Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2022

Open Access 01-12-2022 | Hip-TEP | Research article

Determining the accuracy of preoperative total hip replacement 2D templating using the mediCAD® software

Authors: Seyed Peyman Mirghaderi, Sadula Sharifpour, Alireza Moharrami, Negar Ahmadi, Rangarirai Makuku, Maryam Salimi, Seyed Mohammad Javad Mortazavi

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2022

Login to get access

Abstract

Background

Templating is a preoperative planning procedure that improves the efficiency of the surgical process and reduces postoperative complications of total hip arthroplasty (THA) by improving the precision of prediction of prosthetic implant size. This study aimed to evaluate the accuracy of the preoperative cup and stem size digital 2D templating of THA with mediCAD® software and find the factors that influence the accuracy, such as indication for surgery, patients’ demographics, implant brand, and the assessors’ grade of education.

Methods

We retrospectively retrieved 420 patient template images of all patients who underwent THA between March 2018 and March 2021. Templating of all included images was processed using mediCAD® software a day before surgery by a newcomer physician to hip arthroplasty course (PGY-2 orthopedic resident or hip surgery fellow). Preoperative templating cup and stem sizes were compared with the actual inserted implant sizes.

Result

After excluding ineligible patients, this study included 391 patients, 193 (49.4%) males and 198 (50.6%) females with a mean age of 43.3 ± 14.9. The average cup sizes predicted before and after surgery were 52.12 ± 14.28 and 52.21 ± 15.05 respectively, and the mean delta cup size (before and after surgery) was 2.79 ± 2.94. The delta stem size before and after surgery has a mean value of 1.53 ± 1.49. The acetabular cup components, measured within ± 0, ± 1, and ± 2 sizes, were 28.9%, 63.9%, 83.1% accurate, respectively. The femoral stem design component measured within ± 0, ± 1, and ± 2 sizes were 27.2%, 61.0%, 78.6% accurate, respectively. Wagner Cone® stem brand, DDH patients, and females showed significantly higher accuracy of stem size templating. Revision THA has the lowest accuracy in terms of cup size templating. The compression of accuracy rate between resident and fellow revealed no significant differences. Also, no significant difference was detected between the accuracy of templating performed in the first months with the second months of the arthroplasty course period.

Conclusion

Our study showed that under mentioned condition, templating using mediCAD® has acceptable accuracy in predicting the sizes of femoral and acetabular components in THA patients. Digital software like mediCAD® remains favorable because of the short learning curve, user-friendly features, and low-cost maintenance, leading to level-up patient care and THA efficacy. Further studies are necessary for clarifying the role of the assessor’s experience and expertise in THA preoperative templating.

