Abstract

Background

No study has assessed the feasibility and safety of cervical pedicle screw implantation in patients with vertebral artery dominance (VAD), a common vertebral artery (VA) variation which can increase VA injury (VAI) risk. This study was to assess morphological characteristics of the subaxial cervical pedicles and surrounding critical structures, and identify their correlations in patients with VAD.

Methods

Computed tomography arteriography scans of 152 patients were used for retrospectively measuring parameters including pedicle outer width (POW), the distance from the lateral pedicle border to the closest part of VA (DPVA), diameter of VA (DVA), area of VA (AVA), area of transverse foramen (ATF) and occupational ratio of transverse foramen (TF). Moreover, correlations among some critical parameters were assessed.

Results

One hundred eight males and 44 females, with a mean age of 55.9 years were included. POW was smaller on the dominant side than on the non-dominant side, whereas DPVA, DVA, AVA, ATF, and TF were larger on the dominant side than those on the non-dominant side. On both sides, POW < 4 mm and POW + DPVA < 5 mm were observed most frequently at C3 and C4. On both sides, POW was correlated to ATF, and ATF was correlated to DVA and AVA. DPVA was correlated to ATF on the dominant side.

Conclusion

Patients with VAD exhibited smaller POW on the dominant side, most frequently at C3 and C4. Dominant VA may indirectly affect POW. TF may be a key determinant of DPVA and POW.
Literature
1.
go back to reference Abumi K, Itoh H, Taneichi H, Kaneda K. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord. 1994;7:19–28.CrossRef Abumi K, Itoh H, Taneichi H, Kaneda K. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord. 1994;7:19–28.CrossRef
2.
go back to reference Johnston TL, Karaikovic EE, Lautenschlager EP, Marcu D. Cervical pedicle screws vs. lateral mass screws: uniplanar fatigue analysis and residual pullout strengths. Spine J. 2006;6:667–72.CrossRef Johnston TL, Karaikovic EE, Lautenschlager EP, Marcu D. Cervical pedicle screws vs. lateral mass screws: uniplanar fatigue analysis and residual pullout strengths. Spine J. 2006;6:667–72.CrossRef
3.
go back to reference Kothe R, Rüther W, Schneider E, Linke B. Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine. Spine (Phila Pa 1976). 2004;29:1869–75.CrossRef Kothe R, Rüther W, Schneider E, Linke B. Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine. Spine (Phila Pa 1976). 2004;29:1869–75.CrossRef
4.
go back to reference Ito Z, Higashino K, Kato S, Kim SS, Wong E, Yoshioka K, et al. Pedicle screws can be 4 times stronger than lateral mass screws for insertion in the midcervical spine: a biomechanical study on strength of fixation. J Spinal Disord Tech. 2014;27:80–5.CrossRef Ito Z, Higashino K, Kato S, Kim SS, Wong E, Yoshioka K, et al. Pedicle screws can be 4 times stronger than lateral mass screws for insertion in the midcervical spine: a biomechanical study on strength of fixation. J Spinal Disord Tech. 2014;27:80–5.CrossRef
5.
go back to reference Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K. Complications of Pedicle Screw Fixation in Reconstructive Surgery of the Cervical Spine. Spine (Phila Pa 1976). 2000;25:962–9.CrossRef Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K. Complications of Pedicle Screw Fixation in Reconstructive Surgery of the Cervical Spine. Spine (Phila Pa 1976). 2000;25:962–9.CrossRef
6.
go back to reference Yukawa Y, Kato F, Ito K, Horie Y, Hida T, Nakashima H, et al. Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope. Eur Spine J. 2009;18:1293–9.CrossRef Yukawa Y, Kato F, Ito K, Horie Y, Hida T, Nakashima H, et al. Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope. Eur Spine J. 2009;18:1293–9.CrossRef
