Does Site Matter? Impact of Inertial Measurement Unit Placement on the Validity and Reliability of Stride Variables During Running: A Systematic Review and Meta-analysis

Authors: Benjamin J. Horsley, Paul J. Tofari, Shona L. Halson, Justin G. Kemp, Jessica Dickson, Nirav Maniar, Stuart J. Cormack

Published in: Sports Medicine | Issue 7/2021

Login to get access

Abstract

Background

Inertial measurement units (IMUs) are used for running gait analysis in a variety of sports. These sensors have been attached at various locations to capture stride data. However, it is unclear if different placement sites affect the derived outcome measures.

Objective

The aim of this systematic review and meta-analysis was to investigate the impact of placement on the validity and reliability of IMU-derived measures of running gait.

Methods

Online databases SPORTDiscus with Full Text, CINAHL Complete, MEDLINE (EBSCOhost), EMBASE (Ovid) and Scopus were searched from the earliest record to 6 August 2020. Articles were included if they (1) used an IMU during running (2) reported spatiotemporal variables, peak ground reaction force (GRF) or vertical stiffness and (3) assessed validity or reliability. Meta-analyses were performed for a pooled validity estimate when (1) studies reported means and standard deviation for variables derived from the IMU and criterion (2) used the same IMU placement and (3) determined validity at a comparable running velocity (≤ 1 m·s−1 difference).

Results

Thirty-nine articles were included, where placement varied between the foot, tibia, hip, sacrum, lumbar spine (LS), torso and thoracic spine (TS). Initial contact, toe-off, contact time (CT), flight time (FT), step time, stride time, swing time, step frequency (SF), step length (SL), stride length, peak vertical and resultant GRF and vertical stiffness were analysed. Four variables (CT, FT, SF and SL) were meta-analysed, where CT was compared between the foot, tibia and LS placements and SF was compared between foot and LS. Foot placement data were meta-analysed for FT and SL. All data are the mean difference (MD [95%CI]). No significant difference was observed for any site compared to the criterion for CT (foot: − 11.47 ms [− 45.68, 22.74], p = 0.43; tibia: 22.34 ms [− 18.59, 63.27], p = 0.18; LS: − 48.74 ms [− 120.33, 22.85], p = 0.12), FT (foot: 11.93 ms [− 8.88, 32.74], p = 0.13), SF (foot: 0.45 step·min−1 [− 1.75, 2.66], p = 0.47; LS: − 3.45 step·min−1 [− 16.28, 9.39], p = 0.37) and SL (foot: 0.21 cm [− 1.76, 2.18], p = 0.69). Reliable derivations of CT (coefficient of variation [CV] < 9.9%), FT (CV < 11.6%) and SF (CV < 4.4%) were shown using foot- and LS-worn IMUs, while the CV was < 7.8% for foot-determined stride time, SL and stride length. Vertical GRF was reliable from the LS (CV = 4.2%) and TS (CV = 3.3%) using a spring-mass model, while vertical stiffness was moderately (r = 0.66) and nearly perfectly (r = 0.98) correlated with criterion measures from the TS.