Level of evidence

Level III (retrospective observational study).
Literature
2.
go back to reference Sheikhbahaei E, Mirghaderi SP, Moharrami A, Habibi D, Motififard M, Javad Mortazavi SM. Incidence of symptomatic COVID-19 in unvaccinated patients within one month after elective total joint arthroplasty: a multicentre study. Arthroplasty Today. 2022;14:110-5. Sheikhbahaei E, Mirghaderi SP, Moharrami A, Habibi D, Motififard M, Javad Mortazavi SM. Incidence of symptomatic COVID-19 in unvaccinated patients within one month after elective total joint arthroplasty: a multicentre study. Arthroplasty Today. 2022;14:110-5.
3.
go back to reference Shi XT, Li CF, Han Y, Song Y, Li SX, Liu JG. Total hip arthroplasty for crowe type IV hip dysplasia: surgical techniques and postoperative complications. Orthop Surg. 2019;11(6):966–73.CrossRef Shi XT, Li CF, Han Y, Song Y, Li SX, Liu JG. Total hip arthroplasty for crowe type IV hip dysplasia: surgical techniques and postoperative complications. Orthop Surg. 2019;11(6):966–73.CrossRef
4.
go back to reference Rahm S, Zingg PO. Indications for joint replacement: total hip arthroplasty. Z Rheumatol. 2018;77(1):55–65.CrossRef Rahm S, Zingg PO. Indications for joint replacement: total hip arthroplasty. Z Rheumatol. 2018;77(1):55–65.CrossRef
5.
go back to reference Alnahhal A, Aslam-Pervez N, Sheikh HQ. Templating hip arthroplasty. Open Access Maced J Med Sci. 2019;7(4):672–85.CrossRef Alnahhal A, Aslam-Pervez N, Sheikh HQ. Templating hip arthroplasty. Open Access Maced J Med Sci. 2019;7(4):672–85.CrossRef
6.
go back to reference Schmidutz F, Steinbrück A, Wanke-Jellinek L, Pietschmann M, Jansson V, Fottner A. The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty. Int Orthop. 2012;36(9):1767–72.CrossRef Schmidutz F, Steinbrück A, Wanke-Jellinek L, Pietschmann M, Jansson V, Fottner A. The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty. Int Orthop. 2012;36(9):1767–72.CrossRef
7.
go back to reference Carter LW, Stovall DO, Young TR. Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty. 1995;10(4):507–13.CrossRef Carter LW, Stovall DO, Young TR. Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty. 1995;10(4):507–13.CrossRef
8.
go back to reference Valle AGD, Slullitel G, Piccaluga F, Salvati EA. The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty. 2005;20(1):51–8.CrossRef Valle AGD, Slullitel G, Piccaluga F, Salvati EA. The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty. 2005;20(1):51–8.CrossRef
9.
go back to reference Olsen M, Gamble P, Chiu M, Tumia N, Boyle RA, Schemitsch EH. Assessment of accuracy and reliability in preoperative templating for hip resurfacing arthroplasty. J Arthroplasty. 2010;25(3):445–9.CrossRef Olsen M, Gamble P, Chiu M, Tumia N, Boyle RA, Schemitsch EH. Assessment of accuracy and reliability in preoperative templating for hip resurfacing arthroplasty. J Arthroplasty. 2010;25(3):445–9.CrossRef
10.
go back to reference Gómez LFU, Gaitán-Lee H, Duarte MA, Halley PD, Jaramillo AR, García EL. Precision and accuracy of pre-surgical planning of non-cemented total hip replacement with calibrated digital images and acetates. J Orthop Surg Res. 2021;16(1):431.CrossRef Gómez LFU, Gaitán-Lee H, Duarte MA, Halley PD, Jaramillo AR, García EL. Precision and accuracy of pre-surgical planning of non-cemented total hip replacement with calibrated digital images and acetates. J Orthop Surg Res. 2021;16(1):431.CrossRef
11.
go back to reference Kosashvili Y, Shasha N, Olschewski E, Safir O, White L, Gross A, et al. Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty. Can J Surg. 2009;52(1):6–11.PubMedPubMedCentral Kosashvili Y, Shasha N, Olschewski E, Safir O, White L, Gross A, et al. Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty. Can J Surg. 2009;52(1):6–11.PubMedPubMedCentral
12.
go back to reference Williams MB, Krupinski EA, Strauss KJ, Breeden WK 3rd, Rzeszotarski MS, Applegate K, et al. Digital radiography image quality: image acquisition. J Am Coll Radiol JACR. 2007;4(6):371–88.CrossRef Williams MB, Krupinski EA, Strauss KJ, Breeden WK 3rd, Rzeszotarski MS, Applegate K, et al. Digital radiography image quality: image acquisition. J Am Coll Radiol JACR. 2007;4(6):371–88.CrossRef
13.