7.
go back to reference Kast E, Mohr K, Richter HP, Börm W. Complications of transpedicular screw fixation in the cervical spine. Eur Spine J. 2006;15:327–34.CrossRef Kast E, Mohr K, Richter HP, Börm W. Complications of transpedicular screw fixation in the cervical spine. Eur Spine J. 2006;15:327–34.CrossRef
8.
go back to reference Neo M, Sakamoto T, Fujibayashi S, Nakamura T. The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine (Phila Pa 1976). 2005;30:2800–5.CrossRef Neo M, Sakamoto T, Fujibayashi S, Nakamura T. The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine (Phila Pa 1976). 2005;30:2800–5.CrossRef
9.
go back to reference Lee CH, Hong JT, Kang DH, Kim KJ, Kim SW, Kim SW, et al. Epidemiology of iatrogenic vertebral artery injury in cervical spine surgery: 21 multicenter studies. World Neurosurg. 2019;126:e1050–4.CrossRef Lee CH, Hong JT, Kang DH, Kim KJ, Kim SW, Kim SW, et al. Epidemiology of iatrogenic vertebral artery injury in cervical spine surgery: 21 multicenter studies. World Neurosurg. 2019;126:e1050–4.CrossRef
10.
go back to reference Smith MD, Emery SE, Dudley A, Murray KJ, Leventhal M. Vertebral artery injury during anterior decompression of the cervical spine. A retrospective review of ten patients. J Bone Joint Surg Br. 1993; 75:410–415. Smith MD, Emery SE, Dudley A, Murray KJ, Leventhal M. Vertebral artery injury during anterior decompression of the cervical spine. A retrospective review of ten patients. J Bone Joint Surg Br. 1993; 75:410–415.
11.
go back to reference Shintani A, Zervas NT. Consequence of ligation of the vertebral artery. J Neurosurg. 1972;36:447–50.CrossRef Shintani A, Zervas NT. Consequence of ligation of the vertebral artery. J Neurosurg. 1972;36:447–50.CrossRef
12.
go back to reference Panjabi MM, Duranceau J, Goel V, Oxland T, Takata K. Cervical human vertebrae. Quantitative three-dimensional anatomy of the middle and lower regions. Spine (Phila Pa 1976).1991;16:861–9. Panjabi MM, Duranceau J, Goel V, Oxland T, Takata K. Cervical human vertebrae. Quantitative three-dimensional anatomy of the middle and lower regions. Spine (Phila Pa 1976).1991;16:861–9.
13.
go back to reference Grasso G, Alafaci C, Passalacqua M, Tschabitscher M, Salpietro FM, Tomasello F. Landmarks for vertebral artery repositioning in bulbar compression syndrome: anatomic and microsurgical nuances. Neurosurgery. 2005;56:160–4.CrossRef Grasso G, Alafaci C, Passalacqua M, Tschabitscher M, Salpietro FM, Tomasello F. Landmarks for vertebral artery repositioning in bulbar compression syndrome: anatomic and microsurgical nuances. Neurosurgery. 2005;56:160–4.CrossRef
14.
go back to reference Hong JM, Chung CS, Bang OY, Yong SW, Joo IS, Huh K. Vertebral artery dominance contributes to basilar artery curvature and peri-vertebrobasilar junctional infarcts. J Neurol Neurosurg Psychiatry. 2009;80:1087–92.CrossRef Hong JM, Chung CS, Bang OY, Yong SW, Joo IS, Huh K. Vertebral artery dominance contributes to basilar artery curvature and peri-vertebrobasilar junctional infarcts. J Neurol Neurosurg Psychiatry. 2009;80:1087–92.CrossRef
15.
go back to reference Songur A, Gonul Y, Ozen OA, Kucuker H, Uzun I, Bas O, et al. Variations in the intracranial vertebrobasilar system. Surg Radiol Anat. 2008;30:257–64.CrossRef Songur A, Gonul Y, Ozen OA, Kucuker H, Uzun I, Bas O, et al. Variations in the intracranial vertebrobasilar system. Surg Radiol Anat. 2008;30:257–64.CrossRef
16.
go back to reference Kotil K, Kilincer C. Sizes of the transverse foramina correlate with blood flow and dominance of vertebral arteries. Spine J. 2014;14:933–7.CrossRef Kotil K, Kilincer C. Sizes of the transverse foramina correlate with blood flow and dominance of vertebral arteries. Spine J. 2014;14:933–7.CrossRef
