Skip to main content
Top
Published in: Critical Care 6/2006

Open Access 01-12-2006 | Research

Pulmonary artery catheter versus pulse contour analysis: a prospective epidemiological study

Authors: Shigehiko Uchino, Rinaldo Bellomo, Hiroshi Morimatsu, Makoto Sugihara, Craig French, Dianne Stephens, Julia Wendon, Patrick Honore, John Mulder, Andrew Turner, the PAC/PiCCO Use and Likelihood of Success Evaluation [PULSE] Study Group

Published in: Critical Care | Issue 6/2006

Login to get access

Abstract

Introduction

The choice of invasive systemic haemodynamic monitoring in critically ill patients remains controversial as no multicentre comparative clinical data exist. Accordingly, we sought to study and compare the features and outcomes of patients who receive haemodynamic monitoring with either the pulmonary artery catheter (PAC) or pulse contour cardiac output (PiCCO) technology.

Methods

We conducted a prospective multicentre, multinational epidemiological study in a cohort of 331 critically ill patients who received haemodynamic monitoring by PAC or PiCCO according to physician preference in intensive care units (ICUs) of eight hospitals in four countries. We collected data on haemodynamics, demographic features, daily fluid balance, mechanical ventilation days, ICU days, hospital days, and hospital mortality. We statistically compared the two techniques.

Results

Three hundred and forty-two catheters (PiCCO 192 and PAC 150) were inserted in 331 patients. On direct comparison, patients with PAC were older (68 versus 64 years of age; p = 0.0037), were given inotropic drugs more frequently (37.3% versus 13%; p < 0.0001), and had a lower cardiac index (2.6 versus 3.2 litres/minute per square meter; p < 0.0001). Mean daily fluid balance was significantly greater during PiCCO monitoring (+659 versus +350 ml/day; p = 0.017) and mechanical ventilation-free days were fewer (12 for PiCCO versus 21 for PAC; p = 0.045). However, after multiple regression analysis, we found no significant effect of monitoring technique on mean daily fluid balance, mechanical ventilation-free days, ICU-free days, or hospital mortality. A secondary multiple logistic regression analysis for hospital mortality which included mean daily fluid balance showed that positive fluid balance was a significant predictor of hospital mortality (odds ratio = 1.0002 for each ml/day; p = 0.0073).

