Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2011

Open Access 01-12-2011 | Research article

Comparison between two pedicle screw augmentation instrumentations in adult degenerative scoliosis with osteoporosis

Authors: Yang Xie, Qiang Fu, Zi-qiang Chen, Zhi-cai Shi, Xiao-dong Zhu, Chuan-feng Wang, Ming Li

Published in: BMC Musculoskeletal Disorders | Issue 1/2011

Login to get access

Abstract

Background

The operative treatment of adult degenerative scoliosis combined with osteoporosis increase following the epidemiological development. Studies have confirmed that screws in osteoporotic spines have significant lower-screw strength with more frequent screw movements within the vertebra than normal spines. Screws augmented with Polymethylmethacrylate (PMMA) or with autogenous bone can offer more powerful corrective force and significant advantages.

Methods

A retrospective analysis was conducted on 31 consecutive patients with degenerative lumbar scoliosis combined with osteoporosis who had surgery from December 2000. All had a minimum of 2-year follow-up. All patients had posterior approach surgery. 14 of them were fixed with pedicle screw by augmentation with Polymethylmethacrylate (PMMA) and the other 17 patients with autogenous bone. Age, sex and whether smoking were similar between the two groups. Surgical time, blood loss, blood transfusion, medical cost, post surgery ICU time, hospital day, length of oral pain medicines taken, Pre-and postoperative Oswestry disability index questionnaire and surgical revision were documented and compared. Preoperative, postoperative and final follow up Cobb angle, sagittal lumbar curve, correction rate, and Follow up Cobb loss were also compared.

Results

No significant differences were found between the autogenous bone group and Polymethylmethacrylate group with regards to all the targets above except for length of oral pain medicines taken and surgery cost. 2 patients were seen leakage during operation, but there is neither damage of nerve nor symptom after operation. No revision was needed.

