Skip to main content
Top
Published in: BMC Medical Imaging 1/2014

Open Access 01-12-2014 | Research article

Intelligent neonatal monitoring based on a virtual thermal sensor

Authors: Abbas K Abbas, Steffen Leonhardt

Published in: BMC Medical Imaging | Issue 1/2014

Login to get access

Abstract

Background

Temperature measurement is a vital part of daily neonatal care. Accurate measurements are important for detecting deviations from normal values for both optimal incubator and radiant warmer functioning. The purpose of monitoring the temperature is to maintain the infant in a thermoneutral environmental zone. This physiological zone is defined as the narrow range of environmental temperatures in which the infant maintains a normal body temperature without increasing his or her metabolic rate and thus oxygen consumption. Although the temperature measurement gold standard is the skin electrode, infrared thermography (IRT) should be considered as an effortless and reliable tool for measuring and mapping human skin temperature distribution and assist in assessing thermoregulatory reflexes.

Methods

Body surface temperature was recorded under several clinical conditions using an infrared thermography imaging technique. Temperature distributions were recorded as real-time video, which was analyzed to evaluate mean skin temperatures. Emissivity variations were considered for optimal neonatal IRT correction for which the compensation vector was overlaid on the tracking algorithm to improve the temperature reading. Finally, a tracking algorithm was designed for active follow-up of the defined region of interest over a neonate’s geometry.

Results

The outcomes obtained from the thermal virtual sensor demonstrate its ability to accurately track different geometric profiles and shapes over the external anatomy of a neonate. Only a small percentage of the motion detection attempts failed to fit tracking scenarios due to the lack of a properly matching matrix for the ROI profile over neonate’s body surface.