17.
go back to reference Ergun O, Gunes Tatar I, Birgi E, Hekimoglu B. Evaluation of vertebral artery dominance, hypoplasia and variations in the origin: angiographic study in 254 patients. Folia Morphol (Warsz).2016;75:33–7. Ergun O, Gunes Tatar I, Birgi E, Hekimoglu B. Evaluation of vertebral artery dominance, hypoplasia and variations in the origin: angiographic study in 254 patients. Folia Morphol (Warsz).2016;75:33–7.
18.
go back to reference Jeng JS, Yip PK. Evaluation of vertebral artery hypoplasia and asymmetry by color-coded duplexultrasonography. Ultrasound Med Biol. 2004;30:605–9.CrossRef Jeng JS, Yip PK. Evaluation of vertebral artery hypoplasia and asymmetry by color-coded duplexultrasonography. Ultrasound Med Biol. 2004;30:605–9.CrossRef
19.
go back to reference Misenhimer GR, Peek RD, Wiltse LL, Rothman SL, Widell Jr EH. Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size. Spine (Phila Pa 1976). 1989;14: 367–72. Misenhimer GR, Peek RD, Wiltse LL, Rothman SL, Widell Jr EH. Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size. Spine (Phila Pa 1976). 1989;14: 367–72.
20.
go back to reference Abumi K, Ito M, Sudo H. Reconstruction of the Subaxial Cervical Spine Using Pedicle Screw Instrumentation. Spine (Phila Pa 1976). 2012;37:E349–56.CrossRef Abumi K, Ito M, Sudo H. Reconstruction of the Subaxial Cervical Spine Using Pedicle Screw Instrumentation. Spine (Phila Pa 1976). 2012;37:E349–56.CrossRef
21.
go back to reference Richter M, Cakir B, Schmidt R. Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine (Phila Pa 1976). 2005;30:2280–7.CrossRef Richter M, Cakir B, Schmidt R. Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine (Phila Pa 1976). 2005;30:2280–7.CrossRef
22.
go back to reference Theologis AA, Burch S. Safety and Efficacy of Reconstruction of Complex Cervical Spine Pathology Using Pedicle Screws Inserted with Stealth Navigation and 3D Image-Guided (O-Arm) Technology. Spine (Phila Pa 1976). 2015;40:1397–406.CrossRef Theologis AA, Burch S. Safety and Efficacy of Reconstruction of Complex Cervical Spine Pathology Using Pedicle Screws Inserted with Stealth Navigation and 3D Image-Guided (O-Arm) Technology. Spine (Phila Pa 1976). 2015;40:1397–406.CrossRef
23.
go back to reference Patton AG, Morris RP, Kuo YF, Lindsey RW. Accuracy of fluoroscopy versus computer-assisted navigation for the placement of anterior cervical pedicle screws. Spine (Phila Pa 1976). 2015;40:E404–10.CrossRef Patton AG, Morris RP, Kuo YF, Lindsey RW. Accuracy of fluoroscopy versus computer-assisted navigation for the placement of anterior cervical pedicle screws. Spine (Phila Pa 1976). 2015;40:E404–10.CrossRef
24.
go back to reference Rienmüller A, Buchmann N, Kirschke JS, Meyer EL, Gempt J, Lehmberg J, et al. Accuracy of CT-navigated pedicle screw positioning in the cervical and upper thoracic region with and without prior anterior surgery and ventral plating. Bone Joint J. 2017;99:1373–80.CrossRef Rienmüller A, Buchmann N, Kirschke JS, Meyer EL, Gempt J, Lehmberg J, et al. Accuracy of CT-navigated pedicle screw positioning in the cervical and upper thoracic region with and without prior anterior surgery and ventral plating. Bone Joint J. 2017;99:1373–80.CrossRef
Metadata
Title
Morphological characteristics of subaxial cervical pedicles and surrounding critical structures in patients with vertebral artery dominance - an anatomical study based on computed tomographic imaging
Authors
Jin Yang
Tao Li
Qing Wang
Gaoju Wang
Song Wang
Shuang Xu
Shuai Zhang
Qiuhan Li
Publication date
01-12-2022
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2022
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-022-05264-2

Other articles of this Issue 1/2022

BMC Musculoskeletal Disorders 1/2022 Go to the issue