The reliability of a 10-test package for patients with prolonged back and neck pain: could an examiner without formal medical education be used without loss of quality? A methodological study

Authors: Odd Lindell, Lars Eriksson, Lars-Erik Strender

Published in: BMC Musculoskeletal Disorders | Issue 1/2007

Login to get access

Abstract

Background

In the rehabilitation of patients with prolonged back and neck pain, the physical impairment should be assessed. Previous research has exclusively engaged medically educated examiners, mostly physiotherapists. However, less biased evaluations of efforts at rehabilitation might be achieved by personnel standing outside the treatment work itself. Therefore, if medically untrained examiners could be used without cost to the quality, this might produce a better evaluation at defensible cost and could also be useful in a research context. The aim of this study was to answer the question: given a 10-test package for patients with prolonged back and neck pain, could an examiner without formal medical education be used without loss of quality? Five of the ten tests required the examiner to keep a firm hold against the foundation of those parts of the participant's body that were not supposed to move during the test.

Methods

Examination by an experienced physiotherapist (A) in performing the package was compared with that by a research assistant (B) without formal medical education. The reliability, including inter- and intra-rater reliability, was assessed. In the inter-rater reliability study, 50 participants (30 patients + 20 healthy subjects) were tested once each by A and B. In the intra-rater reliability study, the 20 healthy subjects were tested twice by A or B. One-way ANOVA intra-class-correlation coefficient (ICC) was calculated and its possible systematic error was determined using a t-test.

Results

All five tests that required no manual fixation had acceptable reliability (ICC > .60 and no indication of systematic error). Only one of the five tests that required fixation had acceptable reliability. The difference (five vs. one) was significant (p = .01).

