Skip to main content
Top
Published in: Lasers in Dental Science 3/2018

01-09-2018 | Original Article

Corrosion behavior of erbium chromium-doped yattrium-scandium-gallium-garnet (Er,Cr:YSGG 2780 nm) laser-treated titanium alloy used for dental applications at different pH conditions (in vitro study)

Authors: Dalia A. Abd El daym, Mostafa E. Gheith, Nadia A. Abbas, Laila A. Rashed, Zeinab A. Abd El Aziz

Published in: Lasers in Dental Science | Issue 3/2018

Login to get access

Abstract

Titanium alloys are most often used in the design of dental implants. Although these biomaterials have good mechanical and biological properties, their corrosion resistance is still critical for the overall success of the treatment procedure. Implant failure is more likely to occur in inflammatory diseases related to low pH levels. Er,Cr:YSGG laser is most often used in implant dentistry.
The aim of the this study was to assess the effect of Er,Cr:YSGG laser surface treatment on the corrosion behavior of titanium alloy (Ti–6Al–4V) at different pH.

Materials and methods

A total of 40 discs were used. Twenty discs were irradiated with Er,Cr:YSGG laser, which was operating in a normal room atmosphere and temperature at power 2 W. The corrosion behavior was investigated in simulated body fluid at pH of 7.40 and 5.20. At each pH, corrosion behavior was studied for up to 864 h at 192, 360, 696, and 864 h intervals using potentiodynamic polarization test and electrochemical impedance spectroscopy. The laser-treated and -untreated discs were examined with scanning electron microscope before and after the electrochemical tests.

Result

Laser treatment significantly improves the corrosion resistance compared to the untreated group. Immersion time and pH also significantly affect the corrosion behavior. The acidity yielded more aggressive changes on the untreated titanium alloy.

