Background

The validity of a meta-analysis can be understood better in light of the possible impact of publication bias. The majority of the methods to investigate publication bias in terms of small study-effects are developed for meta-analyses of intervention studies, leaving authors of diagnostic test accuracy (DTA) systematic reviews with limited guidance. The aim of this study was to evaluate if and how publication bias was assessed in meta-analyses of DTA, and to compare the results of various statistical methods used to assess publication bias.

Methods

A systematic search was initiated to identify DTA reviews with a meta-analysis published between September 2011 and January 2012. We extracted all information about publication bias from the reviews and the two-by-two tables. Existing statistical methods for the detection of publication bias were applied on data from the included studies.

Results

Out of 1,335 references, 114 reviews could be included. Publication bias was explicitly mentioned in 75 reviews (65.8%) and 47 of these had performed statistical methods to investigate publication bias in terms of small study-effects: 6 by drawing funnel plots, 16 by statistical testing and 25 by applying both methods. The applied tests were Egger’s test (n = 18), Deeks’ test (n = 12), Begg’s test (n = 5), both the Egger and Begg tests (n = 4), and other tests (n = 2). Our own comparison of the results of Begg’s, Egger’s and Deeks’ test for 92 meta-analyses indicated that up to 34% of the results did not correspond with one another.

Conclusions

The majority of DTA review authors mention or investigate publication bias. They mainly use suboptimal methods like the Begg and Egger tests that are not developed for DTA meta-analyses. Our comparison of the Begg, Egger and Deeks tests indicated that these tests do give different results and thus are not interchangeable. Deeks’ test is recommended for DTA meta-analyses and should be preferred.
Appendix
Available only for authorised users
Literature
1.
go back to reference Dickersin K: The existence of publication bias and risk factors for its occurrence. JAMA. 1990, 263: 1385-1389. 10.1001/jama.1990.03440100097014.CrossRefPubMed Dickersin K: The existence of publication bias and risk factors for its occurrence. JAMA. 1990, 263: 1385-1389. 10.1001/jama.1990.03440100097014.CrossRefPubMed
2.
go back to reference Egger M, Juni P, Bartlett C, Holenstein F, Sterne J: How important are comprehensive literature searches and the assessment of trial quality in systematic reviews? Empirical study. Health Technol Assess. 2003, 7: 1-76.PubMed Egger M, Juni P, Bartlett C, Holenstein F, Sterne J: How important are comprehensive literature searches and the assessment of trial quality in systematic reviews? Empirical study. Health Technol Assess. 2003, 7: 1-76.PubMed
3.
go back to reference Ioannidis JP, Cappelleri JC, Sacks HS, Lau J: The relationship between study design, results, and reporting of randomized clinical trials of HIV infection. Control Clin Trials. 1997, 18: 431-444. 10.1016/S0197-2456(97)00097-4.CrossRefPubMed Ioannidis JP, Cappelleri JC, Sacks HS, Lau J: The relationship between study design, results, and reporting of randomized clinical trials of HIV infection. Control Clin Trials. 1997, 18: 431-444. 10.1016/S0197-2456(97)00097-4.CrossRefPubMed
4.
go back to reference Ioannidis JP: Effect of the statistical significance of results on the time to completion and publication of randomized efficacy trials. JAMA. 1998, 279: 281-286. 10.1001/jama.279.4.281.CrossRefPubMed Ioannidis JP: Effect of the statistical significance of results on the time to completion and publication of randomized efficacy trials. JAMA. 1998, 279: 281-286. 10.1001/jama.279.4.281.CrossRefPubMed
5.
go back to reference Moher D, Fortin P, Jadad AR, Juni P, Klassen T, Le LJ, Liberati A, Linde K, Penna A: Completeness of reporting of trials published in languages other than English: implications for conduct and reporting of systematic reviews. Lancet. 1996, 347: 363-366. 10.1016/S0140-6736(96)90538-3.CrossRefPubMed Moher D, Fortin P, Jadad AR, Juni P, Klassen T, Le LJ, Liberati A, Linde K, Penna A: Completeness of reporting of trials published in languages other than English: implications for conduct and reporting of systematic reviews. Lancet. 1996, 347: 363-366. 10.1016/S0140-6736(96)90538-3.CrossRefPubMed
6.
go back to reference Sampson M, Platt R, StJohn PD, Moher D, Klassen TP, Pham B, Platt R, StJohn PD, Viola R, Raina P: Should meta-analysts search Embase in addition to Medline?. J Clin Epidemiol. 2003, 56: 943-955. 10.1016/S0895-4356(03)00110-0.CrossRefPubMed Sampson M, Platt R, StJohn PD, Moher D, Klassen TP, Pham B, Platt R, StJohn PD, Viola R, Raina P: Should meta-analysts search Embase in addition to Medline?. J Clin Epidemiol. 2003, 56: 943-955. 10.1016/S0895-4356(03)00110-0.CrossRefPubMed
7.
go back to reference Sterne JA, Gavaghan D, Egger M: Publication and related bias in meta-analysis: power of statistical tests and prevalence in the literature. J Clin Epidemiol. 2000, 53: 1119-1129. 10.1016/S0895-4356(00)00242-0.CrossRefPubMed Sterne JA, Gavaghan D, Egger M: Publication and related bias in meta-analysis: power of statistical tests and prevalence in the literature. J Clin Epidemiol. 2000, 53: 1119-1129. 10.1016/S0895-4356(00)00242-0.CrossRefPubMed
8.
go back to reference Thornton A, Lee P: Publication bias in meta-analysis: its causes and consequences. J Clin Epidemiol. 2000, 53: 207-216. 10.1016/S0895-4356(99)00161-4.CrossRefPubMed Thornton A, Lee P: Publication bias in meta-analysis: its causes and consequences. J Clin Epidemiol. 2000, 53: 207-216. 10.1016/S0895-4356(99)00161-4.CrossRefPubMed
9.