Conclusion

Placement of IMUs on the foot, tibia and LS is suitable to derive valid and reliable stride data, suggesting measurement site may not be a critical factor. However, evidence regarding the ability to accurately detect stride events from the TS is unclear and this warrants further investigation.
Appendix
Available only for authorised users
Literature
1.
go back to reference Vanrenterghem J, Nedergaard N, Robinson MA, Drust B. Training load monitoring in team sports: a novel framework separating physiological and biomechanical load-adaptation pathways. Sports Med. 2017;47(11):2135–42.PubMedCrossRef Vanrenterghem J, Nedergaard N, Robinson MA, Drust B. Training load monitoring in team sports: a novel framework separating physiological and biomechanical load-adaptation pathways. Sports Med. 2017;47(11):2135–42.PubMedCrossRef
2.
go back to reference Spencer M, Lawrence S, Rechichi C, Bishop D, Dawson B, Goodman C. Time–motion analysis of elite field hockey, with special reference to repeated-sprint activity. J Sport Sci. 2004;22(9):843–50.CrossRef Spencer M, Lawrence S, Rechichi C, Bishop D, Dawson B, Goodman C. Time–motion analysis of elite field hockey, with special reference to repeated-sprint activity. J Sport Sci. 2004;22(9):843–50.CrossRef
3.
go back to reference Aughey RJ. Applications of GPS technologies to field sports. Int J Sports Physiol Perform. 2011;6(3):295–310.PubMedCrossRef Aughey RJ. Applications of GPS technologies to field sports. Int J Sports Physiol Perform. 2011;6(3):295–310.PubMedCrossRef
4.
go back to reference Buchheit M, Allen A, Poon TK, Modonutti M, Gregson W, Di Salvo V. Integrating different tracking systems in football: multiple camera semi-automatic system, local position measurement and GPS technologies. J Sport Sci. 2014;32(20):1844–57.CrossRef Buchheit M, Allen A, Poon TK, Modonutti M, Gregson W, Di Salvo V. Integrating different tracking systems in football: multiple camera semi-automatic system, local position measurement and GPS technologies. J Sport Sci. 2014;32(20):1844–57.CrossRef
5.
go back to reference Stevens TG, de Ruiter CJ, van Niel C, van de Rhee R, Beek PJ, Savelsbergh GJ. Measuring acceleration and deceleration in soccer-specific movements using a local position measurement (LPM) system. Int J Sports Physiol Perform. 2014;9(3):446–56.CrossRef Stevens TG, de Ruiter CJ, van Niel C, van de Rhee R, Beek PJ, Savelsbergh GJ. Measuring acceleration and deceleration in soccer-specific movements using a local position measurement (LPM) system. Int J Sports Physiol Perform. 2014;9(3):446–56.CrossRef
6.
go back to reference Duffield R, Reid M, Baker J, Spratford W. Accuracy and reliability of GPS devices for measurement of movement patterns in confined spaces for court-based sports. J Sci Med Sport. 2010;13(5):523–5.PubMedCrossRef Duffield R, Reid M, Baker J, Spratford W. Accuracy and reliability of GPS devices for measurement of movement patterns in confined spaces for court-based sports. J Sci Med Sport. 2010;13(5):523–5.PubMedCrossRef
7.
go back to reference Jennings D, Cormack S, Coutts AJ, Boyd L, Aughey RJ. The validity and reliability of GPS units for measuring distance in team sport specific running patterns. Int J Sports Physiol Perform. 2010;5(3):328–41.PubMedCrossRef Jennings D, Cormack S, Coutts AJ, Boyd L, Aughey RJ. The validity and reliability of GPS units for measuring distance in team sport specific running patterns. Int J Sports Physiol Perform. 2010;5(3):328–41.PubMedCrossRef
8.
go back to reference Varley MC, Fairweather IH, Aughey RJ. Validity and reliability of GPS for measuring instantaneous velocity during acceleration, deceleration, and constant motion. J Sport Sci. 2012;30(2):121–7.CrossRef Varley MC, Fairweather IH, Aughey RJ. Validity and reliability of GPS for measuring instantaneous velocity during acceleration, deceleration, and constant motion. J Sport Sci. 2012;30(2):121–7.CrossRef
9.
go back to reference Gabbett T, Jenkins D, Abernethy B. Physical collisions and injury during professional rugby league skills training. J Sci Med Sport. 2010;13(6):578–83.PubMedCrossRef Gabbett T, Jenkins D, Abernethy B. Physical collisions and injury during professional rugby league skills training. J Sci Med Sport. 2010;13(6):578–83.PubMedCrossRef
