Skip to main content
Top
Published in: Journal of NeuroEngineering and Rehabilitation 1/2010

Open Access 01-12-2010 | Research

On the identification of sensory information from mixed nerves by using single-channel cuff electrodes

Authors: Stanisa Raspopovic, Jacopo Carpaneto, Esther Udina, Xavier Navarro, Silvestro Micera

Published in: Journal of NeuroEngineering and Rehabilitation | Issue 1/2010

Login to get access

Abstract

Background

Several groups have shown that the performance of motor neuroprostheses can be significantly improved by detecting specific sensory events related to the ongoing motor task (e.g., the slippage of an object during grasping). Algorithms have been developed to achieve this goal by processing electroneurographic (ENG) afferent signals recorded by using single-channel cuff electrodes. However, no efforts have been made so far to understand the number and type of detectable sensory events that can be differentiated from whole nerve recordings using this approach.

Methods

To this aim, ENG afferent signals, evoked by different sensory stimuli were recorded using single-channel cuff electrodes placed around the sciatic nerve of anesthetized rats. The ENG signals were digitally processed and several features were extracted and used as inputs for the classification. The work was performed on integral datasets, without eliminating any noisy parts, in order to be as close as possible to real application.

Results

The results obtained showed that single-channel cuff electrodes are able to provide information on two to three different afferent (proprioceptive, mechanical and nociceptive) stimuli, with reasonably good discrimination ability. The classification performances are affected by the SNR of the signal, which in turn is related to the diameter of the fibers encoding a particular type of neurophysiological stimulus.

