Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2011

Open Access 01-12-2011 | Study protocol

Minimally invasive computer-navigated total hip arthroplasty, following the concept of femur first and combined anteversion: design of a blinded randomized controlled trial

Authors: Tobias Renkawitz, Martin Haimerl, Lars Dohmen, Sabine Gneiting, Melanie Wegner, Nicole Ehret, Claudia Buchele, Mario Schubert, Philipp Lechler, Michael Woerner, Ernst Sendtner, Tibor Schuster, Kurt Ulm, Robert Springorum, Joachim Grifka

Published in: BMC Musculoskeletal Disorders | Issue 1/2011

Login to get access

Abstract

Background

Impingement can be a serious complication after total hip arthroplasty (THA), and is one of the major causes of postoperative pain, dislocation, aseptic loosening, and implant breakage. Minimally invasive THA and computer-navigated surgery were introduced several years ago. We have developed a novel, computer-assisted operation method for THA following the concept of "femur first"/"combined anteversion", which incorporates various aspects of performing a functional optimization of the cup position, and comprehensively addresses range of motion (ROM) as well as cup containment and alignment parameters. Hence, the purpose of this study is to assess whether the artificial joint's ROM can be improved by this computer-assisted operation method. Second, the clinical and radiological outcome will be evaluated.

Methods/Design

A registered patient- and observer-blinded randomized controlled trial will be conducted. Patients between the ages of 50 and 75 admitted for primary unilateral THA will be included. Patients will be randomly allocated to either receive minimally invasive computer-navigated "femur first" THA or the conventional minimally invasive THA procedure. Self-reported functional status and health-related quality of life (questionnaires) will be assessed both preoperatively and postoperatively. Perioperative complications will be registered. Radiographic evaluation will take place up to 6 weeks postoperatively with a computed tomography (CT) scan. Component position will be evaluated by an independent external institute on a 3D reconstruction of the femur/pelvis using image-processing software. Postoperative ROM will be calculated by an algorithm which automatically determines bony and prosthetic impingements.

Discussion

In the past, computer navigation has improved the accuracy of component positioning. So far, there are only few objective data quantifying the risks and benefits of computer navigated THA. Therefore, this study has been designed to compare minimally invasive computer-navigated "femur first" THA with a conventional technique for minimally invasive THA. The results of this trial will be presented as soon as they become available.

