Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2022

Open Access 01-12-2022 | Research

Efficacy and safety of a 3D-printed arthrodesis prosthesis for reconstruction after resection of the proximal humerus: preliminary outcomes with a minimum 2-year follow-up

Authors: Haijie Liang, Wei Guo, Yi Yang, Dasen Li, Rongli Yang, Xiaodong Tang, Taiqiang Yan

Published in: BMC Musculoskeletal Disorders | Issue 1/2022

Login to get access

Abstract

Background

The purpose of this study was to investigate the feasibility of using a three-dimensional (3D)-printed arthrodesis prosthesis for reconstruction of the proximal humeral defect after tumor resection.

Methods

A novel proximal humeral prosthesis was designed to restore bone continuity and shoulder arthrodesis and was fabricated via 3D printing technology. Ten patients with primary malignancies in the proximal humerus underwent intra-articular resection and replacement with this prosthesis from 2017 to 2019. Baseline and operative data, oncological and prosthetic survival, and functional status were summarized.

Results

This cohort consisted of 9 males and 1 female with a mean age of 32.1 ± 16.1 years. Diagnoses included 5 cases of osteosarcoma, 3 cases of chondrosarcoma and 1 each case of undifferentiated pleomorphic sarcoma and malignant myoepithelioma. The mean operative duration, intraoperative hemorrhage and postoperative length of hospitalization were 151.5 ± 61.0 min, 410.0 ± 353.4 ml and 5.3 ± 1.9 d, respectively. The mean follow-up duration was 29.3 ± 6.4 months, with a minimum of 24 months for the surviving patients. Two patients experienced local recurrence, and four patients developed distant metastases. Detachment of the taper occurred in two patients. One was managed conservatively, and the other received amputation due to concurrent tumor recurrence. The mean MSTS-93 and ASES scores and ranges of forwards flexion and abduction were 24.9 ± 3.1, 79.4 ± 8.3, 71.3 ± 19.4°, and 61.3 ± 16.4°, respectively. The functional outcomes were independent of the preservation of the axillary nerve. Histological study of the glenoid component showed evidence of bone ingrowth at the bone-prosthesis porous interface.

