Published in: BMC Ophthalmology 1/2017

Open Access 01-12-2017 | Research article

Comparison of visual outcomes, spectacles dependence and patient satisfaction of multifocal and accommodative intraocular lenses: innovative perspectives for maximal refractive-oriented cataract surgery

Authors: Raffaele Nuzzi, Federico Tridico

Published in: BMC Ophthalmology | Issue 1/2017

Login to get access

Abstract

Background

The aim of this study was to evaluate visual outcomes for different working distances (far, 60 cm and 33 cm) and impact on vision quality of multifocal IOLs AcrySof ResTOR SN6AD1 and SN6AD3 (Alcon, Inc., Fort Worth, Texas, USA) as well as REVIEW FIL611PV multifocal and OPTOFLEX FIL618 accommodative IOLs (Soleko, Ltd., Rome, Italy) in patients undergoing bilateral phacoemulsification.

Methods

In this observational prospective study 63 patients undergoing binocular cataract surgery were divided into four groups for implantation of one of the IOLs under evaluation. Visual outcomes were evaluated at 1 day, 7 days, 1 month, 3 months and 6 months after surgery. Patients’ satisfaction and spectacle independence were evaluated with questionnaires administered at the 6-months follow-up.

Results

Improvements in visual acuity for the three working distances were statistically significant in all cases compared to the preoperative status, especially after binocular implantation. The AcrySof ReSTOR SN6AD1 multifocal IOL provided the best visual acuity results and tolerability for all working distances. While performing worse than SN6AD1, FIL611PV and FIL618 provided better uncorrected visual acuity and spectacles independence for intermediate/close-up and far distances respectively, in comparison with the SN6AD3 group.

Conclusions

SN6AD1 was confirmed the best choice for all working distances. However, FIL611PV IOL may represent a valid and more cost-effective alternative, especially if surgeons intend to prioritize spectacle independence and patient autonomy at intermediate and close-up distances, in accordance to specific needs and requests.

