Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2011

Open Access 01-12-2011 | Research article

Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study

Authors: Ian FH Koblbauer, Yannick Lambrecht, Micheline LM van der Hulst, Camille Neeter, Raoul HH Engelbert, Rudolf W Poolman, Vanessa A Scholtes

Published in: BMC Musculoskeletal Disorders | Issue 1/2011

Login to get access

Abstract

Background

Patients undergoing total knee arthroplasty (TKA) often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable measurements should be used. This study aimed to determine the inter- and intrarater reliability of hand-held dynamometry (HHD) in measuring isometric knee strength in patients awaiting TKA.

Methods

To determine interrater reliability, 32 patients (81.3% female) were assessed by two examiners. Patients were assessed consecutively by both examiners on the same individual test dates. To determine intrarater reliability, a subgroup (n = 13) was again assessed by the examiners within four weeks of the initial testing procedure. Maximal isometric knee flexor and extensor strength were tested using a modified Citec hand-held dynamometer. Both the affected and unaffected knee were tested. Reliability was assessed using the Intraclass Correlation Coefficient (ICC). In addition, the Standard Error of Measurement (SEM) and the Smallest Detectable Difference (SDD) were used to determine reliability.

Results

In both the affected and unaffected knee, the inter- and intrarater reliability were good for knee flexors (ICC range 0.76-0.94) and excellent for knee extensors (ICC range 0.92-0.97). However, measurement error was high, displaying SDD ranges between 21.7% and 36.2% for interrater reliability and between 19.0% and 57.5% for intrarater reliability. Overall, measurement error was higher for the knee flexors than for the knee extensors.

