Skip to main content
Top
Published in: Journal of Medical Case Reports 1/2011

Open Access 01-12-2011 | Case report

Asystole following positive pressure insufflation of right pleural cavity: a case report

Authors: Kari M Forde-Thielen, Mojca R Konia

Published in: Journal of Medical Case Reports | Issue 1/2011

Login to get access

Abstract

Introduction

Adverse hemodynamic effects with severe bradycardia have been previously reported during positive pressure insufflation of the right thoracic cavity in humans. To the best of our knowledge, this is the first report of asystole during thoracoscopic surgery with positive pressure insufflation.

Case presentation

A 63-year-old Caucasian woman developed asystole at the onset of positive pressure insufflation of her right hemithorax during a thoracoscopic single-lung ventilation procedure. Immediate deflation of pleural cavity, intravenous glycopyrrolate and atropine administration returned her heart rhythm to normal sinus rhythm. The surgery proceeded in the absence of positive pressure insufflation without any further complications.

Conclusions

We discuss the proposed mechanisms of hemodynamic instability with positive pressure thoracic insufflation, and anesthetic and insufflation techniques that decrease the likelihood of adverse hemodynamic events.
Literature
1.
go back to reference Ohtsuka T, Nakajima J, Kotsuka Y, Takamoto S: Hemodynamic responses to intrapleural insufflation with hemipulmonary collapse. Surg Endosc. 2001, 15 (11): 1327-1330. 10.1007/s00464-001-0037-z.CrossRefPubMed Ohtsuka T, Nakajima J, Kotsuka Y, Takamoto S: Hemodynamic responses to intrapleural insufflation with hemipulmonary collapse. Surg Endosc. 2001, 15 (11): 1327-1330. 10.1007/s00464-001-0037-z.CrossRefPubMed
2.
go back to reference Stensrud PE: Anesthesia for Thoracoscopy. Semin Cardiothorac Vasc Anesth. 2000, 4 (1): 18-25. 10.1177/108925320000400103.CrossRef Stensrud PE: Anesthesia for Thoracoscopy. Semin Cardiothorac Vasc Anesth. 2000, 4 (1): 18-25. 10.1177/108925320000400103.CrossRef
3.
go back to reference Vassiliades TA: The cardiopulmonary effects of single-lung ventilation and carbon dioxide insufflation during thoracoscopic internal mammary artery harvesting. Heart Surg Forum. 2002, 5 (1): 22-24.PubMed Vassiliades TA: The cardiopulmonary effects of single-lung ventilation and carbon dioxide insufflation during thoracoscopic internal mammary artery harvesting. Heart Surg Forum. 2002, 5 (1): 22-24.PubMed
4.
go back to reference Brock H, Rieger R, Gabriel C, Polz W, Moosbauer W, Necek S: Haemodynamic changes during thoracoscopic surgery the effects of one-lung ventilation compared with carbon dioxide insufflation. Anaesthesia. 2000, 55 (1): 10-16. 10.1046/j.1365-2044.2000.01123.x.CrossRefPubMed Brock H, Rieger R, Gabriel C, Polz W, Moosbauer W, Necek S: Haemodynamic changes during thoracoscopic surgery the effects of one-lung ventilation compared with carbon dioxide insufflation. Anaesthesia. 2000, 55 (1): 10-16. 10.1046/j.1365-2044.2000.01123.x.CrossRefPubMed
5.
go back to reference Harris RJ, Benveniste G, Pfitzner J: Cardiovascular collapse caused by carbon dioxide insufflation during one-lung anaesthesia for thoracoscopic dorsal sympathectomy. Anaesth Intensive Care. 2002, 30 (1): 86-89.PubMed Harris RJ, Benveniste G, Pfitzner J: Cardiovascular collapse caused by carbon dioxide insufflation during one-lung anaesthesia for thoracoscopic dorsal sympathectomy. Anaesth Intensive Care. 2002, 30 (1): 86-89.PubMed
6.