10.
go back to reference Boyd LJ, Ball K, Aughey RJ. Quantifying external load in Australian football matches and training using accelerometers. Int J Sports Physiol Perform. 2013;8(1):44–51.PubMedCrossRef Boyd LJ, Ball K, Aughey RJ. Quantifying external load in Australian football matches and training using accelerometers. Int J Sports Physiol Perform. 2013;8(1):44–51.PubMedCrossRef
11.
go back to reference Gastin PB, McLean O, Spittle M, Breed RV. Quantification of tackling demands in professional Australian football using integrated wearable athlete tracking technology. J Sci Med Sport. 2013;16(6):589–93.PubMedCrossRef Gastin PB, McLean O, Spittle M, Breed RV. Quantification of tackling demands in professional Australian football using integrated wearable athlete tracking technology. J Sci Med Sport. 2013;16(6):589–93.PubMedCrossRef
12.
go back to reference Gastin PB, Mclean OC, Breed RV, Spittle M. Tackle and impact detection in elite Australian football using wearable microsensor technology. J Sport Sci. 2014;32(10):947–53.CrossRef Gastin PB, Mclean OC, Breed RV, Spittle M. Tackle and impact detection in elite Australian football using wearable microsensor technology. J Sport Sci. 2014;32(10):947–53.CrossRef
14.
go back to reference Warman GE, Cole MH, Johnston RD, Chalkley D, Pepping G-J. Using microtechnology to quantify torso angle during match-play in field hockey. J Strength Cond Res. 2019;33(10):2648–54.PubMedCrossRef Warman GE, Cole MH, Johnston RD, Chalkley D, Pepping G-J. Using microtechnology to quantify torso angle during match-play in field hockey. J Strength Cond Res. 2019;33(10):2648–54.PubMedCrossRef
15.
go back to reference Boyd LJ, Ball K, Aughey RJ. The reliability of MinimaxX accelerometers for measuring physical activity in Australian football. Int J Sports Physiol Perform. 2011;6(3):311–21.PubMedCrossRef Boyd LJ, Ball K, Aughey RJ. The reliability of MinimaxX accelerometers for measuring physical activity in Australian football. Int J Sports Physiol Perform. 2011;6(3):311–21.PubMedCrossRef
16.
go back to reference Ammann R, Taube W, Wyss T. Accuracy of PARTwear inertial sensor and Optojump optical measurement system for measuring ground contact time during running. J Strength Cond Res. 2016;30(7):2057–63.PubMedCrossRef Ammann R, Taube W, Wyss T. Accuracy of PARTwear inertial sensor and Optojump optical measurement system for measuring ground contact time during running. J Strength Cond Res. 2016;30(7):2057–63.PubMedCrossRef
17.
go back to reference Gabbett TJ. Quantifying the physical demands of collision sports: does microsensor technology measure what it claims to measure? J Strength Cond Res. 2013;27(8):2319–22.PubMedCrossRef Gabbett TJ. Quantifying the physical demands of collision sports: does microsensor technology measure what it claims to measure? J Strength Cond Res. 2013;27(8):2319–22.PubMedCrossRef
18.
go back to reference Bouten CV, Westerterp KR, Verduin M, Janssen JD. Assessment of energy expenditure for physical activity using a triaxial accelerometer. Med Sci Sports Exerc. 1994;26(12):1516–23.PubMedCrossRef Bouten CV, Westerterp KR, Verduin M, Janssen JD. Assessment of energy expenditure for physical activity using a triaxial accelerometer. Med Sci Sports Exerc. 1994;26(12):1516–23.PubMedCrossRef
19.
go back to reference Bouten CV, Koekkoek KT, Verduin M, Kodde R, Janssen JD. A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity. IEEE Trans Biomed Eng. 1997;44(3):136–47.PubMedCrossRef Bouten CV, Koekkoek KT, Verduin M, Kodde R, Janssen JD. A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity. IEEE Trans Biomed Eng. 1997;44(3):136–47.PubMedCrossRef
20.
go back to reference Swartz AM, Strath SJ, Bassett DR, O’Brien WL, King GA, Ainsworth BE. Estimation of energy expenditure using CSA accelerometers at hip and wrist sites. Med Sci Sports Exerc. 2000;32(9):450–6.CrossRef Swartz AM, Strath SJ, Bassett DR, O’Brien WL, King GA, Ainsworth BE. Estimation of energy expenditure using CSA accelerometers at hip and wrist sites. Med Sci Sports Exerc. 2000;32(9):450–6.CrossRef
