Abstract

Background

Measurements of range of motion play a key role in shoulder research. The purpose of this study is to investigate intra-observer reproducibility of measurements of active and passive range of motion in patients with adhesive capsulitis.

Methods

The study was carried out in a population consisting of 32 patients with clinical signs of adhesive capsulitis. A specified measurement protocol was used, and range of motion in affected and non-affected shoulders was measured twice for each patient with a one-week interval.

Results

For most of the investigated individual movements, test-retest differences in range of motion score of more than approximately 15° are not likely to occur as a result of measurement error only. Point-estimates for the intraclass correlation coefficient ranged from 0.61 to 0.93.

Conclusion

Range of motion of patients with adhesive capsulitis can be measured with acceptable reproducibility in settings where groups are compared. Scores for individual patients should be interpreted with caution.
Appendix
Available only for authorised users
Literature
1.
go back to reference Green S, Buchbinder R, Glazier R, Forbes A: Interventions for shoulder pain. The Cochrane Library. 2002, 3 Green S, Buchbinder R, Glazier R, Forbes A: Interventions for shoulder pain. The Cochrane Library. 2002, 3
2.
go back to reference Clarke GR, Willis LA, Fish WW, Nichols PJR: Assessment of movement at the gleno-humeral joint. Orthopaedics. 1974, 7: 55-71. Clarke GR, Willis LA, Fish WW, Nichols PJR: Assessment of movement at the gleno-humeral joint. Orthopaedics. 1974, 7: 55-71.
3.
go back to reference De Winter AF, Heemskerk MAMB, Terwee CB, Jans MP, Devillé W, van Schaardenburg DJ, Scholten RJPM, Bouter LM: Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer. BMC Musculoskelet Disord. 2004, 5: 18-10.1186/1471-2474-5-18.CrossRefPubMedPubMedCentral De Winter AF, Heemskerk MAMB, Terwee CB, Jans MP, Devillé W, van Schaardenburg DJ, Scholten RJPM, Bouter LM: Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer. BMC Musculoskelet Disord. 2004, 5: 18-10.1186/1471-2474-5-18.CrossRefPubMedPubMedCentral
4.
go back to reference MacDermid JC, Chesworth BM, Patterson S, Roth JH: Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotation. J Hand Ther. 1999, 12: 187-192.CrossRefPubMed MacDermid JC, Chesworth BM, Patterson S, Roth JH: Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotation. J Hand Ther. 1999, 12: 187-192.CrossRefPubMed
5.
go back to reference Gajdosik RL, Bohannon RW: Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity. Phys Ther. 1987, 67: 1867-1872.PubMed Gajdosik RL, Bohannon RW: Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity. Phys Ther. 1987, 67: 1867-1872.PubMed
6.
go back to reference Shaffer B, Tibone JE, Kerlan RK: Frozen shoulder. A long-term follow-up. J Bone Joint Surg. 1992, 74: 738-746.PubMed Shaffer B, Tibone JE, Kerlan RK: Frozen shoulder. A long-term follow-up. J Bone Joint Surg. 1992, 74: 738-746.PubMed
7.
go back to reference Geertzen JHB, Dijkstra PU, Stewart RE, Groothoff JW, Duis HJT, Eisma WH: Variation of measurements of range of motion: A study in reflex sympathetic dystrophy patients. Clin Rehabil. 1998, 12: 254-264. 10.1191/026921598675343181.CrossRefPubMed Geertzen JHB, Dijkstra PU, Stewart RE, Groothoff JW, Duis HJT, Eisma WH: Variation of measurements of range of motion: A study in reflex sympathetic dystrophy patients. Clin Rehabil. 1998, 12: 254-264. 10.1191/026921598675343181.CrossRefPubMed
8.
go back to reference Triffitt PD, Wildin C, Hajioff D: The reproducibility of measurement of shoulder movement. Acta Orthop Scand. 1999, 70: 322-324.CrossRefPubMed Triffitt PD, Wildin C, Hajioff D: The reproducibility of measurement of shoulder movement. Acta Orthop Scand. 1999, 70: 322-324.CrossRefPubMed
9.
go back to reference Hayes K, Walton JR, Szomor ZL, Murrell GAC: Reliability of five methods for assessing shoulder range of motion. Austr J Physiother. 2001, 47: 289-294.CrossRef Hayes K, Walton JR, Szomor ZL, Murrell GAC: Reliability of five methods for assessing shoulder range of motion. Austr J Physiother. 2001, 47: 289-294.CrossRef