Conclusion

Application of the 3D-printed arthrodesis prosthesis might be a safe and efficacious method for functional reconstruction in patients who underwent resection of the proximal humerus, especially for those without preservation of the axillary nerve.
Appendix
Available only for authorised users
Literature
1.
go back to reference Dubina A, Shiu B, Gilotra M, Hasan SA, Lerman D, Ng VY. What is the optimal reconstruction option after the resection of proximal humeral tumors? A Systematic Review. Open Orthop J. 2017;11:203–11.CrossRef Dubina A, Shiu B, Gilotra M, Hasan SA, Lerman D, Ng VY. What is the optimal reconstruction option after the resection of proximal humeral tumors? A Systematic Review. Open Orthop J. 2017;11:203–11.CrossRef
2.
go back to reference Teunis T, Nota SP, Hornicek FJ, Schwab JH, Lozano-Calderon SA. Outcome after reconstruction of the proximal humerus for tumor resection: a systematic review. Clin Orthop Relat Res. 2014;472(7):2245–53.CrossRef Teunis T, Nota SP, Hornicek FJ, Schwab JH, Lozano-Calderon SA. Outcome after reconstruction of the proximal humerus for tumor resection: a systematic review. Clin Orthop Relat Res. 2014;472(7):2245–53.CrossRef
3.
go back to reference Tang X, Guo W, Yang R, Tang S, Ji T. Synthetic mesh improves shoulder function after intraarticular resection and prosthetic replacement of proximal humerus. Clin Orthop Relat Res. 2015;473(4):1464–71.CrossRef Tang X, Guo W, Yang R, Tang S, Ji T. Synthetic mesh improves shoulder function after intraarticular resection and prosthetic replacement of proximal humerus. Clin Orthop Relat Res. 2015;473(4):1464–71.CrossRef
4.
go back to reference Abdeen A, Healey JH. Allograft-prosthesis composite reconstruction of the proximal part of the humerus: surgical technique. J Bone Joint Surg Am. 2010;92(Suppl 1 Pt 2):188–96.CrossRef Abdeen A, Healey JH. Allograft-prosthesis composite reconstruction of the proximal part of the humerus: surgical technique. J Bone Joint Surg Am. 2010;92(Suppl 1 Pt 2):188–96.CrossRef
5.
go back to reference El Beaino M, Liu J, Lewis VO, Lin PP. Do early results of proximal humeral allograft-prosthetic composite reconstructions persist at 5-year Followup? Clin Orthop Relat Res. 2019;477(4):758–65.CrossRef El Beaino M, Liu J, Lewis VO, Lin PP. Do early results of proximal humeral allograft-prosthetic composite reconstructions persist at 5-year Followup? Clin Orthop Relat Res. 2019;477(4):758–65.CrossRef
6.
go back to reference Grosel TW, Plummer DR, Everhart JS, Kirven JC, Ziegler CL, Mayerson JL, et al. Reverse total shoulder arthroplasty provides stability and better function than hemiarthroplasty following resection of proximal humerus tumors. J Shoulder Elb Surg. 2019;28(11):2147–52.CrossRef Grosel TW, Plummer DR, Everhart JS, Kirven JC, Ziegler CL, Mayerson JL, et al. Reverse total shoulder arthroplasty provides stability and better function than hemiarthroplasty following resection of proximal humerus tumors. J Shoulder Elb Surg. 2019;28(11):2147–52.CrossRef
7.
go back to reference Kaa AK, Jorgensen PH, Sojbjerg JO, Johannsen HV. Reverse shoulder replacement after resection of the proximal humerus for bone tumours. Bone Joint J. 2013;95-B(11):1551–5.CrossRef Kaa AK, Jorgensen PH, Sojbjerg JO, Johannsen HV. Reverse shoulder replacement after resection of the proximal humerus for bone tumours. Bone Joint J. 2013;95-B(11):1551–5.CrossRef
8.
go back to reference Maclean S, Malik SS, Evans S, Gregory J, Jeys L. Reverse shoulder endoprosthesis for pathologic lesions of the proximal humerus: a minimum 3-year follow-up. J Shoulder Elb Surg. 2017;26(11):1990–4.CrossRef Maclean S, Malik SS, Evans S, Gregory J, Jeys L. Reverse shoulder endoprosthesis for pathologic lesions of the proximal humerus: a minimum 3-year follow-up. J Shoulder Elb Surg. 2017;26(11):1990–4.CrossRef
9.
