Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? A case report

Authors: Michael T Hirschmann, Tom Adler, Helmut Rasch, Rolf W Hügli, Niklaus F Friederich, Markus P Arnold

Published in: BMC Sports Science, Medicine and Rehabilitation | Issue 1/2010

Login to get access

Abstract

With the presented case we strive to introduce combined single photon emission computerized tomography and conventional computer tomography (SPECT/CT) as new diagnostic imaging modality and illustrate the possible clinical value in patients after ACL reconstruction. We report the case of a painful knee due to a foreign body reaction and delayed degradation of the biodegradable interference screws after ACL reconstruction. The MRI showed an intact ACL graft, a possible tibial cyclops lesion and a patella infera. There was no increased fluid collection within the bone tunnels. The 99mTc-HDP-SPECT/CT clearly identified a highly increased tracer uptake around and within the tibial and femoral tunnels and the patellofemoral joint. On 3D-CT out of the SPECT/CT data the femoral graft attachment was shallow (50% along the Blumensaat's line) and high in the notch. At revision arthroscopy a diffuse hypertrophy of the synovium, scarring of the Hoffa fat pad and a cyclops lesion of the former ACL graft was found. The interference screws were partially degraded and under palpation and pressure a grey fluid-like substance drained into the joint. The interference screws and the ACL graft were removed and an arthrolysis performed.
In the case presented it was most likely a combination of improper graft placement, delayed degradation of the interference screws and unknown biological factors. The too shallow and high ACL graft placement might have led to roof impingement, chronic intraarticular inflammation and hence the delayed degradation of the screws.
SPECT/CT has facilitated the establishment of diagnosis, process of decision making and further treatment in patients with knee pain after ACL reconstruction. From the combination of structural (tunnel position in 3D-CT) and metabolic information (tracer uptake in SPECT/CT) the patient's cause of the pain was established.
Appendix
Available only for authorised users
Literature
1.
go back to reference Frosch KH, Sawallich T, Schutze G, Losch A, Walde T, Balcarek P, Konietschke F, Sturmer KM: Magnetic resonance imaging analysis of the bioabsorbable Milagro interference screw for graft fixation in anterior cruciate ligament reconstruction. Strategies Trauma Limb Reconstr. 2009, 4 (2): 73-79. 10.1007/s11751-009-0063-2.CrossRefPubMedPubMedCentral Frosch KH, Sawallich T, Schutze G, Losch A, Walde T, Balcarek P, Konietschke F, Sturmer KM: Magnetic resonance imaging analysis of the bioabsorbable Milagro interference screw for graft fixation in anterior cruciate ligament reconstruction. Strategies Trauma Limb Reconstr. 2009, 4 (2): 73-79. 10.1007/s11751-009-0063-2.CrossRefPubMedPubMedCentral
2.
go back to reference Zheng N, Price CT, Indelicato PA, Gao B: Tibial fixation of bone-patellar tendon-bone grafts in anterior cruciate ligament reconstruction: a cadaveric study of bovine bone screw and biodegradable interference screw. Am J Sports Med. 2008, 36 (12): 2322-2327. 10.1177/0363546508322895.CrossRefPubMed Zheng N, Price CT, Indelicato PA, Gao B: Tibial fixation of bone-patellar tendon-bone grafts in anterior cruciate ligament reconstruction: a cadaveric study of bovine bone screw and biodegradable interference screw. Am J Sports Med. 2008, 36 (12): 2322-2327. 10.1177/0363546508322895.CrossRefPubMed
3.
go back to reference Kwak JH, Sim JA, Kim SH, Lee KC, Lee BK: Delayed intra-articular inflammatory reaction due to poly-L-lactide bioabsorbable interference screw used in anterior cruciate ligament reconstruction. Arthroscopy. 2008, 24 (2): 243-246. 10.1016/j.arthro.2007.11.012.CrossRefPubMed Kwak JH, Sim JA, Kim SH, Lee KC, Lee BK: Delayed intra-articular inflammatory reaction due to poly-L-lactide bioabsorbable interference screw used in anterior cruciate ligament reconstruction. Arthroscopy. 2008, 24 (2): 243-246. 10.1016/j.arthro.2007.11.012.CrossRefPubMed
4.
