Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2011

Open Access 01-12-2011 | Research article

A comparison of two headless compression screws for operative treatment of scaphoid fractures

Authors: Ruby Grewal, Joseph Assini, David Sauder, Louis Ferreira, Jim Johnson, Kenneth Faber

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2011

Login to get access

Abstract

Purpose

The purpose of this study was to compare the interfragmentary compression force across a simulated scaphoid fracture by two commonly used compression screw systems; the Acutrak 2 Standard and the 3.0 mm Synthes headless compression screw.

Methods

Sixteen (8 pairs; 6 female, 2 male) cadaver scaphoids were randomly assigned to receive either the Acutrak 2 or Synthes screw with the contralateral scaphoid designated to receive the opposite. Guide wires were inserted under fluoroscopic control. Following transverse osteotomy, the distal and proximal fragments were placed on either side of a custom load cell, to measure interfragmentary compression. Screws were placed under fluoroscopic control using the manufacturer's recommended surgical technique. Compressive forces were measured during screw insertion. Recording continued for an additional 60s in order to measure any loss of compression after installation was complete. The peak and final interfragmentary compression were recorded and paired t-tests performed.

Results

The mean peak compression generated by the Acutrak 2 Standard was greater than that produced by the Synthes compression screw (103.9 ± 33.2 N vs. 88.7 ± 38.6 N respectively, p = 0.13). The mean final interfragmentary compression generated by the Acutrak 2 screw (68.6 ± 36.4 N) was significantly greater (p = 0.04) than the Synthes screw (37.2 ± 26.8 N). Specimens typically reached a steady state of compression by 120-150s after final tightening.

