Skip to main content
Top
Published in: Indian Journal of Surgery 5/2023

17-01-2023 | Case Report

Access Site Complication—Successful Retrieval of Retained Radial Sheath

Authors: Rakesh Kumar Jha, Kanishk Malik, Amit Pushkarna

Published in: Indian Journal of Surgery | Issue 5/2023

Login to get access

Abstract

Endo-vascular interventions are relatively safer compared to open vascular procedures. They require specialized radio-opaque hardwares, accidental retention, or dislodgement of which may lead to serious complications. Hence, we need to be very cautious during the procedure, and whenever there is a loss, retention, or migration of hardware is suspected, it should be retrieved immediately to prevent further local or systemic complications. A 57-year-old male patient underwent left ICA stenting. During hardware removal, right radial arterial sheath got fractured and distal segment retained inside the radial artery. Emergency exploration and retrieval of retained sheath was done successfully by conventional open surgical technique. There is an increasing trend of using radial artery for arterial access, being safer, cost-effective, and favorable anatomical relations due to its superficial course, allowing easy compression and hemostasis. Nevertheless, radial artery access-site complications do occur; we have successfully managed a case of retained radial artery foreign body with successful outcome. All endovascular procedures must be performed carefully, and in case of accidental retention of hardware, immediate exploration and removal of FB are needed to prevent limb or life-threatening complications.
Literature
3.
go back to reference Fisher RG, Ferreyro R (1978) Evaluation of current technique for nonsurgical remoral of intravascular iatrogenic foreign body. Am J Rentgenol 130:541–548. [Google Scholar] Fisher RG, Ferreyro R (1978) Evaluation of current technique for nonsurgical remoral of intravascular iatrogenic foreign body. Am J Rentgenol 130:541–548. [Google Scholar]
4.
go back to reference Ozmen N, Uz O, Cingözbay BY et al (2011) Successful percutaneous retrieval of a broken intravascular ultrasound catheter tip from the renal artery. Turk Kardiyol Dern Ars 2013:505–7. [Google Scholar] Ozmen N, Uz O, Cingözbay BY et al (2011) Successful percutaneous retrieval of a broken intravascular ultrasound catheter tip from the renal artery. Turk Kardiyol Dern Ars 2013:505–7. [Google Scholar]
5.
go back to reference Kumar RR, Ranjan P (2020) Case report: iatrogenic fracture of intravenous cannula during removal with proximal migration. Int J Surg Case Rep 1(76):562–565CrossRef Kumar RR, Ranjan P (2020) Case report: iatrogenic fracture of intravenous cannula during removal with proximal migration. Int J Surg Case Rep 1(76):562–565CrossRef
Metadata
Title
Access Site Complication—Successful Retrieval of Retained Radial Sheath
Authors
Rakesh Kumar Jha
Kanishk Malik
Amit Pushkarna
Publication date
17-01-2023
Publisher
Springer India
Published in
Indian Journal of Surgery / Issue 5/2023
Print ISSN: 0972-2068
Electronic ISSN: 0973-9793
DOI
https://doi.org/10.1007/s12262-023-03680-9

Other articles of this Issue 5/2023

Indian Journal of Surgery 5/2023 Go to the issue