go back to reference Jarvela T, Moisala AS, Sihvonen R, Jarvela S, Kannus P, Jarvinen M: Double-bundle anterior cruciate ligament reconstruction using hamstring autografts and bioabsorbable interference screw fixation: prospective, randomized, clinical study with 2-year results. Am J Sports Med. 2008, 36 (2): 290-297. 10.1177/0363546507308360.CrossRefPubMed Jarvela T, Moisala AS, Sihvonen R, Jarvela S, Kannus P, Jarvinen M: Double-bundle anterior cruciate ligament reconstruction using hamstring autografts and bioabsorbable interference screw fixation: prospective, randomized, clinical study with 2-year results. Am J Sports Med. 2008, 36 (2): 290-297. 10.1177/0363546507308360.CrossRefPubMed
5.
go back to reference Herbenick M, Gambardella R: Revision anterior cruciate ligament reconstruction using a unique bioabsorbable interference screw for malpositioned tunnels. Am J Orthop (Belle Mead NJ). 2008, 37 (8): 425-428. Herbenick M, Gambardella R: Revision anterior cruciate ligament reconstruction using a unique bioabsorbable interference screw for malpositioned tunnels. Am J Orthop (Belle Mead NJ). 2008, 37 (8): 425-428.
6.
go back to reference Zantop T, Weimann A, Wolle K, Musahl V, Langer M, Petersen W: Initial and 6 weeks postoperative structural properties of soft tissue anterior cruciate ligament reconstructions with cross-pin or interference screw fixation: an in vivo study in sheep. Arthroscopy. 2007, 23 (1): 14-20. 10.1016/j.arthro.2006.10.007.CrossRefPubMed Zantop T, Weimann A, Wolle K, Musahl V, Langer M, Petersen W: Initial and 6 weeks postoperative structural properties of soft tissue anterior cruciate ligament reconstructions with cross-pin or interference screw fixation: an in vivo study in sheep. Arthroscopy. 2007, 23 (1): 14-20. 10.1016/j.arthro.2006.10.007.CrossRefPubMed
7.
go back to reference Park MC, Tibone JE: False magnetic resonance imaging persistence of a biodegradable anterior cruciate ligament interference screw with chronic inflammation after 4 years in vivo. Arthroscopy. 2006, 22 (8): 911-e911-914.PubMed Park MC, Tibone JE: False magnetic resonance imaging persistence of a biodegradable anterior cruciate ligament interference screw with chronic inflammation after 4 years in vivo. Arthroscopy. 2006, 22 (8): 911-e911-914.PubMed
8.
go back to reference Sanchis-Alfonso V, Tinto-Pedrerol M: Femoral interference screw divergence after anterior cruciate ligament reconstruction provoking severe anterior knee pain. Arthroscopy. 2004, 20 (5): 528-531. 10.1016/j.arthro.2004.03.011.CrossRefPubMed Sanchis-Alfonso V, Tinto-Pedrerol M: Femoral interference screw divergence after anterior cruciate ligament reconstruction provoking severe anterior knee pain. Arthroscopy. 2004, 20 (5): 528-531. 10.1016/j.arthro.2004.03.011.CrossRefPubMed
9.
go back to reference Morgan CD, Gehrmann RM, Jayo MJ, Johnson CS: Histologic findings with a bioabsorbable anterior cruciate ligament interference screw explant after 2.5 years in vivo. Arthroscopy. 2002, 18 (9): E47-10.1053/jars.2002.36466.CrossRefPubMed Morgan CD, Gehrmann RM, Jayo MJ, Johnson CS: Histologic findings with a bioabsorbable anterior cruciate ligament interference screw explant after 2.5 years in vivo. Arthroscopy. 2002, 18 (9): E47-10.1053/jars.2002.36466.CrossRefPubMed
10.
