Skip to main content
Top
Published in: BMC Anesthesiology 1/2015

Open Access 01-12-2015 | Research article

Effects of a fixed low-dose ropivacaine with different volume and concentrations on interscalene brachial plexus block: a randomized controlled trial

Authors: Wenwen Zhai, Xuedong Wang, Yulan Rong, Min Li, Hong Wang

Published in: BMC Anesthesiology | Issue 1/2015

Login to get access

Abstract

Background

Ultrasound guidance has reduced the amount of local anesthetics to achieve a successful block. Previous studies of the relationship between the volume or concentration of local anesthetics and the effects of the block were based on relatively high doses of local anesthetics. We tested the hypothesis that providing low dose of ropivacaine at three combinations of volumes and concentrations for ultrasound-guided interscalene brachial plexus block would produce different effects in the aspect of onset time, pain control and the incidence of side effects.

Methods

Ninety-nine patients undergoing elective arthroscopic shoulder surgery were randomized to receive an ultrasound guided combined with nerve stimulator mediated interscalene block with ropivacaine 0.75 % (6.7 ml, Group 0.75), 0.5 % (10 ml, Group 0.5) or 0.25 % (20 ml, Group 0.25). The primary end point was the onset time of the sensory blockade, assessed by using a pinprick in the C5-6 dermatome. The secondary end points included the onset time of the motor blockade, block success rate, postoperative pain rating score, rescue analgesics requirement, sleep quality, strength of the hand on the block side,and the incidence of hemi-diaphragmatic paresis which was evaluated by ultrasonography.

Results

There was a statistically significant difference of the sensory block median onset times among Group 0.75 (5 min), Group 0.5 (10 min) and Group 0.25 (20 min). One patient in Group 0.5 and 20 patients in Group 0.25 did not achieve a complete motor block within 30 min, which were also significantly different. No significant difference was observed in postoperative analgesia, decrease of handgrip strength and the incidence of hemi-diaphragmatic paresis among the 3 groups.

Conclusions

This study demonstrates that ropivacaine 50 mg as 0.25, 0.5 or 0.75 % solution for interscalene brachial plexus block before arthroscopic shoulder surgery produces comparable blockade with few side effects, while 0.75 % seems to be more preferable as it is associated with faster onset time.