Conclusion

Both augmentation pedicle screw with Polymethylmethacrylate (PMMA) and autogenous bone treating degenerative lumbar scoliosis combined with osteoporosis can achieve a good surgical result. Less oral pain medicines taken are the potential benefits of Polymethylmethacrylate augmentation, but that is at the cost of more medical spending.
Appendix
Available only for authorised users
Literature
1.
go back to reference Tribus CB: Degenerative lumbar scoliosis: evaluation and management. J Am Acad Orthop Surg. 2003, 11 (3): 174-183.CrossRefPubMed Tribus CB: Degenerative lumbar scoliosis: evaluation and management. J Am Acad Orthop Surg. 2003, 11 (3): 174-183.CrossRefPubMed
2.
go back to reference Birknes JK, White AP, Albert TJ, Shaffrey CI, Harrop JS: Adult degenerative scoliosis: a review. Neurosurgery. 2008, 63 (3 Suppl): 94-103.CrossRefPubMed Birknes JK, White AP, Albert TJ, Shaffrey CI, Harrop JS: Adult degenerative scoliosis: a review. Neurosurgery. 2008, 63 (3 Suppl): 94-103.CrossRefPubMed
3.
go back to reference Farfan HF, Huberdeau RM, Dubow HI: Lumbar intervertebral disc degeneration: the influence of geometrical features on the pattern of disc degeneration--a post mortem study. J Bone Joint Surg Am. 1972, 54 (3): 492-510.PubMed Farfan HF, Huberdeau RM, Dubow HI: Lumbar intervertebral disc degeneration: the influence of geometrical features on the pattern of disc degeneration--a post mortem study. J Bone Joint Surg Am. 1972, 54 (3): 492-510.PubMed
4.
go back to reference Grubb SA, Lipscomb HJ, Coonrad RW: Degenerative adult onset scoliosis. Spine (Phila Pa 1976). 1988, 13 (3): 241-245. 10.1097/00007632-198803000-00004.CrossRef Grubb SA, Lipscomb HJ, Coonrad RW: Degenerative adult onset scoliosis. Spine (Phila Pa 1976). 1988, 13 (3): 241-245. 10.1097/00007632-198803000-00004.CrossRef
5.
go back to reference Pritchett JW, Bortel DT: Degenerative symptomatic lumbar scoliosis. Spine (Phila Pa 1976). 1993, 18 (6): 700-703. 10.1097/00007632-199305000-00004.CrossRef Pritchett JW, Bortel DT: Degenerative symptomatic lumbar scoliosis. Spine (Phila Pa 1976). 1993, 18 (6): 700-703. 10.1097/00007632-199305000-00004.CrossRef
6.
go back to reference Kirkaldy-Willis WH, Farfan HF: Instability of the lumbar spine. Clin Orthop Relat Res. 1982, 110-123. 165 Kirkaldy-Willis WH, Farfan HF: Instability of the lumbar spine. Clin Orthop Relat Res. 1982, 110-123. 165
7.
go back to reference Daffner SD, Vaccaro AR: Adult degenerative lumbar scoliosis. Am J Orthop (Belle Mead NJ). 2003, 32 (2): 77-82. discussion 82 Daffner SD, Vaccaro AR: Adult degenerative lumbar scoliosis. Am J Orthop (Belle Mead NJ). 2003, 32 (2): 77-82. discussion 82
8.
go back to reference Fraser JF, Huang RC, Girardi FP, Cammisa FP: Pathogenesis, presentation, and treatment of lumbar spinal stenosis associated with coronal or sagittal spinal deformities. Neurosurg Focus. 2003, 14 (1): e6-CrossRefPubMed Fraser JF, Huang RC, Girardi FP, Cammisa FP: Pathogenesis, presentation, and treatment of lumbar spinal stenosis associated with coronal or sagittal spinal deformities. Neurosurg Focus. 2003, 14 (1): e6-CrossRefPubMed
9.
10.
go back to reference Simmons ED: Surgical treatment of patients with lumbar spinal stenosis with associated scoliosis. Clin Orthop Relat Res. 2001, 45-53. 384 Simmons ED: Surgical treatment of patients with lumbar spinal stenosis with associated scoliosis. Clin Orthop Relat Res. 2001, 45-53. 384
11.
go back to reference Narayan P, Haid RW, Subach BR, Comey CH, Rodts GE: Effect of spinal disease on successful arthrodesis in lumbar pedicle screw fixation. J Neurosurg. 2002, 97 (3 Suppl): 277-280.PubMed Narayan P, Haid RW, Subach BR, Comey CH, Rodts GE: Effect of spinal disease on successful arthrodesis in lumbar pedicle screw fixation. J Neurosurg. 2002, 97 (3 Suppl): 277-280.PubMed
12.
go back to reference Hirano T, Hasegawa K, Takahashi HE, Uchiyama S, Hara T, Washio T, Sugiura T, Yokaichiya M, Ikeda M: Structural characteristics of the pedicle and its role in screw stability. Spine (Phila Pa 1976). 1997, 22 (21): 2504-2509. 10.1097/00007632-199711010-00007. discussion 2510CrossRef Hirano T, Hasegawa K, Takahashi HE, Uchiyama S, Hara T, Washio T, Sugiura T, Yokaichiya M, Ikeda M: Structural characteristics of the pedicle and its role in screw stability. Spine (Phila Pa 1976). 1997, 22 (21): 2504-2509. 10.1097/00007632-199711010-00007. discussion 2510CrossRef