Conclusions

This paper presents the design and implementation of a virtual temperature sensing application that can assist neonatologists in interpreting a neonate’s skin temperature patterns. Regarding the surface temperature, the influence of different environmental conditions inside the incubator has been confirming.
Appendix
Available only for authorised users
Literature
2.
go back to reference Christidis I, Zotter H, Rosegger H, Engele H, Kurz R, Kerbl R: Infrared thermography in newborns: the first hour after birth. Gynakol Geburtshilfliche Rundsch. 2003, 43: 31-35.CrossRefPubMed Christidis I, Zotter H, Rosegger H, Engele H, Kurz R, Kerbl R: Infrared thermography in newborns: the first hour after birth. Gynakol Geburtshilfliche Rundsch. 2003, 43: 31-35.CrossRefPubMed
3.
go back to reference Adams AK, Nelson RA, Bell EF, Egoavil CA: Use of infrared thermographic calorimetry to determine energy expenditure in preterm infants. Am J Clin Nutr. 2000, 71: 969-977.PubMed Adams AK, Nelson RA, Bell EF, Egoavil CA: Use of infrared thermographic calorimetry to determine energy expenditure in preterm infants. Am J Clin Nutr. 2000, 71: 969-977.PubMed
4.
go back to reference Fei J, Pavlidis I: Thermistor at a distance: unobtrusive measurement of breathing. IEEE Trans Biomed Eng. 2010, 57: 988-998.CrossRefPubMed Fei J, Pavlidis I: Thermistor at a distance: unobtrusive measurement of breathing. IEEE Trans Biomed Eng. 2010, 57: 988-998.CrossRefPubMed
5.
go back to reference Fei J, Pavlidis I: Virtual thermistor. Conf Proc IEEE Eng Med Biol Soc. 2007, 2007: 250-253.PubMed Fei J, Pavlidis I: Virtual thermistor. Conf Proc IEEE Eng Med Biol Soc. 2007, 2007: 250-253.PubMed
6.
go back to reference Shastri D, Tsiamyrtzis P, Pavlidis I: Periorbital thermal signal extraction and applications. Conf Proc IEEE Eng Med Biol Soc. 2008, 2008: 102-105.PubMed Shastri D, Tsiamyrtzis P, Pavlidis I: Periorbital thermal signal extraction and applications. Conf Proc IEEE Eng Med Biol Soc. 2008, 2008: 102-105.PubMed
7.
go back to reference Abbas AK, Heiman K, Jergus K, Orlikowsky T, Leonhardt S, Abbas AK, Heiman K, Jergus K, Orlikowsky T, Leonhardt S: Non-contact respiratory monitoring based on real-time IR-thermography. World Congress on Medical Physics and Biomedical Engineering, September 7-12, 2009; Munich, Germany. Edited by: Dossel O, Schlegel WC. 2010, Berlin-Heidelberg: Springer, 1306-1309. Abbas AK, Heiman K, Jergus K, Orlikowsky T, Leonhardt S, Abbas AK, Heiman K, Jergus K, Orlikowsky T, Leonhardt S: Non-contact respiratory monitoring based on real-time IR-thermography. World Congress on Medical Physics and Biomedical Engineering, September 7-12, 2009; Munich, Germany. Edited by: Dossel O, Schlegel WC. 2010, Berlin-Heidelberg: Springer, 1306-1309.
8.
go back to reference Jones BF: A reappraisal of the use of infrared thermal image analysis in medicine. IEEE Trans Med Imaging. 1998, 17: 1019-1027.CrossRefPubMed Jones BF: A reappraisal of the use of infrared thermal image analysis in medicine. IEEE Trans Med Imaging. 1998, 17: 1019-1027.CrossRefPubMed
9.
go back to reference Garbey M, Sun N, Merla A, Pavlidis I: Contact-free measurement of cardiac pulse based on the analysis of thermal imagery. IEEE Trans Biomed Eng. 2007, 54: 1418-1426.CrossRefPubMed Garbey M, Sun N, Merla A, Pavlidis I: Contact-free measurement of cardiac pulse based on the analysis of thermal imagery. IEEE Trans Biomed Eng. 2007, 54: 1418-1426.CrossRefPubMed
10.
go back to reference Fei J, Pavlidis I: Analysis of breathing air flow patterns in thermal imaging. Conf Proc IEEE Eng Med Biol Soc. 2006, 1: 946-952.PubMed Fei J, Pavlidis I: Analysis of breathing air flow patterns in thermal imaging. Conf Proc IEEE Eng Med Biol Soc. 2006, 1: 946-952.PubMed
11.
go back to reference Sun N, Pavlidis I, Garbey M, Fei J: Harvesting the thermal cardiac pulse signal. Med Image Comput Comput Assist Interv. 2006, 9: 569-576.PubMed Sun N, Pavlidis I, Garbey M, Fei J: Harvesting the thermal cardiac pulse signal. Med Image Comput Comput Assist Interv. 2006, 9: 569-576.PubMed
12.
