Skip to main content
Top
Published in: BMC Medical Imaging 1/2011

Open Access 01-12-2011 | Research article

Non-opaque soft tissue foreign body: sonographic findings

Authors: Afshin Mohammadi, Mohammad Ghasemi-Rad, Maryam Khodabakhsh

Published in: BMC Medical Imaging | Issue 1/2011

Login to get access

Abstract

Background

Soft tissue foreign bodies are a common cause of orthopedic consultation in emergency departments. It is difficult to confirm their existence because conventional radiology only detects radio-opaque foreign bodies. Sonography can be a useful diagnostic method. The aim of this study is to evaluate diagnostic accuracy of sonography in detection and localization of non-opaque foreign bodies.

Methods

We evaluated 47 patients with suspected foreign body retention in soft tissues by 10 MHz linear array transducer. A single radiologist performed all examinations with 6 years' experience in musculoskeletal Sonography. We detected and localized the presence of the foreign body in the soft tissue as guidance for facilitating the surgery.

Results

We detected soft tissue foreign body in 45 cases as hyperechoic foci. Posterior acoustic shadowing was seen in 36 cases and halo sign was seen in 5 cases due to abscess or granulation tissue formation. Surgery was performed in 39 patients and 44 foreign bodies were removed.

Conclusion

Sonography is a useful modality in detection and localization of radiolucent foreign bodies in soft tissue which can avoid misdiagnosis during primary emergency evaluation.
Appendix
Available only for authorised users
Literature
1.
go back to reference Mohamadi A, Kodabakhsh M: Wooden foreign body in lung parenchyma, a case report. Turkish Journal of trauma and emergency surgery. 2010, 16 (5): 480-482.PubMed Mohamadi A, Kodabakhsh M: Wooden foreign body in lung parenchyma, a case report. Turkish Journal of trauma and emergency surgery. 2010, 16 (5): 480-482.PubMed
2.
go back to reference Flom LL, Ellis GL: Radiologic evaluation of foreign bodies. Emerg Med Clin North Am. 1992, 10: 163-176.PubMed Flom LL, Ellis GL: Radiologic evaluation of foreign bodies. Emerg Med Clin North Am. 1992, 10: 163-176.PubMed
3.
go back to reference Graham DD: Ultrasound in the emergency department: detection of wooden foreign bodies in the soft tissues. J Emerg Med. 2002, 22 (1): 75-9. 10.1016/S0736-4679(01)00440-1.CrossRefPubMed Graham DD: Ultrasound in the emergency department: detection of wooden foreign bodies in the soft tissues. J Emerg Med. 2002, 22 (1): 75-9. 10.1016/S0736-4679(01)00440-1.CrossRefPubMed
4.
go back to reference Anderson MA, Newmeyer WL, Kilgore ES: Diagnosis and treatment of retained foreign bodies in the hand. Am J Surg. 1982, 144: 63-67. 10.1016/0002-9610(82)90603-1.CrossRefPubMed Anderson MA, Newmeyer WL, Kilgore ES: Diagnosis and treatment of retained foreign bodies in the hand. Am J Surg. 1982, 144: 63-67. 10.1016/0002-9610(82)90603-1.CrossRefPubMed
5.
go back to reference Peterson JJ, Bancroft LW, Kransdorf MJ: Wooden foreign bodies: imaging appearance. AJR Am J Roentgenol. 2002, 178 (3): 557-62.CrossRefPubMed Peterson JJ, Bancroft LW, Kransdorf MJ: Wooden foreign bodies: imaging appearance. AJR Am J Roentgenol. 2002, 178 (3): 557-62.CrossRefPubMed
6.
go back to reference Crowford R, Matheson AB: Clinical value of ultrasonography in detection and removal of radiolucent foreign bodies. Injury. 1989, 20: 341-343. 10.1016/0020-1383(89)90008-9.CrossRef Crowford R, Matheson AB: Clinical value of ultrasonography in detection and removal of radiolucent foreign bodies. Injury. 1989, 20: 341-343. 10.1016/0020-1383(89)90008-9.CrossRef
7.