Conclusion

Peak interfragmentary compression observed during screw installation was similar for both screw systems. However, the mean interfragmentary compression generated by the Acutrak 2 Standard was significantly greater. Our study demonstrates that the Synthes headless compression screw experienced a greater loss of interfragmentary compressive force from the time of installation to the final steady state compression level. The higher post-installation compression of the Acutrak 2 Standard may be attributable to the greater number of threads throughout the entire length of the screw. The clinical significance of these results, are, at this point uncertain. We do demonstrate that a fully threaded design offers a more reliable compression that may translate to more predictable bony union.
Appendix
Available only for authorised users
Literature
1.
go back to reference Amadio P, Taleisnik J: Fractures of the carpal bones. Green's operative hand surgery. Edited by: Green DP, Hotchkiss RN, Pederson C. 1999, Philadelphia: Churchill Livingston, 809-856. 4 Amadio P, Taleisnik J: Fractures of the carpal bones. Green's operative hand surgery. Edited by: Green DP, Hotchkiss RN, Pederson C. 1999, Philadelphia: Churchill Livingston, 809-856. 4
2.
go back to reference Johner R, Joerger K, Perren SM: Rigidity of pure lag screw fixation as a function of screw inclination in an in vivo spiral osteotomy. Clin Orthop. 1983, 178: 74-79.PubMed Johner R, Joerger K, Perren SM: Rigidity of pure lag screw fixation as a function of screw inclination in an in vivo spiral osteotomy. Clin Orthop. 1983, 178: 74-79.PubMed
3.
go back to reference Aro HT, Choa EY: Bone healing patterns affected by loading, fracture fragment stability, fracture type and fracture site compression. Clin Orthop. 1993, 293: 8-17.PubMed Aro HT, Choa EY: Bone healing patterns affected by loading, fracture fragment stability, fracture type and fracture site compression. Clin Orthop. 1993, 293: 8-17.PubMed
4.
go back to reference Lewallen DG, Chao EY, Kasman RA, Kelley PJ: Comparison of the effects of compression plates and external fixators on early bone healing. J Bone Joint Surg. 1984, 66A: 1084-1091. Lewallen DG, Chao EY, Kasman RA, Kelley PJ: Comparison of the effects of compression plates and external fixators on early bone healing. J Bone Joint Surg. 1984, 66A: 1084-1091.
5.
go back to reference Szabo R, Sutherland T: Acute carpal fractures and dislocations. Surgery of the hand and upper extremity. Edited by: Peimer CA. 1996, New York: McGraw-Hill, 711-726. Szabo R, Sutherland T: Acute carpal fractures and dislocations. Surgery of the hand and upper extremity. Edited by: Peimer CA. 1996, New York: McGraw-Hill, 711-726.
6.
go back to reference Trumble TE: Fractures and dislocations of the carpus. Principle of hand surgery and therapy. Edited by: Trumble TE. 2000, Philadelphia: Saunders, 90-126. Trumble TE: Fractures and dislocations of the carpus. Principle of hand surgery and therapy. Edited by: Trumble TE. 2000, Philadelphia: Saunders, 90-126.
7.
go back to reference Kalainov DM, Osterman AL: Diagnosis and management of scaphoid fractures. Edited by: Waston HK, Weinzweig J. 2001, The wrist, Lippincott, 187-202. Kalainov DM, Osterman AL: Diagnosis and management of scaphoid fractures. Edited by: Waston HK, Weinzweig J. 2001, The wrist, Lippincott, 187-202.
8.
go back to reference Adolfsson L, Lindau T, Amer M: Acutrak screw fixation versus cast immobilization for undisplaced scaphoid waist fractures. J Hand Surg. 2001, 26B: 192-195.CrossRef Adolfsson L, Lindau T, Amer M: Acutrak screw fixation versus cast immobilization for undisplaced scaphoid waist fractures. J Hand Surg. 2001, 26B: 192-195.CrossRef
9.
go back to reference Bond CD, Shin AY, McBride MT, Doa KD: Percutaneous screw fixation or cast immobilization for nondisplaced scaphoid fractures. J Bone Joint Surg. 2001, 83A: 483-488. Bond CD, Shin AY, McBride MT, Doa KD: Percutaneous screw fixation or cast immobilization for nondisplaced scaphoid fractures. J Bone Joint Surg. 2001, 83A: 483-488.
10.
go back to reference Shin AY, Hofmeister EP: Volar percutaneous fixation of stable scaphoid fractures. Atlas of Hand Clinics. 2003, 19-28. 1 Shin AY, Hofmeister EP: Volar percutaneous fixation of stable scaphoid fractures. Atlas of Hand Clinics. 2003, 19-28. 1
11.