go back to reference Hill RC, Jones DR, Vance RA, Kalantarian B: Selective lung ventilation during thoracoscopy: effects of insufflation on hemodynamics. Ann Thorac Surg. 1996, 61 (3): 945-948. 10.1016/0003-4975(95)01150-1.CrossRefPubMed Hill RC, Jones DR, Vance RA, Kalantarian B: Selective lung ventilation during thoracoscopy: effects of insufflation on hemodynamics. Ann Thorac Surg. 1996, 61 (3): 945-948. 10.1016/0003-4975(95)01150-1.CrossRefPubMed
7.
go back to reference Ohtsuka T, Imanaka K, Endoh M, Kohno T, Nakajima J, Kotsuka Y, Takamoto S: Hemodynamic effects of carbon dioxide insufflation under single-lung ventilation during thoracoscopy. Ann Thorac Surg. 1999, 68 (1): 29-32. 10.1016/S0003-4975(99)00319-7. discussion 32-33CrossRefPubMed Ohtsuka T, Imanaka K, Endoh M, Kohno T, Nakajima J, Kotsuka Y, Takamoto S: Hemodynamic effects of carbon dioxide insufflation under single-lung ventilation during thoracoscopy. Ann Thorac Surg. 1999, 68 (1): 29-32. 10.1016/S0003-4975(99)00319-7. discussion 32-33CrossRefPubMed
8.
go back to reference Wolfer RS, Krasna MJ, Hasnain JU, McLaughlin JS: Hemodynamic effects of carbon dioxide insufflation during thoracoscopy. Ann Thorac Surg. 1994, 58 (2): 404-407. 10.1016/0003-4975(94)92215-2. discussion 407-408CrossRefPubMed Wolfer RS, Krasna MJ, Hasnain JU, McLaughlin JS: Hemodynamic effects of carbon dioxide insufflation during thoracoscopy. Ann Thorac Surg. 1994, 58 (2): 404-407. 10.1016/0003-4975(94)92215-2. discussion 407-408CrossRefPubMed
9.
go back to reference Byhahn C, Mierdl S, Meininger D, Wimmer-Greinecker G, Matheis G, Westphal K: Hemodynamics and gas exchange during carbon dioxide insufflation for totally endoscopic coronary artery bypass grafting. Ann Thorac Surg. 2001, 71 (5): 1496-1501. 10.1016/S0003-4975(01)02428-6. discussion 1501-1502CrossRefPubMed Byhahn C, Mierdl S, Meininger D, Wimmer-Greinecker G, Matheis G, Westphal K: Hemodynamics and gas exchange during carbon dioxide insufflation for totally endoscopic coronary artery bypass grafting. Ann Thorac Surg. 2001, 71 (5): 1496-1501. 10.1016/S0003-4975(01)02428-6. discussion 1501-1502CrossRefPubMed
10.
go back to reference Jacobs VR, Morrison JE: The real intraabdominal pressure during laparoscopy: comparison of different insufflators. J Minim Invasive Gynecol. 2007, 14 (1): 103-107. 10.1016/j.jmig.2006.06.025.CrossRefPubMed Jacobs VR, Morrison JE: The real intraabdominal pressure during laparoscopy: comparison of different insufflators. J Minim Invasive Gynecol. 2007, 14 (1): 103-107. 10.1016/j.jmig.2006.06.025.CrossRefPubMed
11.
go back to reference Ko R, McRae K, Darling G, Waddell TK, McGlade D, Cheung K, Katz J, Slinger P: The use of air in the inspired gas mixture during two-lung ventilation delays lung collapse during one-lung ventilation. Anesth Analg. 2009, 108 (4): 1092-1096. 10.1213/ane.0b013e318195415f.CrossRefPubMed Ko R, McRae K, Darling G, Waddell TK, McGlade D, Cheung K, Katz J, Slinger P: The use of air in the inspired gas mixture during two-lung ventilation delays lung collapse during one-lung ventilation. Anesth Analg. 2009, 108 (4): 1092-1096. 10.1213/ane.0b013e318195415f.CrossRefPubMed
Metadata
Title
Asystole following positive pressure insufflation of right pleural cavity: a case report
Authors
Kari M Forde-Thielen
Mojca R Konia
Publication date
01-12-2011
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2011
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/1752-1947-5-257

Other articles of this Issue 1/2011

Journal of Medical Case Reports 1/2011 Go to the issue