go back to reference Martinek V, Seil R, Lattermann C, Watkins SC, Fu FH: The fate of the poly-L-lactic acid interference screw after anterior cruciate ligament reconstruction. Arthroscopy. 2001, 17 (1): 73-76. 10.1053/jars.2001.7797.CrossRefPubMed Martinek V, Seil R, Lattermann C, Watkins SC, Fu FH: The fate of the poly-L-lactic acid interference screw after anterior cruciate ligament reconstruction. Arthroscopy. 2001, 17 (1): 73-76. 10.1053/jars.2001.7797.CrossRefPubMed
11.
go back to reference Fink C, Benedetto KP, Hackl W, Hoser C, Freund MC, Rieger M: Bioabsorbable polyglyconate interference screw fixation in anterior cruciate ligament reconstruction: a prospective computed tomography-controlled study. Arthroscopy. 2000, 16 (5): 491-498. 10.1053/jars.2000.4633.CrossRefPubMed Fink C, Benedetto KP, Hackl W, Hoser C, Freund MC, Rieger M: Bioabsorbable polyglyconate interference screw fixation in anterior cruciate ligament reconstruction: a prospective computed tomography-controlled study. Arthroscopy. 2000, 16 (5): 491-498. 10.1053/jars.2000.4633.CrossRefPubMed
12.
go back to reference Marti C, Imhoff AB, Bahrs C, Romero J: Metallic versus bioabsorbable interference screw for fixation of bone-patellar tendon-bone autograft in arthroscopic anterior cruciate ligament reconstruction. A preliminary report. Knee Surg Sports Traumatol Arthrosc. 1997, 5 (4): 217-221. 10.1007/s001670050053.CrossRefPubMed Marti C, Imhoff AB, Bahrs C, Romero J: Metallic versus bioabsorbable interference screw for fixation of bone-patellar tendon-bone autograft in arthroscopic anterior cruciate ligament reconstruction. A preliminary report. Knee Surg Sports Traumatol Arthrosc. 1997, 5 (4): 217-221. 10.1007/s001670050053.CrossRefPubMed
13.
go back to reference Martinek V, Friederich NF: Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation. Arthroscopy. 1999, 15 (3): 317-320. 10.1016/S0749-8063(99)70042-3.CrossRefPubMed Martinek V, Friederich NF: Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation. Arthroscopy. 1999, 15 (3): 317-320. 10.1016/S0749-8063(99)70042-3.CrossRefPubMed
14.
go back to reference Zantop T, Weimann A, Schmidtko R, Herbort M, Raschke MJ, Petersen W: Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d,l-lactide, and poly-d,l-lactide-tricalcium phosphate screws. Arthroscopy. 2006, 22 (11): 1204-1210. 10.1016/j.arthro.2006.06.015.CrossRefPubMed Zantop T, Weimann A, Schmidtko R, Herbort M, Raschke MJ, Petersen W: Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d,l-lactide, and poly-d,l-lactide-tricalcium phosphate screws. Arthroscopy. 2006, 22 (11): 1204-1210. 10.1016/j.arthro.2006.06.015.CrossRefPubMed
15.
go back to reference Radford MJ, Noakes J, Read J, Wood DG: The natural history of a bioabsorbable interference screw used for anterior cruciate ligament reconstruction with a 4-strand hamstring technique. Arthroscopy. 2005, 21 (6): 707-710. 10.1016/j.arthro.2005.03.005.CrossRefPubMed Radford MJ, Noakes J, Read J, Wood DG: The natural history of a bioabsorbable interference screw used for anterior cruciate ligament reconstruction with a 4-strand hamstring technique. Arthroscopy. 2005, 21 (6): 707-710. 10.1016/j.arthro.2005.03.005.CrossRefPubMed
16.
go back to reference Stener S, Ejerhed L, Sernert N, Laxdal G, Rostgard-Christensen L, Kartus J: A Long-Term, Prospective, Randomized Study Comparing Biodegradable and Metal Interference Screws in Anterior Cruciate Ligament Reconstruction Surgery: Radiographic Results and Clinical Outcome. Am J Sports Med. 2010 Stener S, Ejerhed L, Sernert N, Laxdal G, Rostgard-Christensen L, Kartus J: A Long-Term, Prospective, Randomized Study Comparing Biodegradable and Metal Interference Screws in Anterior Cruciate Ligament Reconstruction Surgery: Radiographic Results and Clinical Outcome. Am J Sports Med. 2010
17.