Trial registration

ChiCTR-TRC-13004058. Registered 4 December 2013.
Literature
1.
go back to reference Hartrick CT, Tang YS, Siwek D, Murray R, Hunstad D, Smith G. The effect of initial local anesthetic dose with continuous interscalene analgesia on postoperative pain and diaphragmatic function in patients undergoing arthroscopic shoulder surgery: a double-blind, randomized controlled trial. BMC Anesthesiol. 2012;12:6.CrossRefPubMedPubMedCentral Hartrick CT, Tang YS, Siwek D, Murray R, Hunstad D, Smith G. The effect of initial local anesthetic dose with continuous interscalene analgesia on postoperative pain and diaphragmatic function in patients undergoing arthroscopic shoulder surgery: a double-blind, randomized controlled trial. BMC Anesthesiol. 2012;12:6.CrossRefPubMedPubMedCentral
2.
go back to reference Fredrickson MJ, Krishnan S, Chen CY. Postoperative analgesia for shoulder surgery: a critical appraisal and review of current techniques. Anaesthesia. 2010;65:608–24.CrossRefPubMed Fredrickson MJ, Krishnan S, Chen CY. Postoperative analgesia for shoulder surgery: a critical appraisal and review of current techniques. Anaesthesia. 2010;65:608–24.CrossRefPubMed
3.
go back to reference Renes SH, van Geffen GJ, Rettig HC, Gielen MJ, Scheffer GJ. Minimum effective volume of local anesthetic for shoulder analgesia by ultrasound-guided block at root C7 with assessment of pulmonary function. Reg Anesth Pain Med. 2010;35(6):529–34.CrossRefPubMed Renes SH, van Geffen GJ, Rettig HC, Gielen MJ, Scheffer GJ. Minimum effective volume of local anesthetic for shoulder analgesia by ultrasound-guided block at root C7 with assessment of pulmonary function. Reg Anesth Pain Med. 2010;35(6):529–34.CrossRefPubMed
4.
go back to reference Riazi S, Carmichael N, Awad I, Holtby RM, McCartney CJ. Effect of local anaesthetic volume (20 vs 5 ml) on the efficacy and respiratory consequences of ultrasound-guided interscalene brachial plexus block. Br J Anaesth. 2008;101:549–56.CrossRefPubMed Riazi S, Carmichael N, Awad I, Holtby RM, McCartney CJ. Effect of local anaesthetic volume (20 vs 5 ml) on the efficacy and respiratory consequences of ultrasound-guided interscalene brachial plexus block. Br J Anaesth. 2008;101:549–56.CrossRefPubMed
5.
go back to reference Krone SC, Chan VW, Regan J, Peng P, Poate EM, McCartney C, et al. Analgesic effects of low-dose ropivacaine for interscalene brachial plexus block for outpatient shoulder surgery-a dose-finding study. Reg Anesth Pain Med. 2001;26:439–43.CrossRefPubMed Krone SC, Chan VW, Regan J, Peng P, Poate EM, McCartney C, et al. Analgesic effects of low-dose ropivacaine for interscalene brachial plexus block for outpatient shoulder surgery-a dose-finding study. Reg Anesth Pain Med. 2001;26:439–43.CrossRefPubMed
6.
go back to reference Cappelleri G, Ambrosoli AL, Turconi S, Gemma M, Ricci EB, Cornaggia G. Effect of local anesthetic dilution on the onset time and duration of double-injection sciatic nerve block: a prospective, randomized, blinded evaluation. Anesth Analg. 2014;119:489–93.CrossRefPubMed Cappelleri G, Ambrosoli AL, Turconi S, Gemma M, Ricci EB, Cornaggia G. Effect of local anesthetic dilution on the onset time and duration of double-injection sciatic nerve block: a prospective, randomized, blinded evaluation. Anesth Analg. 2014;119:489–93.CrossRefPubMed
7.
go back to reference Taboada Muniz M, Rodriguez J, Bermudez M, Valino C, Blanco N, Amor M, et al. Low volume and high concentration of local anesthetic is more efficacious than high volume and low concentration in Labat’s sciatic nerve block: a prospective, randomized comparison. Anesth Analg. 2008;107:2085–8.CrossRefPubMed Taboada Muniz M, Rodriguez J, Bermudez M, Valino C, Blanco N, Amor M, et al. Low volume and high concentration of local anesthetic is more efficacious than high volume and low concentration in Labat’s sciatic nerve block: a prospective, randomized comparison. Anesth Analg. 2008;107:2085–8.CrossRefPubMed
8.
go back to reference Gonzalez AP, Bernucci F, Techasuk W, Pham K, Finlayson RJ, de Tran QH. A randomized comparison between 3 combinations of volume and concentration of lidocaine for ultrasound-guided infraclavicular block. Reg Anesth Pain Med. 2013;38:206–11.CrossRefPubMed Gonzalez AP, Bernucci F, Techasuk W, Pham K, Finlayson RJ, de Tran QH. A randomized comparison between 3 combinations of volume and concentration of lidocaine for ultrasound-guided infraclavicular block. Reg Anesth Pain Med. 2013;38:206–11.CrossRefPubMed
9.
go back to reference Bertini L, Palmisani S, Mancini S, Martini O, Ioculano R, Arcioni R. Does local anesthetic dilution influence the clinical effectiveness of multiple-injection axillary brachial plexus block?: a prospective, double-blind, randomized clinical trial in patients undergoing upper limb surgery. Reg Anesth Pain Med. 2009;34:408–13.CrossRefPubMed Bertini L, Palmisani S, Mancini S, Martini O, Ioculano R, Arcioni R. Does local anesthetic dilution influence the clinical effectiveness of multiple-injection axillary brachial plexus block?: a prospective, double-blind, randomized clinical trial in patients undergoing upper limb surgery. Reg Anesth Pain Med. 2009;34:408–13.CrossRefPubMed