go back to reference Gebhardt MC, Roth YF, Mankin HJ. Osteoarticular allografts for reconstruction in the proximal part of the humerus after excision of a musculoskeletal tumor. J Bone Joint Surg Am. 1990;72(3):334–45.CrossRef Gebhardt MC, Roth YF, Mankin HJ. Osteoarticular allografts for reconstruction in the proximal part of the humerus after excision of a musculoskeletal tumor. J Bone Joint Surg Am. 1990;72(3):334–45.CrossRef
10.
go back to reference Getty PJ, Peabody TD. Complications and functional outcomes of reconstruction with an osteoarticular allograft after intra-articular resection of the proximal aspect of the humerus. J Bone Joint Surg Am. 1999;81(8):1138–46.CrossRef Getty PJ, Peabody TD. Complications and functional outcomes of reconstruction with an osteoarticular allograft after intra-articular resection of the proximal aspect of the humerus. J Bone Joint Surg Am. 1999;81(8):1138–46.CrossRef
11.
go back to reference Amin SN, Ebeid WA. Shoulder reconstruction after tumor resection by pedicled scapular crest graft. Clin Orthop Relat Res. 2002;397:133–42.CrossRef Amin SN, Ebeid WA. Shoulder reconstruction after tumor resection by pedicled scapular crest graft. Clin Orthop Relat Res. 2002;397:133–42.CrossRef
12.
go back to reference Bilgin SS. Reconstruction of proximal humeral defects with shoulder arthrodesis using free vascularized fibular graft. J Bone Joint Surg Am. 2012;94(13):e94.CrossRef Bilgin SS. Reconstruction of proximal humeral defects with shoulder arthrodesis using free vascularized fibular graft. J Bone Joint Surg Am. 2012;94(13):e94.CrossRef
13.
go back to reference Barbier D, De Billy B, Gicquel P, Bourelle S, Journeau P. Is the Clavicula pro Humero technique of value for reconstruction after resection of the proximal Humerus in children? Clin Orthop Relat Res. 2017;475(10):2550–61.CrossRef Barbier D, De Billy B, Gicquel P, Bourelle S, Journeau P. Is the Clavicula pro Humero technique of value for reconstruction after resection of the proximal Humerus in children? Clin Orthop Relat Res. 2017;475(10):2550–61.CrossRef
14.
go back to reference Fujibuchi T, Matsumoto S, Shimoji T, Ae K, Tanizawa T, Gokita T, et al. New endoprosthesis suspension method with polypropylene monofilament knitted mesh after resection of bone tumors in proximal humerus. J Shoulder Elb Surg. 2015;24(6):882–8.CrossRef Fujibuchi T, Matsumoto S, Shimoji T, Ae K, Tanizawa T, Gokita T, et al. New endoprosthesis suspension method with polypropylene monofilament knitted mesh after resection of bone tumors in proximal humerus. J Shoulder Elb Surg. 2015;24(6):882–8.CrossRef
15.
go back to reference Raiss P, Kinkel S, Sauter U, Bruckner T, Lehner B. Replacement of the proximal humerus with MUTARS tumor endoprostheses. Eur J Surg Oncol. 2010;36(4):371–7.CrossRef Raiss P, Kinkel S, Sauter U, Bruckner T, Lehner B. Replacement of the proximal humerus with MUTARS tumor endoprostheses. Eur J Surg Oncol. 2010;36(4):371–7.CrossRef
16.
go back to reference Chauhan VS, Vaish A, Vaishya R. Reverse shoulder arthroplasty after failed megaprosthesis for osteosarcoma of the proximal humerus: a case report and review of literature. J Clin Orthop Trauma. 2019;10(3):526–30.CrossRef Chauhan VS, Vaish A, Vaishya R. Reverse shoulder arthroplasty after failed megaprosthesis for osteosarcoma of the proximal humerus: a case report and review of literature. J Clin Orthop Trauma. 2019;10(3):526–30.CrossRef
17.
go back to reference Viehweger E, Gonzalez JF, Launay F, Legre R, Jouve JL, Bollini G. Shoulder arthrodesis with vascularized fibular graft after tumor resection of the proximal humerus. Rev Chir Orthop Reparatrice Appar Mot. 2005;91(6):523–9.CrossRef Viehweger E, Gonzalez JF, Launay F, Legre R, Jouve JL, Bollini G. Shoulder arthrodesis with vascularized fibular graft after tumor resection of the proximal humerus. Rev Chir Orthop Reparatrice Appar Mot. 2005;91(6):523–9.CrossRef
18.
go back to reference Liang H, Ji T, Zhang Y, Wang Y, Guo W. Reconstruction with 3D-printed pelvic endoprostheses after resection of a pelvic tumour. Bone Joint J. 2017;99-B(2):267–75.CrossRef Liang H, Ji T, Zhang Y, Wang Y, Guo W. Reconstruction with 3D-printed pelvic endoprostheses after resection of a pelvic tumour. Bone Joint J. 2017;99-B(2):267–75.CrossRef
