Improved wedge method for the measurement of sub-millimeter slice thicknesses in magnetic resonance imaging

Authors: Tsutomu Kanazawa, Masaki Ohkubo, Tatsuya Kondo, Takayuki Miyazawa, Shoichi Inagawa

Published in: Radiological Physics and Technology | Issue 4/2017

Login to get access

Abstract

The standard method for measuring the slice thickness of magnetic resonance images uses the inclined surface of a wedge (wedge method); it is sensitive to small increases in noise because of the differentiation of the edge response function (ERF) required. The purpose of this study was to improve the wedge method by fitting a curve to the ERF. The curve-fit function was obtained by convolving an ideal ERF (a ramp function) with a Gaussian function to represent ERF blurring. Measurements of 5- and 3-mm slice thicknesses were performed on a 3T scanner using the conventional wedge method, the improved wedge method, and another standard method using an inclined slab (slab method). Subsequently, 0.5- and 0.25-mm slice thicknesses from multiple slices acquired using a three-dimensional sequence were measured using the improved wedge method. When measuring 5-mm slices, the differences in measurements obtained using the improved wedge method and the conventional slab and wedge methods were very small: <0.6% of the 5-mm slice thickness. The difference was ≤1.7% for 3-mm slices. For 0.5- and 0.25-mm slices, the mean values obtained using the improved wedge method were 0.543 ± 0.007 mm and 0.247 ± 0.015 mm, with a 1.2 and 5.9% coefficient of variation across slices, respectively. The improved wedge method is valid and potentially applicable to the measurement of sub-millimeter slice thicknesses.
Literature
1.
go back to reference Fischbach F, Müller M, Bruhn H. High-resolution depiction of the cranial nerves in the posterior fossa (N III-N XII) with 2D fast spin echo and 3D gradient echo sequences at 3.0 T. Clin Imaging. 2009;33:169–74.CrossRefPubMed Fischbach F, Müller M, Bruhn H. High-resolution depiction of the cranial nerves in the posterior fossa (N III-N XII) with 2D fast spin echo and 3D gradient echo sequences at 3.0 T. Clin Imaging. 2009;33:169–74.CrossRefPubMed
2.
go back to reference Simon JH, Li D, Traboulsee A, Coyle PK, Arnold DL, Barkhof F, Frank JA, Grossman R, Paty DW, Radue EW, Wolinsky JS. Standardized MR imaging protocol for multiple sclerosis: consortium of MS centers consensus guidelines. Am J Neuroradiol. 2006;27:455–61.PubMed Simon JH, Li D, Traboulsee A, Coyle PK, Arnold DL, Barkhof F, Frank JA, Grossman R, Paty DW, Radue EW, Wolinsky JS. Standardized MR imaging protocol for multiple sclerosis: consortium of MS centers consensus guidelines. Am J Neuroradiol. 2006;27:455–61.PubMed
3.
go back to reference Sasaki M, Inoue T, Tohyama K, Oikawa H, Ehara S, Ogawa A. High-field MRI of the central nervous system: current approaches to clinical and microscopic imaging. Magn Reson Med Sci. 2003;2:133–9.CrossRefPubMed Sasaki M, Inoue T, Tohyama K, Oikawa H, Ehara S, Ogawa A. High-field MRI of the central nervous system: current approaches to clinical and microscopic imaging. Magn Reson Med Sci. 2003;2:133–9.CrossRefPubMed
4.
go back to reference Yue Y, Jin Y, Yang B, Yuan H, Li J, Wang Z. Retrospective case series of the imaging findings of facial nerve hemangioma. Eur Arch Otorhinolaryngol. 2015;272:2497–503.CrossRefPubMed Yue Y, Jin Y, Yang B, Yuan H, Li J, Wang Z. Retrospective case series of the imaging findings of facial nerve hemangioma. Eur Arch Otorhinolaryngol. 2015;272:2497–503.CrossRefPubMed
5.
go back to reference Tuleasca C, Carron R, Resseguier N, Donnet A, Roussel P, Gaudart J, Levivier M, Régis J. Decreased probability of initial pain cessation in classic trigeminal neuralgia treated with gamma knife surgery in case of previous microvascular decompression: a prospective series of 45 patients With >1 Year of follow-up. Neurosurgery. 2015;77:87–94.CrossRefPubMed Tuleasca C, Carron R, Resseguier N, Donnet A, Roussel P, Gaudart J, Levivier M, Régis J. Decreased probability of initial pain cessation in classic trigeminal neuralgia treated with gamma knife surgery in case of previous microvascular decompression: a prospective series of 45 patients With >1 Year of follow-up. Neurosurgery. 2015;77:87–94.CrossRefPubMed
6.