21.
go back to reference Troiano RP, Berrigan D, Dodd KW, Masse LC, Tilert T, McDowell M. Physical activity in the United States measured by accelerometer. Med Sci Sports Exerc. 2008;40(1):181–8.CrossRef Troiano RP, Berrigan D, Dodd KW, Masse LC, Tilert T, McDowell M. Physical activity in the United States measured by accelerometer. Med Sci Sports Exerc. 2008;40(1):181–8.CrossRef
22.
go back to reference Skotte J, Korshøj M, Kristiansen J, Hanisch C, Holtermann A. Detection of physical activity types using triaxial accelerometers. J Phys Act Health. 2014;11(1):76–84.PubMedCrossRef Skotte J, Korshøj M, Kristiansen J, Hanisch C, Holtermann A. Detection of physical activity types using triaxial accelerometers. J Phys Act Health. 2014;11(1):76–84.PubMedCrossRef
23.
go back to reference McNamara DJ, Gabbett TJ, Chapman P, Naughton G, Farhart P. The validity of microsensors to automatically detect bowling events and counts in cricket fast bowlers. Int J Sports Physiol Perform. 2015;10(1):71–5.PubMedCrossRef McNamara DJ, Gabbett TJ, Chapman P, Naughton G, Farhart P. The validity of microsensors to automatically detect bowling events and counts in cricket fast bowlers. Int J Sports Physiol Perform. 2015;10(1):71–5.PubMedCrossRef
24.
go back to reference Murray NB, Black GM, Whiteley RJ, Gahan P, Cole MH, Utting A, et al. Automatic detection of pitching and throwing events in baseball with inertial measurement sensors. Int J Sports Physiol Perform. 2017;12(4):533–7.PubMedCrossRef Murray NB, Black GM, Whiteley RJ, Gahan P, Cole MH, Utting A, et al. Automatic detection of pitching and throwing events in baseball with inertial measurement sensors. Int J Sports Physiol Perform. 2017;12(4):533–7.PubMedCrossRef
26.
go back to reference Barrett S, Midgley A, Lovell R. PlayerLoad(TM): reliability, convergent validity, and influence of unit position during treadmill running. Int J Sports Physiol Perform. 2014;9(6):945–52.PubMedCrossRef Barrett S, Midgley A, Lovell R. PlayerLoad(TM): reliability, convergent validity, and influence of unit position during treadmill running. Int J Sports Physiol Perform. 2014;9(6):945–52.PubMedCrossRef
27.
go back to reference Mooney MG, Cormack S, O’Brien BJ, Morgan WM, McGuigan M. Impact of neuromuscular fatigue on match exercise intensity and performance in elite Australian football. J Strength Cond Res. 2013;27(1):166–73.PubMedCrossRef Mooney MG, Cormack S, O’Brien BJ, Morgan WM, McGuigan M. Impact of neuromuscular fatigue on match exercise intensity and performance in elite Australian football. J Strength Cond Res. 2013;27(1):166–73.PubMedCrossRef
28.
go back to reference Cormack SJ, Mooney MG, Morgan W, McGuigan MR. Influence of neuromuscular fatigue on accelerometer load in elite Australian football players. Int J Sports Physiol Perform. 2013;8(4):373–8.PubMedCrossRef Cormack SJ, Mooney MG, Morgan W, McGuigan MR. Influence of neuromuscular fatigue on accelerometer load in elite Australian football players. Int J Sports Physiol Perform. 2013;8(4):373–8.PubMedCrossRef
29.
go back to reference McGrath D, Greene BR, O’Donovan KJ, Caulfield B. Gyroscope-based assessment of temporal gait parameters during treadmill walking and running. Sports Eng. 2012;15(4):207–13.CrossRef McGrath D, Greene BR, O’Donovan KJ, Caulfield B. Gyroscope-based assessment of temporal gait parameters during treadmill walking and running. Sports Eng. 2012;15(4):207–13.CrossRef
32.
go back to reference Lee JB, Mellifont RB, Burkett BJ. The use of a single inertial sensor to identify stride, step, and stance durations of running gait. J Sci Med Sport. 2010;13(2):270–3.PubMedCrossRef Lee JB, Mellifont RB, Burkett BJ. The use of a single inertial sensor to identify stride, step, and stance durations of running gait. J Sci Med Sport. 2010;13(2):270–3.PubMedCrossRef
33.