go back to reference González Della Valle A, Slullitel G, Piccaluga F, Salvati EA. The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplast. 2005;20(1):51–8.CrossRef González Della Valle A, Slullitel G, Piccaluga F, Salvati EA. The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplast. 2005;20(1):51–8.CrossRef
14.
go back to reference The B, Diercks RL, van Ooijen PM, van Horn JR. Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop. 2005;76(1):78–84.CrossRef The B, Diercks RL, van Ooijen PM, van Horn JR. Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop. 2005;76(1):78–84.CrossRef
15.
go back to reference Colombi A, Schena D, Castelli CC. Total hip arthroplasty planning. EFORT Open Rev. 2019;4(11):626–32.CrossRef Colombi A, Schena D, Castelli CC. Total hip arthroplasty planning. EFORT Open Rev. 2019;4(11):626–32.CrossRef
16.
go back to reference Bishi H, Smith JBV, Asopa V, Field RE, Wang C, Sochart DH. Comparison of the accuracy of 2D and 3D templating methods for planning primary total hip replacement: a systematic review and meta-analysis. EFORT Open Rev. 2022;7(1):70–83.CrossRef Bishi H, Smith JBV, Asopa V, Field RE, Wang C, Sochart DH. Comparison of the accuracy of 2D and 3D templating methods for planning primary total hip replacement: a systematic review and meta-analysis. EFORT Open Rev. 2022;7(1):70–83.CrossRef
17.
go back to reference Wedemeyer C, Quitmann H, Xu J, Heep H, Knoch M, Saxler G. Digital templating in total hip arthroplasty with the Mayo stem. Archiv Orthop Trauma Surg. 2007;128:1023–9.CrossRef Wedemeyer C, Quitmann H, Xu J, Heep H, Knoch M, Saxler G. Digital templating in total hip arthroplasty with the Mayo stem. Archiv Orthop Trauma Surg. 2007;128:1023–9.CrossRef
18.
go back to reference Zhang HL, Zheng L, Wang WC, Luo YH, Wang L, Mao XZ. A new and improved acetabular cup digital templating method and its clinical application. Musculoskelet Surg. 2022;106(1):49-58. Zhang HL, Zheng L, Wang WC, Luo YH, Wang L, Mao XZ. A new and improved acetabular cup digital templating method and its clinical application. Musculoskelet Surg. 2022;106(1):49-58.
19.
go back to reference Pongkunakorn A, Aksornthung C, Sritumpinit N. Accuracy of a new digital templating method for total hip arthroplasty using picture archiving and communication system (PACS) and iPhone technology: comparison with acetate templating on digital radiography. J Arthroplasty. 2021;36(6):2204–10.CrossRef Pongkunakorn A, Aksornthung C, Sritumpinit N. Accuracy of a new digital templating method for total hip arthroplasty using picture archiving and communication system (PACS) and iPhone technology: comparison with acetate templating on digital radiography. J Arthroplasty. 2021;36(6):2204–10.CrossRef
20.
go back to reference Steinberg EL, Shasha N, Menahem A, Dekel S. Preoperative planning of total hip replacement using the TraumaCad™ system. Arch Orthop Trauma Surg. 2010;130(12):1429–32.CrossRef Steinberg EL, Shasha N, Menahem A, Dekel S. Preoperative planning of total hip replacement using the TraumaCad™ system. Arch Orthop Trauma Surg. 2010;130(12):1429–32.CrossRef
21.
go back to reference Davila JA, Kransdorf MJ, Duffy GP. Surgical planning of total hip arthroplasty: accuracy of computer-assisted EndoMap software in predicting component size. Skelet Radiol. 2006;35(6):390–3.CrossRef Davila JA, Kransdorf MJ, Duffy GP. Surgical planning of total hip arthroplasty: accuracy of computer-assisted EndoMap software in predicting component size. Skelet Radiol. 2006;35(6):390–3.CrossRef
22.
go back to reference Buller LT, McLawhorn AS, Maratt JD, Carroll KM, Mayman DJ. EOS imaging is accurate and reproducible for preoperative total hip arthroplasty templating. J Arthroplasty. 2021;36(3):1143–8.CrossRef Buller LT, McLawhorn AS, Maratt JD, Carroll KM, Mayman DJ. EOS imaging is accurate and reproducible for preoperative total hip arthroplasty templating. J Arthroplasty. 2021;36(3):1143–8.CrossRef
23.
go back to reference Кoлecникoвa A, Caфoнoв P, Дoнник A, editors. Bocтpeбoвaннocть пpoгpaммнo-aнaлитичecкиx cиcтeм пpeдoпepaциoннoгo плaниpoвaния в oблacти cпинaльнoй xиpypгии. Пpaктичecкaя биoмexaникa; 2016. Кoлecникoвa A, Caфoнoв P, Дoнник A, editors. Bocтpeбoвaннocть пpoгpaммнo-aнaлитичecкиx cиcтeм пpeдoпepaциoннoгo плaниpoвaния в oблacти cпинaльнoй xиpypгии. Пpaктичecкaя биoмexaникa; 2016.