go back to reference Sterne JA, Sutton AJ, Ioannidis JP, Terrin N, Jones DR, Lau J, Carpenter J, Rucker G, Harbord RM, Schmid CH, Tetzlaff J, Deeks JJ, Peters J, Macaskill P, Schwarzer G, Duval S, Altman DG, Moher D, Higgins JP: Recommendations for examining and interpreting funnel plot asymmetry in meta-analyses of randomised controlled trials. BMJ. 2011, 343: d4002-10.1136/bmj.d4002.CrossRefPubMed Sterne JA, Sutton AJ, Ioannidis JP, Terrin N, Jones DR, Lau J, Carpenter J, Rucker G, Harbord RM, Schmid CH, Tetzlaff J, Deeks JJ, Peters J, Macaskill P, Schwarzer G, Duval S, Altman DG, Moher D, Higgins JP: Recommendations for examining and interpreting funnel plot asymmetry in meta-analyses of randomised controlled trials. BMJ. 2011, 343: d4002-10.1136/bmj.d4002.CrossRefPubMed
10.
go back to reference Sterne JA, Egger M, Moher D: Adressing reporting bias; detecting repoting bias. Cochrane Handbook for Systematic Reviews of Interventions. Edited by: Higgins JPT, Green S. 2009, Oxford, United Kingdom: Wiley-Blackwell, 310-324. Sterne JA, Egger M, Moher D: Adressing reporting bias; detecting repoting bias. Cochrane Handbook for Systematic Reviews of Interventions. Edited by: Higgins JPT, Green S. 2009, Oxford, United Kingdom: Wiley-Blackwell, 310-324.
11.
go back to reference Begg CB, Mazumdar M: Operating characteristics of a rank correlation test for publication bias. Biometrics. 1994, 50: 1088-1101. 10.2307/2533446.CrossRefPubMed Begg CB, Mazumdar M: Operating characteristics of a rank correlation test for publication bias. Biometrics. 1994, 50: 1088-1101. 10.2307/2533446.CrossRefPubMed
12.
go back to reference Egger M, Davey SG, Schneider M, Minder C: Bias in meta-analysis detected by a simple, graphical test. BMJ. 1997, 315: 629-634. 10.1136/bmj.315.7109.629.CrossRefPubMedPubMedCentral Egger M, Davey SG, Schneider M, Minder C: Bias in meta-analysis detected by a simple, graphical test. BMJ. 1997, 315: 629-634. 10.1136/bmj.315.7109.629.CrossRefPubMedPubMedCentral
13.
go back to reference Web of Knowledge: Edited by: Thomson R. 2014, New York, USA: Thomson Reuters Web of Knowledge: Edited by: Thomson R. 2014, New York, USA: Thomson Reuters
14.
go back to reference Macaskill P, Gatsonis C, Deeks JJ, Harbord RM, Takwoingi Y: Analysing and Presenting Results. Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy. Edited by: Deeks JJ, Bossuyt PM, Gatsonis C. 2010, Oxford, United Kingdom: The Cochrane Collaboration, 46-47. Macaskill P, Gatsonis C, Deeks JJ, Harbord RM, Takwoingi Y: Analysing and Presenting Results. Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy. Edited by: Deeks JJ, Bossuyt PM, Gatsonis C. 2010, Oxford, United Kingdom: The Cochrane Collaboration, 46-47.
15.
go back to reference Rifai N, Altman DG, Bossuyt PM: Reporting bias in diagnostic and prognostic studies: time for action. Clin Chem. 2008, 54: 1101-1103. 10.1373/clinchem.2008.108993.CrossRefPubMed Rifai N, Altman DG, Bossuyt PM: Reporting bias in diagnostic and prognostic studies: time for action. Clin Chem. 2008, 54: 1101-1103. 10.1373/clinchem.2008.108993.CrossRefPubMed
16.
go back to reference Korevaar DA, Ochodo EA, Bossuyt PM, Hooft L: Publication and Reporting of Test Accuracy Studies Registered in ClinicalTrials.gov. Clin Chem. 2014, 60: 651-659. 10.1373/clinchem.2013.218149.CrossRefPubMed Korevaar DA, Ochodo EA, Bossuyt PM, Hooft L: Publication and Reporting of Test Accuracy Studies Registered in ClinicalTrials.gov. Clin Chem. 2014, 60: 651-659. 10.1373/clinchem.2013.218149.CrossRefPubMed
17.
go back to reference Brazzelli M, Lewis SC, Deeks JJ, Sandercock PA: No evidence of bias in the process of publication of diagnostic accuracy studies in stroke submitted as abstracts. J Clin Epidemiol. 2009, 62: 425-430. 10.1016/j.jclinepi.2008.06.018.CrossRefPubMed Brazzelli M, Lewis SC, Deeks JJ, Sandercock PA: No evidence of bias in the process of publication of diagnostic accuracy studies in stroke submitted as abstracts. J Clin Epidemiol. 2009, 62: 425-430. 10.1016/j.jclinepi.2008.06.018.CrossRefPubMed
18.
go back to reference Song F, Khan KS, Dinnes J, Sutton AJ: Asymmetric funnel plots and publication bias in meta-analyses of diagnostic accuracy. Int J Epidemiol. 2002, 31: 88-95. 10.1093/ije/31.1.88.CrossRefPubMed Song F, Khan KS, Dinnes J, Sutton AJ: Asymmetric funnel plots and publication bias in meta-analyses of diagnostic accuracy. Int J Epidemiol. 2002, 31: 88-95. 10.1093/ije/31.1.88.CrossRefPubMed
19.
go back to reference Deeks JJ, Macaskill P, Irwig L: The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol. 2005, 58: 882-893. 10.1016/j.jclinepi.2005.01.016.CrossRefPubMed Deeks JJ, Macaskill P, Irwig L: The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol. 2005, 58: 882-893. 10.1016/j.jclinepi.2005.01.016.CrossRefPubMed
20.
go back to reference Deville WL, Bezemer PD, Bouter LM: Publications on diagnostic test evaluation in family medicine journals: an optimal search strategy. J Clin Epidemiol. 2000, 53: 65-69. 10.1016/S0895-4356(99)00144-4.CrossRefPubMed Deville WL, Bezemer PD, Bouter LM: Publications on diagnostic test evaluation in family medicine journals: an optimal search strategy. J Clin Epidemiol. 2000, 53: 65-69. 10.1016/S0895-4356(99)00144-4.CrossRefPubMed
21.
go back to reference Korevaar DA, van Enst WA, Spijker R, Bossuyt PM, Hooft L: Reporting quality of diagnostic accuracy studies: a systematic review and meta-analysis of investigations on adherence to STARD. Evid Based Med. 2014, 19: 47-54. 10.1136/eb-2013-101637.CrossRefPubMed Korevaar DA, van Enst WA, Spijker R, Bossuyt PM, Hooft L: Reporting quality of diagnostic accuracy studies: a systematic review and meta-analysis of investigations on adherence to STARD. Evid Based Med. 2014, 19: 47-54. 10.1136/eb-2013-101637.CrossRefPubMed
22.
