Skip to main content
Top
Published in: Radiation Oncology 1/2018

Open Access 01-12-2018 | Research

In silico assessment of the dosimetric quality of a novel, automated radiation treatment planning strategy for linac-based radiosurgery of multiple brain metastases and a comparison with robotic methods

Authors: Krzysztof Slosarek, Barbara Bekman, Jacek Wendykier, Aleksandra Grządziel, Antonella Fogliata, Luca Cozzi

Published in: Radiation Oncology | Issue 1/2018

Login to get access

Abstract

Background

To appraise the dosimetric features and the quality of the treatment plan for radiosurgery of multiple brain metastases optimized with a novel automated engine and to compare with plans optimized for robotic-based delivery.

Methods

A set of 15 patients with multiple brain metastases was selected for this in silico study. The technique under investigation is the recently introduced HyperArc. For all patients, three treatment plans were computed and compared: i: a HyperArc; ii: a standard VMAT; iii) a CyberKnife. Dosimetric features were computed for the clinical target volumes as well as for the healthy brain tissue and the organs at risk.

Results

The data showed that the best dose homogeneity was achieved with the VMAT technique. HyperArc allowed to minimize the volume of brain receiving 4Gy (as well as for the mean dose and the volume receiving 12Gy, although not statistically significant). The smallest dose on 1 cm3 volume for all organs at risk is for CK techniques, and the biggest for VMAT (p < 0.05). The Radiation Planning Index coefficient indicates that, there are no significant differences among the techniques investigated, suggesting an equivalence among these.

