Skip to main content
Top
Published in: Radiological Physics and Technology 3/2018

01-09-2018

Evaluation of local look diffusion tensor imaging for magnetic resonance tractography of the periprostatic neurovascular bundle

Authors: Wataru Jomoto, Masao Tanooka, Tsukasa Wakayama, Takahiro Minamoto, Toru Suzuki, Reiichi Ishikura, Shingo Yamamoto, Noriko Kotoura

Published in: Radiological Physics and Technology | Issue 3/2018

Login to get access

Abstract

The purpose of this study was to compare diffusion tensor imaging using the local look technique and sensitivity encoding for tractography of the periprostatic neurovascular bundle. We compared the surrounding tissues of the prostate in eight healthy volunteers. The results of tractography in terms of the numbers of fibers and the fractional anisotropy map were evaluated. Distortion was evaluated using the dice similarity coefficient between isotropic diffusion images created from diffusion tensor images and T2-weighted images. The number of lines in tractography was significantly greater in diffusion tensor imaging using the local look technique (p < 0.001). Although there was no difference in image distortion of the prostate between methods, an artifact appeared in the center of the diffusion tensor image using sensitivity encoding. In conclusion, diffusion tensor imaging using the local look technique was superior to that using sensitivity encoding for tractography of the periprostatic neurovascular bundle.
Literature
1.
go back to reference Binder J, Kramer W. Robotically assisted laparoscopic radical prostatectomy. BJU Int. 2001;87:408–10.CrossRefPubMed Binder J, Kramer W. Robotically assisted laparoscopic radical prostatectomy. BJU Int. 2001;87:408–10.CrossRefPubMed
2.
go back to reference Park BJ, Sung DJ, Kim MJ, Cho SB, Kim YH, Chung KB, Kang SH, Cheon J. The incidence and anatomy of accessory pudendal arteries as depicted on multidetector-row CT angiography: clinical implications of preoperative evaluation for laparoscopic and robotassisted radical prostatectomy. Korean J Radiol. 2009;10(6):587–95.CrossRefPubMedPubMedCentral Park BJ, Sung DJ, Kim MJ, Cho SB, Kim YH, Chung KB, Kang SH, Cheon J. The incidence and anatomy of accessory pudendal arteries as depicted on multidetector-row CT angiography: clinical implications of preoperative evaluation for laparoscopic and robotassisted radical prostatectomy. Korean J Radiol. 2009;10(6):587–95.CrossRefPubMedPubMedCentral
3.
go back to reference Whang SY, Sung DJ, Lee SA, Park BJ, Kim MJ, Cho SB, Kim YH, Cheon J. Preoperative detection and localization of accessory pudendal artery with contrast-enhanced MR angiography. Radiology. 2012;262(3):903–11.CrossRefPubMed Whang SY, Sung DJ, Lee SA, Park BJ, Kim MJ, Cho SB, Kim YH, Cheon J. Preoperative detection and localization of accessory pudendal artery with contrast-enhanced MR angiography. Radiology. 2012;262(3):903–11.CrossRefPubMed
4.
go back to reference Kawasaki K, Matsumoto M, Kase M, Nagano O, Aoyagi K, Kageyama T. Quantification of the radiation dose to the pyramidal tract using tractography in treatment planning for stereotactic radiosurgery. Radiol Phys Technol. 2017;10(4):507–14.CrossRefPubMed Kawasaki K, Matsumoto M, Kase M, Nagano O, Aoyagi K, Kageyama T. Quantification of the radiation dose to the pyramidal tract using tractography in treatment planning for stereotactic radiosurgery. Radiol Phys Technol. 2017;10(4):507–14.CrossRefPubMed
