Abstract

One of the considerable challenges for screw-retained multi-unit implant prosthesis is achieving a passive fit of the prosthesis’ superstructure to the implants. This passive fit is supposed to be one of the most vital requirements for the maintenance of the osseointegration. On the other hand, the misfit of the implant supported superstructure may lead to unfavourable complications, which can be mechanical or biological in nature. The manifestations of these complications may range from fracture of various components in the implant system, pain, marginal bone loss, and even loss of osseointegration. Thus, minimizing the misfit and optimizing the passive fit should be a prerequisite for implant survival and success. The purpose of this article is to present and summarize some aspects of the passive fit achieving and improving methods. The literature review was performed through Science Direct, Pubmed, and Google database. They were searched in English using the following combinations of keywords: passive fit, implant misfit and framework misfit. Articles were selected on the basis of whether they had sufficient information related to framework misfit’s related factors, passive fit and its achievement techniques, marginal bone changes relation with the misfit, implant impression techniques and splinting concept. The related references were selected in order to emphasize the importance of the passive fit achievement and the misfit minimizing. Despite the fact that the literature presents considerable information regarding the framework’s misfit, there was not consistency in literature on a specified number or even a range to be the acceptable level of misfit. On the other hand, a review of the literature revealed that the complete passive fit still remains a tricky goal to be achieved by the prosthodontist.
Literature
1.
go back to reference Michalakis KX, Hirayama H (2003) Garefis PDCement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants 18:719–728PubMed Michalakis KX, Hirayama H (2003) Garefis PDCement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants 18:719–728PubMed
2.
go back to reference Assif D, Marshak B, Schmidt A (1996) Accuracy of implant impression techniques. Int J Oral Maxillofac Implants 11:216–222PubMed Assif D, Marshak B, Schmidt A (1996) Accuracy of implant impression techniques. Int J Oral Maxillofac Implants 11:216–222PubMed
3.
go back to reference Assif D, Marshak B, Nissan J (1994) A modified impression technique for implant-supported restoration. J Prosthet Dent 71:589–591PubMedCrossRef Assif D, Marshak B, Nissan J (1994) A modified impression technique for implant-supported restoration. J Prosthet Dent 71:589–591PubMedCrossRef
4.
go back to reference Jemt T (1991) Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 6:270–276PubMed Jemt T (1991) Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 6:270–276PubMed
5.
go back to reference Jemt T, Book K (1996) Prosthesis misfit and marginal bone loss in edentulous implant patients.”. Int J Oral Maxillofac Implants 11:620–625PubMed Jemt T, Book K (1996) Prosthesis misfit and marginal bone loss in edentulous implant patients.”. Int J Oral Maxillofac Implants 11:620–625PubMed
6.
go back to reference Kan JY, Rungcharassaeng K, Bohsali K, Goodacre CJ, Lang BR (1999) Clinical methods for evaluating implant framework fit. J Prosthet Dent 81:7–13PubMedCrossRef Kan JY, Rungcharassaeng K, Bohsali K, Goodacre CJ, Lang BR (1999) Clinical methods for evaluating implant framework fit. J Prosthet Dent 81:7–13PubMedCrossRef
7.
go back to reference Taylor TD, Agar JR, Vogiatzi T (2000) Implant prosthodontics: current perspective and future directions. Int J Oral Maxillofac Implants 15:66–75PubMed Taylor TD, Agar JR, Vogiatzi T (2000) Implant prosthodontics: current perspective and future directions. Int J Oral Maxillofac Implants 15:66–75PubMed
8.
go back to reference Randi AP, Hsu AT, Verga A, Kim JJ (2001) Dimensional accuracy and retentive strength of a retrievable cement-retained implant supported prosthesis. Int J Oral Maxillofac Implants 16:547–556PubMed Randi AP, Hsu AT, Verga A, Kim JJ (2001) Dimensional accuracy and retentive strength of a retrievable cement-retained implant supported prosthesis. Int J Oral Maxillofac Implants 16:547–556PubMed
9.
go back to reference Branemark PI, Zarb GA, Albrektsson T (1985) Tissue -integrated prostheses. Quintessence, Chicago, p 253 Branemark PI, Zarb GA, Albrektsson T (1985) Tissue -integrated prostheses. Quintessence, Chicago, p 253
10.
go back to reference Jemt T, Rubenstein JE, Carlsson L, Lang BR (1996) Measuring fit at the implant prosthodontic interface. J Prosthet Dent 75:314–325PubMedCrossRef Jemt T, Rubenstein JE, Carlsson L, Lang BR (1996) Measuring fit at the implant prosthodontic interface. J Prosthet Dent 75:314–325PubMedCrossRef
11.