Conclusion

Er,Cr:YSGG laser could improve the corrosion resistance of Ti–6Al–4V.
Literature
1.
go back to reference Piotrowski B, Baptista AA, Patoor E, Bravetti P, Eberhardt A, Laheurte P (2014) Interaction of bone–dental implant with new ultra low modulus alloy using a numerical approach. Mater Sci and Engin C 38:151–160CrossRef Piotrowski B, Baptista AA, Patoor E, Bravetti P, Eberhardt A, Laheurte P (2014) Interaction of bone–dental implant with new ultra low modulus alloy using a numerical approach. Mater Sci and Engin C 38:151–160CrossRef
2.
go back to reference Triplett RG, Frohberg U, Sykaras N, Woody RD (2003) Implant materials, design and surface topographies: their influence on osseointegration of dental implants. J Long-Term Eff Med Implants 13:485–501CrossRefPubMed Triplett RG, Frohberg U, Sykaras N, Woody RD (2003) Implant materials, design and surface topographies: their influence on osseointegration of dental implants. J Long-Term Eff Med Implants 13:485–501CrossRefPubMed
3.
go back to reference Mathew MT, Abbey S, Hallab NJ, Hall DJ, Sukotjo C, Wimmer MA (2012) Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: synergistic interactions of wear and corrosion. J Biomed Mater Res B Appl Biomater 100:1662–1671CrossRefPubMed Mathew MT, Abbey S, Hallab NJ, Hall DJ, Sukotjo C, Wimmer MA (2012) Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: synergistic interactions of wear and corrosion. J Biomed Mater Res B Appl Biomater 100:1662–1671CrossRefPubMed
4.
go back to reference Geetha M, Durgalakshmi D, Asokamani R (2010) Biomedical implants: corrosion and its prevention—a review. Recent Patents Corros Sci 2:40–54CrossRef Geetha M, Durgalakshmi D, Asokamani R (2010) Biomedical implants: corrosion and its prevention—a review. Recent Patents Corros Sci 2:40–54CrossRef
5.
go back to reference Gimbel CB: (2000) Hard tissue laser procedures. In: Convissar FA, Dent Clin North Am. Philadelphia, PA: Saunders 44:931–948 Gimbel CB: (2000) Hard tissue laser procedures. In: Convissar FA, Dent Clin North Am. Philadelphia, PA: Saunders 44:931–948
6.
go back to reference Featherstone, JD: (2000) Caries detection and prevention with laser energy. In: Convissar FA, Dent Clin North Am. Philadelphia, PA; Saunders 44:955–966 Featherstone, JD: (2000) Caries detection and prevention with laser energy. In: Convissar FA, Dent Clin North Am. Philadelphia, PA; Saunders 44:955–966
7.
go back to reference Romanos GE, Gupta B, Yunker M et al (2013) Lasers use in dental implantology. Implant Dent 22:282–288CrossRefPubMed Romanos GE, Gupta B, Yunker M et al (2013) Lasers use in dental implantology. Implant Dent 22:282–288CrossRefPubMed
8.
go back to reference Matsumoto K, Hossain MM, Kawano H, Kimura Y (2002) Clinical assessment of Er ,Cr: YSGG laser application for cavity preparation. J Clin Laser Med Surg 20:17–21CrossRefPubMed Matsumoto K, Hossain MM, Kawano H, Kimura Y (2002) Clinical assessment of Er ,Cr: YSGG laser application for cavity preparation. J Clin Laser Med Surg 20:17–21CrossRefPubMed
9.
go back to reference Arisan V, Karabuda CZ, Ozdemir T (2010) Implant surgery using bone- and mucosa-supported stereolithographic guides in totally edentulous jaws: surgical and post-operative outcomes of computer-aided vs. standard techniques. Clin Oral Implants Res 21(9):980–988PubMed Arisan V, Karabuda CZ, Ozdemir T (2010) Implant surgery using bone- and mucosa-supported stereolithographic guides in totally edentulous jaws: surgical and post-operative outcomes of computer-aided vs. standard techniques. Clin Oral Implants Res 21(9):980–988PubMed
10.
go back to reference Nickenig H-J, Wichmann M, Schlegel KA, Nkenke E, Eitner S (2010) Radiographic evaluation of marginal bone levels during healing period, adjacent to parallel-screw cylinder implants inserted in the posterior zone of the jaws, placed with flapless surgery. Clin Oral Implants Res 21(12):1386–1393CrossRefPubMed Nickenig H-J, Wichmann M, Schlegel KA, Nkenke E, Eitner S (2010) Radiographic evaluation of marginal bone levels during healing period, adjacent to parallel-screw cylinder implants inserted in the posterior zone of the jaws, placed with flapless surgery. Clin Oral Implants Res 21(12):1386–1393CrossRefPubMed
11.
go back to reference Gomez-Santos L, Arnabat-Dominguez J, Sierra-Rebolledo A, Gay-Escoda C (2010) Thermal increment due to Er,Cr:YSGG and CO2 laser irradiation of different implant surfaces. Apilot study. Med Oral Patol Oral Cir Bucal 15:782–787CrossRef Gomez-Santos L, Arnabat-Dominguez J, Sierra-Rebolledo A, Gay-Escoda C (2010) Thermal increment due to Er,Cr:YSGG and CO2 laser irradiation of different implant surfaces. Apilot study. Med Oral Patol Oral Cir Bucal 15:782–787CrossRef
12.
go back to reference Hansen DC (2008) Metal corrosion in the human body: the ultimate bio-corrosion scenario. Electrochem Soc Interface 17:24–27 Hansen DC (2008) Metal corrosion in the human body: the ultimate bio-corrosion scenario. Electrochem Soc Interface 17:24–27
13.
go back to reference Sato N. (2012) Basics of corrosion chemistry.Green corrosion chemistry and engineering 1st edition Sato N. (2012) Basics of corrosion chemistry.Green corrosion chemistry and engineering 1st edition
14.
go back to reference Schmutz P, Quach-Vu N, Gerber I (2008) Metallic medical implants: electrochemical characterization of corrosion processes. Electrochem Soc Interface 17:35–40 Schmutz P, Quach-Vu N, Gerber I (2008) Metallic medical implants: electrochemical characterization of corrosion processes. Electrochem Soc Interface 17:35–40
15.