go back to reference Bergamini E, Picerno P, Pillet H, Natta F, Thoreux P, Camomilla V. Estimation of temporal parameters during sprint running using a trunk-mounted inertial measurement unit. J Biomech. 2012;45(6):1123–6.PubMedCrossRef Bergamini E, Picerno P, Pillet H, Natta F, Thoreux P, Camomilla V. Estimation of temporal parameters during sprint running using a trunk-mounted inertial measurement unit. J Biomech. 2012;45(6):1123–6.PubMedCrossRef
36.
go back to reference Wundersitz DWT, Netto KJ, Aisbett B, Gastin PB. Validity of an upper-body-mounted accelerometer to measure peak vertical and resultant force during running and change-of-direction tasks. Sports Biomech. 2013;12(4):403–12.PubMedCrossRef Wundersitz DWT, Netto KJ, Aisbett B, Gastin PB. Validity of an upper-body-mounted accelerometer to measure peak vertical and resultant force during running and change-of-direction tasks. Sports Biomech. 2013;12(4):403–12.PubMedCrossRef
37.
go back to reference Buchheit M, Gray A, Morin JB. Assessing stride variables and vertical stiffness with GPS-embedded accelerometers: preliminary insights for the monitoring of neuromuscular fatigue on the field. J Sports Sci Med. 2015;14:698–701.PubMedPubMedCentral Buchheit M, Gray A, Morin JB. Assessing stride variables and vertical stiffness with GPS-embedded accelerometers: preliminary insights for the monitoring of neuromuscular fatigue on the field. J Sports Sci Med. 2015;14:698–701.PubMedPubMedCentral
38.
go back to reference Eggers TM, Massard TI, Clothier PJ, Lovell R. Measuring vertical stiffness in sport with accelerometers: exercise caution! J Strength Cond Res. 2018;32(7):1919–22.PubMedCrossRef Eggers TM, Massard TI, Clothier PJ, Lovell R. Measuring vertical stiffness in sport with accelerometers: exercise caution! J Strength Cond Res. 2018;32(7):1919–22.PubMedCrossRef
40.
go back to reference Raper DP, Witchalls J, Philips EJ, Knight E, Drew MK, Waddington G. Use of a tibial accelerometer to measure ground reaction force in running: a reliability and validity comparison with force plates. J Sci Med Sport. 2018;21(1):84–8.PubMedCrossRef Raper DP, Witchalls J, Philips EJ, Knight E, Drew MK, Waddington G. Use of a tibial accelerometer to measure ground reaction force in running: a reliability and validity comparison with force plates. J Sci Med Sport. 2018;21(1):84–8.PubMedCrossRef
41.
go back to reference Dugan SA, Bhat KP. Biomechanics and analysis of running gait. Phys Med Rehabil Clin N Am. 2005;16(3):603–21.PubMedCrossRef Dugan SA, Bhat KP. Biomechanics and analysis of running gait. Phys Med Rehabil Clin N Am. 2005;16(3):603–21.PubMedCrossRef
42.
go back to reference Nedergaard NJ, Robinson MA, Eusterwiemann E, Drust B, Lisboa PJ, Vanrenterghem J. The relationship between whole-body external loading and body-worn accelerometry during team-sport movements. Int J Sports Physiol Perform. 2017;12(1):18–26.PubMedCrossRef Nedergaard NJ, Robinson MA, Eusterwiemann E, Drust B, Lisboa PJ, Vanrenterghem J. The relationship between whole-body external loading and body-worn accelerometry during team-sport movements. Int J Sports Physiol Perform. 2017;12(1):18–26.PubMedCrossRef
43.
go back to reference Edwards S, White S, Humphreys S, Robergs R, O’Dwyer N. Caution using data from triaxial accelerometers housed in player tracking units during running. J Sport Sci. 2019;37(7):810–8.CrossRef Edwards S, White S, Humphreys S, Robergs R, O’Dwyer N. Caution using data from triaxial accelerometers housed in player tracking units during running. J Sport Sci. 2019;37(7):810–8.CrossRef
45.
go back to reference Lafortune MA, Lake MJ, Hennig EM. Differential shock transmission response of the human body to impact severity and lower limb posture. J Biomech. 1996;29(12):1531–7.PubMedCrossRef Lafortune MA, Lake MJ, Hennig EM. Differential shock transmission response of the human body to impact severity and lower limb posture. J Biomech. 1996;29(12):1531–7.PubMedCrossRef
48.
go back to reference Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Ann Intern Med. 2009;151(4):264–9.CrossRef Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Ann Intern Med. 2009;151(4):264–9.CrossRef
49.