Conclusions

Modified HHD appears to be a reliable strength measure, producing good to excellent ICC values for both inter- and intrarater reliability in a group of TKA patients. High SEM and SDD values, however, indicate high measurement error for individual measures. This study demonstrates that a modified HHD is appropriate to evaluate knee strength changes in TKA patient groups. However, it also demonstrates that modified HHD is not suitable to measure individual strength changes. The use of modified HHD is, therefore, not advised for use in a clinical setting.
Appendix
Available only for authorised users
Literature
1.
go back to reference Brooks PJ: Public health classics: Inflammation as an important feature of osteoarthritis. Bull World Health Organ. 2003, 81: 689-690.PubMedPubMedCentral Brooks PJ: Public health classics: Inflammation as an important feature of osteoarthritis. Bull World Health Organ. 2003, 81: 689-690.PubMedPubMedCentral
3.
go back to reference Poolman RW, Swiontkowski MF, Fairbank JC, Schemitsch EH, Sprague S, de Vet HC: Outcome instruments: rationale for their use. J Bone Joint Surg Am. 2009, 91 (Suppl 3): 41-49.PubMedPubMedCentral Poolman RW, Swiontkowski MF, Fairbank JC, Schemitsch EH, Sprague S, de Vet HC: Outcome instruments: rationale for their use. J Bone Joint Surg Am. 2009, 91 (Suppl 3): 41-49.PubMedPubMedCentral
4.
go back to reference Valtonen A, Poyhonen T, Heinonen A, Sipila S: Muscle deficits persist after unilateral knee replacement and have implications for rehabilitation. Phys Ther. 2009, 89: 1072-1079. 10.2522/ptj.20070295.PubMed Valtonen A, Poyhonen T, Heinonen A, Sipila S: Muscle deficits persist after unilateral knee replacement and have implications for rehabilitation. Phys Ther. 2009, 89: 1072-1079. 10.2522/ptj.20070295.PubMed
5.
go back to reference Suzuki M, Yamada S, Inamura A, Omori Y, Kirimoto H, Sugimura S, Miyamoto M: Reliability and validity of measurements of knee extension strength obtained from nursing home residents with dementia. Am J Phys Med Rehabil. 2009, 88 (11): 924-933. 10.1097/PHM.0b013e3181ae1003.PubMed Suzuki M, Yamada S, Inamura A, Omori Y, Kirimoto H, Sugimura S, Miyamoto M: Reliability and validity of measurements of knee extension strength obtained from nursing home residents with dementia. Am J Phys Med Rehabil. 2009, 88 (11): 924-933. 10.1097/PHM.0b013e3181ae1003.PubMed
6.
go back to reference Gagnon D, Nadeau S, Gravel D, Robert J, Belanger D, Hilsenrath M: Reliability and validity of static knee strength measurements obtained with a chair-fixed dynamometer in subjects with hip or knee arthroplasty. Arch Phys Med Rehabil. 2005, 86: 1998-2008. 10.1016/j.apmr.2005.04.013.PubMed Gagnon D, Nadeau S, Gravel D, Robert J, Belanger D, Hilsenrath M: Reliability and validity of static knee strength measurements obtained with a chair-fixed dynamometer in subjects with hip or knee arthroplasty. Arch Phys Med Rehabil. 2005, 86: 1998-2008. 10.1016/j.apmr.2005.04.013.PubMed
7.
go back to reference Wessel J, Kaup C, Fan J, Ehalt R, Ellsworth J, Speer C, Tenove P, Dombrosky A: Isometric strength measurements in children with arthritis: reliability and relation to function. Arthritis Care Res. 1999, 12: 238-246. 10.1002/1529-0131(199908)12:4<238::AID-ART2>3.0.CO;2-I.PubMed Wessel J, Kaup C, Fan J, Ehalt R, Ellsworth J, Speer C, Tenove P, Dombrosky A: Isometric strength measurements in children with arthritis: reliability and relation to function. Arthritis Care Res. 1999, 12: 238-246. 10.1002/1529-0131(199908)12:4<238::AID-ART2>3.0.CO;2-I.PubMed
8.