go back to reference Shen C, Jiang SD, Jiang LS, Dai LY: Bioabsorbable versus metallic interference screw fixation in anterior cruciate ligament reconstruction: a meta-analysis of randomized controlled trials. Arthroscopy. 26 (5): 705-713. 10.1016/j.arthro.2009.12.011. Shen C, Jiang SD, Jiang LS, Dai LY: Bioabsorbable versus metallic interference screw fixation in anterior cruciate ligament reconstruction: a meta-analysis of randomized controlled trials. Arthroscopy. 26 (5): 705-713. 10.1016/j.arthro.2009.12.011.
18.
go back to reference Stockheim M, Most-Ehrlein S, Rothschenk HJ, Wirbel R: [Cartilage damage caused by a dislocated resorbable interference screw of poly(L-lactide) 46 months after anterior cruciate ligament reconstruction]. Z Orthop Unfall. 148 (1): 44-48. 10.1055/s-0029-1240700. Stockheim M, Most-Ehrlein S, Rothschenk HJ, Wirbel R: [Cartilage damage caused by a dislocated resorbable interference screw of poly(L-lactide) 46 months after anterior cruciate ligament reconstruction]. Z Orthop Unfall. 148 (1): 44-48. 10.1055/s-0029-1240700.
19.
go back to reference Baums MH, Zelle BA, Schultz W, Ernstberger T, Klinger HM: Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc. 2006, 14 (9): 865-868. 10.1007/s00167-006-0049-2.CrossRefPubMed Baums MH, Zelle BA, Schultz W, Ernstberger T, Klinger HM: Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc. 2006, 14 (9): 865-868. 10.1007/s00167-006-0049-2.CrossRefPubMed
20.
go back to reference Sassmannshausen G, Carr CF: Transcutaneous migration of a tibial bioabsorbable interference screw after anterior cruciate ligament reconstruction. Arthroscopy. 2003, 19 (9): E133-136. 10.1016/j.arthro.2003.09.017.CrossRefPubMed Sassmannshausen G, Carr CF: Transcutaneous migration of a tibial bioabsorbable interference screw after anterior cruciate ligament reconstruction. Arthroscopy. 2003, 19 (9): E133-136. 10.1016/j.arthro.2003.09.017.CrossRefPubMed
21.
go back to reference Marchant MH, Willimon SC, Vinson E, Pietrobon R, Garrett WE, Higgins LD: Comparison of plain radiography, computed tomography, and magnetic resonance imaging in the evaluation of bone tunnel widening after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc. 2009, 18 (8): 1059-64. 10.1007/s00167-009-0952-4.CrossRefPubMed Marchant MH, Willimon SC, Vinson E, Pietrobon R, Garrett WE, Higgins LD: Comparison of plain radiography, computed tomography, and magnetic resonance imaging in the evaluation of bone tunnel widening after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc. 2009, 18 (8): 1059-64. 10.1007/s00167-009-0952-4.CrossRefPubMed
22.
go back to reference Inoue M, Tokuyasu S, Kuwahara S, Yasojima N, Kasahara Y, Kondo E, Onodere S, Yasuda K: Tunnel location in transparent 3-dimensional CT in anatomic double-bundle anterior cruciate ligament reconstruction with the trans-tibial tunnel technique. Knee Surg Sports Traumatol Arthrosc. 2009, 18 (9): 1176-83. 10.1007/s00167-009-0989-4.CrossRefPubMed Inoue M, Tokuyasu S, Kuwahara S, Yasojima N, Kasahara Y, Kondo E, Onodere S, Yasuda K: Tunnel location in transparent 3-dimensional CT in anatomic double-bundle anterior cruciate ligament reconstruction with the trans-tibial tunnel technique. Knee Surg Sports Traumatol Arthrosc. 2009, 18 (9): 1176-83. 10.1007/s00167-009-0989-4.CrossRefPubMed
23.