13.
go back to reference Frankel BM, Jones T, Wang C: Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery. 2007, 61 (3): 531-537. 10.1227/01.NEU.0000290899.15567.68. discussion 537-538CrossRefPubMed Frankel BM, Jones T, Wang C: Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery. 2007, 61 (3): 531-537. 10.1227/01.NEU.0000290899.15567.68. discussion 537-538CrossRefPubMed
14.
go back to reference Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB: Complications associated with pedicle screws. J Bone Joint Surg Am. 1999, 81 (11): 1519-1528.PubMed Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB: Complications associated with pedicle screws. J Bone Joint Surg Am. 1999, 81 (11): 1519-1528.PubMed
15.
go back to reference Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS, Cook SD: Effects of bone mineral density on pedicle screw fixation. Spine (Phila Pa 1976). 1994, 19 (21): 2415-2420. 10.1097/00007632-199411000-00008.CrossRef Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS, Cook SD: Effects of bone mineral density on pedicle screw fixation. Spine (Phila Pa 1976). 1994, 19 (21): 2415-2420. 10.1097/00007632-199411000-00008.CrossRef
16.
go back to reference McLain RF, McKinley TO, Yerby SA, Smith TS, Sarigul-Klijn N: The effect of bone quality on pedicle screw loading in axial instability. A synthetic model. Spine (Phila Pa 1976). 1997, 22 (13): 1454-1460. 10.1097/00007632-199707010-00006.CrossRef McLain RF, McKinley TO, Yerby SA, Smith TS, Sarigul-Klijn N: The effect of bone quality on pedicle screw loading in axial instability. A synthetic model. Spine (Phila Pa 1976). 1997, 22 (13): 1454-1460. 10.1097/00007632-199707010-00006.CrossRef
17.
go back to reference Burval DJ, McLain RF, Milks R, Inceoglu S: Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength. Spine (Phila Pa 1976). 2007, 32 (10): 1077-1083. 10.1097/01.brs.0000261566.38422.40.CrossRef Burval DJ, McLain RF, Milks R, Inceoglu S: Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength. Spine (Phila Pa 1976). 2007, 32 (10): 1077-1083. 10.1097/01.brs.0000261566.38422.40.CrossRef
18.
go back to reference Taniwaki Y, Takemasa R, Tani T, Mizobuchi H, Yamamoto H: Enhancement of pedicle screw stability using calcium phosphate cement in osteoporotic vertebrae: in vivo biomechanical study. J Orthop Sci. 2003, 8 (3): 408-414. 10.1007/s10776-003-0639-6.CrossRefPubMed Taniwaki Y, Takemasa R, Tani T, Mizobuchi H, Yamamoto H: Enhancement of pedicle screw stability using calcium phosphate cement in osteoporotic vertebrae: in vivo biomechanical study. J Orthop Sci. 2003, 8 (3): 408-414. 10.1007/s10776-003-0639-6.CrossRefPubMed
19.
go back to reference Yerby SA, Toh E, McLain RF: Revision of failed pedicle screws using hydroxyapatite cement. A biomechanical analysis. Spine (Phila Pa 1976). 1998, 23 (15): 1657-1661. 10.1097/00007632-199808010-00008.CrossRef Yerby SA, Toh E, McLain RF: Revision of failed pedicle screws using hydroxyapatite cement. A biomechanical analysis. Spine (Phila Pa 1976). 1998, 23 (15): 1657-1661. 10.1097/00007632-199808010-00008.CrossRef
20.
go back to reference Abshire BB, McLain RF, Valdevit A, Kambic HE: Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out. Spine J. 2001, 1 (6): 408-414. 10.1016/S1529-9430(01)00119-X.CrossRefPubMed Abshire BB, McLain RF, Valdevit A, Kambic HE: Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out. Spine J. 2001, 1 (6): 408-414. 10.1016/S1529-9430(01)00119-X.CrossRefPubMed
21.
go back to reference Renner SM, Lim TH, Kim WJ, Katolik L, An HS, Andersson GB: Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Spine (Phila Pa 1976). 2004, 29 (11): E212-216. 10.1097/00007632-200406010-00020.CrossRef Renner SM, Lim TH, Kim WJ, Katolik L, An HS, Andersson GB: Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Spine (Phila Pa 1976). 2004, 29 (11): E212-216. 10.1097/00007632-200406010-00020.CrossRef
22.
go back to reference Sarzier JS, Evans AJ, Cahill DW: Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines. J Neurosurg. 2002, 96 (3 Suppl): 309-312.PubMed Sarzier JS, Evans AJ, Cahill DW: Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines. J Neurosurg. 2002, 96 (3 Suppl): 309-312.PubMed
23.
