Skip to main content
Top
Published in: Reproductive Biology and Endocrinology 1/2015

Open Access 01-12-2015 | Research

Absolute position versus relative position in embryo transfer: a randomized controlled trial

Authors: Hwang Kwon, Dong-Hee Choi, Eun-Kyung Kim

Published in: Reproductive Biology and Endocrinology | Issue 1/2015

Login to get access

Abstract

Background

Meta-analysis revealed that embryo placement 20 mm from the fundal endometrial surface resulted in higher pregnancy rate, ongoing pregnancy rate, and live birth rate compared with placement 10 mm from the fundal endometrial surface. Pregnancy and implantation rates according to relative position were higher when the catheter tip was positioned close to the middle of the endometrial cavity. The aim of the current study is to evaluate differences in implantation and pregnancy rates if the site of embryo transfer is 2 cm distance from the fundal endometrium (DFE) compared to the midpoint of the endometrial cavity length (ECL).

Methods

Patients were randomized to one of two groups: in group A (n = 98, 98 IVF-ET cycles), the embryo transfer catheter tip was positioned 2 cm DFE, while that in group B (n = 97, 97 IVF-ET cycles) was positioned at the midpoint of the ECL. We compared pregnancy outcomes of implantation rate, chemical pregnancy rate, clinical pregnancy rate, ongoing pregnancy rate, ectopic pregnancy rate, and miscarriage rate in the two groups.

Results

Analysis of implantation rate (19.5 ± 27.7 vs. 21.7 ± 32.6; p = 0.6), chemical pregnancy rate (51 % vs. 50.5 %; p = 0.94), clinical pregnancy rate (35.7 % vs. 38.1 %; p = 0.73), ongoing pregnancy rate (31.6 % vs. 30.9 %; p = 0.92), ectopic pregnancy rate (8.6 % vs. 2.7 %; p = 0.35), and miscarriage rate (11.4 % vs. 16.2 %; 0.74) revealed comparable results for both groups.

Conclusions

Implantation and pregnancy rates were not influenced by the site of the ET catheter tip being 2 cm DFE compared to at the midpoint of the ECL.