go back to reference Ober CP, Jones JC, Larson MM, Lanz OI, Werre SR: Comparison of ultrasound, computed tomography, and magnetic resonance imaging in detection of acute wooden foreign bodies in the canine manus. Vet Radiol Ultrasound. 2008, 49 (5): 411-8. 10.1111/j.1740-8261.2008.00399.x.CrossRefPubMed Ober CP, Jones JC, Larson MM, Lanz OI, Werre SR: Comparison of ultrasound, computed tomography, and magnetic resonance imaging in detection of acute wooden foreign bodies in the canine manus. Vet Radiol Ultrasound. 2008, 49 (5): 411-8. 10.1111/j.1740-8261.2008.00399.x.CrossRefPubMed
8.
go back to reference Venter NG, Jamel N, Marques RG, Djahjah F, Mendonça Lde S: Evaluation of radiological methods for detection of wood foreign body in animal model. Acta Cir Bras. 2005, 20 (Suppl 1): 34-41.PubMed Venter NG, Jamel N, Marques RG, Djahjah F, Mendonça Lde S: Evaluation of radiological methods for detection of wood foreign body in animal model. Acta Cir Bras. 2005, 20 (Suppl 1): 34-41.PubMed
9.
go back to reference Little CM, Parker MG, Callowich MC, Sartori JC: The ultrasonic detection soft tissue foreign bodies. Invest Radiol. 1986, 21: 275-7. 10.1097/00004424-198603000-00014.CrossRefPubMed Little CM, Parker MG, Callowich MC, Sartori JC: The ultrasonic detection soft tissue foreign bodies. Invest Radiol. 1986, 21: 275-7. 10.1097/00004424-198603000-00014.CrossRefPubMed
10.
go back to reference Walter JP: Physics of high resolution -practical aspect. Radiol Clin North Am. 1985, 23: 3-11.PubMed Walter JP: Physics of high resolution -practical aspect. Radiol Clin North Am. 1985, 23: 3-11.PubMed
11.
go back to reference Donaldson J: Radiographic imaging of foreign bodies in the hand. Hand Clin. 1991, 7: 125-134.PubMed Donaldson J: Radiographic imaging of foreign bodies in the hand. Hand Clin. 1991, 7: 125-134.PubMed
12.
go back to reference Conti RJ, Shinder M: Soft tissue calcification induced by local corticosteroid injection. J Foot Surg. 1991, 30: 34-7.PubMed Conti RJ, Shinder M: Soft tissue calcification induced by local corticosteroid injection. J Foot Surg. 1991, 30: 34-7.PubMed
13.
go back to reference Gilbert FJ, Campbel RSD, Bayliss AP: The role of ultrasound in detection of non- opaque foreign bodies. Clin Radiol. 1990, 40: 109-112. 10.1016/S0009-9260(05)80140-0.CrossRef Gilbert FJ, Campbel RSD, Bayliss AP: The role of ultrasound in detection of non- opaque foreign bodies. Clin Radiol. 1990, 40: 109-112. 10.1016/S0009-9260(05)80140-0.CrossRef
14.
go back to reference Fornage BD, Schernberg FL: Sonographic diagnosis of foreign bodies of the distal extremities. AJR. 1986, 147: 567-569.CrossRefPubMed Fornage BD, Schernberg FL: Sonographic diagnosis of foreign bodies of the distal extremities. AJR. 1986, 147: 567-569.CrossRefPubMed
15.
go back to reference Jacobson JA, Powell A, Craig JG, Bouffard JA, van Holsbeeck MT: Wooden foreign bodies in soft tissue: detection at US. Radiology. 1998, 206 (1): 45-8.CrossRefPubMed Jacobson JA, Powell A, Craig JG, Bouffard JA, van Holsbeeck MT: Wooden foreign bodies in soft tissue: detection at US. Radiology. 1998, 206 (1): 45-8.CrossRefPubMed
16.
go back to reference Dumarey A, De Maeseneer M, Ernst C: Large wooden foreign body in the hand: recognition of occult fragments with ultrasound. Emerg Radiol. 2004, 10 (6): 337-9.CrossRefPubMed Dumarey A, De Maeseneer M, Ernst C: Large wooden foreign body in the hand: recognition of occult fragments with ultrasound. Emerg Radiol. 2004, 10 (6): 337-9.CrossRefPubMed
Metadata
Title
Non-opaque soft tissue foreign body: sonographic findings
Authors
Afshin Mohammadi
Mohammad Ghasemi-Rad
Maryam Khodabakhsh
Publication date
01-12-2011
Publisher
BioMed Central
Published in
BMC Medical Imaging / Issue 1/2011
Electronic ISSN: 1471-2342
DOI
https://doi.org/10.1186/1471-2342-11-9

Other articles of this Issue 1/2011

BMC Medical Imaging 1/2011 Go to the issue