Skip to main content
Top
Published in: Journal of NeuroEngineering and Rehabilitation 1/2017

Open Access 01-12-2017 | Research

Physical interface dynamics alter how robotic exosuits augment human movement: implications for optimizing wearable assistive devices

Authors: Matthew B. Yandell, Brendan T. Quinlivan, Dmitry Popov, Conor Walsh, Karl E. Zelik

Published in: Journal of NeuroEngineering and Rehabilitation | Issue 1/2017

Login to get access

Abstract

Background

Wearable assistive devices have demonstrated the potential to improve mobility outcomes for individuals with disabilities, and to augment healthy human performance; however, these benefits depend on how effectively power is transmitted from the device to the human user. Quantifying and understanding this power transmission is challenging due to complex human-device interface dynamics that occur as biological tissues and physical interface materials deform and displace under load, absorbing and returning power.

Methods

Here we introduce a new methodology for quickly estimating interface power dynamics during movement tasks using common motion capture and force measurements, and then apply this method to quantify how a soft robotic ankle exosuit interacts with and transfers power to the human body during walking. We partition exosuit end-effector power (i.e., power output from the device) into power that augments ankle plantarflexion (termed augmentation power) vs. power that goes into deformation and motion of interface materials and underlying soft tissues (termed interface power).

Results

We provide empirical evidence of how human-exosuit interfaces absorb and return energy, reshaping exosuit-to-human power flow and resulting in three key consequences: (i) During exosuit loading (as applied forces increased), about 55% of exosuit end-effector power was absorbed into the interfaces. (ii) However, during subsequent exosuit unloading (as applied forces decreased) most of the absorbed interface power was returned viscoelastically. Consequently, the majority (about 75%) of exosuit end-effector work over each stride contributed to augmenting ankle plantarflexion. (iii) Ankle augmentation power (and work) was delayed relative to exosuit end-effector power, due to these interface energy absorption and return dynamics.