24.
go back to reference Fedonnikov A, Kovtun A, Kossovich L, Kirillova I, Kolesnikova A, Norkin I. Preoperative planning software in vertebrology: issues and outlook. Russ Open Med J. 2017;6:e0408.CrossRef Fedonnikov A, Kovtun A, Kossovich L, Kirillova I, Kolesnikova A, Norkin I. Preoperative planning software in vertebrology: issues and outlook. Russ Open Med J. 2017;6:e0408.CrossRef
25.
go back to reference Anna SK, Aleksander SF, Irina VK, Andrey VT, Alexey LK, Alexey ES, et al., editors. Geometric planning in vertebral and pelvic complex surgery: sufficient number of evaluating parameters proving. ProcSPIE. 2019. Anna SK, Aleksander SF, Irina VK, Andrey VT, Alexey LK, Alexey ES, et al., editors. Geometric planning in vertebral and pelvic complex surgery: sufficient number of evaluating parameters proving. ProcSPIE. 2019.
26.
go back to reference Huo J, Huang G, Han D, Wang X, Bu Y, Chen Y, et al. Value of 3D preoperative planning for primary total hip arthroplasty based on artificial intelligence technology. J Orthop Surg Res. 2021;16(1):156.CrossRef Huo J, Huang G, Han D, Wang X, Bu Y, Chen Y, et al. Value of 3D preoperative planning for primary total hip arthroplasty based on artificial intelligence technology. J Orthop Surg Res. 2021;16(1):156.CrossRef
27.
go back to reference Ding X, Zhang B, Li W, Huo J, Liu S, Wu T, et al. Value of preoperative three-dimensional planning software (AI-HIP) in primary total hip arthroplasty: a retrospective study. J Int Med Res. 2021;49(11):03000605211058874.PubMedCentral Ding X, Zhang B, Li W, Huo J, Liu S, Wu T, et al. Value of preoperative three-dimensional planning software (AI-HIP) in primary total hip arthroplasty: a retrospective study. J Int Med Res. 2021;49(11):03000605211058874.PubMedCentral
28.
go back to reference The B, Verdonschot N, van Horn JR, van Ooijen PMA, Diercks RL. Digital versus analogue preoperative planning of total hip arthroplasties: a randomized clinical trial of 210 total hip arthroplasties. J Arthroplasty. 2007;22(6):866–70.CrossRef The B, Verdonschot N, van Horn JR, van Ooijen PMA, Diercks RL. Digital versus analogue preoperative planning of total hip arthroplasties: a randomized clinical trial of 210 total hip arthroplasties. J Arthroplasty. 2007;22(6):866–70.CrossRef
29.
go back to reference Crooijmans HJA, Laumen AMRP, van Pul C, van Mourik JBA. A new digital preoperative planning method for total hip arthroplasties. Clin Orthop Relat Res. 2009;467(4):909–16.CrossRef Crooijmans HJA, Laumen AMRP, van Pul C, van Mourik JBA. A new digital preoperative planning method for total hip arthroplasties. Clin Orthop Relat Res. 2009;467(4):909–16.CrossRef
30.
go back to reference Wiese KR, Kock FW, Blake CA, Franken T, Jordaan JD. The accuracy of pre-operative digital templating in total hip arthroplasty performed in a low-volume, resource-constrained orthopaedic unit. SA Orthop J. 2020;19(1):28–32.CrossRef Wiese KR, Kock FW, Blake CA, Franken T, Jordaan JD. The accuracy of pre-operative digital templating in total hip arthroplasty performed in a low-volume, resource-constrained orthopaedic unit. SA Orthop J. 2020;19(1):28–32.CrossRef
31.
go back to reference Choi JK, Geller JA, Wang W, Nyce JD, Macaulay W. The accuracy and reliability of preoperative templating for metal-on-metal hip resurfacing. J Arthroplasty. 2011;26(5):765–70.CrossRef Choi JK, Geller JA, Wang W, Nyce JD, Macaulay W. The accuracy and reliability of preoperative templating for metal-on-metal hip resurfacing. J Arthroplasty. 2011;26(5):765–70.CrossRef
32.
go back to reference Efe T, El Zayat BF, Heyse TJ, Timmesfeld N, Fuchs-Winkelmann S, Schmitt J. Precision of preoperative digital templating in total hip arthroplasty. Acta Orthop Belg. 2011;77(5):616–21.PubMed Efe T, El Zayat BF, Heyse TJ, Timmesfeld N, Fuchs-Winkelmann S, Schmitt J. Precision of preoperative digital templating in total hip arthroplasty. Acta Orthop Belg. 2011;77(5):616–21.PubMed
33.
go back to reference Shin JK, Son SM, Kim TW, Shin WC, Lee JS, Suh KT. Accuracy and reliability of preoperative on-screen templating using digital radiographs for total hip arthroplasty. Hip Pelvis. 2016;28(4):201–7.CrossRef Shin JK, Son SM, Kim TW, Shin WC, Lee JS, Suh KT. Accuracy and reliability of preoperative on-screen templating using digital radiographs for total hip arthroplasty. Hip Pelvis. 2016;28(4):201–7.CrossRef