go back to reference Bhatia M, Poley JR, Haberman JD, Boon DJ: Abdominal thermography in infantile and childhood liver disease. South Med J. 1976, 69: 1045-1048.CrossRefPubMed Bhatia M, Poley JR, Haberman JD, Boon DJ: Abdominal thermography in infantile and childhood liver disease. South Med J. 1976, 69: 1045-1048.CrossRefPubMed
13.
go back to reference Murthy J, van Jaarsveld J, Fei J, Pavlidis I, Karrykissoon RI, Lucke JF, Faiz S, Castriolatta RJ: Thermal infrared imaging: a novel method to monitor airflow during polysomnography. Sleep. 2009, 32: 1521-1527.PubMedPubMedCentral Murthy J, van Jaarsveld J, Fei J, Pavlidis I, Karrykissoon RI, Lucke JF, Faiz S, Castriolatta RJ: Thermal infrared imaging: a novel method to monitor airflow during polysomnography. Sleep. 2009, 32: 1521-1527.PubMedPubMedCentral
14.
go back to reference Fei J, Pavlidis I, Murthy J: Thermal vision for sleep apnea monitoring. Med Image Comput Comput Assist Interv. 2009, 12: 1084-1091.PubMed Fei J, Pavlidis I, Murthy J: Thermal vision for sleep apnea monitoring. Med Image Comput Comput Assist Interv. 2009, 12: 1084-1091.PubMed
15.
go back to reference Ng EY, Chen Y, Ung LN: Computerized breast thermography: study of image segmentation and temperature cyclic variations. J Med Eng Technol. 2001, 25: 12-16.CrossRefPubMed Ng EY, Chen Y, Ung LN: Computerized breast thermography: study of image segmentation and temperature cyclic variations. J Med Eng Technol. 2001, 25: 12-16.CrossRefPubMed
16.
go back to reference Buddharaju P, Pavlidis IT, Tsiamyrtzis P, Bazakos M: Physiology-based face recognition in the thermal infrared spectrum. IEEE Trans Pattern Anal Mach Intell. 2007, 29: 613-626.CrossRefPubMed Buddharaju P, Pavlidis IT, Tsiamyrtzis P, Bazakos M: Physiology-based face recognition in the thermal infrared spectrum. IEEE Trans Pattern Anal Mach Intell. 2007, 29: 613-626.CrossRefPubMed
17.
go back to reference Abbas AK, Leonhardt S: NIRT pattern classification based on ICA clustering algorithm. 2008, Aachen Germany, FWS: Farbbildverarbeitung Workshop Abbas AK, Leonhardt S: NIRT pattern classification based on ICA clustering algorithm. 2008, Aachen Germany, FWS: Farbbildverarbeitung Workshop
18.
go back to reference Saxena AK, Willital GH: Infrared thermography: experience from a decade of pediatric imaging. Eur J Pediatr. 2008, 167: 757-764.CrossRefPubMed Saxena AK, Willital GH: Infrared thermography: experience from a decade of pediatric imaging. Eur J Pediatr. 2008, 167: 757-764.CrossRefPubMed
20.
go back to reference Abbas AK, Heiman K, Jergus K, Orlikowsky T, Leonhardt S: Neonatal monitoring technologies: Design for integrated solutions. Neonatal Infrared Thermography Imaging. Volume 1. Edited by: Oetomo SB, Chen W, Feijs L. 2012, Hershey, Pennsylvania: IGI Global Publishing, 84-124. Abbas AK, Heiman K, Jergus K, Orlikowsky T, Leonhardt S: Neonatal monitoring technologies: Design for integrated solutions. Neonatal Infrared Thermography Imaging. Volume 1. Edited by: Oetomo SB, Chen W, Feijs L. 2012, Hershey, Pennsylvania: IGI Global Publishing, 84-124.
21.
go back to reference Pavlidis I, Levine J: Thermal image analysis for polygraph testing. IEEE Eng Med Biol Mag. 2002, 21: 56-64.CrossRefPubMed Pavlidis I, Levine J: Thermal image analysis for polygraph testing. IEEE Eng Med Biol Mag. 2002, 21: 56-64.CrossRefPubMed
22.
go back to reference Mital M, Scott EP: Thermal detection of embedded tumors using infrared imaging. J Biomech Eng. 2007, 129: 33-39.CrossRefPubMed Mital M, Scott EP: Thermal detection of embedded tumors using infrared imaging. J Biomech Eng. 2007, 129: 33-39.CrossRefPubMed
23.
go back to reference Moskowitz M: Efficacy of computerized infrared imaging. Am J Roentgenol. 2003, 181: 596-CrossRef Moskowitz M: Efficacy of computerized infrared imaging. Am J Roentgenol. 2003, 181: 596-CrossRef
24.
go back to reference Rousselet GA, Mace MJ, Thorpe SJ, Fabre-Thorpe M: Limits of event-related potential differences in tracking object processing speed. J Cogn Neurosci. 2007, 19: 1241-1258.CrossRefPubMed Rousselet GA, Mace MJ, Thorpe SJ, Fabre-Thorpe M: Limits of event-related potential differences in tracking object processing speed. J Cogn Neurosci. 2007, 19: 1241-1258.CrossRefPubMed