Trial registration number

DRKS00000739
Literature
1.
go back to reference Malik A, Maheshwari A, Dorr LD: Impingement with total hip replacement. J Bone Joint Surg Am. 2007, 89: 1832-1842. 10.2106/JBJS.F.01313.CrossRefPubMed Malik A, Maheshwari A, Dorr LD: Impingement with total hip replacement. J Bone Joint Surg Am. 2007, 89: 1832-1842. 10.2106/JBJS.F.01313.CrossRefPubMed
2.
go back to reference Widmer KH: Containment versus impingement: finding a compromise for cup placement in total hip arthroplasty. Int Orthop. 2007, 31 (Suppl 1): S29-33.CrossRefPubMed Widmer KH: Containment versus impingement: finding a compromise for cup placement in total hip arthroplasty. Int Orthop. 2007, 31 (Suppl 1): S29-33.CrossRefPubMed
3.
go back to reference Jolles BM, Zangger P, Leyvraz PF: Factors presdisposing to dislocation after primary total hip prosthesis. J Arthroplasty. 2002, 17: 282-288. 10.1054/arth.2002.30286.CrossRefPubMed Jolles BM, Zangger P, Leyvraz PF: Factors presdisposing to dislocation after primary total hip prosthesis. J Arthroplasty. 2002, 17: 282-288. 10.1054/arth.2002.30286.CrossRefPubMed
4.
go back to reference Nadzadi ME, Pedersen DR, Yack HJ, Callaghan JJ, Brown TD: Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation. J Biomech. 2003, 36: 577-591. 10.1016/S0021-9290(02)00232-4.CrossRefPubMed Nadzadi ME, Pedersen DR, Yack HJ, Callaghan JJ, Brown TD: Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation. J Biomech. 2003, 36: 577-591. 10.1016/S0021-9290(02)00232-4.CrossRefPubMed
5.
go back to reference Barrack RL: Dislocation after total hip arthroplasty: implant design and orientation. J Am Acad Orthop Surg. 2003, 11: 89-CrossRefPubMed Barrack RL: Dislocation after total hip arthroplasty: implant design and orientation. J Am Acad Orthop Surg. 2003, 11: 89-CrossRefPubMed
6.
go back to reference Del Schutte H, Lipman AJ, Bannar SM, Livermore JT, Ilstrup D, Morrey BF: Effects of acetabular abduction on cup wear rates in total hip arthroplasty. J Arthroplasty. 1998, 13: 621-626. 10.1016/S0883-5403(98)80003-X.CrossRefPubMed Del Schutte H, Lipman AJ, Bannar SM, Livermore JT, Ilstrup D, Morrey BF: Effects of acetabular abduction on cup wear rates in total hip arthroplasty. J Arthroplasty. 1998, 13: 621-626. 10.1016/S0883-5403(98)80003-X.CrossRefPubMed
7.
go back to reference Wines AP, McNicol D: Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty. 2006, 21: 696-701. 10.1016/j.arth.2005.11.008.CrossRefPubMed Wines AP, McNicol D: Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty. 2006, 21: 696-701. 10.1016/j.arth.2005.11.008.CrossRefPubMed
8.
go back to reference Sendtner E, Tibor S, Winkler R, Wörner M, Grifka J, Renkawitz T: Stem torsion in total hip replacement. Acta Orthop. 2010, 5: 579-582.CrossRef Sendtner E, Tibor S, Winkler R, Wörner M, Grifka J, Renkawitz T: Stem torsion in total hip replacement. Acta Orthop. 2010, 5: 579-582.CrossRef
9.
go back to reference Ranawat CS, Maynard MJ: Modern Techniques of Cemented Total Hip Arthroplasty. Tech Orthopedics. 1991, 6: 17-25. 10.1097/00013611-199109000-00004.CrossRef Ranawat CS, Maynard MJ: Modern Techniques of Cemented Total Hip Arthroplasty. Tech Orthopedics. 1991, 6: 17-25. 10.1097/00013611-199109000-00004.CrossRef
10.
go back to reference Dorr LD, Malik A, Dastane M, Wan Z: Combined anteversion technique for total hip arthroplasty. Clin Orthop Relat Res. 2009, 1: 119-127.CrossRef Dorr LD, Malik A, Dastane M, Wan Z: Combined anteversion technique for total hip arthroplasty. Clin Orthop Relat Res. 2009, 1: 119-127.CrossRef
11.
go back to reference Widmer KH, Zurfluh B: Compliant positioning of total hip components for optimal range of motion. J Orthop Res. 2004, 22: 815-821. 10.1016/j.orthres.2003.11.001.CrossRefPubMed Widmer KH, Zurfluh B: Compliant positioning of total hip components for optimal range of motion. J Orthop Res. 2004, 22: 815-821. 10.1016/j.orthres.2003.11.001.CrossRefPubMed
12.
go back to reference Renkawitz T, Schuster T, Herold T, Goessmann H, Sendtner E, Grifka J, Kalteis T: Measuring leg length and offset with an imageless navigation system during total hip arthroplasty: is it really accurate?. Int J Med Robot. 2009, 2: 192-197.CrossRef Renkawitz T, Schuster T, Herold T, Goessmann H, Sendtner E, Grifka J, Kalteis T: Measuring leg length and offset with an imageless navigation system during total hip arthroplasty: is it really accurate?. Int J Med Robot. 2009, 2: 192-197.CrossRef
13.
go back to reference Jolles BM, Genoud P, Hoffmeyer P: Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement. Clin Orthop Relat Res. 2004, 426: 174-179.CrossRefPubMed Jolles BM, Genoud P, Hoffmeyer P: Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement. Clin Orthop Relat Res. 2004, 426: 174-179.CrossRefPubMed
14.
go back to reference Paratte S, Argenson JN: Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. A prospective, randomized, controlled study. J Bone Joint Surg Am. 2007, 89: 494-499. 10.2106/JBJS.F.00529.CrossRef Paratte S, Argenson JN: Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. A prospective, randomized, controlled study. J Bone Joint Surg Am. 2007, 89: 494-499. 10.2106/JBJS.F.00529.CrossRef
15.
go back to reference Dorr LD, Malik A, Wan Z, Long WT, Harris M: Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position. Clin Orthop Relat Res. 2007, 465: 92-99.PubMed Dorr LD, Malik A, Wan Z, Long WT, Harris M: Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position. Clin Orthop Relat Res. 2007, 465: 92-99.PubMed