go back to reference McAlindon TE, Cooper C, Kirwan JR, Dieppe PA: Determinants of disability in osteoarthritis of the knee. Ann Rheum Dis. 1993, 52: 258-262. 10.1136/ard.52.4.258.PubMedPubMedCentral McAlindon TE, Cooper C, Kirwan JR, Dieppe PA: Determinants of disability in osteoarthritis of the knee. Ann Rheum Dis. 1993, 52: 258-262. 10.1136/ard.52.4.258.PubMedPubMedCentral
9.
go back to reference Dreinhöfer K, Stucki G, Ewert T, Ebenbichler G, Gutenbrunner C, Kostanjsek N, Cieza A: ICF Core Sets for osteoarthritis. J Rehabil Med. 2004, 44 (Suppl): 75-80.PubMed Dreinhöfer K, Stucki G, Ewert T, Ebenbichler G, Gutenbrunner C, Kostanjsek N, Cieza A: ICF Core Sets for osteoarthritis. J Rehabil Med. 2004, 44 (Suppl): 75-80.PubMed
10.
go back to reference Maffiuletti NA: Assessment of hip and knee muscle function in orthopaedic practice and research. J Bone Joint Surg Am. 2010, 92: 220-229. 10.2106/JBJS.I.00305.PubMed Maffiuletti NA: Assessment of hip and knee muscle function in orthopaedic practice and research. J Bone Joint Surg Am. 2010, 92: 220-229. 10.2106/JBJS.I.00305.PubMed
11.
go back to reference Bohannon RW: Quantitative testing of muscle strength: Issues and practical options for the geriatric population. Top Geriatr Rehabil. 2002, 17-35. Bohannon RW: Quantitative testing of muscle strength: Issues and practical options for the geriatric population. Top Geriatr Rehabil. 2002, 17-35.
12.
go back to reference Hartmann A, Knols R, Murer K, de Bruin ED: Reproducibility of an isokinetic strength-testing protocol of the knee and ankle in older adults. Gerontology. 2009, 55: 259-268. 10.1159/000172832.PubMed Hartmann A, Knols R, Murer K, de Bruin ED: Reproducibility of an isokinetic strength-testing protocol of the knee and ankle in older adults. Gerontology. 2009, 55: 259-268. 10.1159/000172832.PubMed
13.
go back to reference Neeter C, Gustavsson A, Thomee P, Augustsson J, Thomee R, Karlsson J: Development of a strength test battery for evaluating leg muscle power after anterior cruciate ligament injury and reconstruction. Knee Surg Sports Traumatol Arthrosc. 2006, 14: 571-580. 10.1007/s00167-006-0040-y.PubMed Neeter C, Gustavsson A, Thomee P, Augustsson J, Thomee R, Karlsson J: Development of a strength test battery for evaluating leg muscle power after anterior cruciate ligament injury and reconstruction. Knee Surg Sports Traumatol Arthrosc. 2006, 14: 571-580. 10.1007/s00167-006-0040-y.PubMed
14.
go back to reference Knols RH, Aufdemkampe G, de Bruin ED, Uebelhart D, Aaronson NK: Hand-held dynamometry in patients with haematological malignancies: measurement error in the clinical assessment of knee extension strength. BMC Musculoskelet Disord. 2009, 10: 31-10.1186/1471-2474-10-31.PubMedPubMedCentral Knols RH, Aufdemkampe G, de Bruin ED, Uebelhart D, Aaronson NK: Hand-held dynamometry in patients with haematological malignancies: measurement error in the clinical assessment of knee extension strength. BMC Musculoskelet Disord. 2009, 10: 31-10.1186/1471-2474-10-31.PubMedPubMedCentral
15.
go back to reference Katz-Leurer M, Rottem H, Meyer S: Hand-held dynamometry in children with traumatic brain injury: within-session reliability. Pediatr Phys Ther. 2008, 20: 259-263. 10.1097/PEP.0b013e3181824782.PubMed Katz-Leurer M, Rottem H, Meyer S: Hand-held dynamometry in children with traumatic brain injury: within-session reliability. Pediatr Phys Ther. 2008, 20: 259-263. 10.1097/PEP.0b013e3181824782.PubMed
16.
go back to reference Mercer VS, Lewis CL: Hip Abductor and Knee Extensor Muscle Strength of Children with and without Down Syndrome. Pediatr Phys Ther. 2001, 13: 18-26. 10.1097/00001577-200104000-00004.PubMed Mercer VS, Lewis CL: Hip Abductor and Knee Extensor Muscle Strength of Children with and without Down Syndrome. Pediatr Phys Ther. 2001, 13: 18-26. 10.1097/00001577-200104000-00004.PubMed