go back to reference Downs SH, Black N. The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions. J Epidemiol Community Health. 1998;52(6):377–84.PubMedPubMedCentralCrossRef Downs SH, Black N. The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions. J Epidemiol Community Health. 1998;52(6):377–84.PubMedPubMedCentralCrossRef
50.
go back to reference Cummins C, Orr R, O’Connor H, West C. Global positioning systems (GPS) and microtechnology sensors in team sports: a systematic review. Sports Med. 2013;43(10):1025–42.PubMedCrossRef Cummins C, Orr R, O’Connor H, West C. Global positioning systems (GPS) and microtechnology sensors in team sports: a systematic review. Sports Med. 2013;43(10):1025–42.PubMedCrossRef
52.
go back to reference Chew D-K, Ngoh KJ, Gouwanda D, Gopalai AA. Estimating running spatial and temporal parameters using an inertial sensor. Sports Eng. 2018;21(2):115–22.CrossRef Chew D-K, Ngoh KJ, Gouwanda D, Gopalai AA. Estimating running spatial and temporal parameters using an inertial sensor. Sports Eng. 2018;21(2):115–22.CrossRef
54.
go back to reference Kenneally-Dabrowski CJ, Serpell BG, Spratford W. Are accelerometers a valid tool for measuring overground sprinting symmetry? Int J Sports Sci Coach. 2018;13(2):270–7.CrossRef Kenneally-Dabrowski CJ, Serpell BG, Spratford W. Are accelerometers a valid tool for measuring overground sprinting symmetry? Int J Sports Sci Coach. 2018;13(2):270–7.CrossRef
62.
go back to reference Sinclair J, Hobbs SJ, Protheroe L, Edmundson CJ, Greenhalgh A. Determination of gait events using an externally mounted shank accelerometer. J Appl Biomech. 2013;29(1):118–22.PubMedCrossRef Sinclair J, Hobbs SJ, Protheroe L, Edmundson CJ, Greenhalgh A. Determination of gait events using an externally mounted shank accelerometer. J Appl Biomech. 2013;29(1):118–22.PubMedCrossRef
64.
go back to reference Winter SC, Lee JB, Leadbetter RI, Gordon SJ. Validation of a single inertial sensor for measuring running kinematics overground during a prolonged run. J Fit Res. 2016;5(1):14–23. Winter SC, Lee JB, Leadbetter RI, Gordon SJ. Validation of a single inertial sensor for measuring running kinematics overground during a prolonged run. J Fit Res. 2016;5(1):14–23.
67.
go back to reference Hall JP, Barton C, Jones PR, Morrissey D. The biomechanical differences between barefoot and shod distance running: a systematic review and preliminary meta-analysis. Sports Med. 2013;43(12):1335–53.PubMedCrossRef Hall JP, Barton C, Jones PR, Morrissey D. The biomechanical differences between barefoot and shod distance running: a systematic review and preliminary meta-analysis. Sports Med. 2013;43(12):1335–53.PubMedCrossRef
68.
go back to reference Gindre C, Lussiana T, Hebert-Losier K, Morin J-B. Reliability and validity of the Myotest for measuring running stride kinematics. J Sport Sci. 2016;34(7):664–70.CrossRef Gindre C, Lussiana T, Hebert-Losier K, Morin J-B. Reliability and validity of the Myotest for measuring running stride kinematics. J Sport Sci. 2016;34(7):664–70.CrossRef
73.
go back to reference Simon SR. Quantification of human motion: gait analysis—benefits and limitations to its application to clinical problems. J Biomech. 2004;37(12):1869–80.PubMedCrossRef Simon SR. Quantification of human motion: gait analysis—benefits and limitations to its application to clinical problems. J Biomech. 2004;37(12):1869–80.PubMedCrossRef
74.
go back to reference Lienhard K, Schneider D, Maffiuletti NA. Validity of the Optogait photoelectric system for the assessment of spatiotemporal gait parameters. Med Eng Phys. 2013;35(4):500–4.PubMedCrossRef Lienhard K, Schneider D, Maffiuletti NA. Validity of the Optogait photoelectric system for the assessment of spatiotemporal gait parameters. Med Eng Phys. 2013;35(4):500–4.PubMedCrossRef
75.
go back to reference Muro-de-la-Herran A, Garcia-Zapirain B, Mendez-Zorrilla A. Gait analysis methods: an overview of wearable and non-wearable systems, highlighting clinical applications. Sensors. 2014;14(2):3362–94.PubMedPubMedCentralCrossRef Muro-de-la-Herran A, Garcia-Zapirain B, Mendez-Zorrilla A. Gait analysis methods: an overview of wearable and non-wearable systems, highlighting clinical applications. Sensors. 2014;14(2):3362–94.PubMedPubMedCentralCrossRef