Conclusion

In a 10-test package for patients with prolonged back and neck pain, an examiner without formal medical education could be used without loss of quality, at least for the five tests requiring no manual fixation. To make our results more generalizable and their implications more searching, a similar study should be conducted with two or more examiners with and without formal medical education, and the intra-rater reliability study should also include patients and involve more participants.
Appendix
Available only for authorised users
Literature
1.
go back to reference Alexanderson K, Norlund A, (editors): SBU summary and conclusions. Sickness absence – causes, consequences, and physicians' sickness-certification practice. A systematic literature review by the Swedish Council on Technology Assessment in Health Care. Scand J Public Health. Edited by: Alexanderson K, Norlund A. 2004, 6-11. Suppl 63 Alexanderson K, Norlund A, (editors): SBU summary and conclusions. Sickness absence – causes, consequences, and physicians' sickness-certification practice. A systematic literature review by the Swedish Council on Technology Assessment in Health Care. Scand J Public Health. Edited by: Alexanderson K, Norlund A. 2004, 6-11. Suppl 63
2.
go back to reference Waddell G, Main CJ: Assessment of severity in low back disorders. Spine. 1984, 9: 204-208. 10.1097/00007632-198403000-00012.CrossRefPubMed Waddell G, Main CJ: Assessment of severity in low back disorders. Spine. 1984, 9: 204-208. 10.1097/00007632-198403000-00012.CrossRefPubMed
3.
go back to reference Waddell G: Diagnostic triage. Back Pain Revolution. Edited by: Waddell G. 2004, Edinburgh: Churchill Livingstone, 9-26. 2 Waddell G: Diagnostic triage. Back Pain Revolution. Edited by: Waddell G. 2004, Edinburgh: Churchill Livingstone, 9-26. 2
4.
go back to reference Ljungquist T, Harms-Ringdahl K, Nygren A, Jensen I: Intra- and inter-rater reliability of an 11-test package for assessing dysfunction due to back or neck pain. Physiother Res Int. 1999, 4: 214-232. 10.1002/pri.167.CrossRefPubMed Ljungquist T, Harms-Ringdahl K, Nygren A, Jensen I: Intra- and inter-rater reliability of an 11-test package for assessing dysfunction due to back or neck pain. Physiother Res Int. 1999, 4: 214-232. 10.1002/pri.167.CrossRefPubMed
5.
go back to reference Task force on standards for measurement in physical therapy. Standards for tests and measurements in physical therapy practice. Phys Ther. 1991, 71: 589-622. Task force on standards for measurement in physical therapy. Standards for tests and measurements in physical therapy practice. Phys Ther. 1991, 71: 589-622.
6.
go back to reference Biering-Sørensen F: Physical measurements as risk indicators for low-back trouble over a one-year period. Spine. 1984, 9: 106-109. 10.1097/00007632-198403000-00002.CrossRefPubMed Biering-Sørensen F: Physical measurements as risk indicators for low-back trouble over a one-year period. Spine. 1984, 9: 106-109. 10.1097/00007632-198403000-00002.CrossRefPubMed
7.
go back to reference Mellin G: Accuracy of measuring lateral flexion of the spine with a tape. Clin Biomech. 1986, 1: 85-89. 10.1016/0268-0033(86)90081-1.CrossRef Mellin G: Accuracy of measuring lateral flexion of the spine with a tape. Clin Biomech. 1986, 1: 85-89. 10.1016/0268-0033(86)90081-1.CrossRef
8.
go back to reference Lindström I, Öhlund C, Eek C, Wallin L, Petersen LE, Nachemson A: Mobility, strength and fitness after a graded activity program for patients with subacute low back pain. Spine. 1992, 17: 641-652.CrossRefPubMed Lindström I, Öhlund C, Eek C, Wallin L, Petersen LE, Nachemson A: Mobility, strength and fitness after a graded activity program for patients with subacute low back pain. Spine. 1992, 17: 641-652.CrossRefPubMed
9.
go back to reference Capuano-Pucci D, Rheault W, Aukai J, Bracke M, Day R, Pastrick M: Intratester and intertester reliability of the cervical range of motion device. Arch Phys Med Rehabil. 1991, 72: 338-340.PubMed Capuano-Pucci D, Rheault W, Aukai J, Bracke M, Day R, Pastrick M: Intratester and intertester reliability of the cervical range of motion device. Arch Phys Med Rehabil. 1991, 72: 338-340.PubMed
10.
go back to reference Rheault W, Albright B, Byers C, Franta M, Johnson A, Skowronek M, Dougherty J: Intertester reliability of the cervical range of motion device. J Orthop Sports Phys Ther. 1992, 15: 147-150.CrossRefPubMed Rheault W, Albright B, Byers C, Franta M, Johnson A, Skowronek M, Dougherty J: Intertester reliability of the cervical range of motion device. J Orthop Sports Phys Ther. 1992, 15: 147-150.CrossRefPubMed
11.