go back to reference Wee AG, Aquilino SA, Schneider RL (1999) Strategies to achieve fit in implant prosthodontics: a review of the literature. Int J Prosthodont 12:167–178PubMed Wee AG, Aquilino SA, Schneider RL (1999) Strategies to achieve fit in implant prosthodontics: a review of the literature. Int J Prosthodont 12:167–178PubMed
12.
go back to reference Sorrentino R, Gherlone EF, Calesini G, Zarone F (2010) Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study. Clin Implant Dent Relat Res 12(Suppl 1):e63–e76PubMed Sorrentino R, Gherlone EF, Calesini G, Zarone F (2010) Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study. Clin Implant Dent Relat Res 12(Suppl 1):e63–e76PubMed
13.
go back to reference Ma T, Nicholls JI, Rubenstein JE (1997) Tolerance measurements of various implant components. Int J Oral Maxillofac Implants 12:371–375PubMed Ma T, Nicholls JI, Rubenstein JE (1997) Tolerance measurements of various implant components. Int J Oral Maxillofac Implants 12:371–375PubMed
14.
go back to reference Kim S, Nicholls JI, Han CH, Lee KW (2006) Displacement of implant components from impressions to definitive casts. Int J Oral Maxillofac Implants 21:747–755PubMed Kim S, Nicholls JI, Han CH, Lee KW (2006) Displacement of implant components from impressions to definitive casts. Int J Oral Maxillofac Implants 21:747–755PubMed
15.
go back to reference Roberts WE, Smith RK, Zilberman Y, Mozsary PG, Smith RS (1984) Osseous adaptation to continuous loading of rigid endosseous implants. Am J Orthod 86:95–111PubMedCrossRef Roberts WE, Smith RK, Zilberman Y, Mozsary PG, Smith RS (1984) Osseous adaptation to continuous loading of rigid endosseous implants. Am J Orthod 86:95–111PubMedCrossRef
16.
go back to reference Michaels GC, Carr AB, Larsen PE (1997) Effect of prosthetic superstructure accuracy on the osteointegrated implant bone interface. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 83:198–205PubMedCrossRef Michaels GC, Carr AB, Larsen PE (1997) Effect of prosthetic superstructure accuracy on the osteointegrated implant bone interface. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 83:198–205PubMedCrossRef
17.
go back to reference Klinberged IJ, Murray GM (1985) Design of superstructures for osseointegrated fixtures. Swed Dent J 28:63–69 Klinberged IJ, Murray GM (1985) Design of superstructures for osseointegrated fixtures. Swed Dent J 28:63–69
18.
go back to reference Assuncao WG, Filho HG, Zaniquelli O (2004) Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 13:358–366PubMed Assuncao WG, Filho HG, Zaniquelli O (2004) Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 13:358–366PubMed
19.
go back to reference Lee H, Ercoli C, Funkenbusch PD, Feng C (2008) Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: an in vitro study. J Prosthet Dent 99:107–113PubMedCrossRef Lee H, Ercoli C, Funkenbusch PD, Feng C (2008) Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: an in vitro study. J Prosthet Dent 99:107–113PubMedCrossRef
20.
go back to reference Rashidan N, Alikhasi M, Samadizadeh S, Beyabanaki E, Kharazifard MJ (2009) Accuracy of implant impressions with different impression coping types and shapes. Clin Implant Dent Relat Res 14(2):218–225PubMedCrossRef Rashidan N, Alikhasi M, Samadizadeh S, Beyabanaki E, Kharazifard MJ (2009) Accuracy of implant impressions with different impression coping types and shapes. Clin Implant Dent Relat Res 14(2):218–225PubMedCrossRef
21.
go back to reference Robert G, Craig JMP (2002) Restorative dental materials. Mosby, St. Louis Robert G, Craig JMP (2002) Restorative dental materials. Mosby, St. Louis
22.
go back to reference Daoudi MF, Setchell DJ, Searson LJ (2001) A laboratory investigation of the accuracy of two impression techniques for single-tooth implants.”. Int J Prosthodont 14:152–158PubMed Daoudi MF, Setchell DJ, Searson LJ (2001) A laboratory investigation of the accuracy of two impression techniques for single-tooth implants.”. Int J Prosthodont 14:152–158PubMed
23.
go back to reference Wenz HJ, Hertrampf K (2008) Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection. Int J Oral Maxillofac Implants 23:39–47PubMed Wenz HJ, Hertrampf K (2008) Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection. Int J Oral Maxillofac Implants 23:39–47PubMed
24.