10.
go back to reference Krenn H, Deusch E, Balogh B, Jellinek H, Oczenski W, Plainer-Zochling E, et al. Increasing the injection volume by dilution improves the onset of motor blockade, but not sensory blockade of ropivacaine for brachial plexus block. Eur J Anaesthesiol. 2003;20:21–5.CrossRefPubMed Krenn H, Deusch E, Balogh B, Jellinek H, Oczenski W, Plainer-Zochling E, et al. Increasing the injection volume by dilution improves the onset of motor blockade, but not sensory blockade of ropivacaine for brachial plexus block. Eur J Anaesthesiol. 2003;20:21–5.CrossRefPubMed
11.
go back to reference Nunez Aguado D, Lopez Alvarez S, Salamanca Montana ME, Janeiro Amela M, Fernandez Fernandez R, Cobian Llamas JM. Brachial plexus block with levobupivacaine at the humeral canal: comparison of a small volume at high concentration with a large volume at low concentration. Rev Esp Anestesiol Reanim. 2005;52:529–35.PubMed Nunez Aguado D, Lopez Alvarez S, Salamanca Montana ME, Janeiro Amela M, Fernandez Fernandez R, Cobian Llamas JM. Brachial plexus block with levobupivacaine at the humeral canal: comparison of a small volume at high concentration with a large volume at low concentration. Rev Esp Anestesiol Reanim. 2005;52:529–35.PubMed
12.
go back to reference Markham A, Faulds D. Ropivacaine. A review of its pharmacology and therapeutic use in regional anaesthesia. Drugs. 1996;52:429–49.CrossRefPubMed Markham A, Faulds D. Ropivacaine. A review of its pharmacology and therapeutic use in regional anaesthesia. Drugs. 1996;52:429–49.CrossRefPubMed
13.
go back to reference Orebaugh SL, Williams BA. Brachial plexus anatomy: normal and variant. Sci World J. 2009;9:300–12.CrossRef Orebaugh SL, Williams BA. Brachial plexus anatomy: normal and variant. Sci World J. 2009;9:300–12.CrossRef
14.
go back to reference Thackeray EM, Swenson JD, Gertsch MC, Phillips KM, Steele JW, Burks RT, et al. Diaphragm function after interscalene brachial plexus block: a double-blind, randomized comparison of 0.25 % and 0.125 % bupivacaine. J Shoulder Elbow Surg. 2013;22:381–6.CrossRefPubMed Thackeray EM, Swenson JD, Gertsch MC, Phillips KM, Steele JW, Burks RT, et al. Diaphragm function after interscalene brachial plexus block: a double-blind, randomized comparison of 0.25 % and 0.125 % bupivacaine. J Shoulder Elbow Surg. 2013;22:381–6.CrossRefPubMed
15.
go back to reference Al-Kaisy AA, Chan VW, Perlas A. Respiratory effects of low-dose bupivacaine interscalene block. Br J Anaesth. 1999;82:217–20.CrossRefPubMed Al-Kaisy AA, Chan VW, Perlas A. Respiratory effects of low-dose bupivacaine interscalene block. Br J Anaesth. 1999;82:217–20.CrossRefPubMed
16.
go back to reference Lee JH, Cho SH, Kim SH, Chae WS, Jin HC, Lee JS, et al. Ropivacaine for ultrasound-guided interscalene block: 5 mL provides similar analgesia but less phrenic nerve paralysis than 10 mL. Can J Anaesth. 2011;58:1001–6.CrossRefPubMed Lee JH, Cho SH, Kim SH, Chae WS, Jin HC, Lee JS, et al. Ropivacaine for ultrasound-guided interscalene block: 5 mL provides similar analgesia but less phrenic nerve paralysis than 10 mL. Can J Anaesth. 2011;58:1001–6.CrossRefPubMed
17.
go back to reference Renes SH, Rettig HC, Gielen MJ, Wilder-Smith OH, van Geffen GJ. Ultrasound-guided low-dose interscalene brachial plexus block reduces the incidence of hemidiaphragmatic paresis. Reg Anesth Pain Med. 2009;34:498–502.CrossRefPubMed Renes SH, Rettig HC, Gielen MJ, Wilder-Smith OH, van Geffen GJ. Ultrasound-guided low-dose interscalene brachial plexus block reduces the incidence of hemidiaphragmatic paresis. Reg Anesth Pain Med. 2009;34:498–502.CrossRefPubMed
18.
go back to reference Kaye AD, Urman RD, Vadivelu N. Essentials of Regional Anesthesia. 1st ed. New York: Springer; 2012.CrossRef Kaye AD, Urman RD, Vadivelu N. Essentials of Regional Anesthesia. 1st ed. New York: Springer; 2012.CrossRef
19.
go back to reference Hanson NA, Auyong DB. Systematic ultrasound identification of the dorsal scapular and long thoracic nerves during interscalene block. Reg Anesth Pain Med. 2013;38(1):54–7.CrossRefPubMed Hanson NA, Auyong DB. Systematic ultrasound identification of the dorsal scapular and long thoracic nerves during interscalene block. Reg Anesth Pain Med. 2013;38(1):54–7.CrossRefPubMed
Metadata
Title
Effects of a fixed low-dose ropivacaine with different volume and concentrations on interscalene brachial plexus block: a randomized controlled trial
Authors
Wenwen Zhai
Xuedong Wang
Yulan Rong
Min Li
Hong Wang
Publication date
01-12-2015
Publisher
BioMed Central
Published in
BMC Anesthesiology / Issue 1/2015
Electronic ISSN: 1471-2253
DOI
https://doi.org/10.1186/s12871-016-0248-4

Other articles of this Issue 1/2015

BMC Anesthesiology 1/2015 Go to the issue