go back to reference R Core Team: R: A Language and Environment for Statistical Computing. 2013, Vienna, Austria: R Foundation for Statistical Computing R Core Team: R: A Language and Environment for Statistical Computing. 2013, Vienna, Austria: R Foundation for Statistical Computing
23.
go back to reference Chang KC, Yew WW, Zhang Y: Pyrazinamide susceptibility testing in Mycobacterium tuberculosis: a systematic review with meta-analyses. Antimicrob Agents Chemother. 2011, 55: 4499-4505. 10.1128/AAC.00630-11.CrossRefPubMedPubMedCentral Chang KC, Yew WW, Zhang Y: Pyrazinamide susceptibility testing in Mycobacterium tuberculosis: a systematic review with meta-analyses. Antimicrob Agents Chemother. 2011, 55: 4499-4505. 10.1128/AAC.00630-11.CrossRefPubMedPubMedCentral
24.
go back to reference Chang MC, Chen JH, Liang JA, Lin CC, Yang KT, Cheng KY, Yeh JJ, Kao CH: Meta-analysis: comparison of F-18 fluorodeoxyglucose-positron emission tomography and bone scintigraphy in the detection of bone metastasis in patients with lung cancer. Acad Radiol. 2012, 19: 349-357. 10.1016/j.acra.2011.10.018.CrossRefPubMed Chang MC, Chen JH, Liang JA, Lin CC, Yang KT, Cheng KY, Yeh JJ, Kao CH: Meta-analysis: comparison of F-18 fluorodeoxyglucose-positron emission tomography and bone scintigraphy in the detection of bone metastasis in patients with lung cancer. Acad Radiol. 2012, 19: 349-357. 10.1016/j.acra.2011.10.018.CrossRefPubMed
25.
go back to reference Cheng X, Li Y, Xu Z, Bao L, Li D, Wang J: Comparison of 18 F-FDG PET/CT with bone scintigraphy for detection of bone metastasis: a meta-analysis. Acta Radiol. 2011, 52: 779-787. 10.1258/ar.2011.110115.CrossRefPubMed Cheng X, Li Y, Xu Z, Bao L, Li D, Wang J: Comparison of 18 F-FDG PET/CT with bone scintigraphy for detection of bone metastasis: a meta-analysis. Acta Radiol. 2011, 52: 779-787. 10.1258/ar.2011.110115.CrossRefPubMed
26.
go back to reference Descatha A, Huard L, Aubert F, Barbato B, Gorand O, Chastang JF: Meta-analysis on the performance of sonography for the diagnosis of carpal tunnel syndrome. Semin Arthritis Rheum. 2012, 41: 914-922. 10.1016/j.semarthrit.2011.11.006.CrossRefPubMed Descatha A, Huard L, Aubert F, Barbato B, Gorand O, Chastang JF: Meta-analysis on the performance of sonography for the diagnosis of carpal tunnel syndrome. Semin Arthritis Rheum. 2012, 41: 914-922. 10.1016/j.semarthrit.2011.11.006.CrossRefPubMed
27.
go back to reference Dong MJ, Zhao K, Liu ZF, Wang GL, Yang SY, Zhou GJ: A meta-analysis of the value of fluorodeoxyglucose-PET/PET-CT in the evaluation of fever of unknown origin. Eur J Radiol. 2011, 80: 834-844. 10.1016/j.ejrad.2010.11.018.CrossRefPubMed Dong MJ, Zhao K, Liu ZF, Wang GL, Yang SY, Zhou GJ: A meta-analysis of the value of fluorodeoxyglucose-PET/PET-CT in the evaluation of fever of unknown origin. Eur J Radiol. 2011, 80: 834-844. 10.1016/j.ejrad.2010.11.018.CrossRefPubMed
28.
go back to reference Dym RJ, Burns J, Freeman K, Lipton ML: Is functional MR imaging assessment of hemispheric language dominance as good as the Wada test?: a meta-analysis. Radiology. 2011, 261: 446-455. 10.1148/radiol.11101344.CrossRefPubMed Dym RJ, Burns J, Freeman K, Lipton ML: Is functional MR imaging assessment of hemispheric language dominance as good as the Wada test?: a meta-analysis. Radiology. 2011, 261: 446-455. 10.1148/radiol.11101344.CrossRefPubMed
29.
go back to reference Gao P, Li M, Tian QB, Liu DW: Diagnostic performance of des-gamma-carboxy prothrombin (DCP) for hepatocellular carcinoma: a bivariate meta-analysis. Neoplasma. 2012, 59: 150-159. 10.4149/neo_2012_020.CrossRefPubMed Gao P, Li M, Tian QB, Liu DW: Diagnostic performance of des-gamma-carboxy prothrombin (DCP) for hepatocellular carcinoma: a bivariate meta-analysis. Neoplasma. 2012, 59: 150-159. 10.4149/neo_2012_020.CrossRefPubMed
30.
go back to reference Gargiulo P, Petretta M, Bruzzese D, Cuocolo A, Prastaro M, D'Amore C, Vassallo E, Savarese G, Marciano C, Paolillo S, Filardi PP: Myocardial perfusion scintigraphy and echocardiography for detecting coronary artery disease in hypertensive patients: a meta-analysis. Eur J Nucl Med Mol Imaging. 2011, 38: 2040-2049. 10.1007/s00259-011-1891-0.CrossRefPubMed Gargiulo P, Petretta M, Bruzzese D, Cuocolo A, Prastaro M, D'Amore C, Vassallo E, Savarese G, Marciano C, Paolillo S, Filardi PP: Myocardial perfusion scintigraphy and echocardiography for detecting coronary artery disease in hypertensive patients: a meta-analysis. Eur J Nucl Med Mol Imaging. 2011, 38: 2040-2049. 10.1007/s00259-011-1891-0.CrossRefPubMed
31.
go back to reference Glasgow SC, Bleier JI, Burgart LJ, Finne CO, Lowry AC: Meta-analysis of histopathological features of primary colorectal cancers that predict lymph node metastases. J Gastrointest Surg. 2012, 16: 1019-1028. 10.1007/s11605-012-1827-4.CrossRefPubMed Glasgow SC, Bleier JI, Burgart LJ, Finne CO, Lowry AC: Meta-analysis of histopathological features of primary colorectal cancers that predict lymph node metastases. J Gastrointest Surg. 2012, 16: 1019-1028. 10.1007/s11605-012-1827-4.CrossRefPubMed
32.