Trial registration

Trial retrospectively registered in ISRCTN Registry on 02/02/2017. TRN: ISRCTN14145737.
Literature
2.
go back to reference Kupfer C. Bowman lecture: The conquest of cataract: A global challenge. Trans Ophthal Soc UK. 1984;104:1. Kupfer C. Bowman lecture: The conquest of cataract: A global challenge. Trans Ophthal Soc UK. 1984;104:1.
3.
go back to reference Chen LJ, Chang YJ, Kuo JC, Rajagopal R, Azar DT. Meta-analysis of cataract development after phakic intraocular lens surgery. J Cataract Refract Surg. 2008;34:1181–200.CrossRefPubMed Chen LJ, Chang YJ, Kuo JC, Rajagopal R, Azar DT. Meta-analysis of cataract development after phakic intraocular lens surgery. J Cataract Refract Surg. 2008;34:1181–200.CrossRefPubMed
4.
go back to reference Sperduto RD, Seigel D. Senile lens and senile macular changes in a population-based sample. Am J Ophthalmol. 1980;90:86.CrossRefPubMed Sperduto RD, Seigel D. Senile lens and senile macular changes in a population-based sample. Am J Ophthalmol. 1980;90:86.CrossRefPubMed
5.
go back to reference Gimbel HV, Sanders DR, Raanan MG. Visual and refractive results of multifocal intraocular lenses. Ophthalmology. 1991;98:881–7.CrossRefPubMed Gimbel HV, Sanders DR, Raanan MG. Visual and refractive results of multifocal intraocular lenses. Ophthalmology. 1991;98:881–7.CrossRefPubMed
6.
go back to reference Javitt JC, Steinert RF. Cataract extraction with multifocal intraocular lens implantation; a multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes. Ophthalmology. 2000;107:2040–8.CrossRefPubMed Javitt JC, Steinert RF. Cataract extraction with multifocal intraocular lens implantation; a multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes. Ophthalmology. 2000;107:2040–8.CrossRefPubMed
7.
go back to reference Cillino S, Casuccio A, Di Pace F, Moreale R, Pillitteri F, Cillino G, et al. One–Year outcomes with new generation multifocal intraocular lenses. Opthalmology. 2008;115:1508–16.CrossRef Cillino S, Casuccio A, Di Pace F, Moreale R, Pillitteri F, Cillino G, et al. One–Year outcomes with new generation multifocal intraocular lenses. Opthalmology. 2008;115:1508–16.CrossRef
8.
go back to reference Alfonso JF, Fernández-Vega L, Amhaz H, Montés-Micó R, Valcárcel B, Ferrer-Blasco T. Visual function after implantation of an aspheric bifocal intraocular lens. J Cataract Refract Surg. 2009;35:885–92.CrossRefPubMed Alfonso JF, Fernández-Vega L, Amhaz H, Montés-Micó R, Valcárcel B, Ferrer-Blasco T. Visual function after implantation of an aspheric bifocal intraocular lens. J Cataract Refract Surg. 2009;35:885–92.CrossRefPubMed
9.
go back to reference Alfonso JF, Fernández-Vega L, Baamonde MB, Montés-Micó R. Prospective visual evaluation of apodized diffractive intraocular lenses. J Cataract Refract Surg. 2007;33:1235–43.CrossRefPubMed Alfonso JF, Fernández-Vega L, Baamonde MB, Montés-Micó R. Prospective visual evaluation of apodized diffractive intraocular lenses. J Cataract Refract Surg. 2007;33:1235–43.CrossRefPubMed
10.
go back to reference Dick HB. Recent developments in aspheric intraocular lenses. Curr Opin Ophthalmol. 2009;20:25–32.CrossRefPubMed Dick HB. Recent developments in aspheric intraocular lenses. Curr Opin Ophthalmol. 2009;20:25–32.CrossRefPubMed
11.
go back to reference Davison JA, Simpson MJ. History and development of the apodized diffractive intraocular lens. J Cataract Refract Surg. 2006;32:849–58.CrossRefPubMed Davison JA, Simpson MJ. History and development of the apodized diffractive intraocular lens. J Cataract Refract Surg. 2006;32:849–58.CrossRefPubMed
12.