Conclusion

At treatment planning level, the study demonstrates that the use of HyperArc technique can significantly improve the sparing of the healthy brain while maintaining a full coverage of the target volumes.
Literature
1.
go back to reference Halasz L, Uno H, Hughes M, D’Amico T, Dexter E, Edge S, Hayman J, Niland J, Otterson G, Pisters K, Theriolt R, Weeks J, Punglia R. Comparative effectiveness of stereotactic radiosurgery versus whole brain radiation therapy for patients with brain metastases from breast or non small cell lung cancer. Cancer. 2016;122:2091–100.CrossRefPubMedPubMedCentral Halasz L, Uno H, Hughes M, D’Amico T, Dexter E, Edge S, Hayman J, Niland J, Otterson G, Pisters K, Theriolt R, Weeks J, Punglia R. Comparative effectiveness of stereotactic radiosurgery versus whole brain radiation therapy for patients with brain metastases from breast or non small cell lung cancer. Cancer. 2016;122:2091–100.CrossRefPubMedPubMedCentral
2.
go back to reference Jairam V, Chiang V, Yu J, Knksely J. Role of stereotactic radiosurgery in patients with more than four brain metastases. CNS oncol. 2013;2:181–93.CrossRefPubMed Jairam V, Chiang V, Yu J, Knksely J. Role of stereotactic radiosurgery in patients with more than four brain metastases. CNS oncol. 2013;2:181–93.CrossRefPubMed
3.
go back to reference Elaimy A, Mackay A, Lamoreaux W, Fairbanks R, Demakas J, Cook B, Lee C. Clinical outcomes of stereotactic radiosurgery in the treatment of patients with metastatic brain tumors. World Neurosurg. 2011;75:673–83.CrossRefPubMed Elaimy A, Mackay A, Lamoreaux W, Fairbanks R, Demakas J, Cook B, Lee C. Clinical outcomes of stereotactic radiosurgery in the treatment of patients with metastatic brain tumors. World Neurosurg. 2011;75:673–83.CrossRefPubMed
4.
go back to reference Soliman H, Das S, Larson D, Sahgal A. Stereotactic radiosurgery (SRS) in the modern management of patients with brain metastases. Oncotarget. 2016;7:12318–30. Soliman H, Das S, Larson D, Sahgal A. Stereotactic radiosurgery (SRS) in the modern management of patients with brain metastases. Oncotarget. 2016;7:12318–30.
5.
go back to reference Lam T, Sahgal A, Cahng E, Lo S. Stereotactic radiosurgery for multiple brain metastases. Exp Rev Anticancer Ther. 2014;14:1153–72.CrossRef Lam T, Sahgal A, Cahng E, Lo S. Stereotactic radiosurgery for multiple brain metastases. Exp Rev Anticancer Ther. 2014;14:1153–72.CrossRef
6.
go back to reference Dong P, Lee P, Ruan D, Long T, Romeijn E, Yang Y, et al. 4π non-coplanar liver SBRT: a novel delivery technique. Int J Radiat Oncol Biol Phys. 2013;85:1360–6.CrossRefPubMed Dong P, Lee P, Ruan D, Long T, Romeijn E, Yang Y, et al. 4π non-coplanar liver SBRT: a novel delivery technique. Int J Radiat Oncol Biol Phys. 2013;85:1360–6.CrossRefPubMed
7.
go back to reference Dong P, Lee P, Ruan D, Long T, Romeijn E, Low D, et al. 4π non-coplanar stereotactic body radiation therapy for centrally located or larger lung tumors. Int J Radiat Oncol Biol Phys. 2013;86:407–13.CrossRefPubMed Dong P, Lee P, Ruan D, Long T, Romeijn E, Low D, et al. 4π non-coplanar stereotactic body radiation therapy for centrally located or larger lung tumors. Int J Radiat Oncol Biol Phys. 2013;86:407–13.CrossRefPubMed
8.
go back to reference Nguyen D, Rwigema J, Yu V, Kaprealian T, Kupelian P, Selch M, et al. Feasibility of extreme dose escalation for glioblastoma multiforme using 4π radiotherapy. Radiat Oncol. 2014;9:239.CrossRefPubMedPubMedCentral Nguyen D, Rwigema J, Yu V, Kaprealian T, Kupelian P, Selch M, et al. Feasibility of extreme dose escalation for glioblastoma multiforme using 4π radiotherapy. Radiat Oncol. 2014;9:239.CrossRefPubMedPubMedCentral
9.
go back to reference Dong P, Nguyen D, Ruan D, King C, Long T, Romeijn E, et al. Feasibility of prostate robotic radiation therapy on conventional c-arm linacs. Pract Radiat Oncol. 2014;4:254–60.CrossRefPubMed Dong P, Nguyen D, Ruan D, King C, Long T, Romeijn E, et al. Feasibility of prostate robotic radiation therapy on conventional c-arm linacs. Pract Radiat Oncol. 2014;4:254–60.CrossRefPubMed
10.
go back to reference Woods K, Nguyen D, Tran A, Yu V, Cao M, Niu T, et al. Viability of non-coplanar VMAT for liver SBRT compared with coplanar VMAT and beam orientation optimized 4π IMRT. Adv Radiat Oncol. 2016;1:67–75.CrossRefPubMedPubMedCentral Woods K, Nguyen D, Tran A, Yu V, Cao M, Niu T, et al. Viability of non-coplanar VMAT for liver SBRT compared with coplanar VMAT and beam orientation optimized 4π IMRT. Adv Radiat Oncol. 2016;1:67–75.CrossRefPubMedPubMedCentral
11.