Conclusions

Our findings indicate that signals of acceptable SNR and corresponding to different physiological modalities (e.g. mediated by different types of nerve fibers) may be distinguished.
Appendix
Available only for authorised users
Literature
1.
go back to reference Peckham PH, Knutson JS: Functional electrical stimulation for neuromuscular applications. Annu Rev Biomed Eng 2005, 7: 327-360. 10.1146/annurev.bioeng.6.040803.140103CrossRefPubMed Peckham PH, Knutson JS: Functional electrical stimulation for neuromuscular applications. Annu Rev Biomed Eng 2005, 7: 327-360. 10.1146/annurev.bioeng.6.040803.140103CrossRefPubMed
2.
go back to reference Haugland M, Lickel A, Haase J, Sinkjær T: Control of FES thumb force using slip information obtained from the cutaneous electroneurogram in quadriplegic man. IEEE Trans Neural Syst Rehabil Eng 1999, 7: 215-227.CrossRef Haugland M, Lickel A, Haase J, Sinkjær T: Control of FES thumb force using slip information obtained from the cutaneous electroneurogram in quadriplegic man. IEEE Trans Neural Syst Rehabil Eng 1999, 7: 215-227.CrossRef
3.
go back to reference Popovic D, Stein RB, Jovanovic K, Dai N, Kostov A, Armstrong WW: Sensory nerve recording for closed-loop control to restore motor functions. IEEE Trans Biomed Eng 1993, 10: 1024-31. 10.1109/10.247801CrossRef Popovic D, Stein RB, Jovanovic K, Dai N, Kostov A, Armstrong WW: Sensory nerve recording for closed-loop control to restore motor functions. IEEE Trans Biomed Eng 1993, 10: 1024-31. 10.1109/10.247801CrossRef
4.
go back to reference Agarwal S, Triolo RJ, Kobetic R, Miller M, Bieri C, Kukk S, Rohde L, Davis JA: Longterm user perceptions of an implanted neuroprosthesis for exercise, standing, and transfers after spinal cord injury. J Rehabil Res Dev 2003, 40: 241-252.PubMed Agarwal S, Triolo RJ, Kobetic R, Miller M, Bieri C, Kukk S, Rohde L, Davis JA: Longterm user perceptions of an implanted neuroprosthesis for exercise, standing, and transfers after spinal cord injury. J Rehabil Res Dev 2003, 40: 241-252.PubMed
5.
go back to reference Guiraud D, Stieglitz T, Koch KP, Divoux JL, Rabischong P: An implantable neuroprosthesis for standing and walking in paraplegia: 5-year patient follow-up. J Neural Eng 2006, 3: 268-275. 10.1088/1741-2560/3/4/003CrossRefPubMed Guiraud D, Stieglitz T, Koch KP, Divoux JL, Rabischong P: An implantable neuroprosthesis for standing and walking in paraplegia: 5-year patient follow-up. J Neural Eng 2006, 3: 268-275. 10.1088/1741-2560/3/4/003CrossRefPubMed
6.
go back to reference Sheffler LR, Chae J: Neuromuscular electrical stimulation in neurorehabilitation. Muscle Nerve 2007, 35: 562-590. 10.1002/mus.20758CrossRefPubMed Sheffler LR, Chae J: Neuromuscular electrical stimulation in neurorehabilitation. Muscle Nerve 2007, 35: 562-590. 10.1002/mus.20758CrossRefPubMed
7.
go back to reference Wuolle KS, Van Doren CL, Bryden AM, Peckham PH, Keith MW, Kilgore KL, Grill JH: Satisfaction with and usage of a hand neuroprosthesis. Arch Phys Med Rehabil 1999, 80: 206-213. 10.1016/S0003-9993(99)90123-5CrossRef Wuolle KS, Van Doren CL, Bryden AM, Peckham PH, Keith MW, Kilgore KL, Grill JH: Satisfaction with and usage of a hand neuroprosthesis. Arch Phys Med Rehabil 1999, 80: 206-213. 10.1016/S0003-9993(99)90123-5CrossRef
8.
go back to reference Johnson MW, Peckham PH, Bhadra N, Kilgore KL, Gazdik MM, Keith MW, Strojnik P: Implantable transducer for two-degree of freedom joint angle sensing. IEEE Trans Rehabil Eng 1999, 7: 349-359. 10.1109/86.788471CrossRefPubMed Johnson MW, Peckham PH, Bhadra N, Kilgore KL, Gazdik MM, Keith MW, Strojnik P: Implantable transducer for two-degree of freedom joint angle sensing. IEEE Trans Rehabil Eng 1999, 7: 349-359. 10.1109/86.788471CrossRefPubMed
9.