go back to reference Gong X, Xu Q, Xu Z, Xiong P, Yan W, Chen Y: Real-time elastography for the differentiation of benign and malignant breast lesions: a meta-analysis. Breast Cancer Res Treat. 2011, 130: 11-18. 10.1007/s10549-011-1745-2.CrossRefPubMed Gong X, Xu Q, Xu Z, Xiong P, Yan W, Chen Y: Real-time elastography for the differentiation of benign and malignant breast lesions: a meta-analysis. Breast Cancer Res Treat. 2011, 130: 11-18. 10.1007/s10549-011-1745-2.CrossRefPubMed
33.
go back to reference Hernaez R, Lazo M, Bonekamp S, Kamel I, Brancati FL, Guallar E, Clark JM: Diagnostic accuracy and reliability of ultrasonography for the detection of fatty liver: a meta-analysis. Hepatology. 2011, 54: 1082-1090.CrossRefPubMedPubMedCentral Hernaez R, Lazo M, Bonekamp S, Kamel I, Brancati FL, Guallar E, Clark JM: Diagnostic accuracy and reliability of ultrasonography for the detection of fatty liver: a meta-analysis. Hepatology. 2011, 54: 1082-1090.CrossRefPubMedPubMedCentral
34.
go back to reference Inaba Y, Chen JA, Bergmann SR: Carotid plaque, compared with carotid intima-media thickness, more accurately predicts coronary artery disease events: a meta-analysis. Atherosclerosis. 2012, 220: 128-133. 10.1016/j.atherosclerosis.2011.06.044.CrossRefPubMed Inaba Y, Chen JA, Bergmann SR: Carotid plaque, compared with carotid intima-media thickness, more accurately predicts coronary artery disease events: a meta-analysis. Atherosclerosis. 2012, 220: 128-133. 10.1016/j.atherosclerosis.2011.06.044.CrossRefPubMed
35.
go back to reference Kobayashi Y, Hayashino Y, Jackson JL, Takagaki N, Hinotsu S, Kawakami K: Diagnostic performance of chromoendoscopy and narrow band imaging for colonic neoplasms: a meta-analysis. Colorectal Dis. 2012, 14: 18-28. 10.1111/j.1463-1318.2010.02449.x.CrossRefPubMed Kobayashi Y, Hayashino Y, Jackson JL, Takagaki N, Hinotsu S, Kawakami K: Diagnostic performance of chromoendoscopy and narrow band imaging for colonic neoplasms: a meta-analysis. Colorectal Dis. 2012, 14: 18-28. 10.1111/j.1463-1318.2010.02449.x.CrossRefPubMed
36.
go back to reference Li BS, Wang XY, Ma FL, Jiang B, Song XX, Xu AG: Is high resolution melting analysis (HRMA) accurate for detection of human disease-associated mutations? A meta analysis. PLoS One. 2011, 6: e28078-10.1371/journal.pone.0028078.CrossRefPubMedPubMedCentral Li BS, Wang XY, Ma FL, Jiang B, Song XX, Xu AG: Is high resolution melting analysis (HRMA) accurate for detection of human disease-associated mutations? A meta analysis. PLoS One. 2011, 6: e28078-10.1371/journal.pone.0028078.CrossRefPubMedPubMedCentral
37.
go back to reference Li R, Liu J, Xue H, Huang G: Diagnostic value of fecal tumor M2-pyruvate kinase for CRC screening: a systematic review and meta-analysis. Int J Cancer. 2012, 131: 1837-1845. 10.1002/ijc.27442.CrossRefPubMed Li R, Liu J, Xue H, Huang G: Diagnostic value of fecal tumor M2-pyruvate kinase for CRC screening: a systematic review and meta-analysis. Int J Cancer. 2012, 131: 1837-1845. 10.1002/ijc.27442.CrossRefPubMed
38.
go back to reference Lu Y, Chen YQ, Guo YL, Qin SM, Wu C, Wang K: Diagnosis of invasive fungal disease using serum (1– –>3)-beta-D-glucan: a bivariate meta-analysis. Intern Med. 2011, 50: 2783-2791. 10.2169/internalmedicine.50.6175.CrossRefPubMed Lu Y, Chen YQ, Guo YL, Qin SM, Wu C, Wang K: Diagnosis of invasive fungal disease using serum (1– –>3)-beta-D-glucan: a bivariate meta-analysis. Intern Med. 2011, 50: 2783-2791. 10.2169/internalmedicine.50.6175.CrossRefPubMed
39.
go back to reference Lundstrom LH, Vester-Andersen M, Moller AM, Charuluxananan S, L'hermite J, Wetterslev J: Poor prognostic value of the modified Mallampati score: a meta-analysis involving 177 088 patients. Br J Anaesth. 2011, 107: 659-667. 10.1093/bja/aer292.CrossRefPubMed Lundstrom LH, Vester-Andersen M, Moller AM, Charuluxananan S, L'hermite J, Wetterslev J: Poor prognostic value of the modified Mallampati score: a meta-analysis involving 177 088 patients. Br J Anaesth. 2011, 107: 659-667. 10.1093/bja/aer292.CrossRefPubMed
40.
go back to reference Luo YX, Chen DK, Song SX, Wang L, Wang JP: Aberrant methylation of genes in stool samples as diagnostic biomarkers for colorectal cancer or adenomas: a meta-analysis. Int J Clin Pract. 2011, 65: 1313-1320. 10.1111/j.1742-1241.2011.02800.x.CrossRefPubMed Luo YX, Chen DK, Song SX, Wang L, Wang JP: Aberrant methylation of genes in stool samples as diagnostic biomarkers for colorectal cancer or adenomas: a meta-analysis. Int J Clin Pract. 2011, 65: 1313-1320. 10.1111/j.1742-1241.2011.02800.x.CrossRefPubMed
41.
go back to reference Manea L, Gilbody S, McMillan D: Optimal cut-off score for diagnosing depression with the Patient Health Questionnaire (PHQ-9): a meta-analysis. CMAJ. 2012, 184: E191-E196. 10.1503/cmaj.110829.CrossRefPubMedPubMedCentral Manea L, Gilbody S, McMillan D: Optimal cut-off score for diagnosing depression with the Patient Health Questionnaire (PHQ-9): a meta-analysis. CMAJ. 2012, 184: E191-E196. 10.1503/cmaj.110829.CrossRefPubMedPubMedCentral
42.