17.
go back to reference Martin HJ, Yule V, Syddall HE, Dennison EM, Cooper C, Aihie SA: Is hand-held dynamometry useful for the measurement of quadriceps strength in older people? A comparison with the gold standard Bodex dynamometry. Gerontology. 2006, 52: 154-159. 10.1159/000091824.PubMed Martin HJ, Yule V, Syddall HE, Dennison EM, Cooper C, Aihie SA: Is hand-held dynamometry useful for the measurement of quadriceps strength in older people? A comparison with the gold standard Bodex dynamometry. Gerontology. 2006, 52: 154-159. 10.1159/000091824.PubMed
18.
go back to reference O'Shea SD, Taylor NF, Paratz JD: Measuring muscle strength for people with chronic obstructive pulmonary disease: retest reliability of hand-held dynamometry. Arch Phys Med Rehabil. 2007, 88: 32-36. 10.1016/j.apmr.2006.10.002.PubMed O'Shea SD, Taylor NF, Paratz JD: Measuring muscle strength for people with chronic obstructive pulmonary disease: retest reliability of hand-held dynamometry. Arch Phys Med Rehabil. 2007, 88: 32-36. 10.1016/j.apmr.2006.10.002.PubMed
19.
go back to reference Kwoh CK, Petrick MA, Munin MC: Inter-rater reliability for function and strength measurements in the acute care hospital after elective hip and knee arthroplasty. Arthr Care Res. 1997, 10: 128-134. 10.1002/art.1790100208. Kwoh CK, Petrick MA, Munin MC: Inter-rater reliability for function and strength measurements in the acute care hospital after elective hip and knee arthroplasty. Arthr Care Res. 1997, 10: 128-134. 10.1002/art.1790100208.
20.
go back to reference Hayes KW, Falconer J: Reliability of hand-held dynamometry and its relationship with manual muscle testing in patients with osteoarthritis in the knee. J Orthop Sports Phys Ther. 2010, 3: 145-149. Hayes KW, Falconer J: Reliability of hand-held dynamometry and its relationship with manual muscle testing in patients with osteoarthritis in the knee. J Orthop Sports Phys Ther. 2010, 3: 145-149.
21.
go back to reference Arokoski MH, Arokoski JP, Haara M, Haara M, Kankaanpää M, Vesterinen M, Niemitukia KH, Helminen HJ: Hip muscle strength and muscle cross sectional area in men with and without hip osteoarthritis. J Rheumatol. 2002, 29: 2185-2195.PubMed Arokoski MH, Arokoski JP, Haara M, Haara M, Kankaanpää M, Vesterinen M, Niemitukia KH, Helminen HJ: Hip muscle strength and muscle cross sectional area in men with and without hip osteoarthritis. J Rheumatol. 2002, 29: 2185-2195.PubMed
22.
go back to reference Fransen M, Crosbie J, Edmonds J: Isometric muscle force measurement for clinicians treating patients with osteoarthritis of the knee. Arthritis Rheum. 2003, 49: 29-35. 10.1002/art.10923.PubMed Fransen M, Crosbie J, Edmonds J: Isometric muscle force measurement for clinicians treating patients with osteoarthritis of the knee. Arthritis Rheum. 2003, 49: 29-35. 10.1002/art.10923.PubMed
23.
go back to reference McCarthy C, Callaghan M, Oldham J: The reliability of isometric strength and fatigue measures in patients with knee osteoarthritis. Man Ther. 2008, 13: 159-64. 10.1016/j.math.2006.12.003.PubMed McCarthy C, Callaghan M, Oldham J: The reliability of isometric strength and fatigue measures in patients with knee osteoarthritis. Man Ther. 2008, 13: 159-64. 10.1016/j.math.2006.12.003.PubMed
24.
go back to reference Berry ET, Giuliani CA, Damiano DL: Intrasession and intersession reliability of handheld dynamometry in children with cerebral palsy. Pediatr Phys Ther. 2004, 16: 191-198. 10.1097/01.PEP.0000145932.21460.61.PubMed Berry ET, Giuliani CA, Damiano DL: Intrasession and intersession reliability of handheld dynamometry in children with cerebral palsy. Pediatr Phys Ther. 2004, 16: 191-198. 10.1097/01.PEP.0000145932.21460.61.PubMed