16.
go back to reference Renkawitz T, Tingart M, Grifka J, Sendtner E, Kalteis T: Computer-assisted total hip arthroplasty: coding the next generation of navigation systems for orthopedic surgery. Expert Rev Med Devices. 2009, 5: 507-514.CrossRef Renkawitz T, Tingart M, Grifka J, Sendtner E, Kalteis T: Computer-assisted total hip arthroplasty: coding the next generation of navigation systems for orthopedic surgery. Expert Rev Med Devices. 2009, 5: 507-514.CrossRef
17.
go back to reference Michel MC, Witschger P: MicroHip: a minimally invasive procedure for total hip replacement surgery using a modified Smith-Peterson approach. Ortop Traumatol Rehabil. 2007, 1: 46-51. Michel MC, Witschger P: MicroHip: a minimally invasive procedure for total hip replacement surgery using a modified Smith-Peterson approach. Ortop Traumatol Rehabil. 2007, 1: 46-51.
18.
go back to reference Murray DW: The definition and measurement of acetabular orientation. J Bone Joint Surg Br. 1993, 75: 228-232.PubMed Murray DW: The definition and measurement of acetabular orientation. J Bone Joint Surg Br. 1993, 75: 228-232.PubMed
19.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR: Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978, 60: 217-220.PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR: Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978, 60: 217-220.PubMed
20.
go back to reference Ethgen O, Vanparijs P, Delhalle S, Rosant S, Bruyere O, Reginster JY: Social support and health-related quality of life in hip and knee osteoarthritis. Qual Life Res. 2004, 13: 321-330.CrossRefPubMed Ethgen O, Vanparijs P, Delhalle S, Rosant S, Bruyere O, Reginster JY: Social support and health-related quality of life in hip and knee osteoarthritis. Qual Life Res. 2004, 13: 321-330.CrossRefPubMed
21.
go back to reference Lingard E, Hashimoto H, Sledge C: Development of outcome research for total joint arthroplasty. J Orthop Sci. 2000, 5: 175-177. 10.1007/s007760050146.CrossRefPubMed Lingard E, Hashimoto H, Sledge C: Development of outcome research for total joint arthroplasty. J Orthop Sci. 2000, 5: 175-177. 10.1007/s007760050146.CrossRefPubMed
23.
go back to reference Harris WH: Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969, 4: 737-755. Harris WH: Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969, 4: 737-755.
24.
go back to reference Mahomed N, Sledge C, Daltroy L, Fossel A, Katz J: Self-administered satisfaction scale for joint replacement arthroplasty. J Bone Joint Surg Br. 1998, 80 (Suppl 1): 9- Mahomed N, Sledge C, Daltroy L, Fossel A, Katz J: Self-administered satisfaction scale for joint replacement arthroplasty. J Bone Joint Surg Br. 1998, 80 (Suppl 1): 9-
25.
go back to reference Yoshimine F: The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements. J Biomech. 2006, 39: 1315-1323. 10.1016/j.jbiomech.2005.03.008.CrossRefPubMed Yoshimine F: The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements. J Biomech. 2006, 39: 1315-1323. 10.1016/j.jbiomech.2005.03.008.CrossRefPubMed
26.
go back to reference D'Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW: The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am. 2000, 3: 315-321. D'Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW: The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am. 2000, 3: 315-321.
27.
go back to reference Haimerl M, Gneiting S, Dohmen L, Herzog A, Kramer S, Woerner M, Sendtner E, Renkawitz T: Proximal femoral tilt and its effect on range-of-motion. Proceedings of the 10th Annual Meeting of Computer Assisted Orthopaedic Surgery: 17-19 June 2010; Paris. Edited by: Davies B, Joskowicz L, Merloz P. 2010, Berlin: Pro Business, 300-303. Haimerl M, Gneiting S, Dohmen L, Herzog A, Kramer S, Woerner M, Sendtner E, Renkawitz T: Proximal femoral tilt and its effect on range-of-motion. Proceedings of the 10th Annual Meeting of Computer Assisted Orthopaedic Surgery: 17-19 June 2010; Paris. Edited by: Davies B, Joskowicz L, Merloz P. 2010, Berlin: Pro Business, 300-303.
28.
go back to reference Parratte S, Pagnano MW, Coleman-Wood K, Kaufman KR, Berry DJ: Variation in Postoperative Pelvic Tilt May Confound the Accuracy of Hip Navigation Systems. Clin Orthop Relat Res. 2009, 467: 43-49. 10.1007/s11999-008-0521-z.CrossRefPubMed Parratte S, Pagnano MW, Coleman-Wood K, Kaufman KR, Berry DJ: Variation in Postoperative Pelvic Tilt May Confound the Accuracy of Hip Navigation Systems. Clin Orthop Relat Res. 2009, 467: 43-49. 10.1007/s11999-008-0521-z.CrossRefPubMed
29.
go back to reference Babisch JW, Layher F, Amiot LP: The rationale for tilt-adjusted acetabular cup navigation. J Bone Joint Surg Am. 2008, 2: 357-365.CrossRef Babisch JW, Layher F, Amiot LP: The rationale for tilt-adjusted acetabular cup navigation. J Bone Joint Surg Am. 2008, 2: 357-365.CrossRef
Metadata
Title
Minimally invasive computer-navigated total hip arthroplasty, following the concept of femur first and combined anteversion: design of a blinded randomized controlled trial
Authors
Tobias Renkawitz
Martin Haimerl
Lars Dohmen
Sabine Gneiting
Melanie Wegner
Nicole Ehret
Claudia Buchele
Mario Schubert
Philipp Lechler
Michael Woerner
Ernst Sendtner
Tibor Schuster
Kurt Ulm
Robert Springorum
Joachim Grifka
Publication date
01-12-2011
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2011
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-12-192

Other articles of this Issue 1/2011

BMC Musculoskeletal Disorders 1/2011 Go to the issue