go back to reference Mao R, Xiao YL, Gao X, Chen BL, He Y, Yang L, Hu PJ, Chen MH: Fecal calprotectin in predicting relapse of inflammatory bowel diseases: a meta-analysis of prospective studies. Inflamm Bowel Dis. 2012, 18: 1894-1899. 10.1002/ibd.22861.CrossRefPubMed Mao R, Xiao YL, Gao X, Chen BL, He Y, Yang L, Hu PJ, Chen MH: Fecal calprotectin in predicting relapse of inflammatory bowel diseases: a meta-analysis of prospective studies. Inflamm Bowel Dis. 2012, 18: 1894-1899. 10.1002/ibd.22861.CrossRefPubMed
43.
go back to reference Marton A, Xue X, Szilagyi A: Meta-analysis: the diagnostic accuracy of lactose breath hydrogen or lactose tolerance tests for predicting the North European lactase polymorphism C/T-13910. Aliment Pharmacol Ther. 2012, 35: 429-440. 10.1111/j.1365-2036.2011.04962.x.CrossRefPubMed Marton A, Xue X, Szilagyi A: Meta-analysis: the diagnostic accuracy of lactose breath hydrogen or lactose tolerance tests for predicting the North European lactase polymorphism C/T-13910. Aliment Pharmacol Ther. 2012, 35: 429-440. 10.1111/j.1365-2036.2011.04962.x.CrossRefPubMed
44.
go back to reference Mathews WC, Agmas W, Cachay E: Comparative accuracy of anal and cervical cytology in screening for moderate to severe dysplasia by magnification guided punch biopsy: a meta-analysis. PLoS One. 2011, 6: e24946-10.1371/journal.pone.0024946.CrossRefPubMedPubMedCentral Mathews WC, Agmas W, Cachay E: Comparative accuracy of anal and cervical cytology in screening for moderate to severe dysplasia by magnification guided punch biopsy: a meta-analysis. PLoS One. 2011, 6: e24946-10.1371/journal.pone.0024946.CrossRefPubMedPubMedCentral
45.
go back to reference McInnes MD, Kielar AZ, Macdonald DB: Percutaneous image-guided biopsy of the spleen: systematic review and meta-analysis of the complication rate and diagnostic accuracy. Radiology. 2011, 260: 699-708. 10.1148/radiol.11110333.CrossRefPubMed McInnes MD, Kielar AZ, Macdonald DB: Percutaneous image-guided biopsy of the spleen: systematic review and meta-analysis of the complication rate and diagnostic accuracy. Radiology. 2011, 260: 699-708. 10.1148/radiol.11110333.CrossRefPubMed
46.
go back to reference Meader N, Mitchell AJ, Chew-Graham C, Goldberg D, Rizzo M, Bird V, Kessler D, Packham J, Haddad M, Pilling S: Case identification of depression in patients with chronic physical health problems: a diagnostic accuracy meta-analysis of 113 studies. Br J Gen Pract. 2011, 61: e808-e820. 10.3399/bjgp11X613151.CrossRefPubMedPubMedCentral Meader N, Mitchell AJ, Chew-Graham C, Goldberg D, Rizzo M, Bird V, Kessler D, Packham J, Haddad M, Pilling S: Case identification of depression in patients with chronic physical health problems: a diagnostic accuracy meta-analysis of 113 studies. Br J Gen Pract. 2011, 61: e808-e820. 10.3399/bjgp11X613151.CrossRefPubMedPubMedCentral
47.
go back to reference Mitchell AJ, Meader N, Pentzek M: Clinical recognition of dementia and cognitive impairment in primary care: a meta-analysis of physician accuracy. Acta Psychiatr Scand. 2011, 124: 165-183. 10.1111/j.1600-0447.2011.01730.x.CrossRefPubMed Mitchell AJ, Meader N, Pentzek M: Clinical recognition of dementia and cognitive impairment in primary care: a meta-analysis of physician accuracy. Acta Psychiatr Scand. 2011, 124: 165-183. 10.1111/j.1600-0447.2011.01730.x.CrossRefPubMed
48.
go back to reference Onishi A, Sugiyama D, Kogata Y, Saegusa J, Sugimoto T, Kawano S, Morinobu A, Nishimura K, Kumagai S: Diagnostic accuracy of serum 1,3-beta-D-glucan for pneumocystis jiroveci pneumonia, invasive candidiasis, and invasive aspergillosis: systematic review and meta-analysis. J Clin Microbiol. 2012, 50: 7-15. 10.1128/JCM.05267-11.CrossRefPubMedPubMedCentral Onishi A, Sugiyama D, Kogata Y, Saegusa J, Sugimoto T, Kawano S, Morinobu A, Nishimura K, Kumagai S: Diagnostic accuracy of serum 1,3-beta-D-glucan for pneumocystis jiroveci pneumonia, invasive candidiasis, and invasive aspergillosis: systematic review and meta-analysis. J Clin Microbiol. 2012, 50: 7-15. 10.1128/JCM.05267-11.CrossRefPubMedPubMedCentral
49.
go back to reference Papathanasiou ND, Boutsiadis A, Dickson J, Bomanji JB: Diagnostic accuracy of (1)(2)(3)I-FP-CIT (DaTSCAN) in dementia with Lewy bodies: a meta-analysis of published studies. Parkinsonism Relat Disord. 2012, 18: 225-229. 10.1016/j.parkreldis.2011.09.015.CrossRefPubMed Papathanasiou ND, Boutsiadis A, Dickson J, Bomanji JB: Diagnostic accuracy of (1)(2)(3)I-FP-CIT (DaTSCAN) in dementia with Lewy bodies: a meta-analysis of published studies. Parkinsonism Relat Disord. 2012, 18: 225-229. 10.1016/j.parkreldis.2011.09.015.CrossRefPubMed
50.
go back to reference Plana MN, Carreira C, Muriel A, Chiva M, Abraira V, Emparanza JI, Bonfill X, Zamora J: Magnetic resonance imaging in the preoperative assessment of patients with primary breast cancer: systematic review of diagnostic accuracy and meta-analysis. Eur Radiol. 2012, 22: 26-38. 10.1007/s00330-011-2238-8.CrossRefPubMed Plana MN, Carreira C, Muriel A, Chiva M, Abraira V, Emparanza JI, Bonfill X, Zamora J: Magnetic resonance imaging in the preoperative assessment of patients with primary breast cancer: systematic review of diagnostic accuracy and meta-analysis. Eur Radiol. 2012, 22: 26-38. 10.1007/s00330-011-2238-8.CrossRefPubMed
51.