19.
go back to reference Shah FA, Snis A, Matic A, Thomsen P, Palmquist A. 3D printed Ti6Al4V implant surface promotes bone maturation and retains a higher density of less aged osteocytes at the bone-implant interface. Acta Biomater. 2016;30:357–67.CrossRef Shah FA, Snis A, Matic A, Thomsen P, Palmquist A. 3D printed Ti6Al4V implant surface promotes bone maturation and retains a higher density of less aged osteocytes at the bone-implant interface. Acta Biomater. 2016;30:357–67.CrossRef
20.
go back to reference Sing SL, An J, Yeong WY, Wiria FE. Laser and electron-beam powder-bed additive manufacturing of metallic implants: a review on processes, materials and designs. J Orthop Res. 2016;34(3):369–85.CrossRef Sing SL, An J, Yeong WY, Wiria FE. Laser and electron-beam powder-bed additive manufacturing of metallic implants: a review on processes, materials and designs. J Orthop Res. 2016;34(3):369–85.CrossRef
21.
go back to reference Wei R, Guo W, Yang R, Tang X, Yang Y, Ji T. Plate-prosthesis composite reconstruction after large segmental resection of proximal humeral tumors: a retrospective comparative study. Medicine (Baltimore). 2019;98(22):e15787.CrossRef Wei R, Guo W, Yang R, Tang X, Yang Y, Ji T. Plate-prosthesis composite reconstruction after large segmental resection of proximal humeral tumors: a retrospective comparative study. Medicine (Baltimore). 2019;98(22):e15787.CrossRef
22.
go back to reference Enneking WF, Dunham W, Gebhardt MC, Malawar M, Pritchard DJ. A system for the functional evaluation of reconstructive procedures after surgical treatment of tumors of the musculoskeletal system. Clin Orthop Relat Res. 1993;286:241–6.CrossRef Enneking WF, Dunham W, Gebhardt MC, Malawar M, Pritchard DJ. A system for the functional evaluation of reconstructive procedures after surgical treatment of tumors of the musculoskeletal system. Clin Orthop Relat Res. 1993;286:241–6.CrossRef
23.
go back to reference Richards RR, An KN, Bigliani LU, Friedman RJ, Gartsman GM, Gristina AG, et al. A standardized method for the assessment of shoulder function. J Shoulder Elb Surg. 1994;3(6):347–52.CrossRef Richards RR, An KN, Bigliani LU, Friedman RJ, Gartsman GM, Gristina AG, et al. A standardized method for the assessment of shoulder function. J Shoulder Elb Surg. 1994;3(6):347–52.CrossRef
24.
go back to reference Henderson ER, Groundland JS, Pala E, Dennis JA, Wooten R, Cheong D, et al. Failure mode classification for tumor endoprostheses: retrospective review of five institutions and a literature review. J Bone Joint Surg Am. 2011;93(5):418–29.CrossRef Henderson ER, Groundland JS, Pala E, Dennis JA, Wooten R, Cheong D, et al. Failure mode classification for tumor endoprostheses: retrospective review of five institutions and a literature review. J Bone Joint Surg Am. 2011;93(5):418–29.CrossRef
25.
go back to reference van der Helm FC, Pronk GM. Loading of shoulder girdle muscles in consequence of a glenohumeral arthrodesis. Clin Biomech (Bristol, Avon). 1994;9(3):139–48.CrossRef van der Helm FC, Pronk GM. Loading of shoulder girdle muscles in consequence of a glenohumeral arthrodesis. Clin Biomech (Bristol, Avon). 1994;9(3):139–48.CrossRef
26.
go back to reference Calvert GT, Wright J, Agarwal J, Jones KB, Randall RL. Is claviculo pro humeri of value for limb salvage of pediatric proximal humerus sarcomas? Clin Orthop Relat Res. 2015;473(3):877–82.CrossRef Calvert GT, Wright J, Agarwal J, Jones KB, Randall RL. Is claviculo pro humeri of value for limb salvage of pediatric proximal humerus sarcomas? Clin Orthop Relat Res. 2015;473(3):877–82.CrossRef
27.