go back to reference Cavallaro E, Cappiello G, Micera S, Carrozza MC, Rantanen P, Dario P: On the development of a biomechatronic system to record tendon sliding movements. IEEE Trans Biomed Eng 2005, 52: 1110-1119. 10.1109/TBME.2005.846711CrossRefPubMed Cavallaro E, Cappiello G, Micera S, Carrozza MC, Rantanen P, Dario P: On the development of a biomechatronic system to record tendon sliding movements. IEEE Trans Biomed Eng 2005, 52: 1110-1119. 10.1109/TBME.2005.846711CrossRefPubMed
10.
go back to reference de Castro MC, Cliquet A Jr: An artificial grasping evaluation system for the paralyzed hand. Med Biol Eng Comput 2000, 38: 275-280. 10.1007/BF02347047CrossRefPubMed de Castro MC, Cliquet A Jr: An artificial grasping evaluation system for the paralyzed hand. Med Biol Eng Comput 2000, 38: 275-280. 10.1007/BF02347047CrossRefPubMed
11.
go back to reference Carpaneto J, Micera S, Zaccone F, Vecchi F, Dario P: A sensorized thumb for force closed-loop control of hand neuroprostheses. IEEE Trans Neural Syst Rehabil Eng 2003, 11: 346-353. 10.1109/TNSRE.2003.819938CrossRefPubMed Carpaneto J, Micera S, Zaccone F, Vecchi F, Dario P: A sensorized thumb for force closed-loop control of hand neuroprostheses. IEEE Trans Neural Syst Rehabil Eng 2003, 11: 346-353. 10.1109/TNSRE.2003.819938CrossRefPubMed
12.
go back to reference Navarro X, Krueger TB, Lago N, Micera S, Stieglitz T, Dario P: A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems. J Peripher Nerv Syst 2005, 10: 229-258. 10.1111/j.1085-9489.2005.10303.xCrossRefPubMed Navarro X, Krueger TB, Lago N, Micera S, Stieglitz T, Dario P: A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems. J Peripher Nerv Syst 2005, 10: 229-258. 10.1111/j.1085-9489.2005.10303.xCrossRefPubMed
13.
go back to reference Haugland M, Hoffer J, Sinkjaer T: Skin contact force information in sensory nerve signals recorded by implanted cuff electrodes. IEEE Trans Rehabil Eng 1994, 2: 18-28. 10.1109/86.296346CrossRef Haugland M, Hoffer J, Sinkjaer T: Skin contact force information in sensory nerve signals recorded by implanted cuff electrodes. IEEE Trans Rehabil Eng 1994, 2: 18-28. 10.1109/86.296346CrossRef
14.
go back to reference Haugland M, Hoffer J: Slip information provided by nerve cuff signals: application in closed-loop control of functional electrical stimulation. IEEE Trans Rehabil Eng 1994, 2: 29-36. 10.1109/86.296345CrossRef Haugland M, Hoffer J: Slip information provided by nerve cuff signals: application in closed-loop control of functional electrical stimulation. IEEE Trans Rehabil Eng 1994, 2: 29-36. 10.1109/86.296345CrossRef
15.
go back to reference Haugland MK, Sinkjaer T: Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man. IEEE Trans Rehabil Eng 1995, 3: 307-317. 10.1109/86.481970CrossRef Haugland MK, Sinkjaer T: Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man. IEEE Trans Rehabil Eng 1995, 3: 307-317. 10.1109/86.481970CrossRef
16.
go back to reference Inmann A, Haugland M: Implementation of natural sensory feedback in a portable control system for a hand grasp neuroprosthesis. Med Eng Phys 2004, 26: 449-458. 10.1016/j.medengphy.2004.03.003CrossRefPubMed Inmann A, Haugland M: Implementation of natural sensory feedback in a portable control system for a hand grasp neuroprosthesis. Med Eng Phys 2004, 26: 449-458. 10.1016/j.medengphy.2004.03.003CrossRefPubMed
17.
go back to reference Stein RB, Charles D, Hoffer JA, Arsenault J, Davis LA, Moorman S, Moss B: New approaches for the control of powered prostheses particularly by high-level amputees. Bull Prosthet Res 1980, 10: 51-62.PubMed Stein RB, Charles D, Hoffer JA, Arsenault J, Davis LA, Moorman S, Moss B: New approaches for the control of powered prostheses particularly by high-level amputees. Bull Prosthet Res 1980, 10: 51-62.PubMed