go back to reference Qu X, Huang X, Wu L, Huang G, Ping X, Yan W: Comparison of virtual cystoscopy and ultrasonography for bladder cancer detection: a meta-analysis. Eur J Radiol. 2011, 80: 188-197. 10.1016/j.ejrad.2010.04.003.CrossRefPubMed Qu X, Huang X, Wu L, Huang G, Ping X, Yan W: Comparison of virtual cystoscopy and ultrasonography for bladder cancer detection: a meta-analysis. Eur J Radiol. 2011, 80: 188-197. 10.1016/j.ejrad.2010.04.003.CrossRefPubMed
52.
go back to reference Sadeghi R, Gholami H, Zakavi SR, Kakhki VR, Tabasi KT, Horenblas S: Accuracy of sentinel lymph node biopsy for inguinal lymph node staging of penile squamous cell carcinoma: systematic review and meta-analysis of the literature. J Urol. 2012, 187: 25-31. 10.1016/j.juro.2011.09.058.CrossRefPubMed Sadeghi R, Gholami H, Zakavi SR, Kakhki VR, Tabasi KT, Horenblas S: Accuracy of sentinel lymph node biopsy for inguinal lymph node staging of penile squamous cell carcinoma: systematic review and meta-analysis of the literature. J Urol. 2012, 187: 25-31. 10.1016/j.juro.2011.09.058.CrossRefPubMed
53.
go back to reference Sadigh G, Carlos RC, Neal CH, Dwamena BA: Ultrasonographic differentiation of malignant from benign breast lesions: a meta-analytic comparison of elasticity and BIRADS scoring. Breast Cancer Res Treat. 2012, 133: 23-35. 10.1007/s10549-011-1857-8.CrossRefPubMed Sadigh G, Carlos RC, Neal CH, Dwamena BA: Ultrasonographic differentiation of malignant from benign breast lesions: a meta-analytic comparison of elasticity and BIRADS scoring. Breast Cancer Res Treat. 2012, 133: 23-35. 10.1007/s10549-011-1857-8.CrossRefPubMed
54.
go back to reference Summah H, Tao LL, Zhu YG, Jiang HN, Qu JM: Pleural fluid soluble triggering receptor expressed on myeloid cells-1 as a marker of bacterial infection: a meta-analysis. BMC Infect Dis. 2011, 11: 280-10.1186/1471-2334-11-280.CrossRefPubMedPubMedCentral Summah H, Tao LL, Zhu YG, Jiang HN, Qu JM: Pleural fluid soluble triggering receptor expressed on myeloid cells-1 as a marker of bacterial infection: a meta-analysis. BMC Infect Dis. 2011, 11: 280-10.1186/1471-2334-11-280.CrossRefPubMedPubMedCentral
55.
go back to reference Sun W, Wang K, Gao W, Su X, Qian Q, Lu X, Song Y, Guo Y, Shi Y: Evaluation of PCR on bronchoalveolar lavage fluid for diagnosis of invasive aspergillosis: a bivariate metaanalysis and systematic review. PLoS One. 2011, 6: e28467-10.1371/journal.pone.0028467.CrossRefPubMedPubMedCentral Sun W, Wang K, Gao W, Su X, Qian Q, Lu X, Song Y, Guo Y, Shi Y: Evaluation of PCR on bronchoalveolar lavage fluid for diagnosis of invasive aspergillosis: a bivariate metaanalysis and systematic review. PLoS One. 2011, 6: e28467-10.1371/journal.pone.0028467.CrossRefPubMedPubMedCentral
56.
go back to reference Takakuwa KM, Keith SW, Estepa AT, Shofer FS: A meta-analysis of 64-section coronary CT angiography findings for predicting 30-day major adverse cardiac events in patients presenting with symptoms suggestive of acute coronary syndrome. Acad Radiol. 2011, 18: 1522-1528. 10.1016/j.acra.2011.08.013.CrossRefPubMed Takakuwa KM, Keith SW, Estepa AT, Shofer FS: A meta-analysis of 64-section coronary CT angiography findings for predicting 30-day major adverse cardiac events in patients presenting with symptoms suggestive of acute coronary syndrome. Acad Radiol. 2011, 18: 1522-1528. 10.1016/j.acra.2011.08.013.CrossRefPubMed
57.
go back to reference Thosani N, Singh H, Kapadia A, Ochi N, Lee JH, Ajani J, Swisher SG, Hofstetter WL, Guha S, Bhutani MS: Diagnostic accuracy of EUS in differentiating mucosal versus submucosal invasion of superficial esophageal cancers: a systematic review and meta-analysis. Gastrointest Endosc. 2012, 75: 242-253. 10.1016/j.gie.2011.09.016.CrossRefPubMed Thosani N, Singh H, Kapadia A, Ochi N, Lee JH, Ajani J, Swisher SG, Hofstetter WL, Guha S, Bhutani MS: Diagnostic accuracy of EUS in differentiating mucosal versus submucosal invasion of superficial esophageal cancers: a systematic review and meta-analysis. Gastrointest Endosc. 2012, 75: 242-253. 10.1016/j.gie.2011.09.016.CrossRefPubMed
58.
go back to reference Tomasson G, Grayson PC, Mahr AD, Lavalley M, Merkel PA: Value of ANCA measurements during remission to predict a relapse of ANCA-associated vasculitis–a meta-analysis. Rheumatology (Oxford). 2012, 51: 100-109. 10.1093/rheumatology/ker280.CrossRef Tomasson G, Grayson PC, Mahr AD, Lavalley M, Merkel PA: Value of ANCA measurements during remission to predict a relapse of ANCA-associated vasculitis–a meta-analysis. Rheumatology (Oxford). 2012, 51: 100-109. 10.1093/rheumatology/ker280.CrossRef
59.