25.
go back to reference Roebroek ME, Harlaar J, Lankhorst GJ: The application of generalizability theory to reliability assessment: an illustration using isometric force measurements. Phys Ther. 1993, 73: 386-395. Roebroek ME, Harlaar J, Lankhorst GJ: The application of generalizability theory to reliability assessment: an illustration using isometric force measurements. Phys Ther. 1993, 73: 386-395.
26.
go back to reference Bohannon RW: The clinical measurement of strength. Clin Rehabil. 1987, 1: 05-16. 10.1177/026921558700100103. Bohannon RW: The clinical measurement of strength. Clin Rehabil. 1987, 1: 05-16. 10.1177/026921558700100103.
27.
go back to reference Burns SP, Spanier DE: Break-technique handheld dynamometry: relation between angular velocity and strength measurements. Arch Phys Med Rehabil. 2005, 86: 1420-1426. 10.1016/j.apmr.2004.12.041.PubMed Burns SP, Spanier DE: Break-technique handheld dynamometry: relation between angular velocity and strength measurements. Arch Phys Med Rehabil. 2005, 86: 1420-1426. 10.1016/j.apmr.2004.12.041.PubMed
28.
go back to reference Crompton J, Galea MP, Phillips B: Hand-held dynamometry for muscle strength measurement in children with cerebral palsy. Dev Med Child Neurol. 2007, 49: 106-111. 10.1111/j.1469-8749.2007.00106.x.PubMed Crompton J, Galea MP, Phillips B: Hand-held dynamometry for muscle strength measurement in children with cerebral palsy. Dev Med Child Neurol. 2007, 49: 106-111. 10.1111/j.1469-8749.2007.00106.x.PubMed
29.
go back to reference Carpenter MR, Carpenter RL, Peel J, Zukley LM, Angelopoulou KM, Fischer I, Angelopoulos TJ, Rippe JM: The reliability of isokinetic and isometric leg strength measures among individuals with symptoms of mild osteoarthritis. J Sports Med Phys Fitness. 2006, 46: 585-589.PubMed Carpenter MR, Carpenter RL, Peel J, Zukley LM, Angelopoulou KM, Fischer I, Angelopoulos TJ, Rippe JM: The reliability of isokinetic and isometric leg strength measures among individuals with symptoms of mild osteoarthritis. J Sports Med Phys Fitness. 2006, 46: 585-589.PubMed
30.
go back to reference de Salles BF, Simao R, Miranda F, Novaes JS, Lemos A, Willardson JM: Rest interval between sets in strength training. Sports Med. 2009, 39: 765-777. 10.2165/11315230-000000000-00000.PubMed de Salles BF, Simao R, Miranda F, Novaes JS, Lemos A, Willardson JM: Rest interval between sets in strength training. Sports Med. 2009, 39: 765-777. 10.2165/11315230-000000000-00000.PubMed
31.
go back to reference Lu TW, Hsu HC, Chang LY, Chen HL: Enhancing the examiner's resisting force improves the reliability of manual muscle strength measurements: comparison of a new device with hand-held dynamometry. J Rehabil Med. 2007, 39: 679-684. 10.2340/16501977-0107.PubMed Lu TW, Hsu HC, Chang LY, Chen HL: Enhancing the examiner's resisting force improves the reliability of manual muscle strength measurements: comparison of a new device with hand-held dynamometry. J Rehabil Med. 2007, 39: 679-684. 10.2340/16501977-0107.PubMed
32.
go back to reference Portney LG, Watkins MP: Foundations of clinical research. Applications to practice. 2000, Upper Saddle River: Prentice-Hall, 2 Portney LG, Watkins MP: Foundations of clinical research. Applications to practice. 2000, Upper Saddle River: Prentice-Hall, 2
33.
go back to reference Cibere J, Thorne A, Bellamy N, Greidanus N, Chalmers A, Mahomed N, Shojania K, Kopec J, Esdaile JM: Reliability of the hip examination in osteoarthritis: effect of standardization. Arthritis Rheum. 2008, 59: 373-381. 10.1002/art.23310.PubMed Cibere J, Thorne A, Bellamy N, Greidanus N, Chalmers A, Mahomed N, Shojania K, Kopec J, Esdaile JM: Reliability of the hip examination in osteoarthritis: effect of standardization. Arthritis Rheum. 2008, 59: 373-381. 10.1002/art.23310.PubMed
