Skip to main content
Top
Published in: Journal of Occupational Medicine and Toxicology 1/2019

Open Access 01-12-2019 | Methodology

Survival of Staphylococcus aureus on the outer shell of fire fighter turnout gear after sanitation in a commercial washer/extractor

Authors: Daniel Farcas, Francoise M. Blachere, Michael L. Kashon, Deborah Sbarra, Diane Schwegler-Berry, Jeffrey O. Stull, John D. Noti

Published in: Journal of Occupational Medicine and Toxicology | Issue 1/2019

Login to get access

Abstract

Background

Methicillin-resistant Staphylococcus aureus contamination on surfaces including turnout gear had been found throughout a number of fire stations. As such, the outer shell barrier of turnout gear jackets may be an indirect transmission source and proper disinfection is essential to reduce the risk of exposure to fire fighters. Cleaning practices vary considerably among fire stations, and a method to assess disinfection of gear washed in commercial washer/extractors is needed.

Methods

Swatches (1 in. ×  1.5 in.) of the outer shell fabrics, Gemini™, Advance™, and Pioneer™, of turnout gear were inoculated with S. aureus, and washed with an Environmental Protection Agency-registered sanitizer commonly used to wash turnout gear. To initially assess the sanitizer, inoculated swatches were washed in small tubes according to the American Society for Testing Materials E2274 Protocol for evaluating laundry sanitizers. Inoculated swatches were also pinned to turnout gear jackets and washed in a Milnor commercial washer/extractor. Viable S. aureus that remained attached to fabric swatches after washing were recovered and quantified. Scanning Electron Microscopy was used to characterize the stages of S. aureus biofilm formation on the swatches that can result in resistance to disinfection.

Results

Disinfection in small tubes for only 10 s reduced the viability of S. aureus on Gemini™, Advance™, and Pioneer™ by 73, 99, and 100%, respectively. In contrast, disinfection of S. aureus-contaminated Gemini™ swatches pinned to turnout gear and washed in the washer/extractor was 99.7% effective. Scanning Electron Microscopy showed that biofilm formation begins as early as 5 h after attachment of S. aureus.