go back to reference Trovarelli G, Cappellari A, Angelini A, Pala E, Ruggieri P. What is the survival and function of modular reverse Total shoulder prostheses in patients undergoing tumor resections in whom an innervated deltoid muscle can be preserved? Clin Orthop Relat Res. 2019;477(11):2495–507.CrossRef Trovarelli G, Cappellari A, Angelini A, Pala E, Ruggieri P. What is the survival and function of modular reverse Total shoulder prostheses in patients undergoing tumor resections in whom an innervated deltoid muscle can be preserved? Clin Orthop Relat Res. 2019;477(11):2495–507.CrossRef
28.
go back to reference Guven MF, Aslan L, Botanlioglu H, Kaynak G, Kesmezacar H, Babacan M. Functional outcome of reverse shoulder tumor prosthesis in the treatment of proximal humerus tumors. J Shoulder Elb Surg. 2016;25(1):e1–6.CrossRef Guven MF, Aslan L, Botanlioglu H, Kaynak G, Kesmezacar H, Babacan M. Functional outcome of reverse shoulder tumor prosthesis in the treatment of proximal humerus tumors. J Shoulder Elb Surg. 2016;25(1):e1–6.CrossRef
29.
go back to reference Bonnevialle N, Mansat P, Lebon J, Laffosse JM, Bonnevialle P. Reverse shoulder arthroplasty for malignant tumors of proximal humerus. J Shoulder Elb Surg. 2015;24(1):36–44.CrossRef Bonnevialle N, Mansat P, Lebon J, Laffosse JM, Bonnevialle P. Reverse shoulder arthroplasty for malignant tumors of proximal humerus. J Shoulder Elb Surg. 2015;24(1):36–44.CrossRef
32.
go back to reference Mimata Y, Nishida J, Sato K, Suzuki Y, Doita M. Glenohumeral arthrodesis for malignant tumor of the shoulder girdle. J Shoulder Elb Surg. 2015;24(2):174–8.CrossRef Mimata Y, Nishida J, Sato K, Suzuki Y, Doita M. Glenohumeral arthrodesis for malignant tumor of the shoulder girdle. J Shoulder Elb Surg. 2015;24(2):174–8.CrossRef
33.
go back to reference Hriscu M, Mojallal A, Breton P, Bouletreau P, Carret JP. Limb salvage in proximal humerus malignant tumors: the place of free vascularized fibular graft. J Reconstr Microsurg. 2006;22(6):415–21.CrossRef Hriscu M, Mojallal A, Breton P, Bouletreau P, Carret JP. Limb salvage in proximal humerus malignant tumors: the place of free vascularized fibular graft. J Reconstr Microsurg. 2006;22(6):415–21.CrossRef
34.
go back to reference Fuchs B, O'Connor MI, Padgett DJ, Kaufman KR, Sim FH. Arthrodesis of the shoulder after tumor resection. Clin Orthop Relat Res. 2005;436:202–7.CrossRef Fuchs B, O'Connor MI, Padgett DJ, Kaufman KR, Sim FH. Arthrodesis of the shoulder after tumor resection. Clin Orthop Relat Res. 2005;436:202–7.CrossRef
35.
go back to reference Griffiths D, Gikas PD, Jowett C, Bayliss L, Aston W, Skinner J, et al. Proximal humeral replacement using a fixed-fulcrum endoprosthesis. J Bone Joint Surg Br. 2011;93(3):399–403.CrossRef Griffiths D, Gikas PD, Jowett C, Bayliss L, Aston W, Skinner J, et al. Proximal humeral replacement using a fixed-fulcrum endoprosthesis. J Bone Joint Surg Br. 2011;93(3):399–403.CrossRef
36.
go back to reference Probyn LJ, Wunder JS, Bell RS, Griffin AM, Davis AM. A comparison of outcome of osteoarticular allograft reconstruction and shoulder arthrodesis following resection of primary tumours of the proximal humerus. Sarcoma. 1998;2(3–4):163–70.CrossRef Probyn LJ, Wunder JS, Bell RS, Griffin AM, Davis AM. A comparison of outcome of osteoarticular allograft reconstruction and shoulder arthrodesis following resection of primary tumours of the proximal humerus. Sarcoma. 1998;2(3–4):163–70.CrossRef
37.
go back to reference Blewitt N, Pooley J. Resection arthrodesis of the shoulder with autogenous fibular bone grafts. J Shoulder Elb Surg. 1994;3(5):307–12.CrossRef Blewitt N, Pooley J. Resection arthrodesis of the shoulder with autogenous fibular bone grafts. J Shoulder Elb Surg. 1994;3(5):307–12.CrossRef
Metadata
Title
Efficacy and safety of a 3D-printed arthrodesis prosthesis for reconstruction after resection of the proximal humerus: preliminary outcomes with a minimum 2-year follow-up
Authors
Haijie Liang
Wei Guo
Yi Yang
Dasen Li
Rongli Yang
Xiaodong Tang
Taiqiang Yan
Publication date
01-12-2022
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2022
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-022-05581-6

Other articles of this Issue 1/2022

BMC Musculoskeletal Disorders 1/2022 Go to the issue