18.
go back to reference Yoo PB, Durand DM: Selective recording of the canine hypoglossal nerve using a multicontact flat interface nerve electrode. IEEE Trans Biomed Eng 2005, 52: 1461-1469. 10.1109/TBME.2005.851482CrossRefPubMed Yoo PB, Durand DM: Selective recording of the canine hypoglossal nerve using a multicontact flat interface nerve electrode. IEEE Trans Biomed Eng 2005, 52: 1461-1469. 10.1109/TBME.2005.851482CrossRefPubMed
19.
go back to reference Stein RB, Nichols TR, Jhamandas J, Davis L, Charles D: Stable long-term recordings from cat peripheral nerves. Brain Res 1977, 128: 21-38. 10.1016/0006-8993(77)90233-5CrossRefPubMed Stein RB, Nichols TR, Jhamandas J, Davis L, Charles D: Stable long-term recordings from cat peripheral nerves. Brain Res 1977, 128: 21-38. 10.1016/0006-8993(77)90233-5CrossRefPubMed
20.
go back to reference Rodriguez FJ, Ceballos D, Schuttler M, Valero A, Valderrama E, Stieglitz T, Navarro X: Polyimide cuff electrodes for peripheral nerve stimulation. J Neurosci Methods 2000, 98: 105-118. 10.1016/S0165-0270(00)00192-8CrossRefPubMed Rodriguez FJ, Ceballos D, Schuttler M, Valero A, Valderrama E, Stieglitz T, Navarro X: Polyimide cuff electrodes for peripheral nerve stimulation. J Neurosci Methods 2000, 98: 105-118. 10.1016/S0165-0270(00)00192-8CrossRefPubMed
21.
go back to reference Upshaw B, Sinkjaer T: Digital signal processing algorithms for the detection of afferent nerve activity recorded from cuff electrodes. IEEE Trans Rehabil Eng 1998, 6: 172-181. 10.1109/86.681183CrossRefPubMed Upshaw B, Sinkjaer T: Digital signal processing algorithms for the detection of afferent nerve activity recorded from cuff electrodes. IEEE Trans Rehabil Eng 1998, 6: 172-181. 10.1109/86.681183CrossRefPubMed
22.
go back to reference Jezernik S, Sinkjaer T: On Statistical Properties of Whole Nerve Cuff Recordings. IEEE Trans Biomed Eng 1999, 46: 1240-1245. 10.1109/10.790501CrossRefPubMed Jezernik S, Sinkjaer T: On Statistical Properties of Whole Nerve Cuff Recordings. IEEE Trans Biomed Eng 1999, 46: 1240-1245. 10.1109/10.790501CrossRefPubMed
23.
go back to reference Jezernik S, Grill WM, Sinkjaer T: Neural network classification of nerve activity recorded in a mixed nerve. Neurol Res 2001, 23: 429-434. 10.1179/016164101101198811CrossRefPubMed Jezernik S, Grill WM, Sinkjaer T: Neural network classification of nerve activity recorded in a mixed nerve. Neurol Res 2001, 23: 429-434. 10.1179/016164101101198811CrossRefPubMed
24.
go back to reference Zhou L, Donaldson NN: When can the autocorrelation be used for the classification of ENG signals? In proceedings IFESS Conf Vienna 2001. Zhou L, Donaldson NN: When can the autocorrelation be used for the classification of ENG signals? In proceedings IFESS Conf Vienna 2001.
25.
go back to reference Zecca M, Micera S, Carrozza MC, Dario P: Control of multifunctional prosthetic hands by processing the electromyographic signal. Crit Rev Biomed Eng 2002, 30: 459-485. 10.1615/CritRevBiomedEng.v30.i456.80CrossRefPubMed Zecca M, Micera S, Carrozza MC, Dario P: Control of multifunctional prosthetic hands by processing the electromyographic signal. Crit Rev Biomed Eng 2002, 30: 459-485. 10.1615/CritRevBiomedEng.v30.i456.80CrossRefPubMed
26.
go back to reference Kang WJ, Cheng CK, Lai JS, Shiu JR, Kuo TS: A comparative analysis of various EMG pattern recognition methods. Med Eng Phys 1996, 18: 390-395. 10.1016/1350-4533(95)00065-8CrossRefPubMed Kang WJ, Cheng CK, Lai JS, Shiu JR, Kuo TS: A comparative analysis of various EMG pattern recognition methods. Med Eng Phys 1996, 18: 390-395. 10.1016/1350-4533(95)00065-8CrossRefPubMed
27.