Conclusion

This sanitizer and, likely, others containing the anti-microbial agent didecyl dimethyl ammonium chloride, is an effective disinfectant of S. aureus. Inclusion of contaminated outer shell swatches in the wash cycle affords a simple and quantitative method to assess sanitization of gear by commercial gear cleaning facilities. This methodology can be extended to assess for other bacterial contaminants. Sanitizer-resistant strains will continue to pose problems, and biofilm formation may affect the cleanliness of the washed turnout gear. Our methodology for assessing effectiveness of disinfection may help reduce the occupational exposure to fire fighters from bacterial contaminants.
Literature
1.
go back to reference Thammavongsa V, Kim HK, Missiakas D, Schneewind O. Staphylococcal manipulation of host immune responses. Nat Rev Microbiol. 2015;13(9):529–43.CrossRef Thammavongsa V, Kim HK, Missiakas D, Schneewind O. Staphylococcal manipulation of host immune responses. Nat Rev Microbiol. 2015;13(9):529–43.CrossRef
2.
go back to reference Cosgrove SE, Sakoulas G, Perencevich EN, Schwaber MJ, Karchmer AW, Carmeli Y. Comparison of mortality associated with methicilin-resistanct and methicillin-susceptible Staphylococcus aureus bacteremia: a meta-analysis. CID. 2003;36:53–9.CrossRef Cosgrove SE, Sakoulas G, Perencevich EN, Schwaber MJ, Karchmer AW, Carmeli Y. Comparison of mortality associated with methicilin-resistanct and methicillin-susceptible Staphylococcus aureus bacteremia: a meta-analysis. CID. 2003;36:53–9.CrossRef
4.
go back to reference Williams D. Danger in the station: drug resistant infections. Fire Eng. 2006;159:69–74. Williams D. Danger in the station: drug resistant infections. Fire Eng. 2006;159:69–74.
5.
go back to reference Sexton JD, Reynolds KA. Exposure of emergency medical responders to methicillin-resistant Staphylococcus aureus. Am J Infect Control. 2010;38:368–73.CrossRef Sexton JD, Reynolds KA. Exposure of emergency medical responders to methicillin-resistant Staphylococcus aureus. Am J Infect Control. 2010;38:368–73.CrossRef
6.
go back to reference Roberts MC, Soge OO, No D, Beck NK, Meschke JS. Isolation and characterization of methicillin-resistant Staphylococcus aureus from fire stations in two northwest fire districts. Am J Infect Control. 2011;39:382–9.CrossRef Roberts MC, Soge OO, No D, Beck NK, Meschke JS. Isolation and characterization of methicillin-resistant Staphylococcus aureus from fire stations in two northwest fire districts. Am J Infect Control. 2011;39:382–9.CrossRef
7.
go back to reference Roberts MC, No DB. Environment surface sampling in 33 Washington state fire stations for methicillin-resistant and methicillin-susceptible Staphylococcus aureus. Am J Infect Control. 2014;42(6):591–6.CrossRef Roberts MC, No DB. Environment surface sampling in 33 Washington state fire stations for methicillin-resistant and methicillin-susceptible Staphylococcus aureus. Am J Infect Control. 2014;42(6):591–6.CrossRef
8.
go back to reference Neely AN, Maley MP. Survival of enterococci and staphylococci on hospital fabrics and plastic. J Clin Microbiol. 2000;38(2):724–6.PubMedPubMedCentral Neely AN, Maley MP. Survival of enterococci and staphylococci on hospital fabrics and plastic. J Clin Microbiol. 2000;38(2):724–6.PubMedPubMedCentral
9.
go back to reference Kramer A, Schwebke I, Kampf G. How long do nosocomial pathogens persist on inanimate surfaces? A systematic review. BMC Infect Dis. 2006;6:130.CrossRef Kramer A, Schwebke I, Kampf G. How long do nosocomial pathogens persist on inanimate surfaces? A systematic review. BMC Infect Dis. 2006;6:130.CrossRef
10.
go back to reference Craine K, Glanz B. Working to death: the hidden dangers of infectious diseases. JIAFF. 2009;92(2):16–7. Craine K, Glanz B. Working to death: the hidden dangers of infectious diseases. JIAFF. 2009;92(2):16–7.
11.
go back to reference NFPA. 1851 Standard on selection, care, and maintenance of protective ensembles for structural fire fighting and proximity fire fighting; 2014. p. 11. NFPA. 1851 Standard on selection, care, and maintenance of protective ensembles for structural fire fighting and proximity fire fighting; 2014. p. 11.
12.
go back to reference ASTM E2274-09: standard test method for evaluation of laundry sanitizers and disinfectants. 2016. ASTM E2274-09: standard test method for evaluation of laundry sanitizers and disinfectants. 2016.
13.
go back to reference ASTM E1054-08. Standard test methods for evaluation of inactivators of antimicrobial agents. 2013. ASTM E1054-08. Standard test methods for evaluation of inactivators of antimicrobial agents. 2013.