Conclusion

On direct comparison, the use of PiCCO was associated with a greater positive fluid balance and fewer ventilator-free days. After correction for confounding factors, the choice of monitoring did not influence major outcomes, whereas a positive fluid balance was a significant independent predictor of outcome. Future studies may best be targeted at understanding the effect of pursuing different fluid balance regimens rather than monitoring techniques per se.
Appendix
Available only for authorised users
Literature
1.
go back to reference Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D: Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med. 1970, 283: 447-451.CrossRefPubMed Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D: Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med. 1970, 283: 447-451.CrossRefPubMed
2.
go back to reference Polanczyk CA, Rohde LE, Goldman L, Cook EF, Thomas EJ, Marcantonio ER, Mangione CM, Lee TH: Right heart catheterization and cardiac complications in patients undergoing noncardiac surgery: an observational study. JAMA. 2001, 286: 309-314. 10.1001/jama.286.3.309.CrossRefPubMed Polanczyk CA, Rohde LE, Goldman L, Cook EF, Thomas EJ, Marcantonio ER, Mangione CM, Lee TH: Right heart catheterization and cardiac complications in patients undergoing noncardiac surgery: an observational study. JAMA. 2001, 286: 309-314. 10.1001/jama.286.3.309.CrossRefPubMed
3.
go back to reference Rhodes A, Cusack RJ, Newman PJ, Grounds RM, Bennett ED: A randomised, controlled trial of the pulmonary artery catheter in critically ill patients. Intensive Care Med. 2002, 28: 256-264. 10.1007/s00134-002-1206-9.CrossRefPubMed Rhodes A, Cusack RJ, Newman PJ, Grounds RM, Bennett ED: A randomised, controlled trial of the pulmonary artery catheter in critically ill patients. Intensive Care Med. 2002, 28: 256-264. 10.1007/s00134-002-1206-9.CrossRefPubMed
4.
go back to reference Sandham JD, Hull RD, Brant RF, Knox L, Pineo GF, Doig CJ, Laporta DP, Viner S, Passerini L, Devitt H, et al: A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med. 2003, 348: 5-14. 10.1056/NEJMoa021108.CrossRefPubMed Sandham JD, Hull RD, Brant RF, Knox L, Pineo GF, Doig CJ, Laporta DP, Viner S, Passerini L, Devitt H, et al: A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med. 2003, 348: 5-14. 10.1056/NEJMoa021108.CrossRefPubMed
5.
go back to reference Sakka SG, Ruhl CC, Pfeiffer UJ, Beale R, McLuckie A, Reinhart K, Meier-Hellmann A: Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution. Intensive Care Med. 2000, 26: 180-187. 10.1007/s001340050043.CrossRefPubMed Sakka SG, Ruhl CC, Pfeiffer UJ, Beale R, McLuckie A, Reinhart K, Meier-Hellmann A: Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution. Intensive Care Med. 2000, 26: 180-187. 10.1007/s001340050043.CrossRefPubMed
6.
go back to reference Wiesenack C, Prasser C, Keyl C, Rodijg G: Assessment of intrathoracic blood volume as an indicator of cardiac preload: single transpulmonary thermodilution technique versus assessment of pressure preload parameters derived from a pulmonary artery catheter. J Cardiothorac Vasc Anesth. 2001, 15: 584-588. 10.1053/jcan.2001.26536.CrossRefPubMed Wiesenack C, Prasser C, Keyl C, Rodijg G: Assessment of intrathoracic blood volume as an indicator of cardiac preload: single transpulmonary thermodilution technique versus assessment of pressure preload parameters derived from a pulmonary artery catheter. J Cardiothorac Vasc Anesth. 2001, 15: 584-588. 10.1053/jcan.2001.26536.CrossRefPubMed
7.
go back to reference Della Rocca G, Costa GM, Coccia C, Pompei L, Di Marco P, Pietropaoli P: Preload index: pulmonary artery occlusion pressure versus intrathoracic blood volume monitoring during lung transplantation. Anesth Analg. 2002, 95: 835-843. 10.1097/00000539-200210000-00009.PubMed Della Rocca G, Costa GM, Coccia C, Pompei L, Di Marco P, Pietropaoli P: Preload index: pulmonary artery occlusion pressure versus intrathoracic blood volume monitoring during lung transplantation. Anesth Analg. 2002, 95: 835-843. 10.1097/00000539-200210000-00009.PubMed
8.
go back to reference Godje O, Peyerl M, Seebauer T, Lamm P, Mair H, Reichart B: Central venous pressure, pulmonary capillary wedge pressure and intrathoracic blood volumes as preload indicators in cardiac surgery patients. Eur J Cardiothorac Surg. 1998, 13: 533-539. 10.1016/S1010-7940(98)00063-3.CrossRefPubMed Godje O, Peyerl M, Seebauer T, Lamm P, Mair H, Reichart B: Central venous pressure, pulmonary capillary wedge pressure and intrathoracic blood volumes as preload indicators in cardiac surgery patients. Eur J Cardiothorac Surg. 1998, 13: 533-539. 10.1016/S1010-7940(98)00063-3.CrossRefPubMed