Trial Registration

Literature
1.
go back to reference Eskandar MA, Abou-Setta AM, El-Amin M, Almushait MA, Sobande AA. Removal of cervical mucus prior to embryo transfer improves pregnancy rates in women undergoing assisted reproduction. Reprod Biomed Online. 2007;14:308–13.PubMedCrossRef Eskandar MA, Abou-Setta AM, El-Amin M, Almushait MA, Sobande AA. Removal of cervical mucus prior to embryo transfer improves pregnancy rates in women undergoing assisted reproduction. Reprod Biomed Online. 2007;14:308–13.PubMedCrossRef
2.
go back to reference Visschers BA, Bots RS, Peeters MF, Mol BW, van Dessel HJ. Removal of cervical mucus: effect on pregnancy rates in IVF/ICSI. Reprod Biomed Online. 2007;15:310–5.PubMedCrossRef Visschers BA, Bots RS, Peeters MF, Mol BW, van Dessel HJ. Removal of cervical mucus: effect on pregnancy rates in IVF/ICSI. Reprod Biomed Online. 2007;15:310–5.PubMedCrossRef
3.
go back to reference Strickler RC, Christianson C, Crane JP, Curato A, Knight AB, Yang V. Ultrasound guidance for human embryo transfer. Fertil Steril. 1985;43:54–61.PubMed Strickler RC, Christianson C, Crane JP, Curato A, Knight AB, Yang V. Ultrasound guidance for human embryo transfer. Fertil Steril. 1985;43:54–61.PubMed
4.
go back to reference García-Velasco JA, Isaza V, Martinez-Salazar J, Landazábal A, Requena A, Remohí J, et al. Transabdominal ultrasound-guided embryo transfer does not increase pregnancy rates in oocyte recipients. Fertil Steril. 2002;78:534–9.PubMedCrossRef García-Velasco JA, Isaza V, Martinez-Salazar J, Landazábal A, Requena A, Remohí J, et al. Transabdominal ultrasound-guided embryo transfer does not increase pregnancy rates in oocyte recipients. Fertil Steril. 2002;78:534–9.PubMedCrossRef
5.
go back to reference Buckett WM. A meta-analysis of ultrasound-guided versus clinical touch embryo transfer. Fertil Steril. 2003;80:1037–41.PubMedCrossRef Buckett WM. A meta-analysis of ultrasound-guided versus clinical touch embryo transfer. Fertil Steril. 2003;80:1037–41.PubMedCrossRef
6.
go back to reference Abou-Setta AM, Mansour RT, Al-Inany HG, Aboulghar MM, Aboulghar MA, Serour GI. Among women undergoing embryo transfer, is the probability of pregnancy and live birth improved with ultrasound guidance over clinical touch alone? A systemic review and meta-analysis of prospective randomized trials. Fertil Steril. 2007;88:333–41.PubMedCrossRef Abou-Setta AM, Mansour RT, Al-Inany HG, Aboulghar MM, Aboulghar MA, Serour GI. Among women undergoing embryo transfer, is the probability of pregnancy and live birth improved with ultrasound guidance over clinical touch alone? A systemic review and meta-analysis of prospective randomized trials. Fertil Steril. 2007;88:333–41.PubMedCrossRef
7.
go back to reference Abou-Setta AM, Al-Inany HG, Mansour RT, Serour GI, Aboulghar MA. Soft versus firm embryo transfer catheters for assisted reproduction: a systematic review and meta-analysis. Hum Reprod. 2005;20:3114–21.PubMedCrossRef Abou-Setta AM, Al-Inany HG, Mansour RT, Serour GI, Aboulghar MA. Soft versus firm embryo transfer catheters for assisted reproduction: a systematic review and meta-analysis. Hum Reprod. 2005;20:3114–21.PubMedCrossRef
8.
go back to reference Buckett WM. A review and meta-analysis of prospective trials comparing different catheters used for embryo transfer. Fertil Steril. 2006;85:728–34.PubMedCrossRef Buckett WM. A review and meta-analysis of prospective trials comparing different catheters used for embryo transfer. Fertil Steril. 2006;85:728–34.PubMedCrossRef
9.
go back to reference al-Shawaf T, Dave R, Harper J, Linehan D, Riley P, Craft I. Transfer of embryos into the uterus: how much do technical factors affect pregnancy rates? J Assist Reprod Genet. 1993;10:31–6.PubMedCrossRef al-Shawaf T, Dave R, Harper J, Linehan D, Riley P, Craft I. Transfer of embryos into the uterus: how much do technical factors affect pregnancy rates? J Assist Reprod Genet. 1993;10:31–6.PubMedCrossRef
10.
go back to reference Ghazzawi IM, Al-Hasani S, Karaki R, Souso S. Transfer technique and catheter choice influence the incidence of transcervical embryo expulsion and the outcome of IVF. Hum Reprod. 1999;14:677–82.PubMedCrossRef Ghazzawi IM, Al-Hasani S, Karaki R, Souso S. Transfer technique and catheter choice influence the incidence of transcervical embryo expulsion and the outcome of IVF. Hum Reprod. 1999;14:677–82.PubMedCrossRef
