Published in: BMC Musculoskeletal Disorders 1/2009

Open Access 01-12-2009 | Research article

Is visual estimation of passive range of motion in the pediatric lower limb valid and reliable

Authors: Rami Rachkidi, Ismat Ghanem, Ibrahim Kalouche, Samer El Hage, Fernand Dagher, Khalil Kharrat

Published in: BMC Musculoskeletal Disorders | Issue 1/2009

Login to get access

Abstract

Background

Visual estimation (VE) is an essential tool for evaluation of range of motion. Few papers discussed its validity in children orthopedics' practice. The purpose of our study was to assess validity and reliability of VE for passive range of motions (PROMs) of children's lower limbs.

Methods

Fifty typically developing children (100 lower limbs) were examined. Visual estimations for PROMs of hip (flexion, adduction, abduction, internal and external rotations), knee (flexion and popliteal angle) and ankle (dorsiflexion and plantarflexion) were made by a pediatric orthopaedic surgeon (POS) and a 5th year resident in orthopaedics. A last year medical student did goniometric measurements. Three weeks later, same measurements were performed to assess reliability of visual estimation for each examiner.

Results

Visual estimations of the POS were highly reliable for hip flexion, hip rotations and popliteal angle (ρc ≥ 0.8). Reliability was good for hip abduction, knee flexion, ankle dorsiflexion and plantarflexion (ρc ≥ 0.7) but poor for hip adduction (ρc = 0.5). Reproducibility for all PROMs was verified. Resident's VE showed high reliability (ρc ≥ 0.8) for hip flexion and popliteal angle. Good correlation was found for hip rotations and knee flexion (ρc ≥ 0.7). Poor results were obtained for ankle PROMs (ρc < 0.6) as well as hip adduction and abduction, the results of which not being reproducible. Influence of experience was clearly demonstrated for PROMs of hip rotations, adduction and abduction as well as ankle plantarflexion.