9.
go back to reference Lichtwarck-Aschoff M, Beale R, Pfeiffer UJ: Central venous pressure, pulmonary artery occlusion pressure, intrathoracic blood volume, and right ventricular end-diastolic volume as indicators of cardiac preload. J Crit Care. 1996, 11: 180-188. 10.1016/S0883-9441(96)90029-5.CrossRefPubMed Lichtwarck-Aschoff M, Beale R, Pfeiffer UJ: Central venous pressure, pulmonary artery occlusion pressure, intrathoracic blood volume, and right ventricular end-diastolic volume as indicators of cardiac preload. J Crit Care. 1996, 11: 180-188. 10.1016/S0883-9441(96)90029-5.CrossRefPubMed
10.
go back to reference Lichtwarck-Aschoff M, Zeravik J, Pfeiffer UJ: Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilation. Intensive Care Med. 1992, 18: 142-147. 10.1007/BF01709237.CrossRefPubMed Lichtwarck-Aschoff M, Zeravik J, Pfeiffer UJ: Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilation. Intensive Care Med. 1992, 18: 142-147. 10.1007/BF01709237.CrossRefPubMed
11.
go back to reference Mitchell JP, Schuller D, Calandrino FS, Schuster DP: Improved outcome based on fluid management in critically ill patients requiring pulmonary artery catheterization. Am Rev Respir Dis. 1992, 145: 990-998.CrossRefPubMed Mitchell JP, Schuller D, Calandrino FS, Schuster DP: Improved outcome based on fluid management in critically ill patients requiring pulmonary artery catheterization. Am Rev Respir Dis. 1992, 145: 990-998.CrossRefPubMed
12.
go back to reference Le Gall JR, Lemeshow S, Saulnier F: A new simplified acute physiology score (SAPS-II) based on a European/North American multicenter study. JAMA. 1993, 270: 2957-2963. 10.1001/jama.270.24.2957.CrossRefPubMed Le Gall JR, Lemeshow S, Saulnier F: A new simplified acute physiology score (SAPS-II) based on a European/North American multicenter study. JAMA. 1993, 270: 2957-2963. 10.1001/jama.270.24.2957.CrossRefPubMed
13.
go back to reference Bellomo R, Uchino S: Cardiovascular monitoring tools: use and misuse. Curr Opin Crit Care. 2003, 9: 225-229. 10.1097/00075198-200306000-00010.CrossRefPubMed Bellomo R, Uchino S: Cardiovascular monitoring tools: use and misuse. Curr Opin Crit Care. 2003, 9: 225-229. 10.1097/00075198-200306000-00010.CrossRefPubMed
14.
go back to reference Sakka SG, Klein M, Reinhart K, Meier-Hellmann A: Prognostic value of extravascular lung water in critically ill patients. Chest. 2002, 122: 2080-2086. 10.1378/chest.122.6.2080.CrossRefPubMed Sakka SG, Klein M, Reinhart K, Meier-Hellmann A: Prognostic value of extravascular lung water in critically ill patients. Chest. 2002, 122: 2080-2086. 10.1378/chest.122.6.2080.CrossRefPubMed
15.
go back to reference Alsous F, Khamiees M, DeGirolamo A, Amoateng-Adjepong Y, Manthous CA: Negative fluid balance predicts survival in patients with septic shock: a retrospective pilot study. Chest. 2000, 117: 1749-1754. 10.1378/chest.117.6.1749.CrossRefPubMed Alsous F, Khamiees M, DeGirolamo A, Amoateng-Adjepong Y, Manthous CA: Negative fluid balance predicts survival in patients with septic shock: a retrospective pilot study. Chest. 2000, 117: 1749-1754. 10.1378/chest.117.6.1749.CrossRefPubMed
16.
go back to reference Schuller D, Mitchell JP, Calandrino FS, Schuster DP: Fluid balance during pulmonary edema. Is fluid gain a marker or a cause of poor outcome?. Chest. 1991, 100: 1068-1075.CrossRefPubMed Schuller D, Mitchell JP, Calandrino FS, Schuster DP: Fluid balance during pulmonary edema. Is fluid gain a marker or a cause of poor outcome?. Chest. 1991, 100: 1068-1075.CrossRefPubMed
17.
go back to reference Kula R, Szturz P, Sklienka P, Neiser J, Jahoda J: A role for negative fluid balance in septic patients with abdominal compartment syndrome?. Intensive Care Med. 2004, 30: 2138-2139. 10.1007/s00134-004-2423-1.CrossRefPubMed Kula R, Szturz P, Sklienka P, Neiser J, Jahoda J: A role for negative fluid balance in septic patients with abdominal compartment syndrome?. Intensive Care Med. 2004, 30: 2138-2139. 10.1007/s00134-004-2423-1.CrossRefPubMed
18.