Conclusions

Our findings elucidate the complexities of human-exosuit interface dynamics during transmission of power from assistive devices to the human body, and provide insight into improving the design and control of wearable robots. We conclude that in order to optimize the performance of wearable assistive devices it is important, throughout design and evaluation phases, to account for human-device interface dynamics that affect power transmission and thus human augmentation benefits.
Appendix
Available only for authorised users
Literature
1.
go back to reference Bae J, De Rossi SMM, O'Donnell K, Hendron KL, Awad LN, Dos Santos TRT, De Araujo VL, Ding Y, Holt KG, Ellis TD, Walsh CJ. A soft exosuit for patients with stroke: Feasibility study with a mobile off-board actuation unit. In: 2015 IEEE International Conference on Rehabilitation Robotics (ICORR). 2015. p. 131–38. Bae J, De Rossi SMM, O'Donnell K, Hendron KL, Awad LN, Dos Santos TRT, De Araujo VL, Ding Y, Holt KG, Ellis TD, Walsh CJ.  A soft exosuit for patients with stroke: Feasibility study with a mobile off-board actuation unit. In: 2015 IEEE International Conference on Rehabilitation Robotics (ICORR). 2015. p. 131–38.
2.
go back to reference Farris RJ, Quintero HA, Murray SA, Ha KH, Hartigan C, Goldfarb M. A Preliminary Assessment of Legged Mobility Provided by a Lower Limb Exoskeleton for Persons With Paraplegia. IEEE Trans Neural Syst Rehabil Eng. 2014;22:482–90.CrossRefPubMed Farris RJ, Quintero HA, Murray SA, Ha KH, Hartigan C, Goldfarb M. A Preliminary Assessment of Legged Mobility Provided by a Lower Limb Exoskeleton for Persons With Paraplegia. IEEE Trans Neural Syst Rehabil Eng. 2014;22:482–90.CrossRefPubMed
3.
go back to reference Dollar AM, Herr H. Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art. IEEE Trans Robot. 2008;24:144–58.CrossRef Dollar AM, Herr H. Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art. IEEE Trans Robot. 2008;24:144–58.CrossRef
4.
go back to reference Panizzolo FA, Galiana I, Asbeck AT, Siviy C, Schmidt K, Holt KG, et al. A biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking. J NeuroEngineering Rehabil. 2016;13:43.CrossRef Panizzolo FA, Galiana I, Asbeck AT, Siviy C, Schmidt K, Holt KG, et al. A biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking. J NeuroEngineering Rehabil. 2016;13:43.CrossRef
6.
go back to reference Quinlivan BT, Lee S, Malcolm P, Rossi DM, Grimmer M, Siviy C, et al. Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit. Sci Robot. 2017;2:eaah4416.CrossRef Quinlivan BT, Lee S, Malcolm P, Rossi DM, Grimmer M, Siviy C, et al. Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit. Sci Robot. 2017;2:eaah4416.CrossRef
7.
go back to reference Young A, Ferris D. State-of-the-art and Future Directions for Robotic Lower Limb Exoskeletons. IEEE Trans Neural Syst Rehabil Eng. 2016;PP:1–1 Young A, Ferris D. State-of-the-art and Future Directions for Robotic Lower Limb Exoskeletons. IEEE Trans Neural Syst Rehabil Eng. 2016;PP:1–1
8.
go back to reference Herr H. Exoskeletons and orthoses: classification, design challenges and future directions. J NeuroEngineering Rehabil. 2009;6:21.CrossRef Herr H. Exoskeletons and orthoses: classification, design challenges and future directions. J NeuroEngineering Rehabil. 2009;6:21.CrossRef
9.
go back to reference Cherry M, Kota S, Young A, Ferris D. Running With an Elastic Lower Limb Exoskeleton. J Appl Biomech. 2015;32:269–77. Cherry M, Kota S, Young A, Ferris D. Running With an Elastic Lower Limb Exoskeleton. J Appl Biomech. 2015;32:269–77.
10.
go back to reference Asbeck AT, Dyer RJ, Larusson AF, Walsh CJ. Biologically-inspired soft exosuit. In: 2013 IEEE International Conference on Rehabilitation Robotics (ICORR). 2013. p. 1–8. Asbeck AT, Dyer RJ, Larusson AF, Walsh CJ. Biologically-inspired soft exosuit. In: 2013 IEEE International Conference on Rehabilitation Robotics (ICORR). 2013. p. 1–8.
11.
go back to reference Asbeck AT, Rossi SMMD, Holt KG, Walsh CJ. A biologically inspired soft exosuit for walking assistance. Int J Robot Res. 2015;34;744–62. Asbeck AT, Rossi SMMD, Holt KG, Walsh CJ. A biologically inspired soft exosuit for walking assistance. Int J Robot Res. 2015;34;744–62.
12.
go back to reference Zanotto D, Akiyama Y, Stegall P, Agrawal SK. Knee Joint Misalignment in Exoskeletons for the Lower Extremities: Effects on User #x0027;s Gait. IEEE Trans Robot. 2015;31:978–87.CrossRef Zanotto D, Akiyama Y, Stegall P, Agrawal SK. Knee Joint Misalignment in Exoskeletons for the Lower Extremities: Effects on User #x0027;s Gait. IEEE Trans Robot. 2015;31:978–87.CrossRef
14.
go back to reference Schiele A, van der Helm FCT. Kinematic Design to Improve Ergonomics in Human Machine Interaction. IEEE Trans Neural Syst Rehabil Eng. 2006;14:456–69.CrossRefPubMed Schiele A, van der Helm FCT. Kinematic Design to Improve Ergonomics in Human Machine Interaction. IEEE Trans Neural Syst Rehabil Eng. 2006;14:456–69.CrossRefPubMed
15.
go back to reference Mooney LM, Rouse EJ, Herr HM. Autonomous exoskeleton reduces metabolic cost of human walking during load carriage. J NeuroEngineering Rehabil. 2014;11:80.CrossRef Mooney LM, Rouse EJ, Herr HM. Autonomous exoskeleton reduces metabolic cost of human walking during load carriage. J NeuroEngineering Rehabil. 2014;11:80.CrossRef
16.
go back to reference De Rossi SMM, Vitiello N, Lenzi T, Ronsse R, Koopman B, Persichetti A, et al. Sensing Pressure Distribution on a Lower-Limb Exoskeleton Physical Human-Machine Interface. Sensors. 2010;11:207–27.CrossRefPubMedPubMedCentral De Rossi SMM, Vitiello N, Lenzi T, Ronsse R, Koopman B, Persichetti A, et al. Sensing Pressure Distribution on a Lower-Limb Exoskeleton Physical Human-Machine Interface. Sensors. 2010;11:207–27.CrossRefPubMedPubMedCentral