go back to reference Al-Mobarak NA, Al-Swayih AA, Al-Rashod FA (2011) Corrosion behavior of Ti-6Al-7Nb alloy in biological solution for dentistry applications. Int J Electrochem Sci 6:2031–2042 Al-Mobarak NA, Al-Swayih AA, Al-Rashod FA (2011) Corrosion behavior of Ti-6Al-7Nb alloy in biological solution for dentistry applications. Int J Electrochem Sci 6:2031–2042
16.
go back to reference Lee JH, Heo SJ, Koak JY, Kim SK, Lee SJ, Lee SH (2008) Cellular responses on anodized titanium discs after laser irradiation. Lasers Surg Med 40:738–742CrossRefPubMed Lee JH, Heo SJ, Koak JY, Kim SK, Lee SJ, Lee SH (2008) Cellular responses on anodized titanium discs after laser irradiation. Lasers Surg Med 40:738–742CrossRefPubMed
17.
go back to reference Neupane MP, Park IS, Lee MH (2014) Surface characterization and corrosion behavior of micro-arc oxidized Ti surface modified with hydrothermal treatment and chitosan coating. Thin Solid Films 550:268–271CrossRef Neupane MP, Park IS, Lee MH (2014) Surface characterization and corrosion behavior of micro-arc oxidized Ti surface modified with hydrothermal treatment and chitosan coating. Thin Solid Films 550:268–271CrossRef
18.
go back to reference Jiang Z, Dai X, Norby T, Middleton H (2011) Investigation of pitting resistance of titanium based on a modified point defect model. Corros Sci 53:815–821CrossRef Jiang Z, Dai X, Norby T, Middleton H (2011) Investigation of pitting resistance of titanium based on a modified point defect model. Corros Sci 53:815–821CrossRef
19.
go back to reference Antunes RA, De Oliveira MCL, Costa I (2012) Study of the correlation between corrosion resistance and semi-conducting properties of the passive film of AISI 316 L stainless steel in physiological solution. Mater Corros 63:586–592 Antunes RA, De Oliveira MCL, Costa I (2012) Study of the correlation between corrosion resistance and semi-conducting properties of the passive film of AISI 316 L stainless steel in physiological solution. Mater Corros 63:586–592
20.
go back to reference Robin A, Carvalho OAS, Schneider SG, Schneider S. (2008) Corrosion behavior of Ti-xNb-13-Zr alloys in Ringer’s solution, Mater Corrosion 59: 929–933 Robin A, Carvalho OAS, Schneider SG, Schneider S. (2008) Corrosion behavior of Ti-xNb-13-Zr alloys in Ringer’s solution, Mater Corrosion 59: 929–933
21.
go back to reference Guo HX, Lu BT, Luo JL (2006) Non-Faraday material loss in flowing corrosive solution. Electrochim Acta 51:5341–5348CrossRef Guo HX, Lu BT, Luo JL (2006) Non-Faraday material loss in flowing corrosive solution. Electrochim Acta 51:5341–5348CrossRef
22.
go back to reference Munirathinam B, Neelakantan L (2015) Titania nanotubes from weak organic acid electrolyte: fabrication, characterization and oxide film properties. Mater Sci Eng C 49:567–578CrossRef Munirathinam B, Neelakantan L (2015) Titania nanotubes from weak organic acid electrolyte: fabrication, characterization and oxide film properties. Mater Sci Eng C 49:567–578CrossRef
23.
go back to reference Park JH, Heo SJ, Koak JY, Kim SK, Han CH, Lee JH (2012) Effects of laser irradiation on machined and anodized titanium disks. Int J Oral Maxillofac Implants 27:265–272PubMed Park JH, Heo SJ, Koak JY, Kim SK, Han CH, Lee JH (2012) Effects of laser irradiation on machined and anodized titanium disks. Int J Oral Maxillofac Implants 27:265–272PubMed
24.
go back to reference Miller RJ (2004) Treatment of the contaminated implant surface using Er,Cr:YSGG laser. Implant Dent 13:165–170CrossRefPubMed Miller RJ (2004) Treatment of the contaminated implant surface using Er,Cr:YSGG laser. Implant Dent 13:165–170CrossRefPubMed
25.
go back to reference Li Y, Zhang T, Wang F (2006) Effect of microcrystallization on corrosion resistance of AZ91D alloy. Electrochim Acta 51:2845–2850CrossRef Li Y, Zhang T, Wang F (2006) Effect of microcrystallization on corrosion resistance of AZ91D alloy. Electrochim Acta 51:2845–2850CrossRef
26.
go back to reference Singh R, Kurella A, Dahotre NB (2006) Laser surface modification of Ti-6Al-4V: wear and corrosion characterization in simulated biofluid. J Biomater Appl 21(1):49–73CrossRefPubMed Singh R, Kurella A, Dahotre NB (2006) Laser surface modification of Ti-6Al-4V: wear and corrosion characterization in simulated biofluid. J Biomater Appl 21(1):49–73CrossRefPubMed
27.
go back to reference Biswas A, Li L, Maity TK, Chatterjee UK, Mordike BL, Manna I, Dutta MJ (2007) Laser surface treatment of Ti-6Al-4V for bio-implant application. Lasers Eng 17:59–73 Biswas A, Li L, Maity TK, Chatterjee UK, Mordike BL, Manna I, Dutta MJ (2007) Laser surface treatment of Ti-6Al-4V for bio-implant application. Lasers Eng 17:59–73
28.
go back to reference Zaveri N, Mahapatra M, Deceuster A, Peng Y, Li L, Zhou A (2008) Corrosion resistance of pulsed laser-treated Ti-6Al-4V implant in simulated biofluids. Electrochim Acta 53(15):5022–5032CrossRef Zaveri N, Mahapatra M, Deceuster A, Peng Y, Li L, Zhou A (2008) Corrosion resistance of pulsed laser-treated Ti-6Al-4V implant in simulated biofluids. Electrochim Acta 53(15):5022–5032CrossRef
Metadata
Title
Corrosion behavior of erbium chromium-doped yattrium-scandium-gallium-garnet (Er,Cr:YSGG 2780 nm) laser-treated titanium alloy used for dental applications at different pH conditions (in vitro study)
Authors
Dalia A. Abd El daym
Mostafa E. Gheith
Nadia A. Abbas
Laila A. Rashed
Zeinab A. Abd El Aziz
Publication date
01-09-2018
Publisher
Springer International Publishing
Published in
Lasers in Dental Science / Issue 3/2018
Electronic ISSN: 2367-2587
DOI
https://doi.org/10.1007/s41547-018-0030-7

Other articles of this Issue 3/2018

Lasers in Dental Science 3/2018 Go to the issue