go back to reference Webster KE, Feller JA, Elliott J, Hutchison A, Payne R: A comparison of bone tunnel measurements made using computed tomography and digital plain radiography after anterior cruciate ligament reconstruction. Arthroscopy. 2004, 20 (9): 946-950.CrossRefPubMed Webster KE, Feller JA, Elliott J, Hutchison A, Payne R: A comparison of bone tunnel measurements made using computed tomography and digital plain radiography after anterior cruciate ligament reconstruction. Arthroscopy. 2004, 20 (9): 946-950.CrossRefPubMed
24.
go back to reference Hirschmann MT, Davda K, Iranpour F, Rasch H, Friederich NF: Combined single photon emission computerized tomography and conventional computerized tomography (SPECT/CT) in patellofemoral disorders - a clinical review. Int Orthop. 2010. Hirschmann MT, Davda K, Iranpour F, Rasch H, Friederich NF: Combined single photon emission computerized tomography and conventional computerized tomography (SPECT/CT) in patellofemoral disorders - a clinical review. Int Orthop. 2010.
25.
go back to reference Hirschmann MT, Davda K, Rasch H, Arnold MP, Friederich NF: Clinical value of combined single photon emission computerized tomography and conventional computer tomography (SPECT/CT) in sports medicine. Sports Med Arthrosc Rev. 2010. Hirschmann MT, Davda K, Rasch H, Arnold MP, Friederich NF: Clinical value of combined single photon emission computerized tomography and conventional computer tomography (SPECT/CT) in sports medicine. Sports Med Arthrosc Rev. 2010.
26.
go back to reference Hirschmann MT, Iranpour F, Davda K, Rasch H, Hugli R, Friederich NF: Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons?. Knee Surg Sports Traumatol Arthrosc. 2010, 18 (3): 341-345. 10.1007/s00167-009-0879-9.CrossRefPubMed Hirschmann MT, Iranpour F, Davda K, Rasch H, Hugli R, Friederich NF: Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons?. Knee Surg Sports Traumatol Arthrosc. 2010, 18 (3): 341-345. 10.1007/s00167-009-0879-9.CrossRefPubMed
27.
go back to reference Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF: A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc. 2010, 18 (3): 939-944. 10.1007/s00167-010-1070-z.CrossRefPubMed Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF: A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc. 2010, 18 (3): 939-944. 10.1007/s00167-010-1070-z.CrossRefPubMed
28.
go back to reference Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF, Hirschmann MT: Clinical benefit of SPECT/CT for follow-up of surgical treatment of osteochondritis dissecans. Ann Nucl Med. 2010. Konala P, Iranpour F, Kerner A, Rasch H, Friederich NF, Hirschmann MT: Clinical benefit of SPECT/CT for follow-up of surgical treatment of osteochondritis dissecans. Ann Nucl Med. 2010.
29.
go back to reference Amis AA, Jakob RP: Anterior cruciate ligament graft positioning, tensioning and twisting. Knee Surg Sports Traumatol Arthrosc. 1998, 6 (Suppl 1): S2-12. 10.1007/s001670050215.CrossRefPubMed Amis AA, Jakob RP: Anterior cruciate ligament graft positioning, tensioning and twisting. Knee Surg Sports Traumatol Arthrosc. 1998, 6 (Suppl 1): S2-12. 10.1007/s001670050215.CrossRefPubMed
30.
go back to reference Ma CB, Francis K, Towers J, Irrgang J, Fu FH, Harner CH: Hamstring anterior cruciate ligament reconstruction: a comparison of bioabsorbable interference screw and endobutton-post fixation. Arthroscopy. 2004, 20 (2): 122-128. 10.1016/j.arthro.2003.11.007.CrossRefPubMed Ma CB, Francis K, Towers J, Irrgang J, Fu FH, Harner CH: Hamstring anterior cruciate ligament reconstruction: a comparison of bioabsorbable interference screw and endobutton-post fixation. Arthroscopy. 2004, 20 (2): 122-128. 10.1016/j.arthro.2003.11.007.CrossRefPubMed
31.
