubMedCentral Schmidt R, Cakir B, Mattes T, Wegener M, Puhl W, Richter M: Cement leakage during vertebroplasty: an underestimated problem?. Eur Spine J. 2005, 14: 466-473. 10.1007/s00586-004-0839-5.CrossRefPubMedPubMedCentral
30.
go back to reference Rodan GA, Martin TJ: Therapeutic approaches to bone diseases. Science. 2000, 289: 1508-1514. 10.1126/science.289.5484.1508.CrossRefPubMed Rodan GA, Martin TJ: Therapeutic approaches to bone diseases. Science. 2000, 289: 1508-1514. 10.1126/science.289.5484.1508.CrossRefPubMed
Metadata
Title
Bone augmentation for cancellous bone-development of a new animal model
Authors
Karina Klein
Enrico Zamparo
Peter W Kronen
Katharina Kämpf
Mariano Makara
Thomas Steffen
Brigitte von Rechenberg
Publication date
01-12-2013
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2013
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-14-200

Other articles of this Issue 1/2013

BMC Musculoskeletal Disorders 1/2013 Go to the issue