5.
go back to reference Panebianco V, Barchetti F, Sciarra A, Marcantonio A, Zini C, Salciccia S, Collettini F, Gentile V, Hamm B, Catalano C. In vivo 3D neuroanatomical evaluation of periprostatic nerve plexus with 3T-MR diffusion tensor imaging. Eur J Radiol. 2013;82(10):1677–82.CrossRefPubMed Panebianco V, Barchetti F, Sciarra A, Marcantonio A, Zini C, Salciccia S, Collettini F, Gentile V, Hamm B, Catalano C. In vivo 3D neuroanatomical evaluation of periprostatic nerve plexus with 3T-MR diffusion tensor imaging. Eur J Radiol. 2013;82(10):1677–82.CrossRefPubMed
6.
go back to reference Buecker A, Adam G, Neuerburg JM, Glowinski A, van Vaals JJ, Guenther RW. MR-guided biopsy using a T2-weighted single-shot zoom imaging sequence (local look technique). J Magn Reson Imaging. 1998;8(4):955–9.CrossRefPubMed Buecker A, Adam G, Neuerburg JM, Glowinski A, van Vaals JJ, Guenther RW. MR-guided biopsy using a T2-weighted single-shot zoom imaging sequence (local look technique). J Magn Reson Imaging. 1998;8(4):955–9.CrossRefPubMed
7.
go back to reference Jin N, Deng J, Zhang L, Zhang Z, Lu G, Omary RA, Larson AC. Targeted single-shot methods for diffusion-weighted imaging in the kidneys. J Magn Reson Imaging. 2011;33(6):1517–25.CrossRefPubMedPubMedCentral Jin N, Deng J, Zhang L, Zhang Z, Lu G, Omary RA, Larson AC. Targeted single-shot methods for diffusion-weighted imaging in the kidneys. J Magn Reson Imaging. 2011;33(6):1517–25.CrossRefPubMedPubMedCentral
8.
go back to reference Sabater S, Pastor-Juan Mdel R, Berenguer R, Andres I, Sevillano M, Lozano-Setien E, Jimenez-Jimenez E, Rovirosa A, Sanchez-Prieto R, Arenas M. Analysing the integration of MR images acquired in a non-radiotherapy treatment position into the radiotherapy workflow using deformable and rigid registration. Radiother Oncol. 2016;119(1):179–84.CrossRefPubMed Sabater S, Pastor-Juan Mdel R, Berenguer R, Andres I, Sevillano M, Lozano-Setien E, Jimenez-Jimenez E, Rovirosa A, Sanchez-Prieto R, Arenas M. Analysing the integration of MR images acquired in a non-radiotherapy treatment position into the radiotherapy workflow using deformable and rigid registration. Radiother Oncol. 2016;119(1):179–84.CrossRefPubMed
9.
go back to reference Zijdenbos AP, Dawant BM, Margolin RA, Palmer AC. Morphometric analysis of white matter lesions in MR images: method and validation. IEEE Trans Med Imaging. 1994;13(4):716–24.CrossRefPubMed Zijdenbos AP, Dawant BM, Margolin RA, Palmer AC. Morphometric analysis of white matter lesions in MR images: method and validation. IEEE Trans Med Imaging. 1994;13(4):716–24.CrossRefPubMed
10.
go back to reference Muro I, Kamiya A, Honda M, Horie T. Examination of imaging parameter influence on image distortion in EPI. Jpn J Radiol Technol. 2007;63(1):91–96.CrossRef Muro I, Kamiya A, Honda M, Horie T. Examination of imaging parameter influence on image distortion in EPI. Jpn J Radiol Technol. 2007;63(1):91–96.CrossRef
11.