go back to reference Ahn JH, Lee SH, Yoo JC, Ha HC: Measurement of the graft angles for the anterior cruciate ligament reconstruction with transtibial technique using postoperative magnetic resonance imaging in comparative study. Knee Surg Sports Traumatol Arthrosc. 2007, 15 (11): 1293-1300. 10.1007/s00167-007-0389-6.CrossRefPubMed Ahn JH, Lee SH, Yoo JC, Ha HC: Measurement of the graft angles for the anterior cruciate ligament reconstruction with transtibial technique using postoperative magnetic resonance imaging in comparative study. Knee Surg Sports Traumatol Arthrosc. 2007, 15 (11): 1293-1300. 10.1007/s00167-007-0389-6.CrossRefPubMed
32.
go back to reference Arnold MP, Verdonschot N, van Kampen A: ACL graft can replicate the normal ligament's tension curve. Knee Surg Sports Traumatol Arthrosc. 2005, 13 (8): 625-631. 10.1007/s00167-004-0601-x.CrossRefPubMed Arnold MP, Verdonschot N, van Kampen A: ACL graft can replicate the normal ligament's tension curve. Knee Surg Sports Traumatol Arthrosc. 2005, 13 (8): 625-631. 10.1007/s00167-004-0601-x.CrossRefPubMed
33.
go back to reference Tomczak RJ, Hehl G, Mergo PJ, Merkle E, Rieber A, Brambs HJ: Tunnel placement in anterior cruciate ligament reconstruction: MRI analysis as an important factor in the radiological report. Skeletal Radiol. 1997, 26 (7): 409-413. 10.1007/s002560050256.CrossRefPubMed Tomczak RJ, Hehl G, Mergo PJ, Merkle E, Rieber A, Brambs HJ: Tunnel placement in anterior cruciate ligament reconstruction: MRI analysis as an important factor in the radiological report. Skeletal Radiol. 1997, 26 (7): 409-413. 10.1007/s002560050256.CrossRefPubMed
34.
go back to reference Behrend H, Stutz G, Kessler MA, Rukavina A, Giesinger K, Kuster MS: Tunnel placement in anterior cruciate ligament (ACL) reconstruction: quality control in a teaching hospital. Knee Surg Sports Traumatol Arthrosc. 2006, 14 (11): 1159-1165. 10.1007/s00167-006-0186-7.CrossRefPubMed Behrend H, Stutz G, Kessler MA, Rukavina A, Giesinger K, Kuster MS: Tunnel placement in anterior cruciate ligament (ACL) reconstruction: quality control in a teaching hospital. Knee Surg Sports Traumatol Arthrosc. 2006, 14 (11): 1159-1165. 10.1007/s00167-006-0186-7.CrossRefPubMed
35.
go back to reference Hogervorst T, van der Hart CP, Pels Rijcken TH, Taconis WK: Abnormal bone scans of the tibial tunnel 2 years after patella ligament anterior cruciate ligament reconstruction: correlation with tunnel enlargement and tibial graft length. Knee Surg Sports Traumatol Arthrosc. 2000, 8 (6): 322-328. 10.1007/s001670000165.CrossRefPubMed Hogervorst T, van der Hart CP, Pels Rijcken TH, Taconis WK: Abnormal bone scans of the tibial tunnel 2 years after patella ligament anterior cruciate ligament reconstruction: correlation with tunnel enlargement and tibial graft length. Knee Surg Sports Traumatol Arthrosc. 2000, 8 (6): 322-328. 10.1007/s001670000165.CrossRefPubMed
Metadata
Title
Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? A case report
Authors
Michael T Hirschmann
Tom Adler
Helmut Rasch
Rolf W Hügli
Niklaus F Friederich
Markus P Arnold
Publication date
01-12-2010
Publisher
BioMed Central
Published in
BMC Sports Science, Medicine and Rehabilitation / Issue 1/2010
Electronic ISSN: 2052-1847
DOI
https://doi.org/10.1186/1758-2555-2-24

Other articles of this Issue 1/2010

BMC Sports Science, Medicine and Rehabilitation 1/2010 Go to the issue