go back to reference Aguilar ML, Augusto Elias, Toro Vizcarrondo CE, Psoter WJ (2009) Analysis of three-dimensional distortion of two impression materials in the transfer of dental implants. J Prosthet Dent 103:202–209CrossRef Aguilar ML, Augusto Elias, Toro Vizcarrondo CE, Psoter WJ (2009) Analysis of three-dimensional distortion of two impression materials in the transfer of dental implants. J Prosthet Dent 103:202–209CrossRef
25.
go back to reference Donovan TE, Chee WW (2004) A review of contemporary impression materials and techniques. Dent Clin North Am 48:445–470CrossRef Donovan TE, Chee WW (2004) A review of contemporary impression materials and techniques. Dent Clin North Am 48:445–470CrossRef
26.
go back to reference Burns J, Palmer R, Howe L, Wilson R (2003) Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays. J Prosthet Dent 89:250–255PubMedCrossRef Burns J, Palmer R, Howe L, Wilson R (2003) Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays. J Prosthet Dent 89:250–255PubMedCrossRef
27.
go back to reference Shen C (2003) Impression material. “K.J. Phillip’s science of dental materials”. Saunders, Philadelphia, pp 205–254 Shen C (2003) Impression material. “K.J. Phillip’s science of dental materials”. Saunders, Philadelphia, pp 205–254
28.
go back to reference Carr AB (1991) Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 6:448–455PubMed Carr AB (1991) Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 6:448–455PubMed
29.
go back to reference Conrad HJ, Pesun IJ, DeLong R, Hodges JS (2007) Accuracy of two impression techniques with angulated implants. J Prosthet Dent 97:349–356PubMedCrossRef Conrad HJ, Pesun IJ, DeLong R, Hodges JS (2007) Accuracy of two impression techniques with angulated implants. J Prosthet Dent 97:349–356PubMedCrossRef
30.
go back to reference Vigolo P, Majzoub Z, Cordioli G (2000) In vitro comparison of master cast accuracy for single-tooth implant replacement. J Prosthet Dent 83:562–566PubMedCrossRef Vigolo P, Majzoub Z, Cordioli G (2000) In vitro comparison of master cast accuracy for single-tooth implant replacement. J Prosthet Dent 83:562–566PubMedCrossRef
31.
go back to reference Vigolo P, Majzoub Z, Cordioli G (2003) Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. J Prosthet Dent 89:186–192PubMedCrossRef Vigolo P, Majzoub Z, Cordioli G (2003) Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. J Prosthet Dent 89:186–192PubMedCrossRef
32.
go back to reference Vigolo P, Fonzi F et al (2004) An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent 92:470–476PubMedCrossRef Vigolo P, Fonzi F et al (2004) An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent 92:470–476PubMedCrossRef
33.
go back to reference Lee H, So JS, Hochstedler JL, Ercoli C (2008) The accuracy of implant impressions: a systematic review. J Prosthet Dent 100:285–291PubMedCrossRef Lee H, So JS, Hochstedler JL, Ercoli C (2008) The accuracy of implant impressions: a systematic review. J Prosthet Dent 100:285–291PubMedCrossRef
34.
go back to reference Akca K, Cehreli MC (2004) Accuracy of 2 impression techniques for ITI implants. Int J Oral Maxillofac Implants 19:517–523PubMed Akca K, Cehreli MC (2004) Accuracy of 2 impression techniques for ITI implants. Int J Oral Maxillofac Implants 19:517–523PubMed
35.
go back to reference Phillips KM, Nicholls J, Ma T, Rubenstein J (1994) The accuracy of three implant impression techniques: a three-dimensional analysis. Int J Oral Maxillofac Implants 9:533–540 Phillips KM, Nicholls J, Ma T, Rubenstein J (1994) The accuracy of three implant impression techniques: a three-dimensional analysis. Int J Oral Maxillofac Implants 9:533–540
36.
go back to reference Del’Acqua MA, Arioli-Filho JN, Compagnoni MA, Mollo Fde A Jr (2008) Accuracy of impression and pouring techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implants 23:226–236PubMed Del’Acqua MA, Arioli-Filho JN, Compagnoni MA, Mollo Fde A Jr (2008) Accuracy of impression and pouring techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implants 23:226–236PubMed
37.
go back to reference Humphries RM, Yaman P, Bloem TJ (1990) The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 5:331–336PubMed Humphries RM, Yaman P, Bloem TJ (1990) The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 5:331–336PubMed
38.