go back to reference Yu V, Tran A, Nguyen D, Cao M, Ruan D, Low D, Sheng K. The development and verification of a highly accurate collision prediction model for automated non-coplanar plan delivery. Med Phys. 2015;42:6457–67.CrossRefPubMedPubMedCentral Yu V, Tran A, Nguyen D, Cao M, Ruan D, Low D, Sheng K. The development and verification of a highly accurate collision prediction model for automated non-coplanar plan delivery. Med Phys. 2015;42:6457–67.CrossRefPubMedPubMedCentral
12.
go back to reference Rwigema J, Nguyen D, Heron D, Chen A, Lee P, Wang P, et al. 4p non-coplanar stereotatic body radiation therapy for head and neck cancer: potential to improve tumor control and late toxicity. Int J Radiat Oncol Biol Phys. 2015;91:401–9.CrossRefPubMed Rwigema J, Nguyen D, Heron D, Chen A, Lee P, Wang P, et al. 4p non-coplanar stereotatic body radiation therapy for head and neck cancer: potential to improve tumor control and late toxicity. Int J Radiat Oncol Biol Phys. 2015;91:401–9.CrossRefPubMed
13.
go back to reference Clark G, Popple R, Prendergast B, Spencer S, Thomas E, Stewart J, Guthrie B, Markert J, Fiveash J. Plan quality and treatment planning techniques for single isocenter cranial radiosurgery with volumetric modulated arc therapy. Prat Radiat Oncol. 2012;2:306–13.CrossRef Clark G, Popple R, Prendergast B, Spencer S, Thomas E, Stewart J, Guthrie B, Markert J, Fiveash J. Plan quality and treatment planning techniques for single isocenter cranial radiosurgery with volumetric modulated arc therapy. Prat Radiat Oncol. 2012;2:306–13.CrossRef
14.
go back to reference Thomas E, Popple R, Wu X, Clark G, Markert J, Guthrie B, Yuan Y, Dobelbower M, Spencer S, Fiveash J. Comparison of plan quality and delivery time between volumetric arc therapy (RapidArc) and Gamma Kinife radiosurgery for multiple cranial metastases. Neurosurgery. 2014;75:409–17.CrossRefPubMedPubMedCentral Thomas E, Popple R, Wu X, Clark G, Markert J, Guthrie B, Yuan Y, Dobelbower M, Spencer S, Fiveash J. Comparison of plan quality and delivery time between volumetric arc therapy (RapidArc) and Gamma Kinife radiosurgery for multiple cranial metastases. Neurosurgery. 2014;75:409–17.CrossRefPubMedPubMedCentral
15.
go back to reference Mayo CS, Ding L, Addesa A, Kadish S, Fitzgerald TJ, Moser R. Initial experience with volumetric IMRT (RapidArc) for intracranial stereotactic radiosurgery. Int J Radiat Oncol Biol Phys. 2010;78:1457–66.CrossRefPubMed Mayo CS, Ding L, Addesa A, Kadish S, Fitzgerald TJ, Moser R. Initial experience with volumetric IMRT (RapidArc) for intracranial stereotactic radiosurgery. Int J Radiat Oncol Biol Phys. 2010;78:1457–66.CrossRefPubMed
16.
go back to reference Macdougall ND, Dean C, Muirhead R. Stereotactic body radiotherapy in prostate cancer: is rapidarc a better solution than cyberknife? Clin Oncol (R Coll Radiol). 2014;26:4–9.CrossRef Macdougall ND, Dean C, Muirhead R. Stereotactic body radiotherapy in prostate cancer: is rapidarc a better solution than cyberknife? Clin Oncol (R Coll Radiol). 2014;26:4–9.CrossRef
17.
go back to reference Lin YW, Lin KH, Ho HW, Lin HM, Lin LC, Lee SP, Chui CS. Treatment plan comparison between stereotactic body radiation therapy techniques for prostate cancer: non-isocentric CyberKnife versus isocentric RapidArc. Phys Med. 2014;30:654–61.CrossRefPubMed Lin YW, Lin KH, Ho HW, Lin HM, Lin LC, Lee SP, Chui CS. Treatment plan comparison between stereotactic body radiation therapy techniques for prostate cancer: non-isocentric CyberKnife versus isocentric RapidArc. Phys Med. 2014;30:654–61.CrossRefPubMed
18.
go back to reference Lin YW, Lin LC, Lin KL. The early result of whole pelvic radiotherapy and stereotactic body radiotherapy boost for high-risk localized prostate cancer. Front Oncol. 2014;4:278.CrossRefPubMedPubMedCentral Lin YW, Lin LC, Lin KL. The early result of whole pelvic radiotherapy and stereotactic body radiotherapy boost for high-risk localized prostate cancer. Front Oncol. 2014;4:278.CrossRefPubMedPubMedCentral
19.
go back to reference Paik EK, Kim MS, Choi CW, Jang WI, Lee SH, Choi SH, Kim KB, Lee DH. Dosimetric comparison of volumetric modulated arc therapy with robotic stereotactic radiation therapy in hepatocellular carcinoma. Radiat Oncol J. 2015;33:233–41.CrossRefPubMedPubMedCentral Paik EK, Kim MS, Choi CW, Jang WI, Lee SH, Choi SH, Kim KB, Lee DH. Dosimetric comparison of volumetric modulated arc therapy with robotic stereotactic radiation therapy in hepatocellular carcinoma. Radiat Oncol J. 2015;33:233–41.CrossRefPubMedPubMedCentral
20.