go back to reference Hyytiäinen K, Salminen JJ, Suvitie T, Wickström G, Pentti J: Reproducibility of nine tests to measure spinal mobility and trunk muscle strength. Scand J Rehabil Med. 1991, 23: 3-10.PubMed Hyytiäinen K, Salminen JJ, Suvitie T, Wickström G, Pentti J: Reproducibility of nine tests to measure spinal mobility and trunk muscle strength. Scand J Rehabil Med. 1991, 23: 3-10.PubMed
12.
go back to reference Moreau CE, Green BN, Johnson CD, Moreau SR: Isometric back extension endurance tests: A review of the literature. J Manipulative Physiol Ther. 2001, 24: 110-122. 10.1067/mmt.2001.112563.CrossRefPubMed Moreau CE, Green BN, Johnson CD, Moreau SR: Isometric back extension endurance tests: A review of the literature. J Manipulative Physiol Ther. 2001, 24: 110-122. 10.1067/mmt.2001.112563.CrossRefPubMed
13.
go back to reference Horneij E, Holmström E, Hemborg B, Isberg PE, Ekdahl C: Inter-rater reliability and between-days repeatability of eight physical performance tests. Adv Physiother. 2002, 4: 146-160. 10.1080/14038190260501596.CrossRef Horneij E, Holmström E, Hemborg B, Isberg PE, Ekdahl C: Inter-rater reliability and between-days repeatability of eight physical performance tests. Adv Physiother. 2002, 4: 146-160. 10.1080/14038190260501596.CrossRef
14.
go back to reference Hawk C, Phongphua C, Bleecker J, Swank L, Lopez D, Rubley T: Preliminary study of the reliability of assessment procedures for indications for chiropractic adjustments of the lumbar spine. J Manipulative Physiol Ther. 1999, 22: 382-389. 10.1016/S0161-4754(99)70083-7.CrossRefPubMed Hawk C, Phongphua C, Bleecker J, Swank L, Lopez D, Rubley T: Preliminary study of the reliability of assessment procedures for indications for chiropractic adjustments of the lumbar spine. J Manipulative Physiol Ther. 1999, 22: 382-389. 10.1016/S0161-4754(99)70083-7.CrossRefPubMed
15.
go back to reference Bertilson BC, Grunnesjö M, Strender LE: Reliability of clinical tests in the assessment of patients with neck/shoulder problems – impact of history. Spine. 2003, 28: 2222-2231. 10.1097/01.BRS.0000089685.55629.2E.CrossRefPubMed Bertilson BC, Grunnesjö M, Strender LE: Reliability of clinical tests in the assessment of patients with neck/shoulder problems – impact of history. Spine. 2003, 28: 2222-2231. 10.1097/01.BRS.0000089685.55629.2E.CrossRefPubMed
16.
go back to reference Mayer TG, Barnes D, Nichols G, Kishino ND, Coval K, Piel B, Hoshino D, Gatchel RJ: Progressiv isoinertial lifting evaluation. II. A comparison with isokinetic lifting in a disabled chronic low-back pain industrial population. Spine. 1988, 13: 998-1002. 10.1097/00007632-198809000-00006.CrossRefPubMed Mayer TG, Barnes D, Nichols G, Kishino ND, Coval K, Piel B, Hoshino D, Gatchel RJ: Progressiv isoinertial lifting evaluation. II. A comparison with isokinetic lifting in a disabled chronic low-back pain industrial population. Spine. 1988, 13: 998-1002. 10.1097/00007632-198809000-00006.CrossRefPubMed
17.
go back to reference Nitschke JE, Nattrass CL, Disler PB, Chou MJ, Ooi KT: Reliability of the American Medical Association Guides' model for measuring spinal range of motion. Its implication for whole-person impairment rating. Spine. 1999, 24: 262-268. 10.1097/00007632-199902010-00013.CrossRefPubMed Nitschke JE, Nattrass CL, Disler PB, Chou MJ, Ooi KT: Reliability of the American Medical Association Guides' model for measuring spinal range of motion. Its implication for whole-person impairment rating. Spine. 1999, 24: 262-268. 10.1097/00007632-199902010-00013.CrossRefPubMed
18.
go back to reference Strender LE, Sjöblom A, Sundell K, Ludwig R, Taube A: Interexaminer reliability in physical examination of patients with low back pain. Spine. 1997, 22: 814-820. 10.1097/00007632-199704010-00021.CrossRefPubMed Strender LE, Sjöblom A, Sundell K, Ludwig R, Taube A: Interexaminer reliability in physical examination of patients with low back pain. Spine. 1997, 22: 814-820. 10.1097/00007632-199704010-00021.CrossRefPubMed
19.
go back to reference Keeley J, Mayer T, Cox R, Gatchel R, Smith V, Mooney V: Quantification of lumbar function. Part 5: Reliability of range-of-motion measures in the sagittal plane and an in vivo torso rotation measurements technique. Spine. 1986, 11: 31-35. 10.1097/00007632-198601000-00009.CrossRefPubMed Keeley J, Mayer T, Cox R, Gatchel R, Smith V, Mooney V: Quantification of lumbar function. Part 5: Reliability of range-of-motion measures in the sagittal plane and an in vivo torso rotation measurements technique. Spine. 1986, 11: 31-35. 10.1097/00007632-198601000-00009.CrossRefPubMed
20.
go back to reference Binkley J, Stratford PW, Gill C: Interrater reliability of lumbar accessory motion mobility testing. Phys Ther. 1995, 75: 786-795.PubMed Binkley J, Stratford PW, Gill C: Interrater reliability of lumbar accessory motion mobility testing. Phys Ther. 1995, 75: 786-795.PubMed