25.
go back to reference Lalonde M, Beaulieu M, Gagnon L: Fast and robust optic disc detection using pyramidal decomposition and Hausdorff-based template matching. IEEE Trans Med Imaging. 2001, 20: 1193-1200.CrossRefPubMed Lalonde M, Beaulieu M, Gagnon L: Fast and robust optic disc detection using pyramidal decomposition and Hausdorff-based template matching. IEEE Trans Med Imaging. 2001, 20: 1193-1200.CrossRefPubMed
26.
go back to reference Marks TK, Hershey JR, Movellan JR: Tracking motion, deformation, and texture using conditionally gaussian processes. IEEE Trans Pattern Anal Mach Intell. 2010, 32: 348-363.CrossRefPubMed Marks TK, Hershey JR, Movellan JR: Tracking motion, deformation, and texture using conditionally gaussian processes. IEEE Trans Pattern Anal Mach Intell. 2010, 32: 348-363.CrossRefPubMed
27.
go back to reference Zhou Y, Tsiamyrtzis P, Pavlidis IT: Tissue tracking in thermo-physiological imagery through spatio-temporal smoothing. Med Image Comput Comput Assist Interv. 2009, 12: 1092-1099.PubMed Zhou Y, Tsiamyrtzis P, Pavlidis IT: Tissue tracking in thermo-physiological imagery through spatio-temporal smoothing. Med Image Comput Comput Assist Interv. 2009, 12: 1092-1099.PubMed
28.
go back to reference Zulkifley MA, Rawlinson D, Moran B: Robust observation detection for single object tracking: deterministic and probabilistic patch-based approaches. Sensors (Basel). 2012, 12: 15638-15670.CrossRef Zulkifley MA, Rawlinson D, Moran B: Robust observation detection for single object tracking: deterministic and probabilistic patch-based approaches. Sensors (Basel). 2012, 12: 15638-15670.CrossRef
29.
go back to reference Sheng Y-M, Xiu R-J: Automated method for tracking vasomotion of intravital microvascular and microlymphatic vessels. Clin Hemorheol Microcirc. 2012, 52: 37-48.PubMed Sheng Y-M, Xiu R-J: Automated method for tracking vasomotion of intravital microvascular and microlymphatic vessels. Clin Hemorheol Microcirc. 2012, 52: 37-48.PubMed
30.
go back to reference Lin Y-H, Chen C-H: Template matching using the parametric template vector with translation, rotation and scale invariance. Pattern Recogn. 2008, 41 (7): 2413-2421. DOI = 10.1016/j.patcog.2008.01.017CrossRef Lin Y-H, Chen C-H: Template matching using the parametric template vector with translation, rotation and scale invariance. Pattern Recogn. 2008, 41 (7): 2413-2421. DOI = 10.1016/j.patcog.2008.01.017CrossRef
31.
go back to reference Kasturi R, Goldgof D, Soundararajan P, Manohar V, Garofolo J, Bowers R, Boonstra M, Korzhova V, Zhang J: Framework for performance evaluation of face, text, and vehicle detection and tracking in video: data, metrics, and protocol. IEEE Trans Pattern Anal Mach Intell. 2009, 31: 319-336.CrossRefPubMed Kasturi R, Goldgof D, Soundararajan P, Manohar V, Garofolo J, Bowers R, Boonstra M, Korzhova V, Zhang J: Framework for performance evaluation of face, text, and vehicle detection and tracking in video: data, metrics, and protocol. IEEE Trans Pattern Anal Mach Intell. 2009, 31: 319-336.CrossRefPubMed
32.
go back to reference Lu C, Zhou G: Template match using local feature with view invariance. Proc. SPIE 8919, MIPPR. 2013, Pattern Recognition and Computer Vision, 89190C (October 27, 2013); doi:10.1117/12.2031068 Lu C, Zhou G: Template match using local feature with view invariance. Proc. SPIE 8919, MIPPR. 2013, Pattern Recognition and Computer Vision, 89190C (October 27, 2013); doi:10.1117/12.2031068
33.
go back to reference Höwing F, Dooley LS, Wermser D: Tracking of non-rigid articulatory organs in X-ray image sequences. Comput Med Imaging Graph. 1999, 23: 59-67.CrossRefPubMed Höwing F, Dooley LS, Wermser D: Tracking of non-rigid articulatory organs in X-ray image sequences. Comput Med Imaging Graph. 1999, 23: 59-67.CrossRefPubMed
34.
go back to reference Sun N, Pavlidis I: Counting heartbeats at a distance. Conf Proc IEEE Eng Med Biol Soc. 2006, 1: 228-231.PubMed Sun N, Pavlidis I: Counting heartbeats at a distance. Conf Proc IEEE Eng Med Biol Soc. 2006, 1: 228-231.PubMed
35.