go back to reference Shin AY, Hofmeister EP: Percutaneous fixation of stable scaphoid fractures. Techniques in Hand and Upper Extremity Surgery. 2004, 87-94. 2 Shin AY, Hofmeister EP: Percutaneous fixation of stable scaphoid fractures. Techniques in Hand and Upper Extremity Surgery. 2004, 87-94. 2
12.
go back to reference Dao KD, Shin AY: Percutaneous cannulated screw fixation of acute nondisplaced scaphoid waist fractures. Atlas of Hand Clinics. 2004, 141-8. 2 Dao KD, Shin AY: Percutaneous cannulated screw fixation of acute nondisplaced scaphoid waist fractures. Atlas of Hand Clinics. 2004, 141-8. 2
13.
go back to reference Arora R, Gschwentner M, Krappinger D, Lutz M, Blauth M, Gabl M: Fixation of nondisplaced scaphoid fractures: making treatment cost effective. Prospective controlled trial. Arch Orthop Trauma Surg. 2007, 127 (1): 39-46.CrossRefPubMed Arora R, Gschwentner M, Krappinger D, Lutz M, Blauth M, Gabl M: Fixation of nondisplaced scaphoid fractures: making treatment cost effective. Prospective controlled trial. Arch Orthop Trauma Surg. 2007, 127 (1): 39-46.CrossRefPubMed
14.
go back to reference McQueen MM, Gelbke MK, Wakefield A, Will EM, Gaebler C: Percutaneous screw fixation versus conservative treatment for fractures of the waist of the scaphoid: a prospective randomized study. J Bone Joint Surg - Br. 2008, 90 (1): 66-71. 10.1302/0301-620X.90B1.19767.CrossRefPubMed McQueen MM, Gelbke MK, Wakefield A, Will EM, Gaebler C: Percutaneous screw fixation versus conservative treatment for fractures of the waist of the scaphoid: a prospective randomized study. J Bone Joint Surg - Br. 2008, 90 (1): 66-71. 10.1302/0301-620X.90B1.19767.CrossRefPubMed
15.
go back to reference Dias JJ, Dhukaram V, Abhinav A, Bhowal B, Wildin CJ: Clinical and radiological outcome of cast immobilization versus surgical treatment of acute scaphoid fractures at a mean follow-up of 93 months. J Bone Joint Surg. 2008, 90 (7): 899-905. 10.1302/0301-620X.90B7.20371.CrossRef Dias JJ, Dhukaram V, Abhinav A, Bhowal B, Wildin CJ: Clinical and radiological outcome of cast immobilization versus surgical treatment of acute scaphoid fractures at a mean follow-up of 93 months. J Bone Joint Surg. 2008, 90 (7): 899-905. 10.1302/0301-620X.90B7.20371.CrossRef
16.
go back to reference Vinnars B, Pietreanu M, Bodestedt A, Ekenstam F, Gerdin B: Nonoperative compared with operative treatment of acute scaphoid fractures. A randomized clinical trial. J Bone Joint Surg. 2008, 90 (6): 1176-85. 10.2106/JBJS.G.00673.CrossRefPubMed Vinnars B, Pietreanu M, Bodestedt A, Ekenstam F, Gerdin B: Nonoperative compared with operative treatment of acute scaphoid fractures. A randomized clinical trial. J Bone Joint Surg. 2008, 90 (6): 1176-85. 10.2106/JBJS.G.00673.CrossRefPubMed
17.
go back to reference Beadel GP, Ferreira L, Johnson JA, King GJ: Interfragmentary compression across a simulated scaphoid fracture--analysis of 3 screws. J Hand Surg [Am]. 2004, 29 (2): 273-8. 10.1016/j.jhsa.2003.12.006.CrossRef Beadel GP, Ferreira L, Johnson JA, King GJ: Interfragmentary compression across a simulated scaphoid fracture--analysis of 3 screws. J Hand Surg [Am]. 2004, 29 (2): 273-8. 10.1016/j.jhsa.2003.12.006.CrossRef
18.
go back to reference Lo IK, King GW, Patterson SD, Johnson JA, Chess DG: A biomechanical analysis of the intrascaphoid compression using the 3.00mm Synthes cannulated screw and threaded washer: An in vitro cadaveric study. J Hand Surg [Br]. 2001, 26 (1): 22-24.CrossRef Lo IK, King GW, Patterson SD, Johnson JA, Chess DG: A biomechanical analysis of the intrascaphoid compression using the 3.00mm Synthes cannulated screw and threaded washer: An in vitro cadaveric study. J Hand Surg [Br]. 2001, 26 (1): 22-24.CrossRef
19.
go back to reference Bailey CA, Kuiper JH, Kelly CP: Biomechanical evaluation of a new composite bioresorbable screw. J Hand Surg [Am]. 2006, 31 (2): 208-212.CrossRef Bailey CA, Kuiper JH, Kelly CP: Biomechanical evaluation of a new composite bioresorbable screw. J Hand Surg [Am]. 2006, 31 (2): 208-212.CrossRef
Metadata
Title
A comparison of two headless compression screws for operative treatment of scaphoid fractures
Authors
Ruby Grewal
Joseph Assini
David Sauder
Louis Ferreira
Jim Johnson
Kenneth Faber
Publication date
01-12-2011
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2011
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/1749-799X-6-27

Other articles of this Issue 1/2011

Journal of Orthopaedic Surgery and Research 1/2011 Go to the issue