14.
go back to reference Brown EA, Benson HJ. In: Smith AEBHR, editor. Benson’s microbiological applications. 9th ed. New York: McGraw Hill Publication; 2004. Brown EA, Benson HJ. In: Smith AEBHR, editor. Benson’s microbiological applications. 9th ed. New York: McGraw Hill Publication; 2004.
15.
go back to reference Engley FB Jr, Dey BP. A universal neutralizing medium for antimicrobial chemicals. In: Chemical Specialties Manufacturers Association Proceedings 56th Mid-Year Meeting; 1970. p. 106–10. Engley FB Jr, Dey BP. A universal neutralizing medium for antimicrobial chemicals. In: Chemical Specialties Manufacturers Association Proceedings 56th Mid-Year Meeting; 1970. p. 106–10.
16.
go back to reference Blachere FM, Cao G, Lindsley WG, Noti JD, Beezhold DH. Enhanced detection of infectious airborne influenza virus. J Virol Methods. 2011;176:120–4.CrossRef Blachere FM, Cao G, Lindsley WG, Noti JD, Beezhold DH. Enhanced detection of infectious airborne influenza virus. J Virol Methods. 2011;176:120–4.CrossRef
17.
go back to reference Jansen AC, Boucher CE, Coetsee E, Kock JFL, Wyk PWJ, Swart HC, et al. The influence of didecyldimethylammonium chloride on the morphology and elemental composition of Staphylococcus aureus as determined by NanoSAM. Sci Res Essays. 2013;8(3):152–60. Jansen AC, Boucher CE, Coetsee E, Kock JFL, Wyk PWJ, Swart HC, et al. The influence of didecyldimethylammonium chloride on the morphology and elemental composition of Staphylococcus aureus as determined by NanoSAM. Sci Res Essays. 2013;8(3):152–60.
18.
go back to reference Petrocci AN, Clark P. Proposed test method for antimicrobial laundry additives. J Assoc Off Anal Chem. 1969;52:836–42. Petrocci AN, Clark P. Proposed test method for antimicrobial laundry additives. J Assoc Off Anal Chem. 1969;52:836–42.
19.
go back to reference Washam CJ, Sandine WE, Elliker PR. A strain of Pseudomonas aeruginosa resistant to a quaternary ammonium compound. J Milk Food Technol. 1976;39:101–6.CrossRef Washam CJ, Sandine WE, Elliker PR. A strain of Pseudomonas aeruginosa resistant to a quaternary ammonium compound. J Milk Food Technol. 1976;39:101–6.CrossRef
20.
go back to reference Dunne WM Jr. Bacterial adhesion: seen any good biofilms lately? Clin Microbiol Rev. 2002;15(2):155–66.CrossRef Dunne WM Jr. Bacterial adhesion: seen any good biofilms lately? Clin Microbiol Rev. 2002;15(2):155–66.CrossRef
22.
go back to reference Otto M. Staphyloccal infections: mechanisms of biofilm maturation and detachment as critical determinants of pathogenicity. Annu Rev Med. 2013;64:175–88.CrossRef Otto M. Staphyloccal infections: mechanisms of biofilm maturation and detachment as critical determinants of pathogenicity. Annu Rev Med. 2013;64:175–88.CrossRef
23.
go back to reference Lee K, Yoon SS. Pseudomonas aeruginosa biofilm, a programmed bacterial life for fitness. J Microbiol Biotechnol. 2017;27(6):1053–64.PubMed Lee K, Yoon SS. Pseudomonas aeruginosa biofilm, a programmed bacterial life for fitness. J Microbiol Biotechnol. 2017;27(6):1053–64.PubMed
24.
go back to reference Harmsen M, Yang L, Pamp SJ, Tolker-Nielsen T. An update on Pseudomonas aeruginosa biofilm formation, tolerance, and dispersal. FEMS Immunol Med Microbiol. 2010;59:253–68.CrossRef Harmsen M, Yang L, Pamp SJ, Tolker-Nielsen T. An update on Pseudomonas aeruginosa biofilm formation, tolerance, and dispersal. FEMS Immunol Med Microbiol. 2010;59:253–68.CrossRef
25.
go back to reference Lister JL, Horswill AR. Staphylococcus aereus biofils: recent developments in biofilm dispersal. Front Cell Infect Microbiol. 2014;4(article 8):1–9. Lister JL, Horswill AR. Staphylococcus aereus biofils: recent developments in biofilm dispersal. Front Cell Infect Microbiol. 2014;4(article 8):1–9.
26.
go back to reference Mann EE, Wozniak DJ. Pseudomonas biofilm matrix composition and niche biology. FEMS Microbiol Rev. 2012;36:893–916.CrossRef Mann EE, Wozniak DJ. Pseudomonas biofilm matrix composition and niche biology. FEMS Microbiol Rev. 2012;36:893–916.CrossRef
Metadata
Title
Survival of Staphylococcus aureus on the outer shell of fire fighter turnout gear after sanitation in a commercial washer/extractor
Authors
Daniel Farcas
Francoise M. Blachere
Michael L. Kashon
Deborah Sbarra
Diane Schwegler-Berry
Jeffrey O. Stull
John D. Noti
Publication date
01-12-2019
Publisher
BioMed Central
Published in
Journal of Occupational Medicine and Toxicology / Issue 1/2019
Electronic ISSN: 1745-6673
DOI
https://doi.org/10.1186/s12995-019-0230-4

Other articles of this Issue 1/2019

Journal of Occupational Medicine and Toxicology 1/2019 Go to the issue