34.
go back to reference Whiddon DR, Bono JV, Lang JE, Smith EL, Salyapongse AK. Accuracy of digital templating in total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2011;40(8):395–8. Whiddon DR, Bono JV, Lang JE, Smith EL, Salyapongse AK. Accuracy of digital templating in total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2011;40(8):395–8.
35.
go back to reference Gamble P, de Beer J, Petruccelli D, Winemaker M. The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplasty. 2010;25(4):529–32.CrossRef Gamble P, de Beer J, Petruccelli D, Winemaker M. The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplasty. 2010;25(4):529–32.CrossRef
36.
go back to reference Kristoffersson E, Otten V, Crnalic S. The accuracy of digital templating in cementless total hip arthroplasty in dysplastic hips. BMC Musculoskelet Disord. 2021;22(1):942.CrossRef Kristoffersson E, Otten V, Crnalic S. The accuracy of digital templating in cementless total hip arthroplasty in dysplastic hips. BMC Musculoskelet Disord. 2021;22(1):942.CrossRef
37.
go back to reference Wedemeyer C, Quitmann H, Xu J, Heep H, von Knoch M, Saxler G. Digital templating in total hip arthroplasty with the Mayo stem. Arch Orthop Trauma Surg. 2008;128(10):1023–9.CrossRef Wedemeyer C, Quitmann H, Xu J, Heep H, von Knoch M, Saxler G. Digital templating in total hip arthroplasty with the Mayo stem. Arch Orthop Trauma Surg. 2008;128(10):1023–9.CrossRef
38.
go back to reference Schiffner E, Latz D, Jungbluth P, Grassmann JP, Tanner S, Karbowski A, et al. Is computerised 3D templating more accurate than 2D templating to predict size of components in primary total hip arthroplasty? Hip Int. 2019;29(3):270–5.CrossRef Schiffner E, Latz D, Jungbluth P, Grassmann JP, Tanner S, Karbowski A, et al. Is computerised 3D templating more accurate than 2D templating to predict size of components in primary total hip arthroplasty? Hip Int. 2019;29(3):270–5.CrossRef
39.
go back to reference Ding X, Zhang B, Li W, Huo J, Liu S, Wu T, et al. Value of preoperative three-dimensional planning software (AI-HIP) in primary total hip arthroplasty: a retrospective study. J Int Med Res. 2021;49(11):3000605211058874.PubMed Ding X, Zhang B, Li W, Huo J, Liu S, Wu T, et al. Value of preoperative three-dimensional planning software (AI-HIP) in primary total hip arthroplasty: a retrospective study. J Int Med Res. 2021;49(11):3000605211058874.PubMed
40.
go back to reference Eggli S, Pisan M, Müller ME. The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br Vol. 1998;80(3):382–90.CrossRef Eggli S, Pisan M, Müller ME. The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br Vol. 1998;80(3):382–90.CrossRef
41.
go back to reference Dutka J, Kiepura S, Bukowczan M. Is analog preoperative planning still applicable?-comparison of accuracy of analog and computer preoperative planning methods in total hip arthroplasty. Ann Transl Med. 2021;9(9):749.CrossRef Dutka J, Kiepura S, Bukowczan M. Is analog preoperative planning still applicable?-comparison of accuracy of analog and computer preoperative planning methods in total hip arthroplasty. Ann Transl Med. 2021;9(9):749.CrossRef
42.
go back to reference Shaarani SR, McHugh G, Collins DA. Accuracy of digital preoperative templating in 100 consecutive uncemented total hip arthroplasties: a single surgeon series. J Arthroplasty. 2013;28(2):331–7.CrossRef Shaarani SR, McHugh G, Collins DA. Accuracy of digital preoperative templating in 100 consecutive uncemented total hip arthroplasties: a single surgeon series. J Arthroplasty. 2013;28(2):331–7.CrossRef
Metadata
Title
Determining the accuracy of preoperative total hip replacement 2D templating using the mediCAD® software
Authors
Seyed Peyman Mirghaderi
Sadula Sharifpour
Alireza Moharrami
Negar Ahmadi
Rangarirai Makuku
Maryam Salimi
Seyed Mohammad Javad Mortazavi
Publication date
01-12-2022
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2022
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-022-03086-5

Other articles of this Issue 1/2022

Journal of Orthopaedic Surgery and Research 1/2022 Go to the issue