10.
go back to reference Hannafin JA, Chiaia TA: Adhesive Capsulitis: A treatment approach. Clin Orthop. 2000, 372: 95-109. 10.1097/00003086-200003000-00012.CrossRefPubMed Hannafin JA, Chiaia TA: Adhesive Capsulitis: A treatment approach. Clin Orthop. 2000, 372: 95-109. 10.1097/00003086-200003000-00012.CrossRefPubMed
11.
go back to reference Roach KE, Budiman-Mak E, Songsiridej N, Lertratanakul : Development of a shoulder pain and disability index. Arthritis Care Res. 1991, 4: 143-149. 10.1002/art.1790040403.CrossRefPubMed Roach KE, Budiman-Mak E, Songsiridej N, Lertratanakul : Development of a shoulder pain and disability index. Arthritis Care Res. 1991, 4: 143-149. 10.1002/art.1790040403.CrossRefPubMed
12.
go back to reference Juel NG: Norsk fysikalsk medisin. 2007, Oslo: Fagbokforlaget, 71- Juel NG: Norsk fysikalsk medisin. 2007, Oslo: Fagbokforlaget, 71-
13.
go back to reference Croft P, Pope D, Boswell R, Rigby A, Silman A: Observer variability in measuring elevation and external rotation of the shoulder. Br J Rheumatol. 1994, 33: 942-946. 10.1093/rheumatology/33.10.942.CrossRefPubMed Croft P, Pope D, Boswell R, Rigby A, Silman A: Observer variability in measuring elevation and external rotation of the shoulder. Br J Rheumatol. 1994, 33: 942-946. 10.1093/rheumatology/33.10.942.CrossRefPubMed
14.
go back to reference Terwee CB, de Winter AF, Scholten RJ, Jans MP, Devillé W, van Schaardenburg D, Bouter LM: Interobserver reproducibility of the visual estimation of range of motion of the shoulder. Arch Phys Med Rehabil. 2005, 86: 1356-1361. 10.1016/j.apmr.2004.12.031.CrossRefPubMed Terwee CB, de Winter AF, Scholten RJ, Jans MP, Devillé W, van Schaardenburg D, Bouter LM: Interobserver reproducibility of the visual estimation of range of motion of the shoulder. Arch Phys Med Rehabil. 2005, 86: 1356-1361. 10.1016/j.apmr.2004.12.031.CrossRefPubMed
15.
go back to reference Williams JG, Callaghan M: Comparison of visual estimation and goniometry in determination of a shoulder joint angle. Physiotherapy. 1990, 76: 655-657.CrossRef Williams JG, Callaghan M: Comparison of visual estimation and goniometry in determination of a shoulder joint angle. Physiotherapy. 1990, 76: 655-657.CrossRef
16.
go back to reference Boon AJ, Smith J: Manual scapular stabilization: its effect on shoulder rotational range of motion. Arch Phys Med Rehabil. 2000, 81: 978-983. 10.1053/apmr.2000.5617.CrossRefPubMed Boon AJ, Smith J: Manual scapular stabilization: its effect on shoulder rotational range of motion. Arch Phys Med Rehabil. 2000, 81: 978-983. 10.1053/apmr.2000.5617.CrossRefPubMed
17.
go back to reference Boone DC, Azen SP, Lin C-M, Spence C, Baron C, Lee L: Reliability of goniometric measurements. Phys Ther. 1978, 58: 1355-1360.PubMed Boone DC, Azen SP, Lin C-M, Spence C, Baron C, Lee L: Reliability of goniometric measurements. Phys Ther. 1978, 58: 1355-1360.PubMed
18.
go back to reference Bovens AM, van Baak MA, Vrencken JC, Wijnen JA, Verstappen FT: Variability and reliability of joint measurements. Am J Sports Med. 1990, 18: 58-63. 10.1177/036354659001800110.CrossRefPubMed Bovens AM, van Baak MA, Vrencken JC, Wijnen JA, Verstappen FT: Variability and reliability of joint measurements. Am J Sports Med. 1990, 18: 58-63. 10.1177/036354659001800110.CrossRefPubMed
19.
go back to reference Riddle DL, Rothstein JM, Lamb RL: Goniometric reliability in a clinical setting. Shoulder measurements. Phys Ther. 1987, 67: 668-673.PubMed Riddle DL, Rothstein JM, Lamb RL: Goniometric reliability in a clinical setting. Shoulder measurements. Phys Ther. 1987, 67: 668-673.PubMed
20.
go back to reference Sabari JS, Maltzev I, Lubarsky D, Liszkay E, Hemel P: Goniometric assessment of shoulder range of motion: comparison of testing in supine and sitting positions. Arch Phys Med Rehabil. 1998, 79: 647-651. 10.1016/S0003-9993(98)90038-7.CrossRefPubMed Sabari JS, Maltzev I, Lubarsky D, Liszkay E, Hemel P: Goniometric assessment of shoulder range of motion: comparison of testing in supine and sitting positions. Arch Phys Med Rehabil. 1998, 79: 647-651. 10.1016/S0003-9993(98)90038-7.CrossRefPubMed