go back to reference Graupe D: EMG pattern analysis for patient-responsive control of FES in paraplegics for walker-supported walking. IEEE Trans Biomed Eng 1989, 6: 711-719. 10.1109/10.32103CrossRef Graupe D: EMG pattern analysis for patient-responsive control of FES in paraplegics for walker-supported walking. IEEE Trans Biomed Eng 1989, 6: 711-719. 10.1109/10.32103CrossRef
28.
go back to reference Diedrich A, Charoensuk W, Brychta RJ, Ertl AC, Shiavi R: Analysis of raw microneurographic recordings based on wavelet de-noising technique and classification algorithm: wavelet analysis in microneurography. IEEE Trans Biomed Eng 2003, 50: 41-50. 10.1109/TBME.2002.807323CrossRefPubMed Diedrich A, Charoensuk W, Brychta RJ, Ertl AC, Shiavi R: Analysis of raw microneurographic recordings based on wavelet de-noising technique and classification algorithm: wavelet analysis in microneurography. IEEE Trans Biomed Eng 2003, 50: 41-50. 10.1109/TBME.2002.807323CrossRefPubMed
29.
go back to reference Citi L, Carpaneto J, Yoshida K, Hoffmann KP, Koch KP, Dario P, Micera S: On the use of wavelet denoising and spike sorting techniques to process ENG signals recorded using intraneural electrodes. J Neurosci Methods 2008, 172: 294-302. 10.1016/j.jneumeth.2008.04.025CrossRefPubMed Citi L, Carpaneto J, Yoshida K, Hoffmann KP, Koch KP, Dario P, Micera S: On the use of wavelet denoising and spike sorting techniques to process ENG signals recorded using intraneural electrodes. J Neurosci Methods 2008, 172: 294-302. 10.1016/j.jneumeth.2008.04.025CrossRefPubMed
30.
go back to reference Englehart K, Hudgins B: A robust, real-time control scheme for multifunction myoelectric control. IEEE Trans Biomed Eng 2003, 50: 848-854. 10.1109/TBME.2003.813539CrossRefPubMed Englehart K, Hudgins B: A robust, real-time control scheme for multifunction myoelectric control. IEEE Trans Biomed Eng 2003, 50: 848-854. 10.1109/TBME.2003.813539CrossRefPubMed
31.
go back to reference Oskoei MA, Hu H: Support vector machine-based classification scheme for myoelectric control applied to upper limb. IEEE Trans Biomed Eng 2008, 55: 1956-1965. 10.1109/TBME.2008.919734CrossRefPubMed Oskoei MA, Hu H: Support vector machine-based classification scheme for myoelectric control applied to upper limb. IEEE Trans Biomed Eng 2008, 55: 1956-1965. 10.1109/TBME.2008.919734CrossRefPubMed
32.
go back to reference Duin RPW, Juszczak P, Paclik P, Pekalska E, de Ridder D, Tax DM, Verzakov S: PRTools 4.1, A Matlab Toolbox for Pattern Recognition. Delft University of Technology; 2007. Duin RPW, Juszczak P, Paclik P, Pekalska E, de Ridder D, Tax DM, Verzakov S: PRTools 4.1, A Matlab Toolbox for Pattern Recognition. Delft University of Technology; 2007.
33.
go back to reference Vapnik V, Golowich S, Smola AJ: Support vector method for function approximation, regression estimation, and signal processing. Volume 9. Neur Infor Process Sys MIT Press; 1997. Vapnik V, Golowich S, Smola AJ: Support vector method for function approximation, regression estimation, and signal processing. Volume 9. Neur Infor Process Sys MIT Press; 1997.
35.
go back to reference Farrell TR, Weir RF: The optimal controller delay for myoelectric prostheses. IEEE Trans Neural Syst Rehabil Eng 2007, 15: 111-118. 10.1109/TNSRE.2007.891391CrossRefPubMed Farrell TR, Weir RF: The optimal controller delay for myoelectric prostheses. IEEE Trans Neural Syst Rehabil Eng 2007, 15: 111-118. 10.1109/TNSRE.2007.891391CrossRefPubMed
36.
go back to reference Johnson KO, Popovic D, Riso RR, Koris R, Van Doren C, Kantor C: Perspectives on the role of afferent signals in control of motor neuroprostheses. Med Eng Phy 1995, 17: 481-496. 10.1016/1350-4533(95)00003-6CrossRef Johnson KO, Popovic D, Riso RR, Koris R, Van Doren C, Kantor C: Perspectives on the role of afferent signals in control of motor neuroprostheses. Med Eng Phy 1995, 17: 481-496. 10.1016/1350-4533(95)00003-6CrossRef