17.
go back to reference Quinlivan B, Asbeck A, Wagner D, Ranzani T, Russo S, Walsh C. Force Transfer Characterization of a Soft Exosuit for Gait Assistance. In ASME 2015 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. 2015. doi:10.1115/DETC2015-47871. Quinlivan B, Asbeck A, Wagner D, Ranzani T, Russo S, Walsh C. Force Transfer Characterization of a Soft Exosuit for Gait Assistance. In ASME 2015 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. 2015. doi:10.​1115/​DETC2015-47871.
18.
go back to reference Lee S, Crea S, Malcolm P, Galiana I, Asbeck A, Walsh C. Controlling negative and positive power at the ankle with a soft exosuit. In: 2016 IEEE International Conference on Robotics and Automation (ICRA). 2016. p. 3509–15. Lee S, Crea S, Malcolm P, Galiana I, Asbeck A, Walsh C. Controlling negative and positive power at the ankle with a soft exosuit. In: 2016 IEEE International Conference on Robotics and Automation (ICRA). 2016. p. 3509–15.
19.
go back to reference Braune W, Fischer O. Der Gang des Menschen: I. Theil: Versuche am unbelasteten und belasteten Menschen. B.S. Hirzel. 1895. Braune W, Fischer O. Der Gang des Menschen: I. Theil: Versuche am unbelasteten und belasteten Menschen. B.S. Hirzel. 1895.
20.
go back to reference Elftman H. The function of muscles in locomotion. Am J Physiol -- Leg Content. 1939;125:357. Elftman H. The function of muscles in locomotion. Am J Physiol -- Leg Content. 1939;125:357.
21.
go back to reference Zelik KE, Takahashi KZ, Sawicki GS. Six degree-of-freedom analysis of hip, knee, ankle and foot provides updated understanding of biomechanical work during human walking. J Exp Biol. 2015;218:876–86.CrossRefPubMed Zelik KE, Takahashi KZ, Sawicki GS. Six degree-of-freedom analysis of hip, knee, ankle and foot provides updated understanding of biomechanical work during human walking. J Exp Biol. 2015;218:876–86.CrossRefPubMed
22.
go back to reference Jackson RW, Collins SH. An experimental comparison of the relative benefits of work and torque assistance in ankle exoskeletons. J Appl Physiol. 2015;119:541–57.CrossRefPubMed Jackson RW, Collins SH. An experimental comparison of the relative benefits of work and torque assistance in ankle exoskeletons. J Appl Physiol. 2015;119:541–57.CrossRefPubMed
23.
go back to reference Grabowski AM, Herr HM. Leg exoskeleton reduces the metabolic cost of human hopping. J Appl Physiol. 2009;107:670–8.CrossRefPubMed Grabowski AM, Herr HM. Leg exoskeleton reduces the metabolic cost of human hopping. J Appl Physiol. 2009;107:670–8.CrossRefPubMed
25.
go back to reference Farris DJ, Sawicki GS. Linking the mechanics and energetics of hopping with elastic ankle exoskeletons. J Appl Physiol. 2012;113:1862–72.CrossRefPubMed Farris DJ, Sawicki GS. Linking the mechanics and energetics of hopping with elastic ankle exoskeletons. J Appl Physiol. 2012;113:1862–72.CrossRefPubMed
26.
go back to reference Galle S, Derave W, Bossuyt F, Calders P, Malcolm P, De Clercq D. Exoskeleton plantarflexion assistance for elderly. Gait Posture. 2017;52:183–8.CrossRefPubMed Galle S, Derave W, Bossuyt F, Calders P, Malcolm P, De Clercq D. Exoskeleton plantarflexion assistance for elderly. Gait Posture. 2017;52:183–8.CrossRefPubMed
27.
go back to reference Malcolm P, Quesada RE, Caputo JM, Collins SH. The influence of push-off timing in a robotic ankle-foot prosthesis on the energetics and mechanics of walking. J NeuroEngineering Rehabil. 2015;12:21.CrossRef Malcolm P, Quesada RE, Caputo JM, Collins SH. The influence of push-off timing in a robotic ankle-foot prosthesis on the energetics and mechanics of walking. J NeuroEngineering Rehabil. 2015;12:21.CrossRef
28.
go back to reference Malcolm P, Derave W, Galle S, Clercq DD. A Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human Walking. PLoS One. 2013;8:e56137.CrossRefPubMedPubMedCentral Malcolm P, Derave W, Galle S, Clercq DD. A Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human Walking. PLoS One. 2013;8:e56137.CrossRefPubMedPubMedCentral
29.
go back to reference Ding Y, Galiana I, Asbeck A, Quinlivan B, Rossi SMMD, Walsh C. Multi-joint actuation platform for lower extremity soft exosuits. In: 2014 IEEE International Conference on Robotics and Automation (ICRA). 2014. p. 1327–34.CrossRef Ding Y, Galiana I, Asbeck A, Quinlivan B, Rossi SMMD, Walsh C. Multi-joint actuation platform for lower extremity soft exosuits. In: 2014 IEEE International Conference on Robotics and Automation (ICRA). 2014. p. 1327–34.CrossRef
30.
go back to reference Riemer R, Hsiao-Wecksler ET, Zhang X. Uncertainties in inverse dynamics solutions: A comprehensive analysis and an application to gait. Gait Posture. 2008;27:578–88.CrossRefPubMed Riemer R, Hsiao-Wecksler ET, Zhang X. Uncertainties in inverse dynamics solutions: A comprehensive analysis and an application to gait. Gait Posture. 2008;27:578–88.CrossRefPubMed
Metadata
Title
Physical interface dynamics alter how robotic exosuits augment human movement: implications for optimizing wearable assistive devices
Authors
Matthew B. Yandell
Brendan T. Quinlivan
Dmitry Popov
Conor Walsh
Karl E. Zelik
Publication date
01-12-2017
Publisher
BioMed Central
Published in
Journal of NeuroEngineering and Rehabilitation / Issue 1/2017
Electronic ISSN: 1743-0003
DOI
https://doi.org/10.1186/s12984-017-0247-9

Other articles of this Issue 1/2017

Journal of NeuroEngineering and Rehabilitation 1/2017 Go to the issue