34.
go back to reference Roy MA, Doherty TJ: Reliability of hand-held dynamometry in assessment of knee extensor strength after hip fracture. Am J Phys Med Rehabil. 2004, 83: 813-818. 10.1097/01.PHM.0000143405.17932.78.PubMed Roy MA, Doherty TJ: Reliability of hand-held dynamometry in assessment of knee extensor strength after hip fracture. Am J Phys Med Rehabil. 2004, 83: 813-818. 10.1097/01.PHM.0000143405.17932.78.PubMed
35.
go back to reference Mizner RL, Petterson SC, Stevens JE, Vandenborne K, Snyder-Mackler L: Early quadriceps strength loss after total knee arthroplasty. The contributions of muscle atrophy and failure of voluntary muscle activation. J Bone Joint Surg Am. 2005, 87: 1047-1053. 10.2106/JBJS.D.01992.PubMedPubMedCentral Mizner RL, Petterson SC, Stevens JE, Vandenborne K, Snyder-Mackler L: Early quadriceps strength loss after total knee arthroplasty. The contributions of muscle atrophy and failure of voluntary muscle activation. J Bone Joint Surg Am. 2005, 87: 1047-1053. 10.2106/JBJS.D.01992.PubMedPubMedCentral
36.
go back to reference Stevens JE, Mizner RL, Snyder-Mackler L: Quadriceps strength and volitional activation before and after total knee arthroplasty for osteoarthritis. J Orthop Res. 2003, 21: 775-779. 10.1016/S0736-0266(03)00052-4.PubMed Stevens JE, Mizner RL, Snyder-Mackler L: Quadriceps strength and volitional activation before and after total knee arthroplasty for osteoarthritis. J Orthop Res. 2003, 21: 775-779. 10.1016/S0736-0266(03)00052-4.PubMed
37.
go back to reference Yoshida Y, Mizner RL, Ramsey DK, Snyder-Mackler L: Examining outcomes from total knee arthroplasty and the relationship between quadriceps strength and knee function over time. Clin Biomech (Bristol, Avon). 2008, 23: 320-328. 10.1016/j.clinbiomech.2007.10.008. Yoshida Y, Mizner RL, Ramsey DK, Snyder-Mackler L: Examining outcomes from total knee arthroplasty and the relationship between quadriceps strength and knee function over time. Clin Biomech (Bristol, Avon). 2008, 23: 320-328. 10.1016/j.clinbiomech.2007.10.008.
38.
go back to reference Lorentzen JS, Petersen MM, Brot C, Madsen OR: Early changes in muscle strength after total knee arthroplasty. A 6-month follow-up of 30 knees. Acta Orthop Scand. 1999, 70: 176-179. 10.3109/17453679909011258.PubMed Lorentzen JS, Petersen MM, Brot C, Madsen OR: Early changes in muscle strength after total knee arthroplasty. A 6-month follow-up of 30 knees. Acta Orthop Scand. 1999, 70: 176-179. 10.3109/17453679909011258.PubMed
39.
go back to reference Johansson AC, Cornefjord M, Bergkvist L, Ohrvik J, Linton SJ: Psychosocial stress factors among patients with lumbar disc herniation, scheduled for disc surgery in comparison with patients scheduled for arthroscopic knee surgery. Eur Spine J. 2007, 16: 961-970. 10.1007/s00586-007-0319-9.PubMedPubMedCentral Johansson AC, Cornefjord M, Bergkvist L, Ohrvik J, Linton SJ: Psychosocial stress factors among patients with lumbar disc herniation, scheduled for disc surgery in comparison with patients scheduled for arthroscopic knee surgery. Eur Spine J. 2007, 16: 961-970. 10.1007/s00586-007-0319-9.PubMedPubMedCentral
Metadata
Title
Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study
Authors
Ian FH Koblbauer
Yannick Lambrecht
Micheline LM van der Hulst
Camille Neeter
Raoul HH Engelbert
Rudolf W Poolman
Vanessa A Scholtes
Publication date
01-12-2011
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2011
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-12-249

Other articles of this Issue 1/2011

BMC Musculoskeletal Disorders 1/2011 Go to the issue