21.
go back to reference Fjellner A, Bexander C, Faleij R, Strender LE: Interexaminer reliability in physical examination of the cervical spine. J Manipulative Physiol Ther. 1999, 22: 511-516. 10.1016/S0161-4754(99)70002-3.CrossRefPubMed Fjellner A, Bexander C, Faleij R, Strender LE: Interexaminer reliability in physical examination of the cervical spine. J Manipulative Physiol Ther. 1999, 22: 511-516. 10.1016/S0161-4754(99)70002-3.CrossRefPubMed
23.
go back to reference Borg G: Psychophysical bases of perceived exertion. Med Sci Sports Exerc. 1982, 14: 377-382.PubMed Borg G: Psychophysical bases of perceived exertion. Med Sci Sports Exerc. 1982, 14: 377-382.PubMed
24.
go back to reference Borg G: A category scale with ratio properties for inter-modal and inter-individual comparison. 1982, Berlin: VEB Deutscher Verlag der Wissenschaften, 25-34. Borg G: A category scale with ratio properties for inter-modal and inter-individual comparison. 1982, Berlin: VEB Deutscher Verlag der Wissenschaften, 25-34.
25.
go back to reference Bland JM, Altman DG: Comparing two methods of clinical measurement: A personal history. Int J Epidemiol. 1995, 7-14. Suppl 7 Bland JM, Altman DG: Comparing two methods of clinical measurement: A personal history. Int J Epidemiol. 1995, 7-14. Suppl 7
26.
go back to reference Moreland J, Finch E, Stratford P, Balsor B, Gill C: Interrater reliability of six tests of trunk muscle function and endurance. J Orthop Sports Phys Ther. 1997, 26: 200-208.CrossRefPubMed Moreland J, Finch E, Stratford P, Balsor B, Gill C: Interrater reliability of six tests of trunk muscle function and endurance. J Orthop Sports Phys Ther. 1997, 26: 200-208.CrossRefPubMed
27.
go back to reference Valentine RE, Lewis JS: Intraobserver reliability of 4 physiologic movements of the shoulder in subjects with and without symptom. Arch Phys Med Rehabil. 2006, 87: 1242-1249. 10.1016/j.apmr.2006.05.008.CrossRefPubMed Valentine RE, Lewis JS: Intraobserver reliability of 4 physiologic movements of the shoulder in subjects with and without symptom. Arch Phys Med Rehabil. 2006, 87: 1242-1249. 10.1016/j.apmr.2006.05.008.CrossRefPubMed
28.
go back to reference Haas M: Statistical methodology for reliability studies. J Manipulative Physiol Ther. 1991, 14: 119-132.PubMed Haas M: Statistical methodology for reliability studies. J Manipulative Physiol Ther. 1991, 14: 119-132.PubMed
29.
go back to reference Rosner M: Multisample inference. Fundamental of biostatistics. 2000, Duxbury: Thomson Learning, 511-576. 5 Rosner M: Multisample inference. Fundamental of biostatistics. 2000, Duxbury: Thomson Learning, 511-576. 5
30.
go back to reference Landis JR, Koch GG: The measurement of observer agreement for categorical data. Biometrics. 1977, 33: 159-174. 10.2307/2529310.CrossRefPubMed Landis JR, Koch GG: The measurement of observer agreement for categorical data. Biometrics. 1977, 33: 159-174. 10.2307/2529310.CrossRefPubMed
32.
go back to reference Altman DG: Comparing groups – categorical data. Practical statistics for medical research. 1991, London: Chapman & Hall, 229-276. 1 Altman DG: Comparing groups – categorical data. Practical statistics for medical research. 1991, London: Chapman & Hall, 229-276. 1
33.
go back to reference Bland JM, Altman DG: Measuring agreement in method comparison studies. Stat Methods Med Res. 1999, 8: 135-160. 10.1191/096228099673819272.CrossRefPubMed Bland JM, Altman DG: Measuring agreement in method comparison studies. Stat Methods Med Res. 1999, 8: 135-160. 10.1191/096228099673819272.CrossRefPubMed
34.
go back to reference Altman DG: Comparing groups – continous data. Practical statistics for medical research. 1991, London: Chapman & Hall, 179-228. 1 Altman DG: Comparing groups – continous data. Practical statistics for medical research. 1991, London: Chapman & Hall, 179-228. 1
35.
go back to reference Hendriks EJM, Brandsma JW, Heerkens YF, Oostendorp RAB, Nelson RM: Intraobserver and interobserver reliability of assessments of impairments and disabilities. Phys Ther. 1997, 77: 1097-1106.PubMed Hendriks EJM, Brandsma JW, Heerkens YF, Oostendorp RAB, Nelson RM: Intraobserver and interobserver reliability of assessments of impairments and disabilities. Phys Ther. 1997, 77: 1097-1106.PubMed
Metadata
Title
The reliability of a 10-test package for patients with prolonged back and neck pain: could an examiner without formal medical education be used without loss of quality? A methodological study
Authors
Odd Lindell
Lars Eriksson
Lars-Erik Strender
Publication date
01-12-2007
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2007
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-8-31

Other articles of this Issue 1/2007

BMC Musculoskeletal Disorders 1/2007 Go to the issue