21.
go back to reference Jordan K, Dziedzic K, Jones PW, Ong BN, Dawes PT: The reliability of the three-dimensional FASTRAK measurement system in measuring cervical spine and shoulder range of motion in healthy subjects. Rheumatology. 2000, 39: 382-388. 10.1093/rheumatology/39.4.382.CrossRefPubMed Jordan K, Dziedzic K, Jones PW, Ong BN, Dawes PT: The reliability of the three-dimensional FASTRAK measurement system in measuring cervical spine and shoulder range of motion in healthy subjects. Rheumatology. 2000, 39: 382-388. 10.1093/rheumatology/39.4.382.CrossRefPubMed
22.
go back to reference Buchbinder R, Green S, Forbes A, Hall S, Lawler G: Arthrographic joint distension with saline and steroid improves function and reduces pain in patients with painful stiff shoulder: results of a randomised, double blind, placebo controlled trial. Ann Rheum Dis. 2004, 63: 302-309. 10.1136/ard.2002.004655.CrossRefPubMedPubMedCentral Buchbinder R, Green S, Forbes A, Hall S, Lawler G: Arthrographic joint distension with saline and steroid improves function and reduces pain in patients with painful stiff shoulder: results of a randomised, double blind, placebo controlled trial. Ann Rheum Dis. 2004, 63: 302-309. 10.1136/ard.2002.004655.CrossRefPubMedPubMedCentral
23.
go back to reference Buchbinder R, Hoving JL, Green S, Hall S, Forbes A, Nash P: Short course prednisolone for adhesive capsulitis (frozen shoulder or stiff painful shoulder): a randomised, double blind, placebo controlled trial. Ann Rheum Dis. 2004, 63: 1460-1469. 10.1136/ard.2003.018218.CrossRefPubMedPubMedCentral Buchbinder R, Hoving JL, Green S, Hall S, Forbes A, Nash P: Short course prednisolone for adhesive capsulitis (frozen shoulder or stiff painful shoulder): a randomised, double blind, placebo controlled trial. Ann Rheum Dis. 2004, 63: 1460-1469. 10.1136/ard.2003.018218.CrossRefPubMedPubMedCentral
24.
go back to reference Carette S, Moffet H, Tardif J, Bessette L, Morin F, Frémont P, Bykerk V, Thorne C, Bell M, Bensen W, Blanchette C: Intraarticular corticosteroids, supervised physiotherapy, or a combination of the two in the treatment of adhesive capsulitis of the shoulder: A placebo-controlled trial. Arthritis & Rheumatism. 2003, 48: 829-838. 10.1002/art.10954.CrossRef Carette S, Moffet H, Tardif J, Bessette L, Morin F, Frémont P, Bykerk V, Thorne C, Bell M, Bensen W, Blanchette C: Intraarticular corticosteroids, supervised physiotherapy, or a combination of the two in the treatment of adhesive capsulitis of the shoulder: A placebo-controlled trial. Arthritis & Rheumatism. 2003, 48: 829-838. 10.1002/art.10954.CrossRef
25.
go back to reference Van Royen BJ, Pavlov P: Treatment of frozen shoulder by distension and manipulation under local anaesthesia. Int Orthop. 1996, 20: 207-210. 10.1007/s002640050064.CrossRefPubMed Van Royen BJ, Pavlov P: Treatment of frozen shoulder by distension and manipulation under local anaesthesia. Int Orthop. 1996, 20: 207-210. 10.1007/s002640050064.CrossRefPubMed
26.
go back to reference Awan R, Smith J, Boon AJ: Measuring shoulder internal rotation range of motion: A comparison of 3 techniques. Arch Phys Med Rehab. 2002, 83: 1229-1234. 10.1053/apmr.2002.34815.CrossRef Awan R, Smith J, Boon AJ: Measuring shoulder internal rotation range of motion: A comparison of 3 techniques. Arch Phys Med Rehab. 2002, 83: 1229-1234. 10.1053/apmr.2002.34815.CrossRef
27.
go back to reference Green S, Buchbinder R, Forbes A, Bellamy N: A standardized protocol for measurement of range of movement of the shoulder using the Plurimeter-V inclinometer and assessment of its intrarater and interrater reliability. Arthritis Care Res. 1998, 11: 43-52. 10.1002/art.1790110108.CrossRefPubMed Green S, Buchbinder R, Forbes A, Bellamy N: A standardized protocol for measurement of range of movement of the shoulder using the Plurimeter-V inclinometer and assessment of its intrarater and interrater reliability. Arthritis Care Res. 1998, 11: 43-52. 10.1002/art.1790110108.CrossRefPubMed
28.