go back to reference Moore DC, Maitra RS, Farjo LA, Graziano GP, Goldstein SA: Restoration of pedicle screw fixation with an in situ setting calcium phosphate cement. Spine (Phila Pa 1976). 1997, 22 (15): 1696-1705. 10.1097/00007632-199708010-00003.CrossRef Moore DC, Maitra RS, Farjo LA, Graziano GP, Goldstein SA: Restoration of pedicle screw fixation with an in situ setting calcium phosphate cement. Spine (Phila Pa 1976). 1997, 22 (15): 1696-1705. 10.1097/00007632-199708010-00003.CrossRef
24.
go back to reference Yilmaz C, Atalay B, Caner H, Altinors N: Augmentation of a loosened sacral pedicle screw with percutaneous polymethylmethacrylate injection. J Spinal Disord Tech. 2006, 19 (5): 373-375. 10.1097/01.bsd.0000210115.94273.76.CrossRefPubMed Yilmaz C, Atalay B, Caner H, Altinors N: Augmentation of a loosened sacral pedicle screw with percutaneous polymethylmethacrylate injection. J Spinal Disord Tech. 2006, 19 (5): 373-375. 10.1097/01.bsd.0000210115.94273.76.CrossRefPubMed
25.
go back to reference Linhardt O, Luring C, Matussek J, Hamberger C, Plitz W, Grifka J: Stability of pedicle screws after kyphoplasty augmentation: an experimental study to compare transpedicular screw fixation in soft and cured kyphoplasty cement. J Spinal Disord Tech. 2006, 19 (2): 87-91. 10.1097/01.bsd.0000177212.52583.bd.CrossRefPubMed Linhardt O, Luring C, Matussek J, Hamberger C, Plitz W, Grifka J: Stability of pedicle screws after kyphoplasty augmentation: an experimental study to compare transpedicular screw fixation in soft and cured kyphoplasty cement. J Spinal Disord Tech. 2006, 19 (2): 87-91. 10.1097/01.bsd.0000177212.52583.bd.CrossRefPubMed
26.
go back to reference Lotz JC, Hu SS, Chiu DF, Yu M, Colliou O, Poser RD: Carbonated apatite cement augmentation of pedicle screw fixation in the lumbar spine. Spine (Phila Pa 1976). 1997, 22 (23): 2716-2723. 10.1097/00007632-199712010-00003.CrossRef Lotz JC, Hu SS, Chiu DF, Yu M, Colliou O, Poser RD: Carbonated apatite cement augmentation of pedicle screw fixation in the lumbar spine. Spine (Phila Pa 1976). 1997, 22 (23): 2716-2723. 10.1097/00007632-199712010-00003.CrossRef
27.
go back to reference Chang MC, Liu CL, Chen TH: Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: a novel technique. Spine (Phila Pa 1976). 2008, 33 (10): E317-324. 10.1097/BRS.0b013e31816f6c73.CrossRef Chang MC, Liu CL, Chen TH: Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: a novel technique. Spine (Phila Pa 1976). 2008, 33 (10): E317-324. 10.1097/BRS.0b013e31816f6c73.CrossRef
28.
go back to reference Evans SL, Hunt CM, Ahuja S: Bone cement or bone substitute augmentation of pedicle screws improves pullout strength in posterior spinal fixation. J Mater Sci Mater Med. 2002, 13 (12): 1143-1145. 10.1023/A:1021133819646.CrossRefPubMed Evans SL, Hunt CM, Ahuja S: Bone cement or bone substitute augmentation of pedicle screws improves pullout strength in posterior spinal fixation. J Mater Sci Mater Med. 2002, 13 (12): 1143-1145. 10.1023/A:1021133819646.CrossRefPubMed
29.
go back to reference Yagi M, King AB, Boachie-Adjei O: Characterization of osteopenia/osteoporosisin adult scoliosis: does bone density affect surgical outcome?. Spine. 2011, 36 (20): 1652-1657. 10.1097/BRS.0b013e31820110b4.CrossRefPubMed Yagi M, King AB, Boachie-Adjei O: Characterization of osteopenia/osteoporosisin adult scoliosis: does bone density affect surgical outcome?. Spine. 2011, 36 (20): 1652-1657. 10.1097/BRS.0b013e31820110b4.CrossRefPubMed
30.
go back to reference Pappou IP, Girardi FP, Sandhu HS, Parvataneni HK, Cammisa FP, Schneider R, Frelinghuysen P, Lane JM: Discordantly high spinal bone mineral density values in patients with adult lumbar scoliosis. Spine. 2006, 31 (14): 1614-1620. 10.1097/01.brs.0000222030.32171.5f.CrossRefPubMed Pappou IP, Girardi FP, Sandhu HS, Parvataneni HK, Cammisa FP, Schneider R, Frelinghuysen P, Lane JM: Discordantly high spinal bone mineral density values in patients with adult lumbar scoliosis. Spine. 2006, 31 (14): 1614-1620. 10.1097/01.brs.0000222030.32171.5f.CrossRefPubMed
Metadata
Title
Comparison between two pedicle screw augmentation instrumentations in adult degenerative scoliosis with osteoporosis
Authors
Yang Xie
Qiang Fu
Zi-qiang Chen
Zhi-cai Shi
Xiao-dong Zhu
Chuan-feng Wang
Ming Li
Publication date
01-12-2011
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2011
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-12-286

Other articles of this Issue 1/2011

BMC Musculoskeletal Disorders 1/2011 Go to the issue