go back to reference Bickell WH, Wall MJ, Pepe PE, Martin RR, Ginger VF, Allen MK, Mattox KL: Immediate versus delayed fluid resuscitation for hypotensive patients with penetrating torso injuries. N Engl J Med. 1994, 331: 1105-1109. 10.1056/NEJM199410273311701.CrossRefPubMed Bickell WH, Wall MJ, Pepe PE, Martin RR, Ginger VF, Allen MK, Mattox KL: Immediate versus delayed fluid resuscitation for hypotensive patients with penetrating torso injuries. N Engl J Med. 1994, 331: 1105-1109. 10.1056/NEJM199410273311701.CrossRefPubMed
19.
go back to reference Jones RM, Moulton CE, Hardy KJ: Central venous pressure and its effect on blood loss during liver resection. Br J Surg. 1998, 85: 1058-1060. 10.1046/j.1365-2168.1998.00795.x.CrossRefPubMed Jones RM, Moulton CE, Hardy KJ: Central venous pressure and its effect on blood loss during liver resection. Br J Surg. 1998, 85: 1058-1060. 10.1046/j.1365-2168.1998.00795.x.CrossRefPubMed
20.
go back to reference Lobo DN, Bostock KA, Neal KR, Perkins AC, Rowlands BJ, Allison SP: Effect of salt and water balance on recovery of gastrointestinal function after elective colonic resection: a randomised controlled trial. Lancet. 2002, 359: 1812-1818. 10.1016/S0140-6736(02)08711-1.CrossRefPubMed Lobo DN, Bostock KA, Neal KR, Perkins AC, Rowlands BJ, Allison SP: Effect of salt and water balance on recovery of gastrointestinal function after elective colonic resection: a randomised controlled trial. Lancet. 2002, 359: 1812-1818. 10.1016/S0140-6736(02)08711-1.CrossRefPubMed
21.
go back to reference Lopez A, Lorente JA, Steingrub J, Bakker J, McLuckie A, Willatts S, Brockway M, Anzueto A, Holzapfel L, Breen D, et al: Multiple-center, randomized, placebo-controlled, double-blind study of the nitric oxide synthase inhibitor 546C88: effect on survival in patients with septic shock. Crit Care Med. 2004, 32: 21-30. 10.1097/01.CCM.0000105581.01815.C6.CrossRefPubMed Lopez A, Lorente JA, Steingrub J, Bakker J, McLuckie A, Willatts S, Brockway M, Anzueto A, Holzapfel L, Breen D, et al: Multiple-center, randomized, placebo-controlled, double-blind study of the nitric oxide synthase inhibitor 546C88: effect on survival in patients with septic shock. Crit Care Med. 2004, 32: 21-30. 10.1097/01.CCM.0000105581.01815.C6.CrossRefPubMed
22.
go back to reference The Acute Respiratory Distress Syndrome Network: Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000, 342: 1301-1308. 10.1056/NEJM200005043421801.CrossRef The Acute Respiratory Distress Syndrome Network: Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000, 342: 1301-1308. 10.1056/NEJM200005043421801.CrossRef
23.
go back to reference Jacquet L, Honore P, Beale R, Valadi D, Dion R, Goenen M: Cardiac function after intermittent antegrade warm blood cardioplegia: contribution of the double-indicator dilution technique. Intensive Care Med. 2000, 26: 686-692. 10.1007/s001340051233.CrossRefPubMed Jacquet L, Honore P, Beale R, Valadi D, Dion R, Goenen M: Cardiac function after intermittent antegrade warm blood cardioplegia: contribution of the double-indicator dilution technique. Intensive Care Med. 2000, 26: 686-692. 10.1007/s001340051233.CrossRefPubMed
24.
go back to reference Wiesenack C, Fiegl C, Keyser A, Prasser C, Key C: Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients. Eur J Anesthesiol. 2005, 22: 658-665. 10.1017/S0265021505001092.CrossRef Wiesenack C, Fiegl C, Keyser A, Prasser C, Key C: Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients. Eur J Anesthesiol. 2005, 22: 658-665. 10.1017/S0265021505001092.CrossRef
25.
go back to reference Hofer CK, Mueller SM, Furrer L, Klaghofer R, Genoni M, Zollinger A: Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest. 2005, 128: 848-854. 10.1378/chest.128.2.848.CrossRefPubMed Hofer CK, Mueller SM, Furrer L, Klaghofer R, Genoni M, Zollinger A: Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest. 2005, 128: 848-854. 10.1378/chest.128.2.848.CrossRefPubMed
Metadata
Title
Pulmonary artery catheter versus pulse contour analysis: a prospective epidemiological study
Authors
Shigehiko Uchino
Rinaldo Bellomo
Hiroshi Morimatsu
Makoto Sugihara
Craig French
Dianne Stephens
Julia Wendon
Patrick Honore
John Mulder
Andrew Turner
the PAC/PiCCO Use and Likelihood of Success Evaluation [PULSE] Study Group
Publication date
01-12-2006
Publisher
BioMed Central
Published in
Critical Care / Issue 6/2006
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc5126

Other articles of this Issue 6/2006

Critical Care 6/2006 Go to the issue