Skip to main content
Top
Published in: MUSCULOSKELETAL SURGERY 3/2014

01-12-2014 | Original Article

VA-LCP anterior clavicle plate: The anatomically precontoured fixation system with angular stability for clavicle shaft

Author: G. D. J. van Olden

Published in: MUSCULOSKELETAL SURGERY | Issue 3/2014

Login to get access

Abstract

Introduction

The aim of this investigation was to evaluate the introduction of the VA-LCP anterior clavicle plate in the treatment of clavicle fractures.

Material and methods

From March 2011 to March 2013, 42 clavicle fractures were treated; 40 were middle-third and 2 lateral-third, and 13/42 (31 %) patients were treated due to painful nonunion. Patient age ranged from 16 to 81 years.

Results

Complications were screw placement through the AC-joint, one superficial wound infection and one neuropraxia of the nervus radialis with dropping hand. We had some difficulties prebending both lateral to low and lateral to high but without clinical consequences. In all cases, the fracture healed with full functionality. After 1 year, 4 patients underwent a removal of the hardware.

Conclusion

The VA-LCP anterior plate showed good reliability and sufficient stability with both middle-third, lateral and nonunion fractures of the clavicle.
Literature
1.
go back to reference McKee RC, Whelan DB, Schemitsch EH, McKee MD (2012) Operative versus nonoperative care of displaced midshaft clavicular fractures: a meta-analysis of randomized clinical trials. J Bone Joint Surg Am 94:675–684PubMedCrossRef McKee RC, Whelan DB, Schemitsch EH, McKee MD (2012) Operative versus nonoperative care of displaced midshaft clavicular fractures: a meta-analysis of randomized clinical trials. J Bone Joint Surg Am 94:675–684PubMedCrossRef
2.
go back to reference Hill JM, McGuire MH, Crosby LA (1997) Closed treatment of displaced middle-third fractures of the clavicle gives poor results. J Bone Joint Surg Br 79:537–539PubMedCrossRef Hill JM, McGuire MH, Crosby LA (1997) Closed treatment of displaced middle-third fractures of the clavicle gives poor results. J Bone Joint Surg Br 79:537–539PubMedCrossRef
3.
go back to reference Matis N (1999) Effects of clavicle shortening after clavicle fracture. Unfallchirurg 275:314–315 Matis N (1999) Effects of clavicle shortening after clavicle fracture. Unfallchirurg 275:314–315
4.
go back to reference Houwert RM, Wijdicks FJG, Bisschop CS et al (2012) Plate fixation versus intramedullary fixation for displaced midshaft clavicle fractures: a systematic review. Int Orthop 36:579–585PubMedCentralPubMedCrossRef Houwert RM, Wijdicks FJG, Bisschop CS et al (2012) Plate fixation versus intramedullary fixation for displaced midshaft clavicle fractures: a systematic review. Int Orthop 36:579–585PubMedCentralPubMedCrossRef
5.
go back to reference Wijdicks FJG, Houwert RM, Dijkgraaf MGW, et al. A randomized controlled trial comparing plate fixation versus intramedullary fixation for dislocated midshaft clavicle fractures: short term results. [thesis] Wijdicks FJG, Houwert RM, Dijkgraaf MGW, et al. A randomized controlled trial comparing plate fixation versus intramedullary fixation for dislocated midshaft clavicle fractures: short term results. [thesis]
6.
go back to reference Canadian Orthopaedic Trauma Society (2007) Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multicenter, randomized clinical trial. J Bone Joint Surg Am 89:1–10 Canadian Orthopaedic Trauma Society (2007) Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multicenter, randomized clinical trial. J Bone Joint Surg Am 89:1–10
7.
go back to reference Taylor PR, Day RE, Nicholls RL et al (2011) The comminuted midshaft clavicle fracture: a biomechanical evaluation of plating methods. Clin Biomech (Bristol, Avon) 26:491–496CrossRef Taylor PR, Day RE, Nicholls RL et al (2011) The comminuted midshaft clavicle fracture: a biomechanical evaluation of plating methods. Clin Biomech (Bristol, Avon) 26:491–496CrossRef
8.
go back to reference Sinha A, Edwin J, Sreeharsha B et al (2011) A radiological study to define safe zones for drilling during plating of clavicle fractures. J Bone Joint Surg Br 93:1247–1252PubMedCrossRef Sinha A, Edwin J, Sreeharsha B et al (2011) A radiological study to define safe zones for drilling during plating of clavicle fractures. J Bone Joint Surg Br 93:1247–1252PubMedCrossRef
9.
go back to reference Formaini N, Taylor BC, Backes J, Bramwell TJ (2013) Superior versus anteroinferior plating of clavicle fractures. Orthopedics 36(7):898–904CrossRef Formaini N, Taylor BC, Backes J, Bramwell TJ (2013) Superior versus anteroinferior plating of clavicle fractures. Orthopedics 36(7):898–904CrossRef
10.
go back to reference Houwert RM, Wijdicks FJ, Steins Bisschop C et al (2012) Plate fixation versus intramedullary fixation for displaced mid-shaft clavicle fractures: a systematic review. Int Orthop 36:579–585PubMedCentralPubMedCrossRef Houwert RM, Wijdicks FJ, Steins Bisschop C et al (2012) Plate fixation versus intramedullary fixation for displaced mid-shaft clavicle fractures: a systematic review. Int Orthop 36:579–585PubMedCentralPubMedCrossRef
11.
go back to reference Lenza M, Belloti JC, Gomes Dos Santos JB, et al (2009) Surgical interventions for treating acute fractures or non-union of the middle third of the clavicle. Cochrane Database Syst Rev (4):CD007428 Lenza M, Belloti JC, Gomes Dos Santos JB, et al (2009) Surgical interventions for treating acute fractures or non-union of the middle third of the clavicle. Cochrane Database Syst Rev (4):CD007428
12.
go back to reference Virtanen KJ, Remes V, Pajarinen J et al (2012) Sling compared with plate osteosynthesis for treatment of displaced midshaft clavicular fractures. J Bone Joint Surg Am 94:1546–1553PubMedCrossRef Virtanen KJ, Remes V, Pajarinen J et al (2012) Sling compared with plate osteosynthesis for treatment of displaced midshaft clavicular fractures. J Bone Joint Surg Am 94:1546–1553PubMedCrossRef
13.
Metadata
Title
VA-LCP anterior clavicle plate: The anatomically precontoured fixation system with angular stability for clavicle shaft
Author
G. D. J. van Olden
Publication date
01-12-2014
Publisher
Springer Milan
Published in
MUSCULOSKELETAL SURGERY / Issue 3/2014
Print ISSN: 2035-5106
Electronic ISSN: 2035-5114
DOI
https://doi.org/10.1007/s12306-013-0302-z

Other articles of this Issue 3/2014

MUSCULOSKELETAL SURGERY 3/2014 Go to the issue