76.
go back to reference Schwarzer G. meta: an R package for meta-analysis. R News. 2007;7(3):40–5. Schwarzer G. meta: an R package for meta-analysis. R News. 2007;7(3):40–5.
78.
go back to reference Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. Br Med J. 2003;327(7414):557–60.CrossRef Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. Br Med J. 2003;327(7414):557–60.CrossRef
79.
go back to reference Viechtbauer W, Cheung MWL. Outlier and influence diagnostics for meta-analysis. Res Synth Methods. 2010;1(2):112–25.PubMedCrossRef Viechtbauer W, Cheung MWL. Outlier and influence diagnostics for meta-analysis. Res Synth Methods. 2010;1(2):112–25.PubMedCrossRef
81.
go back to reference Schwarzer G, Carpenter JR, Rücker G. Meta-analysis with R. Use R! 1st ed. Cham: Springer International Publishing Switzerland; 2015.CrossRef Schwarzer G, Carpenter JR, Rücker G. Meta-analysis with R. Use R! 1st ed. Cham: Springer International Publishing Switzerland; 2015.CrossRef
82.
go back to reference Lewis S, Clarke M. Forest plots: trying to see the wood and the trees. Br Med J. 2001;322(7300):1479–80.CrossRef Lewis S, Clarke M. Forest plots: trying to see the wood and the trees. Br Med J. 2001;322(7300):1479–80.CrossRef
83.
go back to reference Gouttebarge V, Wolfard R, Griek N, de Ruiter CJ, Boschman JS, van Dieën JH. Reproducibility and validity of the Myotest for measuring step frequency and ground contact time in recreational runners. J Hum Kinet. 2015;45:19–26.PubMedPubMedCentralCrossRef Gouttebarge V, Wolfard R, Griek N, de Ruiter CJ, Boschman JS, van Dieën JH. Reproducibility and validity of the Myotest for measuring step frequency and ground contact time in recreational runners. J Hum Kinet. 2015;45:19–26.PubMedPubMedCentralCrossRef
84.
go back to reference Norris M, Kenny IC, Anderson R. Comparison of accelerometry stride time calculation methods. J Biomech. 2016;49(13):3031–4.PubMedCrossRef Norris M, Kenny IC, Anderson R. Comparison of accelerometry stride time calculation methods. J Biomech. 2016;49(13):3031–4.PubMedCrossRef
85.
go back to reference Brahms C, Zhao Y, Gerhard D, Barden JM. Stride length determination during overground running using a single foot-mounted inertial measurement unit. J Biomech. 2018;71:302–5.PubMedCrossRef Brahms C, Zhao Y, Gerhard D, Barden JM. Stride length determination during overground running using a single foot-mounted inertial measurement unit. J Biomech. 2018;71:302–5.PubMedCrossRef
86.
go back to reference Buchheit M, Lacome M, Cholley Y, Simpson BM. Neuromuscular responses to conditioned soccer sessions assessed via GPS-embedded accelerometers: insights into tactical periodization. Int J Sports Physiol Perform. 2018;13:577–83.PubMedCrossRef Buchheit M, Lacome M, Cholley Y, Simpson BM. Neuromuscular responses to conditioned soccer sessions assessed via GPS-embedded accelerometers: insights into tactical periodization. Int J Sports Physiol Perform. 2018;13:577–83.PubMedCrossRef
88.
go back to reference Powers DM. Evaluation: from precision, recall and F-measure to ROC, informedness, markedness and correlation. J Mach Learn Technol. 2011;2(1):37–63. Powers DM. Evaluation: from precision, recall and F-measure to ROC, informedness, markedness and correlation. J Mach Learn Technol. 2011;2(1):37–63.
89.
go back to reference Hreljac A, Marshall RN. Algorithms to determine event timing during normal walking using kinematic data. J Biomech. 2000;33(6):783–6.PubMedCrossRef Hreljac A, Marshall RN. Algorithms to determine event timing during normal walking using kinematic data. J Biomech. 2000;33(6):783–6.PubMedCrossRef
90.
go back to reference Zeni J Jr, Richards J, Higginson J. Two simple methods for determining gait events during treadmill and overground walking using kinematic data. Gait Posture. 2008;27(4):710–4.PubMedCrossRef Zeni J Jr, Richards J, Higginson J. Two simple methods for determining gait events during treadmill and overground walking using kinematic data. Gait Posture. 2008;27(4):710–4.PubMedCrossRef
93.