11.
go back to reference Urman B, Aksoy S, Alatas C, Mercan R, Nuhoglu A, Isiklar A, et al. Comparing two embryo transfer catheters. Use of a trial transfer to determine the catheter applied. J Reprod Med. 2000;45:135–8.PubMed Urman B, Aksoy S, Alatas C, Mercan R, Nuhoglu A, Isiklar A, et al. Comparing two embryo transfer catheters. Use of a trial transfer to determine the catheter applied. J Reprod Med. 2000;45:135–8.PubMed
12.
go back to reference Burke LM, Davenport AT, Russell GB, Deaton JL. Predictors of success after embryo transfer: experience from a single provider. Am J Obstet Gynecol. 2000;182:1001–4.PubMedCrossRef Burke LM, Davenport AT, Russell GB, Deaton JL. Predictors of success after embryo transfer: experience from a single provider. Am J Obstet Gynecol. 2000;182:1001–4.PubMedCrossRef
13.
go back to reference Saldeen P, Abou-Setta AM, Bergh T, Sundström P, Holte J. A prospective randomized controlled trial comparing two embryo transfer catheters in an ART program. Fertil Steril. 2008;90:599–603.PubMedCrossRef Saldeen P, Abou-Setta AM, Bergh T, Sundström P, Holte J. A prospective randomized controlled trial comparing two embryo transfer catheters in an ART program. Fertil Steril. 2008;90:599–603.PubMedCrossRef
14.
go back to reference Matorras R, Mendoza R, Expósito A, Rodriguez-Escudero FJ. Influence of the time interval between embryo catheter loading and discharging on the success of IVF. Hum Reprod. 2004;19:2027–30.PubMedCrossRef Matorras R, Mendoza R, Expósito A, Rodriguez-Escudero FJ. Influence of the time interval between embryo catheter loading and discharging on the success of IVF. Hum Reprod. 2004;19:2027–30.PubMedCrossRef
15.
go back to reference Lesny P, Killick SR, Robinson J, Raven G, Maguiness SD. Junctional zone contractions and embryo transfer: is it safe to use a tenaculum? Hum Reprod. 1999;14:2367–70.PubMedCrossRef Lesny P, Killick SR, Robinson J, Raven G, Maguiness SD. Junctional zone contractions and embryo transfer: is it safe to use a tenaculum? Hum Reprod. 1999;14:2367–70.PubMedCrossRef
16.
go back to reference Martínez F, Coroleu B, Parriego M, Carreras O, Belil I, Parera N, et al. Ultrasound-guided embryo transfer: immediate withdrawal of the catheter versus a 30 second wait. Hum Reprod. 2001;16:871–4.PubMedCrossRef Martínez F, Coroleu B, Parriego M, Carreras O, Belil I, Parera N, et al. Ultrasound-guided embryo transfer: immediate withdrawal of the catheter versus a 30 second wait. Hum Reprod. 2001;16:871–4.PubMedCrossRef
17.
go back to reference Goudas VT, Hammitt DG, Damario MA, Session DR, Singh AP, Dumesic DA. Blood on the embryo transfer catheter is associated with decreased rates of embryo implantation and clinical pregnancy with the use of in vitro fertilization-embryo transfer. Fertil Steril. 1998;70:878–82.PubMedCrossRef Goudas VT, Hammitt DG, Damario MA, Session DR, Singh AP, Dumesic DA. Blood on the embryo transfer catheter is associated with decreased rates of embryo implantation and clinical pregnancy with the use of in vitro fertilization-embryo transfer. Fertil Steril. 1998;70:878–82.PubMedCrossRef
18.
go back to reference Egbase PE, al-Sharhan M, al-Othman S, al-Mutawa M, Udo EE, Grudzinskas JG. Incidence of microbial growth from the tip of the embryo transfer catheter after embryo transfer in relation to clinical pregnancy rate following in-vitro fertilization and embryo transfer. Hum Reprod. 1996;11:1687–9.PubMedCrossRef Egbase PE, al-Sharhan M, al-Othman S, al-Mutawa M, Udo EE, Grudzinskas JG. Incidence of microbial growth from the tip of the embryo transfer catheter after embryo transfer in relation to clinical pregnancy rate following in-vitro fertilization and embryo transfer. Hum Reprod. 1996;11:1687–9.PubMedCrossRef
19.
go back to reference Moore DE, Soules MR, Klein NA, Fujimoto VY, Agnew KJ, Eschenbach DA. Bacteria in the transfer catheter tip influence the live-birth rate after in vitro fertilization. Fertil Steril. 2000;74:1118–24.PubMedCrossRef Moore DE, Soules MR, Klein NA, Fujimoto VY, Agnew KJ, Eschenbach DA. Bacteria in the transfer catheter tip influence the live-birth rate after in vitro fertilization. Fertil Steril. 2000;74:1118–24.PubMedCrossRef
20.