go back to reference Yang J, Ma L, Wang XS, Xu WX, Cong XH, Xu SP, Ju ZJ, Du L, Cai BN, Yang J. Dosimetric evaluation of 4 different treatment modalities for curative-intent stereotactic body radiation therapy for isolated thoracic spinal metastases. Med Dosim. 2016;41:105–12.CrossRefPubMed Yang J, Ma L, Wang XS, Xu WX, Cong XH, Xu SP, Ju ZJ, Du L, Cai BN, Yang J. Dosimetric evaluation of 4 different treatment modalities for curative-intent stereotactic body radiation therapy for isolated thoracic spinal metastases. Med Dosim. 2016;41:105–12.CrossRefPubMed
21.
go back to reference Seppälä J, Suilamo S, Tenhunen M, Sailas L, Virsunen H, Kaleva E, Keyriläinen J. Dosimetric comparison and evaluation of 4 stereotactic body radiotherapy techniques for the treatment of prostate Cancer. Technol Cancer Res Treat. 2017;16:238–45.CrossRefPubMed Seppälä J, Suilamo S, Tenhunen M, Sailas L, Virsunen H, Kaleva E, Keyriläinen J. Dosimetric comparison and evaluation of 4 stereotactic body radiotherapy techniques for the treatment of prostate Cancer. Technol Cancer Res Treat. 2017;16:238–45.CrossRefPubMed
22.
go back to reference Nalichowski A, Kaufman I, Gallo J, Bossenberger T, Solberg T, Ramirez E, Yan Y, Fredrick J, Bichay T, Mayville A, Burmeister J. Single fraction radiosurgery/stereotactic body radiation therapy (SBRT) for spine metastasis: a dosimetric comparison of multiple delivery platforms. J Appl Clin Med Phys. 2017;18:164–9.PubMed Nalichowski A, Kaufman I, Gallo J, Bossenberger T, Solberg T, Ramirez E, Yan Y, Fredrick J, Bichay T, Mayville A, Burmeister J. Single fraction radiosurgery/stereotactic body radiation therapy (SBRT) for spine metastasis: a dosimetric comparison of multiple delivery platforms. J Appl Clin Med Phys. 2017;18:164–9.PubMed
23.
go back to reference Bae SH, Kim MS, Jang WI, Kim KB, Cho KH, Kim WC, Lee CY, Kim ES, Choi CW, Chang AR, Jo S, Kim JY. Quality assurance for a multicenter phase II study of stereotactic ablative radiotherapy for hepatocellular carcinoma ≤5 cm: a planning dummy run. Jpn J Clin Oncol. 2017;47:535–42.CrossRefPubMed Bae SH, Kim MS, Jang WI, Kim KB, Cho KH, Kim WC, Lee CY, Kim ES, Choi CW, Chang AR, Jo S, Kim JY. Quality assurance for a multicenter phase II study of stereotactic ablative radiotherapy for hepatocellular carcinoma ≤5 cm: a planning dummy run. Jpn J Clin Oncol. 2017;47:535–42.CrossRefPubMed
24.
go back to reference Liu H, Andrews D, Evans J, Werner-Wasik M, Yu Y, Dicker A, Shi W. Plan quality and treatment efficiency for radiosurgery to multiple brain metastases: non coplanar RapidArc vs. Gamma knife. Front Oncol. 2016;6:26.PubMedPubMedCentral Liu H, Andrews D, Evans J, Werner-Wasik M, Yu Y, Dicker A, Shi W. Plan quality and treatment efficiency for radiosurgery to multiple brain metastases: non coplanar RapidArc vs. Gamma knife. Front Oncol. 2016;6:26.PubMedPubMedCentral
25.
go back to reference Paddick I. A simple scoring ratio to index the conformity of radiosurgical treatment plans. J Neurosurg. 2000;94:219–22. Paddick I. A simple scoring ratio to index the conformity of radiosurgical treatment plans. J Neurosurg. 2000;94:219–22.
26.
go back to reference Paddick I, Lippitz B. A simple dose gradient measurement tool to complement the conformity index. J Neurosurg. 2006;105:194–201.PubMed Paddick I, Lippitz B. A simple dose gradient measurement tool to complement the conformity index. J Neurosurg. 2006;105:194–201.PubMed
27.
go back to reference Slosarek K, Grzadziel A, Szlag M, Bystrzycka J. Radiation planning index for dose distribution evaluation in stereotactic radiotherapy. Rep Pract Oncol Radiother. 2008;13:182–6.CrossRef Slosarek K, Grzadziel A, Szlag M, Bystrzycka J. Radiation planning index for dose distribution evaluation in stereotactic radiotherapy. Rep Pract Oncol Radiother. 2008;13:182–6.CrossRef
28.
go back to reference Ślosarek K, Kopczyńska J, Osewski W. Dose specification in external beam radiotherapy for CyberKnife and VMAT techniques applied to a case of prostate cancer. Nowotwory J Oncol. 2016;66:375–80.CrossRef Ślosarek K, Kopczyńska J, Osewski W. Dose specification in external beam radiotherapy for CyberKnife and VMAT techniques applied to a case of prostate cancer. Nowotwory J Oncol. 2016;66:375–80.CrossRef
Metadata
Title
In silico assessment of the dosimetric quality of a novel, automated radiation treatment planning strategy for linac-based radiosurgery of multiple brain metastases and a comparison with robotic methods
Authors
Krzysztof Slosarek
Barbara Bekman
Jacek Wendykier
Aleksandra Grządziel
Antonella Fogliata
Luca Cozzi
Publication date
01-12-2018
Publisher
BioMed Central
Published in
Radiation Oncology / Issue 1/2018
Electronic ISSN: 1748-717X
DOI
https://doi.org/10.1186/s13014-018-0997-y

Other articles of this Issue 1/2018

Radiation Oncology 1/2018 Go to the issue