Conclusion

Accuracy of VE of passive hip flexion and knee PROMs is high regardless of the examiner's experience. Same accuracy can be found for hip rotations and abduction whenever VE is performed by an experienced examiner. Goniometric evaluation is recommended for passive hip adduction and for ankle PROMs.
Appendix
Available only for authorised users
Literature
1.
go back to reference Glanzman AM, Swenson AE, Kim H: Intrarater range of motion reliability in cerebral palsy: a comparison of assessment methods. Pediatr Phys Ther Winter. 2008, 20 (4): 369-72. 10.1097/PEP.0b013e31818b7994.CrossRef Glanzman AM, Swenson AE, Kim H: Intrarater range of motion reliability in cerebral palsy: a comparison of assessment methods. Pediatr Phys Ther Winter. 2008, 20 (4): 369-72. 10.1097/PEP.0b013e31818b7994.CrossRef
2.
go back to reference Allington NJ, Leroy N, Doneux C: Ankle joint range of motion measurements in spastic cerebral palsy children: intraobserver and interobserver reliability and reproducibility of goniometry and visual estimation. J Pediatr Orthop B. 2002, 11 (3): 236-9. 10.1097/00009957-200207000-00007.PubMed Allington NJ, Leroy N, Doneux C: Ankle joint range of motion measurements in spastic cerebral palsy children: intraobserver and interobserver reliability and reproducibility of goniometry and visual estimation. J Pediatr Orthop B. 2002, 11 (3): 236-9. 10.1097/00009957-200207000-00007.PubMed
3.
go back to reference McWhirk LB, Glanzman AM: Within-session inter-rater realiability of goniometric measures in patients withspastic cerebral palsy. Pediatr Phys Ther Winter. 2006, 18 (4): 262-5. 10.1097/01.pep.0000234960.88761.97.CrossRef McWhirk LB, Glanzman AM: Within-session inter-rater realiability of goniometric measures in patients withspastic cerebral palsy. Pediatr Phys Ther Winter. 2006, 18 (4): 262-5. 10.1097/01.pep.0000234960.88761.97.CrossRef
4.
go back to reference Ten Berge SR, Halbertsma JP, Maathuis PG, Verheij NP, Dijkstra PU, Maathuis KG: Reliability of popliteal angle measurement: a study in cerebral palsy patientsand healthy controls. J Pediatr Orthop. 2007, 27 (6): 648-52.CrossRefPubMed Ten Berge SR, Halbertsma JP, Maathuis PG, Verheij NP, Dijkstra PU, Maathuis KG: Reliability of popliteal angle measurement: a study in cerebral palsy patientsand healthy controls. J Pediatr Orthop. 2007, 27 (6): 648-52.CrossRefPubMed
5.
go back to reference Mutlu A, Livanelioglu A, Gunel MK: Reliability of goniometric measurements in children with spastic cerebral palsy. Med Sci Monit. 2007, 13 (7): CR323-9.PubMed Mutlu A, Livanelioglu A, Gunel MK: Reliability of goniometric measurements in children with spastic cerebral palsy. Med Sci Monit. 2007, 13 (7): CR323-9.PubMed
6.
go back to reference Menadue C, Raymond J, Kilbreath SL, Refshauge KM, Adams R: Reliability of two goniometric methods of measuring active inversion and eversion range of motion at the ankle. BMC Musculoskelet Disord. 2006, 28 (7): 60-10.1186/1471-2474-7-60.CrossRef Menadue C, Raymond J, Kilbreath SL, Refshauge KM, Adams R: Reliability of two goniometric methods of measuring active inversion and eversion range of motion at the ankle. BMC Musculoskelet Disord. 2006, 28 (7): 60-10.1186/1471-2474-7-60.CrossRef
7.
go back to reference Youdas JW, Bogard CL, Suman VJ: Reliability of goniometric measurements and visual estimates of ankle joint active range of motion obtained in a clinical setting. Arch Phys Med Rehabil. 1993, 74 (10): 1113-8. 10.1016/0003-9993(93)90071-H.CrossRefPubMed Youdas JW, Bogard CL, Suman VJ: Reliability of goniometric measurements and visual estimates of ankle joint active range of motion obtained in a clinical setting. Arch Phys Med Rehabil. 1993, 74 (10): 1113-8. 10.1016/0003-9993(93)90071-H.CrossRefPubMed
8.
go back to reference Brosseau I, Balmer S, Tousignant M, O'Sullivan JP, Goudreault C, Goudreault M, Gringras S: Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions. Arch Phys Med Rehabil. 2001, 82 (3): 396-402. 10.1053/apmr.2001.19250.CrossRefPubMed Brosseau I, Balmer S, Tousignant M, O'Sullivan JP, Goudreault C, Goudreault M, Gringras S: Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions. Arch Phys Med Rehabil. 2001, 82 (3): 396-402. 10.1053/apmr.2001.19250.CrossRefPubMed