go back to reference Coroleu B, Barri PN, Carreras O, Martínez F, Parriego M, Hereter L, et al. The influence of the depth of embryo replacement into the uterine cavity on implantation rates after IVF: a controlled, ultrasound-guided study. Hum Reprod. 2002;17:341–6.PubMedCrossRef Coroleu B, Barri PN, Carreras O, Martínez F, Parriego M, Hereter L, et al. The influence of the depth of embryo replacement into the uterine cavity on implantation rates after IVF: a controlled, ultrasound-guided study. Hum Reprod. 2002;17:341–6.PubMedCrossRef
21.
go back to reference Franco Jr JG, Martins AM, Baruffi RL, Mauri AL, Petersen CG, Felipe V, et al. Best site for embryo transfer: the upper or lower half of endometrial cavity? Hum Reprod. 2004;19:1785–90.PubMedCrossRef Franco Jr JG, Martins AM, Baruffi RL, Mauri AL, Petersen CG, Felipe V, et al. Best site for embryo transfer: the upper or lower half of endometrial cavity? Hum Reprod. 2004;19:1785–90.PubMedCrossRef
22.
go back to reference Oliveira JB, Martins AM, Baruffi RL, Mauri AL, Petersen CG, Felipe V, et al. Increased implantation and pregnancy rates obtained by placing the tip of the transfer catheter in the central area of the endometrial cavity. Reprod Biomed Online. 2004;9:435–41.PubMedCrossRef Oliveira JB, Martins AM, Baruffi RL, Mauri AL, Petersen CG, Felipe V, et al. Increased implantation and pregnancy rates obtained by placing the tip of the transfer catheter in the central area of the endometrial cavity. Reprod Biomed Online. 2004;9:435–41.PubMedCrossRef
23.
go back to reference Abou-Setta AM. What is the best site for embryo deposition? A systematic review and meta-analysis using direct and adjusted indirect comparisons. Reprod Biomed Online. 2007;14:611–9.PubMedCrossRef Abou-Setta AM. What is the best site for embryo deposition? A systematic review and meta-analysis using direct and adjusted indirect comparisons. Reprod Biomed Online. 2007;14:611–9.PubMedCrossRef
24.
go back to reference Veeck LL. Atlas of the Human Oocyte and Early Conceptus. Baltimore, MD: Williams and Wilkins; 1991. Veeck LL. Atlas of the Human Oocyte and Early Conceptus. Baltimore, MD: Williams and Wilkins; 1991.
25.
go back to reference Lewin A, Schenker JG, Avrech O, Shapira S, Safran A, Friedler S. The role of uterine straightening by passive bladder distension before embryo transfer in IVF cycles. J Assist Reprod Genet. 1997;14:32–4.PubMedCentralPubMedCrossRef Lewin A, Schenker JG, Avrech O, Shapira S, Safran A, Friedler S. The role of uterine straightening by passive bladder distension before embryo transfer in IVF cycles. J Assist Reprod Genet. 1997;14:32–4.PubMedCentralPubMedCrossRef
26.
go back to reference Minami S, Ishihara K, Araki T. Determination of blastocyst implantation site in spontaneous pregnancies using three-dimensional transvaginal ultrasound. J Nippon Med Sch. 2003;70:250–4.PubMedCrossRef Minami S, Ishihara K, Araki T. Determination of blastocyst implantation site in spontaneous pregnancies using three-dimensional transvaginal ultrasound. J Nippon Med Sch. 2003;70:250–4.PubMedCrossRef
27.
go back to reference Baba K, Ishihara O, Hayashi N, Saitoh M, Taya J, Kinoshita K. Where does the embryo implant after embryo transfer in humans? Fertil Steril. 2000;73:123–5.PubMedCrossRef Baba K, Ishihara O, Hayashi N, Saitoh M, Taya J, Kinoshita K. Where does the embryo implant after embryo transfer in humans? Fertil Steril. 2000;73:123–5.PubMedCrossRef
28.
go back to reference Kinoshita K. Clinical significance of detection time and site of early gestational sac by ultrasonography. Nihon Sanka Fujinka Gakkai Zasshi. 1994;46:102–8.PubMed Kinoshita K. Clinical significance of detection time and site of early gestational sac by ultrasonography. Nihon Sanka Fujinka Gakkai Zasshi. 1994;46:102–8.PubMed
29.
go back to reference Kerin JF, Jeffrey R, Warnes GM, Cox LW, Broom TJ. A simple technique for human embryo transfer into the uterus. Lancet. 1981;2:726–7.PubMedCrossRef Kerin JF, Jeffrey R, Warnes GM, Cox LW, Broom TJ. A simple technique for human embryo transfer into the uterus. Lancet. 1981;2:726–7.PubMedCrossRef
30.
go back to reference Leeton J, Trounson A, Jessup D, Wood C. The technique for human embryo transfer. Fertil Steril. 1982;38:156–61.PubMed Leeton J, Trounson A, Jessup D, Wood C. The technique for human embryo transfer. Fertil Steril. 1982;38:156–61.PubMed
31.