go back to reference Docampo J, Gonzalez N, Muñoz A, Bravo F, Sarroca D, Morales C. Neurovascular study of the trigeminal nerve at 3 T MRI. Neuroradiol J. 2015;28:28–35.CrossRefPubMedPubMedCentral Docampo J, Gonzalez N, Muñoz A, Bravo F, Sarroca D, Morales C. Neurovascular study of the trigeminal nerve at 3 T MRI. Neuroradiol J. 2015;28:28–35.CrossRefPubMedPubMedCentral
7.
go back to reference Association National Electrical Manufacturers. NEMA standards publications MS 5-2010, Determination of slice thickness in diagnostic magnetic resonance imaging. Rosslyn: National Electrical Manufacturers Association; 2010. Association National Electrical Manufacturers. NEMA standards publications MS 5-2010, Determination of slice thickness in diagnostic magnetic resonance imaging. Rosslyn: National Electrical Manufacturers Association; 2010.
8.
go back to reference Och JG, Clarke GD, Sobol WT, Rosen CW, Mun SK. Acceptance testing of magnetic resonance imaging systems: report of AAPM nuclear magnetic resonance Task Group No. 6. Med Phys. 1992;19:217–29.CrossRefPubMed Och JG, Clarke GD, Sobol WT, Rosen CW, Mun SK. Acceptance testing of magnetic resonance imaging systems: report of AAPM nuclear magnetic resonance Task Group No. 6. Med Phys. 1992;19:217–29.CrossRefPubMed
9.
go back to reference Price RR, Axel L, Morgan T, Newman R, Perman W, Schneiders N, Selikson M, Wood M, Thomas SR. Quality assurance methods and phantoms for magnetic resonance imaging: report of AAPM nuclear magnetic resonance Task Group No. 1. Med Phys. 1990;17:287–95.CrossRefPubMed Price RR, Axel L, Morgan T, Newman R, Perman W, Schneiders N, Selikson M, Wood M, Thomas SR. Quality assurance methods and phantoms for magnetic resonance imaging: report of AAPM nuclear magnetic resonance Task Group No. 1. Med Phys. 1990;17:287–95.CrossRefPubMed
10.
go back to reference Selikson M, Fearon T. Averaging error in NMR slice profile measurements. Magn Reson Med. 1988;7:280–4.CrossRefPubMed Selikson M, Fearon T. Averaging error in NMR slice profile measurements. Magn Reson Med. 1988;7:280–4.CrossRefPubMed
11.
go back to reference Lerski RA, de Certaines JD. Performance assessment and quality control in MRI by Eurospin test objects and protocols. Magn Reson Imaging. 1993;11:817–33.CrossRefPubMed Lerski RA, de Certaines JD. Performance assessment and quality control in MRI by Eurospin test objects and protocols. Magn Reson Imaging. 1993;11:817–33.CrossRefPubMed
12.
go back to reference Firbank MJ, Harrison RM, Williams ED, Coulthard A. Quality assurance for MRI: practical experience. Br J Radiol. 2000;73:376–83.CrossRefPubMed Firbank MJ, Harrison RM, Williams ED, Coulthard A. Quality assurance for MRI: practical experience. Br J Radiol. 2000;73:376–83.CrossRefPubMed
13.
go back to reference Lerski RA. An evaluation using computer simulation of two methods of slice profile determination in MRI. Phys Med Biol. 1989;34(12):1931–7.CrossRef Lerski RA. An evaluation using computer simulation of two methods of slice profile determination in MRI. Phys Med Biol. 1989;34(12):1931–7.CrossRef
14.
go back to reference Ohkubo M, Wada S, Kunii M, Matsumoto T, Nishizawa K. Imaging of small spherical structures in CT: simulation study using measured point spread function. Med Biol Eng Comput. 2008;46:273–82.CrossRefPubMed Ohkubo M, Wada S, Kunii M, Matsumoto T, Nishizawa K. Imaging of small spherical structures in CT: simulation study using measured point spread function. Med Biol Eng Comput. 2008;46:273–82.CrossRefPubMed
15.
go back to reference Yoshida R, Machida Y, Ogura T, Tamura H, Hikichi T, Mori I. Slice profile measurement using a crossed thin-ramps method in three-dimensional magnetic resonance imaging. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2012;68:1456–66 (in Japanese).CrossRefPubMed Yoshida R, Machida Y, Ogura T, Tamura H, Hikichi T, Mori I. Slice profile measurement using a crossed thin-ramps method in three-dimensional magnetic resonance imaging. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2012;68:1456–66 (in Japanese).CrossRefPubMed
Metadata
Title
Improved wedge method for the measurement of sub-millimeter slice thicknesses in magnetic resonance imaging
Authors
Tsutomu Kanazawa
Masaki Ohkubo
Tatsuya Kondo
Takayuki Miyazawa
Shoichi Inagawa
Publication date
01-12-2017
Publisher
Springer Singapore
Published in
Radiological Physics and Technology / Issue 4/2017
Print ISSN: 1865-0333
Electronic ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-017-0417-2

Other articles of this Issue 4/2017

Radiological Physics and Technology 4/2017 Go to the issue