go back to reference Allò JL, Tavolato M, De la Hoz F, Claramonte P, Rodriguez-Prats JL, Galal A. Near vision restoration with refractive lens exchange and pseudoaccomodating and multifocal refractive and diffractive intraocular lenses: comparative clinical study. J Cataract Refract Surg. 2004;30:2494–503.CrossRef Allò JL, Tavolato M, De la Hoz F, Claramonte P, Rodriguez-Prats JL, Galal A. Near vision restoration with refractive lens exchange and pseudoaccomodating and multifocal refractive and diffractive intraocular lenses: comparative clinical study. J Cataract Refract Surg. 2004;30:2494–503.CrossRef
13.
go back to reference Montés-Micó R, Ferrer-Blasco T, Charman WN, Cerviño A, Alfonso JF, Fernández-Vega L. Optical quality of the eye after lens replacement by a pseudoaccommodating intraocular lens. J Cataract Refract Surg. 2008;34:763–8.CrossRefPubMed Montés-Micó R, Ferrer-Blasco T, Charman WN, Cerviño A, Alfonso JF, Fernández-Vega L. Optical quality of the eye after lens replacement by a pseudoaccommodating intraocular lens. J Cataract Refract Surg. 2008;34:763–8.CrossRefPubMed
14.
go back to reference Ossma IL, Glavis A, Vargas LG, Trager MJ, Reza Vagefi M, McLeod SD. Synchrony dual-optic accommodation intraocular lens. J Cataract Refract Surg. 2007;33:37–52.CrossRef Ossma IL, Glavis A, Vargas LG, Trager MJ, Reza Vagefi M, McLeod SD. Synchrony dual-optic accommodation intraocular lens. J Cataract Refract Surg. 2007;33:37–52.CrossRef
15.
go back to reference Koeppl C, Findl O, Menapace R, Kriechbaum K, Wirtitsch M, Buehl W, Sacu S, Drexler W. Pilocarpine-induced shift of an accommodating intraocular lens: AT-45 Crystalens. J Cataract Refract Surg. 2005;31(7):1290–7.CrossRefPubMed Koeppl C, Findl O, Menapace R, Kriechbaum K, Wirtitsch M, Buehl W, Sacu S, Drexler W. Pilocarpine-induced shift of an accommodating intraocular lens: AT-45 Crystalens. J Cataract Refract Surg. 2005;31(7):1290–7.CrossRefPubMed
16.
go back to reference Ong HS, Evans JR, Allan BD. Accommodative intraocular lens versus standard monofocal intraocular lens implantation in cataract surgery. Cochrane Database Syst Rev. 2014;5:CD009667. Ong HS, Evans JR, Allan BD. Accommodative intraocular lens versus standard monofocal intraocular lens implantation in cataract surgery. Cochrane Database Syst Rev. 2014;5:CD009667.
17.
go back to reference Petermeier K, Messias A, Gekeler F, Szurman P. Effect of +3.00 diopter and +4.00 diopter additions in multifocal intraocular lenses on defocus profiles, patient satisfaction, and contrast sensitivity. J Cataract Refract Surg. 2011;37:720–6.CrossRefPubMed Petermeier K, Messias A, Gekeler F, Szurman P. Effect of +3.00 diopter and +4.00 diopter additions in multifocal intraocular lenses on defocus profiles, patient satisfaction, and contrast sensitivity. J Cataract Refract Surg. 2011;37:720–6.CrossRefPubMed
18.
go back to reference Pieh S, Lackner B, Hanselmayer G, Zohrer R, Sticker M, Weghaupt H, Fercher A, Skorpik C. Halo size under distance and near conditions in refractive multifocal intraocular lenses. Br J Ophthalmol. 2001;85:816–21.CrossRefPubMedPubMedCentral Pieh S, Lackner B, Hanselmayer G, Zohrer R, Sticker M, Weghaupt H, Fercher A, Skorpik C. Halo size under distance and near conditions in refractive multifocal intraocular lenses. Br J Ophthalmol. 2001;85:816–21.CrossRefPubMedPubMedCentral
19.
20.
go back to reference Patel S, Alió JL, Feinbaum C. Comparison of Acri. Smart multifocal IOL, crystalens AT-45 accommodative IOL, and Technovision presbyLASIK for correcting presbyopia. J Refract Surg. 2008;24(3):294–9.PubMed Patel S, Alió JL, Feinbaum C. Comparison of Acri. Smart multifocal IOL, crystalens AT-45 accommodative IOL, and Technovision presbyLASIK for correcting presbyopia. J Refract Surg. 2008;24(3):294–9.PubMed