go back to reference Fanchin R, Righini C, Olivennes F, Taylor S, de Ziegler D, Frydman R. Uterine contractions at the time of embryo transfer alter pregnancy rates after in-vitro fertilization. Hum Reprod. 1998;13:1968–74.PubMedCrossRef Fanchin R, Righini C, Olivennes F, Taylor S, de Ziegler D, Frydman R. Uterine contractions at the time of embryo transfer alter pregnancy rates after in-vitro fertilization. Hum Reprod. 1998;13:1968–74.PubMedCrossRef
32.
go back to reference Lesny P, Killick SR, Tetlow RL, Robinson J, Maguiness SD. Embryo transfer—can we learn anything new from the observation of junctional zone contractions? Hum Reprod. 1998;13:1540–6.PubMedCrossRef Lesny P, Killick SR, Tetlow RL, Robinson J, Maguiness SD. Embryo transfer—can we learn anything new from the observation of junctional zone contractions? Hum Reprod. 1998;13:1540–6.PubMedCrossRef
33.
go back to reference Woolcott R, Stanger J. Potentially important variables identified by transvaginal ultrasound-guided embryo transfer. Hum Reprod. 1997;12:963–6.PubMedCrossRef Woolcott R, Stanger J. Potentially important variables identified by transvaginal ultrasound-guided embryo transfer. Hum Reprod. 1997;12:963–6.PubMedCrossRef
34.
go back to reference Pope CS, Cook EK, Arny M, Novak A, Grow DR. Influence of embryo transfer depth on in vitro fertilization and embryo transfer outcomes. Fertil Steril. 2004;81:51–8.PubMedCrossRef Pope CS, Cook EK, Arny M, Novak A, Grow DR. Influence of embryo transfer depth on in vitro fertilization and embryo transfer outcomes. Fertil Steril. 2004;81:51–8.PubMedCrossRef
35.
go back to reference Tiras B, Polat M, Korucuoglu U, Zeyneloglu HB, Yarali H. Impact of embryo replacement depth on in vitro fertilization and embryo transfer outcomes. Fertil Steril. 2010;94:1341–5.PubMedCrossRef Tiras B, Polat M, Korucuoglu U, Zeyneloglu HB, Yarali H. Impact of embryo replacement depth on in vitro fertilization and embryo transfer outcomes. Fertil Steril. 2010;94:1341–5.PubMedCrossRef
36.
go back to reference Rovei V, Dalmasso P, Gennarelli G, Lantieri T, Basso G, Benedetto C, Revelli A. IVF outcome is optimized when embryos are replaced between 5 and 15 mm from the fundal endometrial surface: a prospective analysis on 1184 IVF cycles. Reprod Biol Endocrinol. 2013;11. doi: 10.1186/1477-7827-11-114. Rovei V, Dalmasso P, Gennarelli G, Lantieri T, Basso G, Benedetto C, Revelli A. IVF outcome is optimized when embryos are replaced between 5 and 15 mm from the fundal endometrial surface: a prospective analysis on 1184 IVF cycles. Reprod Biol Endocrinol. 2013;11. doi: 10.​1186/​1477-7827-11-114.
37.
go back to reference Pacchiarotti A, Mohamed MA, Micara G, Tranquilli D, Linari A, Espinola SM, et al. The impact of the depth of embryo replacement on IVF outcome. J Assist Reprod Genet. 2007;24:189–93.PubMedCentralPubMedCrossRef Pacchiarotti A, Mohamed MA, Micara G, Tranquilli D, Linari A, Espinola SM, et al. The impact of the depth of embryo replacement on IVF outcome. J Assist Reprod Genet. 2007;24:189–93.PubMedCentralPubMedCrossRef
38.
go back to reference Nazari A, Askari HA, Check JH, O'Shaughnessy A. Embryo transfer technique as a cause of ectopic pregnancy in in vitro fertilization. Fertil Steril. 1993;60:919–21.PubMed Nazari A, Askari HA, Check JH, O'Shaughnessy A. Embryo transfer technique as a cause of ectopic pregnancy in in vitro fertilization. Fertil Steril. 1993;60:919–21.PubMed
39.
go back to reference Frankfurter D, Trimarchi JB, Silva CP, Keefe DL. Middle to lower uterine segment embryo transfer improves implantation and pregnancy rates compared with fundal embryo transfer. Fertil Steril. 2004;81:1273–7.PubMedCrossRef Frankfurter D, Trimarchi JB, Silva CP, Keefe DL. Middle to lower uterine segment embryo transfer improves implantation and pregnancy rates compared with fundal embryo transfer. Fertil Steril. 2004;81:1273–7.PubMedCrossRef
Metadata
Title
Absolute position versus relative position in embryo transfer: a randomized controlled trial
Authors
Hwang Kwon
Dong-Hee Choi
Eun-Kyung Kim
Publication date
01-12-2015
Publisher
BioMed Central
Published in
Reproductive Biology and Endocrinology / Issue 1/2015
Electronic ISSN: 1477-7827
DOI
https://doi.org/10.1186/s12958-015-0072-6

Other articles of this Issue 1/2015

Reproductive Biology and Endocrinology 1/2015 Go to the issue