9.
go back to reference Brosseau I, Tousignant M, Budd J, Chartier N, Duciaume L, Plamondon S, O'Sullivan JP, O'Donoghue S, Balmer S: Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects. Physiother Res Int. 1997, 2 (3): 150-66. 10.1002/pri.97.CrossRefPubMed Brosseau I, Tousignant M, Budd J, Chartier N, Duciaume L, Plamondon S, O'Sullivan JP, O'Donoghue S, Balmer S: Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects. Physiother Res Int. 1997, 2 (3): 150-66. 10.1002/pri.97.CrossRefPubMed
10.
go back to reference Watkins MA, Riddle DL, Lamb RL, Personius WJ: Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting. Phys Ther. 1991, 71 (2): 90-6.PubMed Watkins MA, Riddle DL, Lamb RL, Personius WJ: Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting. Phys Ther. 1991, 71 (2): 90-6.PubMed
11.
go back to reference Ashton BB, Pickles B, Roll JW: Reliability of goniometric measurements of hip motion in spastic cerebral palsy. Dev Med Child Neurol. 1978, 20: 87-94.CrossRefPubMed Ashton BB, Pickles B, Roll JW: Reliability of goniometric measurements of hip motion in spastic cerebral palsy. Dev Med Child Neurol. 1978, 20: 87-94.CrossRefPubMed
12.
go back to reference Harris SR, Smith LH, Krukowski L: Goniometric reliability for a child with spastic quadriplegia. J Pediatr Orthop. 1985, 5: 348-351.CrossRefPubMed Harris SR, Smith LH, Krukowski L: Goniometric reliability for a child with spastic quadriplegia. J Pediatr Orthop. 1985, 5: 348-351.CrossRefPubMed
13.
go back to reference Stuberg WA, Fuchs RH, Miedaner JA: Reliability of goniometric measurements of children with cerebral palsy. Dev Med Child Neurol. 1988, 30: 657-666.CrossRefPubMed Stuberg WA, Fuchs RH, Miedaner JA: Reliability of goniometric measurements of children with cerebral palsy. Dev Med Child Neurol. 1988, 30: 657-666.CrossRefPubMed
14.
go back to reference McDowell BC, Hewitt V, Nurse A, Weston T, Baker R: The variability of goniometric measurements in ambulatory children with spastic cerebral palsy. Gait Posture. 2000, 12: 114-121. 10.1016/S0966-6362(00)00068-0.CrossRefPubMed McDowell BC, Hewitt V, Nurse A, Weston T, Baker R: The variability of goniometric measurements in ambulatory children with spastic cerebral palsy. Gait Posture. 2000, 12: 114-121. 10.1016/S0966-6362(00)00068-0.CrossRefPubMed
15.
go back to reference Kilgour G, McNair P, Stott NS: Intrarater reliability of lower limb sagittal range-of-motion measures in children with spastic diplegia. Dev Med Child Neurol. 2003, 45: 391-399. 10.1017/S0012162203000744.CrossRefPubMed Kilgour G, McNair P, Stott NS: Intrarater reliability of lower limb sagittal range-of-motion measures in children with spastic diplegia. Dev Med Child Neurol. 2003, 45: 391-399. 10.1017/S0012162203000744.CrossRefPubMed
16.
go back to reference Gajdosik RI, Bohannon RW: Clinical Measurement of Range of Motion. Review of Goniometry Emphasizing Reliability and Validity. Phys Ther. 1987, 67 (12): 1867-72.PubMed Gajdosik RI, Bohannon RW: Clinical Measurement of Range of Motion. Review of Goniometry Emphasizing Reliability and Validity. Phys Ther. 1987, 67 (12): 1867-72.PubMed
17.
go back to reference Ghanem I, Seringe R: Comparison of evaluation methods of the results of congenital clubfoot treatment. Rev Chir Orthop Reparatrice Appar Mot. 1995, 81 (7): 615-21.PubMed Ghanem I, Seringe R: Comparison of evaluation methods of the results of congenital clubfoot treatment. Rev Chir Orthop Reparatrice Appar Mot. 1995, 81 (7): 615-21.PubMed
18.
go back to reference Fish DR, Wingate L: Sources of goniometric error at the elbow. Phys Ther. 1985, 65 (11): 1666-70.PubMed Fish DR, Wingate L: Sources of goniometric error at the elbow. Phys Ther. 1985, 65 (11): 1666-70.PubMed
19.
go back to reference Palmer ML, Epler MF: Fundamentals of musculoskeletal assessment techniques. 1998, Philadelphia: Lippincott Williams & Wilkins, 2 Palmer ML, Epler MF: Fundamentals of musculoskeletal assessment techniques. 1998, Philadelphia: Lippincott Williams & Wilkins, 2
20.