go back to reference Trallero-Araguas E, Rodrigo-Pendas JA, Selva-O'Callaghan A, Martinez-Gomez X, Bosch X, Labrador-Horrillo M, Grau-Junyent JM, Vilardell-Tarres M: Usefulness of anti-p155 autoantibody for diagnosing cancer-associated dermatomyositis: a systematic review and meta-analysis. Arthritis Rheum. 2012, 64: 523-532. 10.1002/art.33379.CrossRefPubMed Trallero-Araguas E, Rodrigo-Pendas JA, Selva-O'Callaghan A, Martinez-Gomez X, Bosch X, Labrador-Horrillo M, Grau-Junyent JM, Vilardell-Tarres M: Usefulness of anti-p155 autoantibody for diagnosing cancer-associated dermatomyositis: a systematic review and meta-analysis. Arthritis Rheum. 2012, 64: 523-532. 10.1002/art.33379.CrossRefPubMed
60.
go back to reference Wang GL, Zhao K, Liu ZF, Dong MJ, Yang SY: A meta-analysis of fluorodeoxyglucose-positron emission tomography versus scintigraphy in the evaluation of suspected osteomyelitis. Nucl Med Commun. 2011, 32: 1134-1142. 10.1097/MNM.0b013e32834b455c.CrossRefPubMed Wang GL, Zhao K, Liu ZF, Dong MJ, Yang SY: A meta-analysis of fluorodeoxyglucose-positron emission tomography versus scintigraphy in the evaluation of suspected osteomyelitis. Nucl Med Commun. 2011, 32: 1134-1142. 10.1097/MNM.0b013e32834b455c.CrossRefPubMed
61.
go back to reference Wang QB, Zhu H, Liu HL, Zhang B: Performance of magnetic resonance elastography and diffusion-weighted imaging for the staging of hepatic fibrosis: A meta-analysis. Hepatology. 2012, 56: 239-247. 10.1002/hep.25610.CrossRefPubMed Wang QB, Zhu H, Liu HL, Zhang B: Performance of magnetic resonance elastography and diffusion-weighted imaging for the staging of hepatic fibrosis: A meta-analysis. Hepatology. 2012, 56: 239-247. 10.1002/hep.25610.CrossRefPubMed
62.
go back to reference Wang W, Li Y, Li H, Xing Y, Qu G, Dai J, Liang Y: Immunodiagnostic efficacy of detection of Schistosoma japonicum human infections in China: a meta analysis. Asian Pac J Trop Med. 2012, 5: 15-23. 10.1016/S1995-7645(11)60238-1.CrossRefPubMed Wang W, Li Y, Li H, Xing Y, Qu G, Dai J, Liang Y: Immunodiagnostic efficacy of detection of Schistosoma japonicum human infections in China: a meta analysis. Asian Pac J Trop Med. 2012, 5: 15-23. 10.1016/S1995-7645(11)60238-1.CrossRefPubMed
63.
go back to reference Wang Y, Zhang C, Liu J, Huang G: Is 18 F-FDG PET accurate to predict neoadjuvant therapy response in breast cancer? A meta-analysis. Breast Cancer Res Treat. 2012, 131: 357-369. 10.1007/s10549-011-1780-z.CrossRefPubMed Wang Y, Zhang C, Liu J, Huang G: Is 18 F-FDG PET accurate to predict neoadjuvant therapy response in breast cancer? A meta-analysis. Breast Cancer Res Treat. 2012, 131: 357-369. 10.1007/s10549-011-1780-z.CrossRefPubMed
64.
go back to reference Wu LM, Xu JR, Liu MJ, Zhang XF, Hua J, Zheng J, Hu JN: Value of magnetic resonance imaging for nodal staging in patients with head and neck squamous cell carcinoma: a meta-analysis. Acad Radiol. 2012, 19: 331-340. 10.1016/j.acra.2011.10.027.CrossRefPubMed Wu LM, Xu JR, Liu MJ, Zhang XF, Hua J, Zheng J, Hu JN: Value of magnetic resonance imaging for nodal staging in patients with head and neck squamous cell carcinoma: a meta-analysis. Acad Radiol. 2012, 19: 331-340. 10.1016/j.acra.2011.10.027.CrossRefPubMed
65.
go back to reference Xu HB, Li L, Xu Q: Tc-99 m sestamibi scintimammography for the diagnosis of breast cancer: meta-analysis and meta-regression. Nucl Med Commun. 2011, 32: 980-988. 10.1097/MNM.0b013e32834b43a9.CrossRefPubMed Xu HB, Li L, Xu Q: Tc-99 m sestamibi scintimammography for the diagnosis of breast cancer: meta-analysis and meta-regression. Nucl Med Commun. 2011, 32: 980-988. 10.1097/MNM.0b013e32834b43a9.CrossRefPubMed
66.
go back to reference Xu W, Shi J, Zeng X, Li X, Xie WF, Guo J, Lin Y: EUS elastography for the differentiation of benign and malignant lymph nodes: a meta-analysis. Gastrointest Endosc. 2011, 74: 1001-1009. 10.1016/j.gie.2011.07.026.CrossRefPubMed Xu W, Shi J, Zeng X, Li X, Xie WF, Guo J, Lin Y: EUS elastography for the differentiation of benign and malignant lymph nodes: a meta-analysis. Gastrointest Endosc. 2011, 74: 1001-1009. 10.1016/j.gie.2011.07.026.CrossRefPubMed
67.
go back to reference Ying L, Hou Y, Zheng HM, Lin X, Xie ZL, Hu YP: Real-time elastography for the differentiation of benign and malignant superficial lymph nodes: a meta-analysis. Eur J Radiol. 2012, 81: 2576-2584. 10.1016/j.ejrad.2011.10.026.CrossRefPubMed Ying L, Hou Y, Zheng HM, Lin X, Xie ZL, Hu YP: Real-time elastography for the differentiation of benign and malignant superficial lymph nodes: a meta-analysis. Eur J Radiol. 2012, 81: 2576-2584. 10.1016/j.ejrad.2011.10.026.CrossRefPubMed
68.
go back to reference Yu YH, Wei W, Liu JL: Diagnostic value of fine-needle aspiration biopsy for breast mass: a systematic review and meta-analysis. BMC Cancer. 2012, 12: 41-10.1186/1471-2407-12-41.CrossRefPubMedPubMedCentral Yu YH, Wei W, Liu JL: Diagnostic value of fine-needle aspiration biopsy for breast mass: a systematic review and meta-analysis. BMC Cancer. 2012, 12: 41-10.1186/1471-2407-12-41.CrossRefPubMedPubMedCentral
69.