go back to reference Krüger V, Sommer G: Wavelet networks for face processing. J Opt Soc Am A Opt Image Sci Vis. 2002, 19: 1112-1119.CrossRefPubMed Krüger V, Sommer G: Wavelet networks for face processing. J Opt Soc Am A Opt Image Sci Vis. 2002, 19: 1112-1119.CrossRefPubMed
36.
go back to reference Ng EY, Fok SC, Peh YC, Ng FC, Sim LS: Computerized detection of breast cancer with artificial intelligence and thermograms. J Med Eng Technol. 2002, 26: 152-157.CrossRefPubMed Ng EY, Fok SC, Peh YC, Ng FC, Sim LS: Computerized detection of breast cancer with artificial intelligence and thermograms. J Med Eng Technol. 2002, 26: 152-157.CrossRefPubMed
37.
go back to reference Zhu Z, Tsiamyrtzis P, Pavlidis I: Forehead thermal signature extraction in lie detection. Conf Proc IEEE Eng Med Biol Soc. 2007, 2007: 243-246.PubMed Zhu Z, Tsiamyrtzis P, Pavlidis I: Forehead thermal signature extraction in lie detection. Conf Proc IEEE Eng Med Biol Soc. 2007, 2007: 243-246.PubMed
38.
go back to reference Shastri D, Merla A, Tsiamyrtzis P, Pavlidis I: Imaging facial signs of neurophysiological responses. IEEE Trans Biomed Eng. 2009, 56: 477-484.CrossRefPubMed Shastri D, Merla A, Tsiamyrtzis P, Pavlidis I: Imaging facial signs of neurophysiological responses. IEEE Trans Biomed Eng. 2009, 56: 477-484.CrossRefPubMed
39.
go back to reference Pernkopf F: Tracking of multiple targets using online learning for reference model adaptation. IEEE Trans Syst Man Cybern B Cybern. 2008, 38: 1465-1475.CrossRefPubMed Pernkopf F: Tracking of multiple targets using online learning for reference model adaptation. IEEE Trans Syst Man Cybern B Cybern. 2008, 38: 1465-1475.CrossRefPubMed
40.
go back to reference Weiss ME, Poeltler D, Gocka I: Infrared tympanic thermometry for neonatal temperature assessment. J Obstet Gynecol Neonatal Nurs. 1994, 23: 798-804.CrossRefPubMed Weiss ME, Poeltler D, Gocka I: Infrared tympanic thermometry for neonatal temperature assessment. J Obstet Gynecol Neonatal Nurs. 1994, 23: 798-804.CrossRefPubMed
41.
go back to reference Pimentel JA, Corkidi G: Three dimensional template matching segmentation method for motile cells in 3D + t video sequences. Conf Proc IEEE Eng Med Biol Soc. 2010, 2010: 4777-4780.PubMed Pimentel JA, Corkidi G: Three dimensional template matching segmentation method for motile cells in 3D + t video sequences. Conf Proc IEEE Eng Med Biol Soc. 2010, 2010: 4777-4780.PubMed
42.
go back to reference Lin W-Y, Lin SF, Yang SC, Liou SC, Nath R, Liu W: Real-time automatic fiducial marker tracking in low contrast cine-MV images. Med Phys. 2013, 40: 011715-CrossRefPubMed Lin W-Y, Lin SF, Yang SC, Liou SC, Nath R, Liu W: Real-time automatic fiducial marker tracking in low contrast cine-MV images. Med Phys. 2013, 40: 011715-CrossRefPubMed
43.
go back to reference Abbas AK, Heimann K, Jergus K, Orlikowsky T, Leonhardt S: Neonatal non-contact respiratory monitoring based on real-time infrared thermography. Biomed Eng Online. 2011, 10: 93-CrossRefPubMedPubMedCentral Abbas AK, Heimann K, Jergus K, Orlikowsky T, Leonhardt S: Neonatal non-contact respiratory monitoring based on real-time infrared thermography. Biomed Eng Online. 2011, 10: 93-CrossRefPubMedPubMedCentral
44.
go back to reference Wang H, Oliensis J: Rigid shape matching by segmentation averaging. IEEE Trans Pattern Anal Mach Intell. 2010, 32: 619-635.CrossRefPubMed Wang H, Oliensis J: Rigid shape matching by segmentation averaging. IEEE Trans Pattern Anal Mach Intell. 2010, 32: 619-635.CrossRefPubMed
45.
go back to reference Banitalebi H, Bangstad H-J: Measurement of fever in children–is infrared tympanic thermometry reliable?. Tidsskr Nor Laegeforen. 2002, 122: 2700-2701.PubMed Banitalebi H, Bangstad H-J: Measurement of fever in children–is infrared tympanic thermometry reliable?. Tidsskr Nor Laegeforen. 2002, 122: 2700-2701.PubMed
46.
Metadata
Title
Intelligent neonatal monitoring based on a virtual thermal sensor
Authors
Abbas K Abbas
Steffen Leonhardt
Publication date
01-12-2014
Publisher
BioMed Central
Published in
BMC Medical Imaging / Issue 1/2014
Electronic ISSN: 1471-2342
DOI
https://doi.org/10.1186/1471-2342-14-9

Other articles of this Issue 1/2014

BMC Medical Imaging 1/2014 Go to the issue