go back to reference Clarkson HM: Musculoskeletal assessment: joint range of motion and manual muscle strength. 2000, Baltimore: Lippincott Williams & Wilkins, 2 Clarkson HM: Musculoskeletal assessment: joint range of motion and manual muscle strength. 2000, Baltimore: Lippincott Williams & Wilkins, 2
21.
go back to reference Lin LI: A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989, 45 (1): 255-68. 10.2307/2532051.CrossRefPubMed Lin LI: A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989, 45 (1): 255-68. 10.2307/2532051.CrossRefPubMed
22.
go back to reference Barnhart HX, Haber M, Song J: Overall concordance correlation coefficient for evaluating agreement among multiple observers. Biometrics. 2002, 58 (4): 1020-7. 10.1111/j.0006-341X.2002.01020.x.CrossRefPubMed Barnhart HX, Haber M, Song J: Overall concordance correlation coefficient for evaluating agreement among multiple observers. Biometrics. 2002, 58 (4): 1020-7. 10.1111/j.0006-341X.2002.01020.x.CrossRefPubMed
23.
go back to reference Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986, 1 (8476): 908-9. 10.1016/S0140-6736(86)91008-1.CrossRefPubMed Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986, 1 (8476): 908-9. 10.1016/S0140-6736(86)91008-1.CrossRefPubMed
24.
go back to reference Bland JM, Altman DG: Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet. 1995, 346: 1085-87. 10.1016/S0140-6736(95)91748-9.CrossRefPubMed Bland JM, Altman DG: Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet. 1995, 346: 1085-87. 10.1016/S0140-6736(95)91748-9.CrossRefPubMed
25.
go back to reference Lin LI: Assay validation using the concordance correlation coefficient. Biometrics. 1992, 48: 599-604. 10.2307/2532314.CrossRef Lin LI: Assay validation using the concordance correlation coefficient. Biometrics. 1992, 48: 599-604. 10.2307/2532314.CrossRef
26.
go back to reference Marks JS, Palmer MK, Burke MJ, Smith P: Observer variation in the examination of knee joints. Ann Rheum Dis. 1978, 37 (4): 376-7. 10.1136/ard.37.4.376.CrossRefPubMedPubMedCentral Marks JS, Palmer MK, Burke MJ, Smith P: Observer variation in the examination of knee joints. Ann Rheum Dis. 1978, 37 (4): 376-7. 10.1136/ard.37.4.376.CrossRefPubMedPubMedCentral
27.
go back to reference Rowe CR: Joint measurement in disability evaluation. Clin Orthop Relat Res. 1964, 32: 43-53.PubMed Rowe CR: Joint measurement in disability evaluation. Clin Orthop Relat Res. 1964, 32: 43-53.PubMed
28.
go back to reference Amis AA, Miller JH: The elbow. Clin Rheum Dis. 1982, 8 (3): 571-93.PubMed Amis AA, Miller JH: The elbow. Clin Rheum Dis. 1982, 8 (3): 571-93.PubMed
29.
go back to reference Wagner C: Determination of the rotary flexibility of the elbow joint. Eur J Appl Physiol Occup Physiol. 1977, 37 (1): 47-59. 10.1007/BF00421598.CrossRefPubMed Wagner C: Determination of the rotary flexibility of the elbow joint. Eur J Appl Physiol Occup Physiol. 1977, 37 (1): 47-59. 10.1007/BF00421598.CrossRefPubMed
30.
go back to reference Bohannon RW, Lieber C: Cybex® II isokinetic dynamometer for passive load application and measurement: Suggestion from the field. Phys Ther. 1986, 66: 1407-PubMed Bohannon RW, Lieber C: Cybex® II isokinetic dynamometer for passive load application and measurement: Suggestion from the field. Phys Ther. 1986, 66: 1407-PubMed
31.
go back to reference Boone DC, Azen SP, Lin CM, Spence C, Baron C, Lee L: Reliability of goniometric measurements. Phys Ther. 1978, 58 (11): 1355-90.PubMed Boone DC, Azen SP, Lin CM, Spence C, Baron C, Lee L: Reliability of goniometric measurements. Phys Ther. 1978, 58 (11): 1355-90.PubMed
32.
go back to reference Joint motion: A Method of Measuring and Recording. 1965, Chicago, III: American Academy of Orthopaedic Surgeons, 8- Joint motion: A Method of Measuring and Recording. 1965, Chicago, III: American Academy of Orthopaedic Surgeons, 8-
Metadata
Title
Is visual estimation of passive range of motion in the pediatric lower limb valid and reliable
Authors
Rami Rachkidi
Ismat Ghanem
Ibrahim Kalouche
Samer El Hage
Fernand Dagher
Khalil Kharrat
Publication date
01-12-2009
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2009
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-10-126

Other articles of this Issue 1/2009

BMC Musculoskeletal Disorders 1/2009 Go to the issue