21.
go back to reference Karavitaki AE, Pallikaris IG, Panagopoulou SI, Kounis GA, Kontadakis G, Kymionis GD. Long-term visual outcomes after Crystalens® HD intraocular lens implantation. Clin Ophthalmol. 2014;8:937–43.CrossRefPubMedPubMedCentral Karavitaki AE, Pallikaris IG, Panagopoulou SI, Kounis GA, Kontadakis G, Kymionis GD. Long-term visual outcomes after Crystalens® HD intraocular lens implantation. Clin Ophthalmol. 2014;8:937–43.CrossRefPubMedPubMedCentral
22.
go back to reference Starck T, Liu Y, Prewett AL, Curup L G. Comparison of scotopic pupil measurement with slitlamp-based cobalt blue light and infrared video-based system. J Cataract Refract Surg. 2002;28(11):1952–6.CrossRefPubMed Starck T, Liu Y, Prewett AL, Curup L G. Comparison of scotopic pupil measurement with slitlamp-based cobalt blue light and infrared video-based system. J Cataract Refract Surg. 2002;28(11):1952–6.CrossRefPubMed
23.
go back to reference Chaglasian EL, Akbar S, Probst LE. Pupil measurement using the Colvard pupillometer and a standard pupil card with a cobalt blue filter penlight. J Cataract Refract Surg. 2006;32(2):255–60.CrossRefPubMed Chaglasian EL, Akbar S, Probst LE. Pupil measurement using the Colvard pupillometer and a standard pupil card with a cobalt blue filter penlight. J Cataract Refract Surg. 2006;32(2):255–60.CrossRefPubMed
24.
go back to reference PRODUCT INFORMATION. 6 month directions for use. AcrySof IQ ReSTOR multifocal IOL. Alcon Laboratories, Inc. 2009. www.alconsurgical.jp/pdfs/RES928.pdf PRODUCT INFORMATION. 6 month directions for use. AcrySof IQ ReSTOR multifocal IOL. Alcon Laboratories, Inc. 2009. www.alconsurgical.jp/pdfs/RES928.pdf
27.
go back to reference Neumann T. Theorie and operationstechnik der kapsulorhexis. Klein onatsbl Augenheilkd. 1987;190:542–5.CrossRef Neumann T. Theorie and operationstechnik der kapsulorhexis. Klein onatsbl Augenheilkd. 1987;190:542–5.CrossRef
28.
go back to reference Gimbel HV, Neumann T. Development, advantages and methods of the continuous circular capsulorhexis technique. J Cataract Refract Surg. 1993;16:31–7.CrossRef Gimbel HV, Neumann T. Development, advantages and methods of the continuous circular capsulorhexis technique. J Cataract Refract Surg. 1993;16:31–7.CrossRef
29.
go back to reference Souza CE, Muccioli C, Soriano ES, Chalita MR, Oliveira F, Freitas LL, et al. Visual performance of AcrySof ReSTOR apodized diffractive IOL: a prospective comparative trial. Am J Ophthalmol. 2006;141:827–32.CrossRefPubMed Souza CE, Muccioli C, Soriano ES, Chalita MR, Oliveira F, Freitas LL, et al. Visual performance of AcrySof ReSTOR apodized diffractive IOL: a prospective comparative trial. Am J Ophthalmol. 2006;141:827–32.CrossRefPubMed
30.
go back to reference Rossetti L, Carraro F, Rovati M, Orzalesi N. Performance of diffractive multifocal intraocular lenses in extracapsular cataract surgery. J Cataract Refract Surg. 1994;20:124–8.CrossRefPubMed Rossetti L, Carraro F, Rovati M, Orzalesi N. Performance of diffractive multifocal intraocular lenses in extracapsular cataract surgery. J Cataract Refract Surg. 1994;20:124–8.CrossRefPubMed
31.
go back to reference Blaylock JF, Si Z, Aitchison S, Prescott C. Visual function and change in quality of life after bilateral refractive lens exchange with the ReSTOR multifocal intraocular lens. J Refract Surg. 2008;24:265–73.PubMed Blaylock JF, Si Z, Aitchison S, Prescott C. Visual function and change in quality of life after bilateral refractive lens exchange with the ReSTOR multifocal intraocular lens. J Refract Surg. 2008;24:265–73.PubMed
32.