go back to reference Keller TS, Weisberger A, Ray J, Hasan SS, Shiavi RG, Spengler DM. Relationship between vertical ground reaction force and speed during walking, slow jogging, and running. Clin Biomech. 1996;11(5):253–9.CrossRef Keller TS, Weisberger A, Ray J, Hasan SS, Shiavi RG, Spengler DM. Relationship between vertical ground reaction force and speed during walking, slow jogging, and running. Clin Biomech. 1996;11(5):253–9.CrossRef
94.
go back to reference Hunter JP, Marshall RN, McNair PJ. Relationships between ground reaction force impulse and kinematics of sprint-running acceleration. J Appl Biomech. 2005;21(1):31–43.PubMedCrossRef Hunter JP, Marshall RN, McNair PJ. Relationships between ground reaction force impulse and kinematics of sprint-running acceleration. J Appl Biomech. 2005;21(1):31–43.PubMedCrossRef
95.
go back to reference Verheul J, Nedergaard NJ, Vanrenterghem J, Robinson MA. Measuring biomechanical loads in team sports—from lab to field. Sci Med Footb. 2020;4:1–7. Verheul J, Nedergaard NJ, Vanrenterghem J, Robinson MA. Measuring biomechanical loads in team sports—from lab to field. Sci Med Footb. 2020;4:1–7.
96.
go back to reference Morin J-B, Dalleau G, Kyröläinen H, Jeannin T, Belli A. A simple method for measuring stiffness during running. J Appl Biomech. 2005;21(2):167–80.PubMedCrossRef Morin J-B, Dalleau G, Kyröläinen H, Jeannin T, Belli A. A simple method for measuring stiffness during running. J Appl Biomech. 2005;21(2):167–80.PubMedCrossRef
98.
99.
go back to reference Cormack SJ, Newton RU, McGuigan MR, Doyle TL. Reliability of measures obtained during single and repeated countermovement jumps. Int J Sports Physiol Perform. 2008;3(2):131–44.PubMedCrossRef Cormack SJ, Newton RU, McGuigan MR, Doyle TL. Reliability of measures obtained during single and repeated countermovement jumps. Int J Sports Physiol Perform. 2008;3(2):131–44.PubMedCrossRef
100.
go back to reference Thorborg K, Petersen J, Magnusson SP, Hölmich P. Clinical assessment of hip strength using a hand-held dynamometer is reliable. Scand J Med Sci Sports. 2010;20(3):493–501.PubMedCrossRef Thorborg K, Petersen J, Magnusson SP, Hölmich P. Clinical assessment of hip strength using a hand-held dynamometer is reliable. Scand J Med Sci Sports. 2010;20(3):493–501.PubMedCrossRef
101.
go back to reference Garrett J, Graham SR, Eston RG, Burgess DJ, Garrett LJ, Jakeman J, et al. A novel method of assessment for monitoring neuromuscular fatigue in Australian rules football players. Int J Sports Physiol Perform. 2018;14(5):598–605.CrossRef Garrett J, Graham SR, Eston RG, Burgess DJ, Garrett LJ, Jakeman J, et al. A novel method of assessment for monitoring neuromuscular fatigue in Australian rules football players. Int J Sports Physiol Perform. 2018;14(5):598–605.CrossRef
103.
go back to reference Walker EJ, McAinch AJ, Sweeting A, Aughey RJ. Inertial sensors to estimate the energy expenditure of team-sport athletes. J Sci Med Sport. 2016;19(2):177–81.PubMedCrossRef Walker EJ, McAinch AJ, Sweeting A, Aughey RJ. Inertial sensors to estimate the energy expenditure of team-sport athletes. J Sci Med Sport. 2016;19(2):177–81.PubMedCrossRef
104.
go back to reference Wundersitz DW, Gastin PB, Richter C, Robertson SJ, Netto KJ. Validity of a trunk-mounted accelerometer to assess peak accelerations during walking, jogging and running. Eur J Sport Sci. 2015;15(5):382–90.PubMedCrossRef Wundersitz DW, Gastin PB, Richter C, Robertson SJ, Netto KJ. Validity of a trunk-mounted accelerometer to assess peak accelerations during walking, jogging and running. Eur J Sport Sci. 2015;15(5):382–90.PubMedCrossRef
Metadata
Title
Does Site Matter? Impact of Inertial Measurement Unit Placement on the Validity and Reliability of Stride Variables During Running: A Systematic Review and Meta-analysis
Authors
Benjamin J. Horsley
Paul J. Tofari
Shona L. Halson
Justin G. Kemp
Jessica Dickson
Nirav Maniar
Stuart J. Cormack
Publication date
01-07-2021
Publisher
Springer International Publishing
Published in
Sports Medicine / Issue 7/2021
Print ISSN: 0112-1642
Electronic ISSN: 1179-2035
DOI
https://doi.org/10.1007/s40279-021-01443-8

Other articles of this Issue 7/2021

Sports Medicine 7/2021 Go to the issue