go back to reference De La Cruz JE, Funkenbusch PD, Ercoli C, Moss ME, Graser GN, Tallents RH (2002) Verification jig for implant-supported prostheses: a comparison of standard impressions with verification jigs made of different materials. J Prosthet Dent 88:329–336PubMedCrossRef De La Cruz JE, Funkenbusch PD, Ercoli C, Moss ME, Graser GN, Tallents RH (2002) Verification jig for implant-supported prostheses: a comparison of standard impressions with verification jigs made of different materials. J Prosthet Dent 88:329–336PubMedCrossRef
39.
go back to reference Herbst D, Nel JC, Driessen CH, Becker PJ (2000) Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 83:555–561PubMedCrossRef Herbst D, Nel JC, Driessen CH, Becker PJ (2000) Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 83:555–561PubMedCrossRef
40.
go back to reference Daoudi MF, Setchell DJ, Searson LJ (2004) An evaluation of three implant level impression techniques for single tooth implant.”. Eur J Prosthodont Restor Dent 12:9–14PubMed Daoudi MF, Setchell DJ, Searson LJ (2004) An evaluation of three implant level impression techniques for single tooth implant.”. Eur J Prosthodont Restor Dent 12:9–14PubMed
41.
go back to reference Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri A (2004) Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. Int J Oral Maxillofac Implants 19:192–198PubMed Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri A (2004) Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. Int J Oral Maxillofac Implants 19:192–198PubMed
42.
go back to reference Spector MR, Donovan TE, Nicholls JI (1990) An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 63:444–447PubMedCrossRef Spector MR, Donovan TE, Nicholls JI (1990) An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 63:444–447PubMedCrossRef
43.
go back to reference Inturregui JA, Aquilino SA, Ryther JS, Lund PS (1993) Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent 69:503–509PubMedCrossRef Inturregui JA, Aquilino SA, Ryther JS, Lund PS (1993) Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent 69:503–509PubMedCrossRef
44.
go back to reference Burawi G, Houston F, Byrne D, Claffey N (1997) A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. J Prosthet Dent 77:68–75PubMedCrossRef Burawi G, Houston F, Byrne D, Claffey N (1997) A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. J Prosthet Dent 77:68–75PubMedCrossRef
45.
go back to reference Mojon P, Oberholzer JP, Oberholzer JP, Meyer JM, Belser UC (1990) Polymerization shrinkage of index and pattern acrylic resins. J Prosthet Dent 64:684–688PubMedCrossRef Mojon P, Oberholzer JP, Oberholzer JP, Meyer JM, Belser UC (1990) Polymerization shrinkage of index and pattern acrylic resins. J Prosthet Dent 64:684–688PubMedCrossRef
46.
go back to reference Hsu CC, Millstein PL, Stein RS (1993) A comparative analysis of the accuracy of implant transfer techniques. J Prosthet Dent 69:588–593PubMedCrossRef Hsu CC, Millstein PL, Stein RS (1993) A comparative analysis of the accuracy of implant transfer techniques. J Prosthet Dent 69:588–593PubMedCrossRef
47.
go back to reference Assif D, Nissan J, Varsano I, Singer A (1999) Accuracy of implant impression splinted techniques: effect of splinting material. Int J Oral Maxillofac Implants 14:885–888PubMed Assif D, Nissan J, Varsano I, Singer A (1999) Accuracy of implant impression splinted techniques: effect of splinting material. Int J Oral Maxillofac Implants 14:885–888PubMed
48.
go back to reference Eid N (2004) An implant impression technique using a plaster splinting index combined with a silicone impression. J Prosthet Dent 92:575–577PubMedCrossRef Eid N (2004) An implant impression technique using a plaster splinting index combined with a silicone impression. J Prosthet Dent 92:575–577PubMedCrossRef
49.
go back to reference Hariharan R, Shankar C, Rajan M, Baig MR, Azhagarasan NS (2010) Evaluation of accuracy of multiple dental implant impressions using various splinting materials. Int J Oral Maxillofac Implants 25:38–44PubMed Hariharan R, Shankar C, Rajan M, Baig MR, Azhagarasan NS (2010) Evaluation of accuracy of multiple dental implant impressions using various splinting materials. Int J Oral Maxillofac Implants 25:38–44PubMed
Metadata
Title
Passive Fit in Screw Retained Multi-unit Implant Prosthesis Understanding and Achieving: A Review of the Literature
Authors
Muaiyed Mahmoud Buzayan
Norsiah Binti Yunus
Publication date
01-03-2014
Publisher
Springer India
Published in
The Journal of Indian Prosthodontic Society / Issue 1/2014
Print ISSN: 0972-4052
Electronic ISSN: 1998-4057
DOI
https://doi.org/10.1007/s13191-013-0343-x

Other articles of this Issue 1/2014

The Journal of Indian Prosthodontic Society 1/2014 Go to the issue