go back to reference Cochener B, Lafuma A, Khoshnood B, Courouve L, Berdeaux G. Comparison of outcomes with multifocal intraocular lenses: a meta analysis. Clin Ophthalmol. 2011;7(5):45–56. Cochener B, Lafuma A, Khoshnood B, Courouve L, Berdeaux G. Comparison of outcomes with multifocal intraocular lenses: a meta analysis. Clin Ophthalmol. 2011;7(5):45–56.
33.
go back to reference Mastropasqua R, Pedrotti E, Passilongo M, Parisi G, Marchesoni I, Marchini G. Long-term visual function and patient satisfaction after bilateral implantation and combination of two similar multifocal IOLs. J Refract Surg. 2015;31(5):308–14.CrossRefPubMed Mastropasqua R, Pedrotti E, Passilongo M, Parisi G, Marchesoni I, Marchini G. Long-term visual function and patient satisfaction after bilateral implantation and combination of two similar multifocal IOLs. J Refract Surg. 2015;31(5):308–14.CrossRefPubMed
34.
go back to reference Chang DH. Visual acuity and patient satisfaction at varied distances and lighting conditions after implantation of an aspheric diffractive multifocal one-piece intraocular lens. Clin Ophthalmol. 2016;10:1471–7.CrossRefPubMedPubMedCentral Chang DH. Visual acuity and patient satisfaction at varied distances and lighting conditions after implantation of an aspheric diffractive multifocal one-piece intraocular lens. Clin Ophthalmol. 2016;10:1471–7.CrossRefPubMedPubMedCentral
35.
go back to reference Leyland M, Pringle E. Multifocal versus monofocal intraocular lenses after cataract extraction. Cochrane Database Syst Rev. 2006;4:CD003169. Leyland M, Pringle E. Multifocal versus monofocal intraocular lenses after cataract extraction. Cochrane Database Syst Rev. 2006;4:CD003169.
36.
go back to reference Nakamura K, Bissen-Miyajima H, Yoshino M, Oki S. Visual performance after contralateral implantation of multifocal intraocular lenses with +3.0 and +4.0 diopter additions. Asia Pac J Ophthalmol (Phila). 2015;4(6):329–33.CrossRef Nakamura K, Bissen-Miyajima H, Yoshino M, Oki S. Visual performance after contralateral implantation of multifocal intraocular lenses with +3.0 and +4.0 diopter additions. Asia Pac J Ophthalmol (Phila). 2015;4(6):329–33.CrossRef
37.
go back to reference Cionni RJ, Osher RH, Snyder ME, Nordlund ML. Visual outcome comparison of unilateral versus bilateral implantation of apodized diffractive multifocal intraocular lenses after cataract extraction: prospective 6-month study. J Cataract Refract Surg. 2009;35(6):1033–9.CrossRefPubMed Cionni RJ, Osher RH, Snyder ME, Nordlund ML. Visual outcome comparison of unilateral versus bilateral implantation of apodized diffractive multifocal intraocular lenses after cataract extraction: prospective 6-month study. J Cataract Refract Surg. 2009;35(6):1033–9.CrossRefPubMed
38.
go back to reference Maxwell WA, Cionni RJ, Lehmann RP, Modi SS. Functional outcomes after bilateral implantation of apodized diffractive aspheric acrylic intraocular lenses with a +3.0 or +4.0 diopter addition power. Randomized multicenter clinical study. J Cataract Refract Surg. 2009;35:2054–61.CrossRefPubMed Maxwell WA, Cionni RJ, Lehmann RP, Modi SS. Functional outcomes after bilateral implantation of apodized diffractive aspheric acrylic intraocular lenses with a +3.0 or +4.0 diopter addition power. Randomized multicenter clinical study. J Cataract Refract Surg. 2009;35:2054–61.CrossRefPubMed
39.
go back to reference Mastropasqua L, Toto L, Falconio G, Nubile M, Carpineto P, Ciancaglini M, Di Nicola M, Ballone E. Long term results of 1 CU accommodative intraocular lens implantation: 2-year follow-up study. Acta Ophthalmol Scand. 2007;85:409–14.CrossRefPubMed Mastropasqua L, Toto L, Falconio G, Nubile M, Carpineto P, Ciancaglini M, Di Nicola M, Ballone E. Long term results of 1 CU accommodative intraocular lens implantation: 2-year follow-up study. Acta Ophthalmol Scand. 2007;85:409–14.CrossRefPubMed