go back to reference Zhang L, Zong ZY, Liu YB, Ye H, Lv XJ: PCR versus serology for diagnosing Mycoplasma pneumoniae infection: a systematic review & meta-analysis. Indian J Med Res. 2011, 134: 270-280.PubMedPubMedCentral Zhang L, Zong ZY, Liu YB, Ye H, Lv XJ: PCR versus serology for diagnosing Mycoplasma pneumoniae infection: a systematic review & meta-analysis. Indian J Med Res. 2011, 134: 270-280.PubMedPubMedCentral
70.
go back to reference Harbord RM, Egger M, Sterne JA: A modified test for small-study effects in meta-analyses of controlled trials with binary endpoints. Stat Med. 2006, 25: 3443-3457. 10.1002/sim.2380.CrossRefPubMed Harbord RM, Egger M, Sterne JA: A modified test for small-study effects in meta-analyses of controlled trials with binary endpoints. Stat Med. 2006, 25: 3443-3457. 10.1002/sim.2380.CrossRefPubMed
71.
go back to reference Hazem A, Elamin MB, Malaga G, Bancos I, Prevost Y, Zeballos-Palacios C, Velasquez ER, Erwin PJ, Natt N, Montori VM, Murad MH: The accuracy of diagnostic tests for GH deficiency in adults: a systematic review and meta-analysis. Eur J Endocrinol. 2011, 165: 841-849. 10.1530/EJE-11-0476.CrossRefPubMed Hazem A, Elamin MB, Malaga G, Bancos I, Prevost Y, Zeballos-Palacios C, Velasquez ER, Erwin PJ, Natt N, Montori VM, Murad MH: The accuracy of diagnostic tests for GH deficiency in adults: a systematic review and meta-analysis. Eur J Endocrinol. 2011, 165: 841-849. 10.1530/EJE-11-0476.CrossRefPubMed
72.
go back to reference Singh B, Parsaik AK, Agarwal D, Surana A, Mascarenhas SS, Chandra S: Diagnostic accuracy of pulmonary embolism rule-out criteria: a systematic review and meta-analysis. Ann Emerg Med. 2012, 59: 517-520. 10.1016/j.annemergmed.2011.10.022.CrossRefPubMed Singh B, Parsaik AK, Agarwal D, Surana A, Mascarenhas SS, Chandra S: Diagnostic accuracy of pulmonary embolism rule-out criteria: a systematic review and meta-analysis. Ann Emerg Med. 2012, 59: 517-520. 10.1016/j.annemergmed.2011.10.022.CrossRefPubMed
73.
go back to reference Parekh-Bhurke S, Kwok CS, Pang C, Hooper L, Loke YK, Ryder JJ, Sutton AJ, Hing CB, Harvey I, Song F: Uptake of methods to deal with publication bias in systematic reviews has increased over time, but there is still much scope for improvement. J Clin Epidemiol. 2011, 64: 349-357. 10.1016/j.jclinepi.2010.04.022.CrossRefPubMed Parekh-Bhurke S, Kwok CS, Pang C, Hooper L, Loke YK, Ryder JJ, Sutton AJ, Hing CB, Harvey I, Song F: Uptake of methods to deal with publication bias in systematic reviews has increased over time, but there is still much scope for improvement. J Clin Epidemiol. 2011, 64: 349-357. 10.1016/j.jclinepi.2010.04.022.CrossRefPubMed
74.
go back to reference Burkner PC, Doebler P: Testing for publication bias in diagnostic meta-analysis: a simulation study. Stat Med. 2014 Burkner PC, Doebler P: Testing for publication bias in diagnostic meta-analysis: a simulation study. Stat Med. 2014
75.
go back to reference de Vet HCW, Eisinga A, Riphagen , Aertgeerts B, Pewsner D: Searching for Studies. Cochrane Handbook for Systematic Reviews of Diagnosic Test Accuracy. 0.4 edition. Edited by: The Cochrane Collaboration. 2008 de Vet HCW, Eisinga A, Riphagen , Aertgeerts B, Pewsner D: Searching for Studies. Cochrane Handbook for Systematic Reviews of Diagnosic Test Accuracy. 0.4 edition. Edited by: The Cochrane Collaboration. 2008
76.
go back to reference Li CR, Liao CT, Liu JP: A non-inferiority test for diagnostic accuracy based on the paired partial areas under ROC curves. Stat Med. 2008, 27: 1762-1776. 10.1002/sim.3121.CrossRefPubMed Li CR, Liao CT, Liu JP: A non-inferiority test for diagnostic accuracy based on the paired partial areas under ROC curves. Stat Med. 2008, 27: 1762-1776. 10.1002/sim.3121.CrossRefPubMed
77.
go back to reference Liu JP, Ma MC, Wu CY, Tai JY: Tests of equivalence and non-inferiority for diagnostic accuracy based on the paired areas under ROC curves. Stat Med. 2006, 25: 1219-1238. 10.1002/sim.2358.CrossRefPubMed Liu JP, Ma MC, Wu CY, Tai JY: Tests of equivalence and non-inferiority for diagnostic accuracy based on the paired areas under ROC curves. Stat Med. 2006, 25: 1219-1238. 10.1002/sim.2358.CrossRefPubMed
78.
go back to reference DeAngelis CD, Drazen JM, Frizelle FA, Haug C, Hoey J, Horton R, Kotzin S, Laine C, Marusic A, Overbeke AJ, Schroeder TV, Sox HC, Van Der Weyden MB: Clinical trial registration: a statement from the International Committee of Medical Journal Editors. Ann Intern Med. 2004, 141: 477-478. 10.7326/0003-4819-141-6-200409210-00109.CrossRef DeAngelis CD, Drazen JM, Frizelle FA, Haug C, Hoey J, Horton R, Kotzin S, Laine C, Marusic A, Overbeke AJ, Schroeder TV, Sox HC, Van Der Weyden MB: Clinical trial registration: a statement from the International Committee of Medical Journal Editors. Ann Intern Med. 2004, 141: 477-478. 10.7326/0003-4819-141-6-200409210-00109.CrossRef
Metadata
Title
Investigation of publication bias in meta-analyses of diagnostic test accuracy: a meta-epidemiological study
Authors
W Annefloor van Enst
Eleanor Ochodo
Rob JPM Scholten
Lotty Hooft
Mariska M Leeflang
Publication date
01-12-2014
Publisher
BioMed Central
Published in
BMC Medical Research Methodology / Issue 1/2014
Electronic ISSN: 1471-2288
DOI
https://doi.org/10.1186/1471-2288-14-70

Other articles of this Issue 1/2014

BMC Medical Research Methodology 1/2014 Go to the issue