37.
go back to reference Jensen W, Riso R, Sinkjaer T: Effect of intertrial delay on whole nerve cuff recordings of muscle afferents in rabbits. Neuromodulation 2000, 3: 43-53. 10.1046/j.1525-1403.2000.00043.xCrossRefPubMed Jensen W, Riso R, Sinkjaer T: Effect of intertrial delay on whole nerve cuff recordings of muscle afferents in rabbits. Neuromodulation 2000, 3: 43-53. 10.1046/j.1525-1403.2000.00043.xCrossRefPubMed
38.
go back to reference Tesfayesus W, Durand DM: Blind source separation of peripheral nerve recordings. J Neural Eng 2007, 4: 157-167. 10.1088/1741-2560/4/3/S03CrossRef Tesfayesus W, Durand DM: Blind source separation of peripheral nerve recordings. J Neural Eng 2007, 4: 157-167. 10.1088/1741-2560/4/3/S03CrossRef
39.
go back to reference Zariffa J, Nagai MK, Daskalakis ZJ, Popovic MR: Influence of the number and location of recording contacts on the selectivity of a nerve cuff electrode. IEEE Trans Neural Syst Rehabil Eng 2009, 17: 420-427. 10.1109/TNSRE.2009.2023301CrossRefPubMed Zariffa J, Nagai MK, Daskalakis ZJ, Popovic MR: Influence of the number and location of recording contacts on the selectivity of a nerve cuff electrode. IEEE Trans Neural Syst Rehabil Eng 2009, 17: 420-427. 10.1109/TNSRE.2009.2023301CrossRefPubMed
40.
go back to reference Dhillon GS, Horch KW: Direct neural sensory feedback and control of a prosthetic arm. IEEE Trans Neural Syst Rehabil Eng 2005, 13: 468-472. 10.1109/TNSRE.2005.856072CrossRefPubMed Dhillon GS, Horch KW: Direct neural sensory feedback and control of a prosthetic arm. IEEE Trans Neural Syst Rehabil Eng 2005, 13: 468-472. 10.1109/TNSRE.2005.856072CrossRefPubMed
41.
go back to reference Micera S, Navarro X, Carpaneto J, Citi L, Tonet O, Rossini PM, Carrozza MC, Hoffmann KP, Vivò M, Yoshida K, Dario P: On the use of longitudinal intrafascicular peripheral interfaces for the control of cybernetic hand prostheses in amputees. IEEE Trans Neural Syst Rehabil Eng 2008, 16: 453-472. 10.1109/TNSRE.2008.2006207CrossRefPubMed Micera S, Navarro X, Carpaneto J, Citi L, Tonet O, Rossini PM, Carrozza MC, Hoffmann KP, Vivò M, Yoshida K, Dario P: On the use of longitudinal intrafascicular peripheral interfaces for the control of cybernetic hand prostheses in amputees. IEEE Trans Neural Syst Rehabil Eng 2008, 16: 453-472. 10.1109/TNSRE.2008.2006207CrossRefPubMed
42.
go back to reference Pachnis I, Demosthenous A, Donaldson N: Passive neutralization of myoelectric interference from neural recording tripoles. IEEE Trans Biomed Eng 2007, 54: 1067-1074. 10.1109/TBME.2007.891170CrossRefPubMed Pachnis I, Demosthenous A, Donaldson N: Passive neutralization of myoelectric interference from neural recording tripoles. IEEE Trans Biomed Eng 2007, 54: 1067-1074. 10.1109/TBME.2007.891170CrossRefPubMed
43.
go back to reference Bossi S, Menciassi A, Koch KP, Hoffmann KP, Yoshida K, Dario P, Micera S: Shape Memory Alloy Microactuation of tf-LIFEs: Preliminary Result. IEEE Trans Biomed Eng 2007, 54: 1115-1120. 10.1109/TBME.2007.895186CrossRefPubMed Bossi S, Menciassi A, Koch KP, Hoffmann KP, Yoshida K, Dario P, Micera S: Shape Memory Alloy Microactuation of tf-LIFEs: Preliminary Result. IEEE Trans Biomed Eng 2007, 54: 1115-1120. 10.1109/TBME.2007.895186CrossRefPubMed
Metadata
Title
On the identification of sensory information from mixed nerves by using single-channel cuff electrodes
Authors
Stanisa Raspopovic
Jacopo Carpaneto
Esther Udina
Xavier Navarro
Silvestro Micera
Publication date
01-12-2010
Publisher
BioMed Central
Published in
Journal of NeuroEngineering and Rehabilitation / Issue 1/2010
Electronic ISSN: 1743-0003
DOI
https://doi.org/10.1186/1743-0003-7-17

Other articles of this Issue 1/2010

Journal of NeuroEngineering and Rehabilitation 1/2010 Go to the issue