40.
go back to reference Jacobi FK, Kammann J, Jacobi KW, Großkopf U, Walden K. Bilateral implantation of asymmetrical diffractive multifocal intraocular lenses. Arch Ophthalmol. 1999;117:17–23.CrossRefPubMed Jacobi FK, Kammann J, Jacobi KW, Großkopf U, Walden K. Bilateral implantation of asymmetrical diffractive multifocal intraocular lenses. Arch Ophthalmol. 1999;117:17–23.CrossRefPubMed
41.
go back to reference Alfonso JF, Fernández-Vega L, Señaris A, Montés-Micó R. Quality of vision with the Acri. Twin asymmetric diffractive bifocal intraocular lens system. J Cataract Refract Surg. 2007;33:197–202.CrossRefPubMed Alfonso JF, Fernández-Vega L, Señaris A, Montés-Micó R. Quality of vision with the Acri. Twin asymmetric diffractive bifocal intraocular lens system. J Cataract Refract Surg. 2007;33:197–202.CrossRefPubMed
42.
go back to reference Santhiago MR, Netto MV, Espindola RF, Mazurek MG, Gomes Bde A, Parede TR, et al. Comparison of reading performance after bilateral implantation of multifocal intraocular lenses with +3.00 or +4.00 diopter addition. J Cataract Refract Surg. 2010;36:1874–9.CrossRefPubMed Santhiago MR, Netto MV, Espindola RF, Mazurek MG, Gomes Bde A, Parede TR, et al. Comparison of reading performance after bilateral implantation of multifocal intraocular lenses with +3.00 or +4.00 diopter addition. J Cataract Refract Surg. 2010;36:1874–9.CrossRefPubMed
43.
go back to reference Mister U, Dillinger P, Anterist N, Kaymak H. Functional result with two multifocal intraocular lenses (MIOL). Array SA40 versus Acri. Twin. Opthalmogy. 2005;102:1051–6.CrossRef Mister U, Dillinger P, Anterist N, Kaymak H. Functional result with two multifocal intraocular lenses (MIOL). Array SA40 versus Acri. Twin. Opthalmogy. 2005;102:1051–6.CrossRef
44.
go back to reference Fernández-Vega L, Alfonso JF, Rodríguez PP, Montés-Micó R. Clear lens extraction with multifocal apodized diffractive intraocular lens implantation. Ophthalmology. 2007;114:1491–8.CrossRefPubMed Fernández-Vega L, Alfonso JF, Rodríguez PP, Montés-Micó R. Clear lens extraction with multifocal apodized diffractive intraocular lens implantation. Ophthalmology. 2007;114:1491–8.CrossRefPubMed
45.
go back to reference Fernández-Vega L, Alfonso JF, Baamonde MB, Montés-Micó R. Symmetric bilateral implantation of a distance-dominant diffractive bifocal intraocular lens. J Cataract Refract Surg. 2007;33:1913–7.CrossRefPubMed Fernández-Vega L, Alfonso JF, Baamonde MB, Montés-Micó R. Symmetric bilateral implantation of a distance-dominant diffractive bifocal intraocular lens. J Cataract Refract Surg. 2007;33:1913–7.CrossRefPubMed
46.
go back to reference Alfonso JF, Vega LF, Valcárcel B, Montés-Micó R. Visual performance after AcrySof ReSTOR aspheric intraocular lens implantation. J Optom. 2008;1:30–5.CrossRefPubMedCentral Alfonso JF, Vega LF, Valcárcel B, Montés-Micó R. Visual performance after AcrySof ReSTOR aspheric intraocular lens implantation. J Optom. 2008;1:30–5.CrossRefPubMedCentral
47.
go back to reference Blaylock JF, Si Z, Vickers C. Visual and refractive status at different focal distances after implantation of the ReSTOR multifocal intraocular lens. J Cataract Refract Surg. 2006;32:1464–73.CrossRefPubMed Blaylock JF, Si Z, Vickers C. Visual and refractive status at different focal distances after implantation of the ReSTOR multifocal intraocular lens. J Cataract Refract Surg. 2006;32:1464–73.CrossRefPubMed
48.