go back to reference Hoving JL, Buchbinder R, Green S, Forbes A, Bellamy N, Brand C, Buchanan R, Hall S, Patrick M, Ryan P, Stockman A: How reliably do rheumatologists measure shoulder movement?. Ann Rheum Dis. 2002, 61: 612-616. 10.1136/ard.61.7.612.CrossRefPubMedPubMedCentral Hoving JL, Buchbinder R, Green S, Forbes A, Bellamy N, Brand C, Buchanan R, Hall S, Patrick M, Ryan P, Stockman A: How reliably do rheumatologists measure shoulder movement?. Ann Rheum Dis. 2002, 61: 612-616. 10.1136/ard.61.7.612.CrossRefPubMedPubMedCentral
29.
go back to reference Bower K: The hydrogoniometer and assessment of gleno-humeral joint motion. Aus J Physiother. 1992, 28: 12-17.CrossRef Bower K: The hydrogoniometer and assessment of gleno-humeral joint motion. Aus J Physiother. 1992, 28: 12-17.CrossRef
30.
go back to reference Reeves B: The natural history of the frozen shoulder syndrome. Scand J Rheumatol. 1975, 4: 193-196.CrossRefPubMed Reeves B: The natural history of the frozen shoulder syndrome. Scand J Rheumatol. 1975, 4: 193-196.CrossRefPubMed
31.
go back to reference Dvir Z, Gal-Eshel N, Shamir B, Prushansky T, Pevzner E, Peretz C: Cervical motion in patients with chronic disorders of the cervical spine: a reproducibility study. Spine. 2006, 31: E394-399. 10.1097/01.brs.0000219951.79922.df.CrossRefPubMed Dvir Z, Gal-Eshel N, Shamir B, Prushansky T, Pevzner E, Peretz C: Cervical motion in patients with chronic disorders of the cervical spine: a reproducibility study. Spine. 2006, 31: E394-399. 10.1097/01.brs.0000219951.79922.df.CrossRefPubMed
32.
go back to reference De Vet HC, Terwee CB, Bouter LM: Current challenges in clinimetrics. J Clin Epidemiol. 2003, 56: 1137-1141. 10.1016/j.jclinepi.2003.08.012.CrossRefPubMed De Vet HC, Terwee CB, Bouter LM: Current challenges in clinimetrics. J Clin Epidemiol. 2003, 56: 1137-1141. 10.1016/j.jclinepi.2003.08.012.CrossRefPubMed
34.
go back to reference Atkinson G, Nevill AM: Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med. 1998, 26: 217-238. 10.2165/00007256-199826040-00002.CrossRefPubMed Atkinson G, Nevill AM: Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med. 1998, 26: 217-238. 10.2165/00007256-199826040-00002.CrossRefPubMed
35.
go back to reference Shrout PE, Fleiss JL: Intraclass correlations: Uses in assessing rater reliability. Psychol Bull. 1979, 86: 420-428. 10.1037/0033-2909.86.2.420.CrossRefPubMed Shrout PE, Fleiss JL: Intraclass correlations: Uses in assessing rater reliability. Psychol Bull. 1979, 86: 420-428. 10.1037/0033-2909.86.2.420.CrossRefPubMed
36.
go back to reference Ellenbecker TS, Roetert EP, Piorkowski PA, Schulz DA: Glenohumeral joint internal and external rotation range of motion in elite junior tennis players. J Orthopaedic Sports Phys Ther. 1996, 24: 336-341.CrossRef Ellenbecker TS, Roetert EP, Piorkowski PA, Schulz DA: Glenohumeral joint internal and external rotation range of motion in elite junior tennis players. J Orthopaedic Sports Phys Ther. 1996, 24: 336-341.CrossRef
37.
go back to reference Boström C, Harms-Ringdahl K, Nordemar R: Clinical reliability of shoulder function assessment in patients with rheumatoid arthritis. Scand J Rheumatol. 1991, 20: 36-48.CrossRefPubMed Boström C, Harms-Ringdahl K, Nordemar R: Clinical reliability of shoulder function assessment in patients with rheumatoid arthritis. Scand J Rheumatol. 1991, 20: 36-48.CrossRefPubMed
38.
go back to reference Rousson V, Gasser T, Seifert B: Assessing intrarater, interrater and test-retest reliability of continuous measurements. Stat Med. 2002, 21: 3431-3446. 10.1002/sim.1253.CrossRefPubMed Rousson V, Gasser T, Seifert B: Assessing intrarater, interrater and test-retest reliability of continuous measurements. Stat Med. 2002, 21: 3431-3446. 10.1002/sim.1253.CrossRefPubMed
Metadata
Title
Range of shoulder motion in patients with adhesive capsulitis; Intra-tester reproducibility is acceptable for group comparisons
Authors
Einar Kristian Tveitå
Ole Marius Ekeberg
Niels Gunnar Juel
Erik Bautz-Holter
Publication date
01-12-2008
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2008
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-9-49

Other articles of this Issue 1/2008

BMC Musculoskeletal Disorders 1/2008 Go to the issue