01-12-2019 | Endoscopic Retrograde Cholangiopancreatography

Evaluation of scattered radiation from fluoroscopy using small OSL dosimeters

Authors: Hajime Ito, Ikuo Kobayashi, Kazutoshi Watanabe, Shigehiro Ochi, Noriyuki Yanagawa

Published in: Radiological Physics and Technology | Issue 4/2019

Login to get access

Abstract

Recently, there has been a significant amount of interest in studying the importance of radiation doses to the eye lens during endoscopic retrograde cholangiopancreatography (ERCP). A study that focused on measuring the scattered radiation using an ionization chamber survey meter reported that a lead curtain was useful in reducing the scattered radiation. The over-couch X-ray tube system tends to deliver higher doses to the head and neck of the staff involved in the procedure than the under-couch X-ray tube position. In this study, a small optically stimulated luminescence (OSL) dosimeter called the nanoDot was used to evaluate and measure the amount of radiation; this dosimeter was developed by Landauer Ltd. and was specifically designed for point measurements. There are numerous studies that have reported the usefulness of personal OSL dosimeters other than the nanoDot to measure scattered radiation. Here, we evaluated the amount of scattered radiation, along with the degree of reduction achieved with the use of a protective curtain, while employing a personal OSL dosimeter and nanoDot. When the scattered radiation dose was measured using the nanoDot, the maximum recorded value without a protective curtain was 0.363 mGy and that with a protective curtain was 0.026 mGy, both at the height of 100 cm. The maximum reduction rate of scattered radiation while using a protective curtain was approximately 93% and 97% at 100 cm and 150 cm, respectively. The measured values recorded using both personal OSL dosimeters and nanoDot machine were strongly correlated.
Literature
1.
go back to reference Stewart FA, Akleyev AV, Hauer-Jensen M, Hendry JH, Kleiman NJ, Macvittie TJ, Aleman BM, Edgar AB, Mabuchi K, Muirhead CR, Shore RE, Wallace WH. ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs–threshold doses for tissue reactions in a radiation protection context. Ann ICRP. 2012;41(1–2):1–322.CrossRef Stewart FA, Akleyev AV, Hauer-Jensen M, Hendry JH, Kleiman NJ, Macvittie TJ, Aleman BM, Edgar AB, Mabuchi K, Muirhead CR, Shore RE, Wallace WH. ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs–threshold doses for tissue reactions in a radiation protection context. Ann ICRP. 2012;41(1–2):1–322.CrossRef
2.
go back to reference Matsubara K, Koshida K, Noto K, Takata T, Suzuki M, Shimono T, Yamamoto T, Matsui O. A head phantom study for intraocular dose evaluation of 64-slice multidetector CT examination in patients with suspected cranial trauma. Eur J Radiol. 2011;79(2):283–7.CrossRef Matsubara K, Koshida K, Noto K, Takata T, Suzuki M, Shimono T, Yamamoto T, Matsui O. A head phantom study for intraocular dose evaluation of 64-slice multidetector CT examination in patients with suspected cranial trauma. Eur J Radiol. 2011;79(2):283–7.CrossRef
3.
go back to reference Take T, Sato K, Kiuchi K, Nakazawa Y. Creation of a crystalline lens radiation exposure defense cover and the effect of radiation exposure decrease on neuro-interventions. Jpns Soc Radiol Technol. 2007;63:1246–52.CrossRef Take T, Sato K, Kiuchi K, Nakazawa Y. Creation of a crystalline lens radiation exposure defense cover and the effect of radiation exposure decrease on neuro-interventions. Jpns Soc Radiol Technol. 2007;63:1246–52.CrossRef
4.
go back to reference O’Connor U, Gallagher A, Malone L, O’Reilly G. Occupational radiation dose to eyes from endoscopic retrograde cholangiopancreatography procedures in light of the revised eye lens dose limit from the International Commission on Radiological Protection. Br J Radiol. 2013;86:20120289.CrossRef O’Connor U, Gallagher A, Malone L, O’Reilly G. Occupational radiation dose to eyes from endoscopic retrograde cholangiopancreatography procedures in light of the revised eye lens dose limit from the International Commission on Radiological Protection. Br J Radiol. 2013;86:20120289.CrossRef
5.
go back to reference Yoshida R, et al. Evaluation of usefulness of X-ray tube protector for X-ray fluoroscopy in ERCP etc. J Jpn Assoc Rural Med. 2014;63–2:127–31.CrossRef Yoshida R, et al. Evaluation of usefulness of X-ray tube protector for X-ray fluoroscopy in ERCP etc. J Jpn Assoc Rural Med. 2014;63–2:127–31.CrossRef
6.
go back to reference Jursinic PA. Characterization of optically stimulated luminescent dosimeters, OSLs, for clinical dosimetric measurements. Med Phys. 2007;34:4594–604.CrossRef Jursinic PA. Characterization of optically stimulated luminescent dosimeters, OSLs, for clinical dosimetric measurements. Med Phys. 2007;34:4594–604.CrossRef
7.
go back to reference Kerns JR, Kry SF, Sahoo N, Followill DS, Ibbott GS. Angular dependence of the nanoDot OSL dosimeter. Med Phys. 2011;38:3955–62.CrossRef Kerns JR, Kry SF, Sahoo N, Followill DS, Ibbott GS. Angular dependence of the nanoDot OSL dosimeter. Med Phys. 2011;38:3955–62.CrossRef
8.
go back to reference Hayashi H, et al. High accuracy measurements by consecutive readings of OSL dosimeter. Med Imaging Inf Sci. 2014;31:228–34. Hayashi H, et al. High accuracy measurements by consecutive readings of OSL dosimeter. Med Imaging Inf Sci. 2014;31:228–34.
9.
go back to reference Landauer, Inc. microStar User Manual, 1–66. Glenwood: Landauer Inc.; 2009. Landauer, Inc. microStar User Manual, 1–66. Glenwood: Landauer Inc.; 2009.
10.
go back to reference Chida K. Evaluation and protection of surgeon exposure in interventional radiology. Jpn Soc Radiol Technol. 2008;50:1009–144.CrossRef Chida K. Evaluation and protection of surgeon exposure in interventional radiology. Jpn Soc Radiol Technol. 2008;50:1009–144.CrossRef
11.
go back to reference Kusama T. Anata to Kanja notameno Housyasenbougo Q&A Radiation protection for you and the patient Q&A. Iryo kagakusya. 1996;1:98–9. Kusama T. Anata to Kanja notameno Housyasenbougo Q&A Radiation protection for you and the patient Q&A. Iryo kagakusya. 1996;1:98–9.
12.
go back to reference Tomita H, Morozumi K. Measurement of scatter radiation on MDCT equipment using an OSL dosimeter. Jpn Soc Radiol Technol. 2004;60:1550–4.CrossRef Tomita H, Morozumi K. Measurement of scatter radiation on MDCT equipment using an OSL dosimeter. Jpn Soc Radiol Technol. 2004;60:1550–4.CrossRef
Metadata
Title
Evaluation of scattered radiation from fluoroscopy using small OSL dosimeters
Authors
Hajime Ito
Ikuo Kobayashi
Kazutoshi Watanabe
Shigehiro Ochi
Noriyuki Yanagawa
Publication date
01-12-2019
Publisher
Springer Singapore
Published in
Radiological Physics and Technology / Issue 4/2019
Print ISSN: 1865-0333
Electronic ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-019-00536-4

Other articles of this Issue 4/2019

Radiological Physics and Technology 4/2019 Go to the issue