go back to reference Ream JM, Glielmi C, Lazar M, Campbell N, Pfeuffer J, Schneider R, Rosenkrantz AB. Zoomed echo-planar diffusion tensor imaging for MR tractography of the prostate gland neurovascular bundle without an endorectal coil: a feasibility study. Abdom. Radiol. 2016;41(5):919–25.CrossRef Ream JM, Glielmi C, Lazar M, Campbell N, Pfeuffer J, Schneider R, Rosenkrantz AB. Zoomed echo-planar diffusion tensor imaging for MR tractography of the prostate gland neurovascular bundle without an endorectal coil: a feasibility study. Abdom. Radiol. 2016;41(5):919–25.CrossRef
12.
go back to reference Muro I, Kaneko A, Honda M, Horie T. Study of aliasing ERROR with SENSE in body diffusion image using single-shot EPI at 3T. Jpn J Radiol Technol. 2008;64(12):1497–1503.CrossRef Muro I, Kaneko A, Honda M, Horie T. Study of aliasing ERROR with SENSE in body diffusion image using single-shot EPI at 3T. Jpn J Radiol Technol. 2008;64(12):1497–1503.CrossRef
13.
go back to reference Walsh PC, Donker PJ. Impotence following radical prostatectomy: insight into etiology and prevention. J Urol. 1982;128:492–7.CrossRefPubMed Walsh PC, Donker PJ. Impotence following radical prostatectomy: insight into etiology and prevention. J Urol. 1982;128:492–7.CrossRefPubMed
14.
go back to reference Sievert K-D, Hennenlotter J, Laible I, Amend B, Schilling D, Anastasiadis A, Kuehs U, Nagele U, Stenzl A. The periprostatic autonomic nerves—bundle or layer? Eur Urol. 2008;54:1109–17.CrossRefPubMed Sievert K-D, Hennenlotter J, Laible I, Amend B, Schilling D, Anastasiadis A, Kuehs U, Nagele U, Stenzl A. The periprostatic autonomic nerves—bundle or layer? Eur Urol. 2008;54:1109–17.CrossRefPubMed
15.
go back to reference Eichelberg C, Erbersdobler A, Michl U, Schlomm T, Salomon G, Graefen M, Huland H. Nerve distribution along the prostatic capsule. Eur Urol. 2007;51:105–11.CrossRefPubMed Eichelberg C, Erbersdobler A, Michl U, Schlomm T, Salomon G, Graefen M, Huland H. Nerve distribution along the prostatic capsule. Eur Urol. 2007;51:105–11.CrossRefPubMed
16.
go back to reference Lunacek A, Schwentner C, Fritsch H, Bartsch G, Strasser H. Anatomical radical retropubic prostatectomy: ‘curtain dissection’ of the neurovascular bundle. BJU Int. 2005;95:1226–31.CrossRefPubMed Lunacek A, Schwentner C, Fritsch H, Bartsch G, Strasser H. Anatomical radical retropubic prostatectomy: ‘curtain dissection’ of the neurovascular bundle. BJU Int. 2005;95:1226–31.CrossRefPubMed
17.
go back to reference Weinreb JC, Barentsz JO, Choyke PL, Cornud F, Haider MA, Macura KJ, Margolis D, Schnall MD, Shtern F, Tempany CM, Thoeny HC, Verma S. PI-RADS prostate imaging—reporting and data system: 2015, version 2. Eur Urol. 2016;69(1):16–40.CrossRefPubMed Weinreb JC, Barentsz JO, Choyke PL, Cornud F, Haider MA, Macura KJ, Margolis D, Schnall MD, Shtern F, Tempany CM, Thoeny HC, Verma S. PI-RADS prostate imaging—reporting and data system: 2015, version 2. Eur Urol. 2016;69(1):16–40.CrossRefPubMed
Metadata
Title
Evaluation of local look diffusion tensor imaging for magnetic resonance tractography of the periprostatic neurovascular bundle
Authors
Wataru Jomoto
Masao Tanooka
Tsukasa Wakayama
Takahiro Minamoto
Toru Suzuki
Reiichi Ishikura
Shingo Yamamoto
Noriko Kotoura
Publication date
01-09-2018
Publisher
Springer Singapore
Published in
Radiological Physics and Technology / Issue 3/2018
Print ISSN: 1865-0333
Electronic ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-018-0470-5

Other articles of this Issue 3/2018

Radiological Physics and Technology 3/2018 Go to the issue