go back to reference De Vries NE, Webers CA, Montés-Micó R, Ferrer-Blasco T, Nuijts RM. Visual outcomes after cataract surgery with implantation of a +3.00 D or +4.00 D aspheric diffractive multifocal intraocular lens: Comparative study. J Cataract Refract Surg. 2010;36:1316–22.CrossRefPubMed De Vries NE, Webers CA, Montés-Micó R, Ferrer-Blasco T, Nuijts RM. Visual outcomes after cataract surgery with implantation of a +3.00 D or +4.00 D aspheric diffractive multifocal intraocular lens: Comparative study. J Cataract Refract Surg. 2010;36:1316–22.CrossRefPubMed
49.
go back to reference Kohnen T, Nuijts R, Levy P, Haefliger E, Alfonso JF. Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a +3.0 D addition. J Cataract Refract Surg. 2009;35:2062–9.CrossRefPubMed Kohnen T, Nuijts R, Levy P, Haefliger E, Alfonso JF. Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a +3.0 D addition. J Cataract Refract Surg. 2009;35:2062–9.CrossRefPubMed
50.
go back to reference Moreno LJ, Piñero DP, Alió JL, Fimia A, Plaza AB. Double-pass system analysis of the visual outcomes and optical performance of an apodized diffractive multifocal intraocular lens. J Cataract Refract Surg. 2010;36:2048–55.CrossRefPubMed Moreno LJ, Piñero DP, Alió JL, Fimia A, Plaza AB. Double-pass system analysis of the visual outcomes and optical performance of an apodized diffractive multifocal intraocular lens. J Cataract Refract Surg. 2010;36:2048–55.CrossRefPubMed
51.
go back to reference Hayashi K, Manabe S, Hayashi H. Visual acuity from far to near and contrast sensitivity in eyes with a diffractive multifocal intraocular lens with a low addition power. J Cataract Refract Surg. 2009;35:2070–6.CrossRefPubMed Hayashi K, Manabe S, Hayashi H. Visual acuity from far to near and contrast sensitivity in eyes with a diffractive multifocal intraocular lens with a low addition power. J Cataract Refract Surg. 2009;35:2070–6.CrossRefPubMed
52.
go back to reference Kohnen T, Allen D, Boureau C, Dublineau P, Hartmann C, Mehdorn E, et al. European multicenter study of the AcrySof ReSTOR apodized diffractive intraocular lens. Ophthalmology. 2006;113:578–84.CrossRef Kohnen T, Allen D, Boureau C, Dublineau P, Hartmann C, Mehdorn E, et al. European multicenter study of the AcrySof ReSTOR apodized diffractive intraocular lens. Ophthalmology. 2006;113:578–84.CrossRef
53.
go back to reference Lindstrom RL. Food and drug administration study update. Oneyear results from 671 patients with the 3 M multifocal intraocular lens. Ophthalmology. 1993;100:91–7.CrossRefPubMed Lindstrom RL. Food and drug administration study update. Oneyear results from 671 patients with the 3 M multifocal intraocular lens. Ophthalmology. 1993;100:91–7.CrossRefPubMed
54.
go back to reference Dick HB, Krummenauer F, Schwenn O, Krist R, Pfeiffer N. Objective and subjective evaluation of photic phenomena after monofocal and multifocal intraocular lens implantation. Ophthalmology. 1999;106:1878–86.CrossRefPubMed Dick HB, Krummenauer F, Schwenn O, Krist R, Pfeiffer N. Objective and subjective evaluation of photic phenomena after monofocal and multifocal intraocular lens implantation. Ophthalmology. 1999;106:1878–86.CrossRefPubMed
Metadata
Title
Comparison of visual outcomes, spectacles dependence and patient satisfaction of multifocal and accommodative intraocular lenses: innovative perspectives for maximal refractive-oriented cataract surgery
Authors
Raffaele Nuzzi
Federico Tridico
Publication date
01-12-2017
Publisher
BioMed Central
Published in
BMC Ophthalmology / Issue 1/2017
Electronic ISSN: 1471-2415
DOI
https://doi.org/10.1186/s12886-017-0411-9

Other articles of this Issue 1/2017

BMC Ophthalmology 1/2017 Go to the issue