Optimal injection method for long-range computed tomography angiography

Authors: Aogu Yamaguchi, Tsukasa Sasaki

Published in: Radiological Physics and Technology | Issue 3/2017

Login to get access

Abstract

We aimed to obtain high-stable computed tomography (CT) values for CT angiography (CTA). We verified the optimal use of the new protocol for long-range scanning using a contrast material flow phantom (Ichikawa, CT imaging theory. Igaku syoin Publishing, Tokyo, 8; Awai et al., Am J Roentgenol 186(2):379–385, 1) to obtain high-stable CT values (Fig. 2). We have developed a novel contrast injection method called the stable line imaging protocol (SLIP). This method involved a gradual reduction in the rate of administration of the contrast medium, which was accompanied by simultaneous administration of saline to compensate for the resultant decrease in the rate of administration. A saline flush was further added after the contrast medium injection. The rate of administration of the saline flush was the same as that of the initial contrast medium. We injected a contrast medium from the injector into the flow phantom. The time-enhancement curve (TEC) data were obtained five times by changing the injection method, and the average CT values were determined. The maximum simulation of the aortic peak enhancement of TEC was defined as pTEC. The time required to keep the CT value more than 80% of the pTEC was defined as the time period of contrast enhancement (p80). The pTEC of a single injection was 295.7 ± 5.3 HU, while that of SLIP was 296.5 ± 2.3 HU; the two values did not differ significantly. The p80 of a single injection was 19.1 ± 0.2 s, while that of SLIP was 23.2 ± 0.4 s; p80 of SLIP was 18% longer than that of the single injection.
Literature
1.
go back to reference Awai K, Hatcho A, Nakayama Y, Kusunoki S, Liu D, Hatemura M, Yamashita Y, et al. Simulation of aortic peak enhancement on MDCT using a contrast material flow phantom: feasibility study. Am J Roentgenol. 2006;186(2):379–85.CrossRef Awai K, Hatcho A, Nakayama Y, Kusunoki S, Liu D, Hatemura M, Yamashita Y, et al. Simulation of aortic peak enhancement on MDCT using a contrast material flow phantom: feasibility study. Am J Roentgenol. 2006;186(2):379–85.CrossRef
2.
go back to reference Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches 1. Radiology. 2010;256(1):32–61.CrossRefPubMed Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches 1. Radiology. 2010;256(1):32–61.CrossRefPubMed
3.
go back to reference Behrendt FF, Bruners P, Keil S, Plumhans C, Mahnken AH, Das M, Mühlenbruch G, et al. Effect of different saline chaser volumes and flow rates on intravascular contrast enhancement in CT using a circulation phantom. Eur J Radiol. 2010;73(3):688–93.CrossRefPubMed Behrendt FF, Bruners P, Keil S, Plumhans C, Mahnken AH, Das M, Mühlenbruch G, et al. Effect of different saline chaser volumes and flow rates on intravascular contrast enhancement in CT using a circulation phantom. Eur J Radiol. 2010;73(3):688–93.CrossRefPubMed
4.
go back to reference Behrendt FF, Jost G, Pietsch H, Keil S, Mottaghy FM, Günther RW, Mahnken AH. Computed tomography angiography: the effect of different chaser flow rates, volumes, and fluids on contrast enhancement. Invest Radiol. 2011;46(4):271–6.CrossRefPubMed Behrendt FF, Jost G, Pietsch H, Keil S, Mottaghy FM, Günther RW, Mahnken AH. Computed tomography angiography: the effect of different chaser flow rates, volumes, and fluids on contrast enhancement. Invest Radiol. 2011;46(4):271–6.CrossRefPubMed
5.
go back to reference Cameron JR, Skofronick JG, Grant RM. Physics of the body. 2nd ed. Madison: Medical Physics; 1999. Cameron JR, Skofronick JG, Grant RM. Physics of the body. 2nd ed. Madison: Medical Physics; 1999.
6.
go back to reference Fleischmann D. CT angiography: injection and acquisition technique. Radiol Clin N Am. 2010;48(2):237–47.CrossRefPubMed Fleischmann D. CT angiography: injection and acquisition technique. Radiol Clin N Am. 2010;48(2):237–47.CrossRefPubMed
7.
go back to reference Hudson DM. Top shelf human anatomy & physiology. J Weston Walch Publishing; 2006. Hudson DM. Top shelf human anatomy & physiology. J Weston Walch Publishing; 2006.
8.
go back to reference Ichikawa T. CT imaging theory. Tokyo: Igaku syoin Publishing; 2004. Ichikawa T. CT imaging theory. Tokyo: Igaku syoin Publishing; 2004.
9.
go back to reference Kim T, Murakami T, Takahashi S, Tsuda K, Tomoda K, Narumi Y, Nakamura H, et al. Effects of injection rates of contrast material on arterial phase hepatic CT. AJR Am J Roentgenol. 1998;171(2):429–32.CrossRefPubMed Kim T, Murakami T, Takahashi S, Tsuda K, Tomoda K, Narumi Y, Nakamura H, et al. Effects of injection rates of contrast material on arterial phase hepatic CT. AJR Am J Roentgenol. 1998;171(2):429–32.CrossRefPubMed
10.
go back to reference Lu JG, Lv B, Chen XB, Tang X, Jiang SL, Dai RP. What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography? Eur J Radiol. 2010;75(2):159–65.CrossRefPubMed Lu JG, Lv B, Chen XB, Tang X, Jiang SL, Dai RP. What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography? Eur J Radiol. 2010;75(2):159–65.CrossRefPubMed
11.
go back to reference Marin D, Nelson RC, Guerrisi A, Barnhart H, Schindera ST, Passariello R, Catalano C. 64-section multidetector CT of the upper abdomen: optimization of a saline chaser injection protocol for improved vascular and parenchymal contrast enhancement. Eur Radiol. 2011;21(9):1938–47.CrossRefPubMed Marin D, Nelson RC, Guerrisi A, Barnhart H, Schindera ST, Passariello R, Catalano C. 64-section multidetector CT of the upper abdomen: optimization of a saline chaser injection protocol for improved vascular and parenchymal contrast enhancement. Eur Radiol. 2011;21(9):1938–47.CrossRefPubMed
12.
go back to reference Takeyama N, Kuroki K, Hayashi T, Sai S, Okabe N, Kinebuchi Y, Gokan T, et al. Cerebral CT angiography using a small volume of concentrated contrast material with a test injection method: optimal scan delay for quantitative and qualitative performance. Br J Radiol. 2012;85(1017):e748.CrossRefPubMedPubMedCentral Takeyama N, Kuroki K, Hayashi T, Sai S, Okabe N, Kinebuchi Y, Gokan T, et al. Cerebral CT angiography using a small volume of concentrated contrast material with a test injection method: optimal scan delay for quantitative and qualitative performance. Br J Radiol. 2012;85(1017):e748.CrossRefPubMedPubMedCentral
13.
go back to reference Tatsugami F, Matsuki M, Inada Y, Nakai G, Tanikake M, Yoshikawa S, Narabayashi I. Usefulness of saline pushing in reduction of contrast material dose in abdominal CT: evaluation of time–density curve for the aorta, portal vein and liver. Br J Radiol. 2007;80:231–4.CrossRefPubMed Tatsugami F, Matsuki M, Inada Y, Nakai G, Tanikake M, Yoshikawa S, Narabayashi I. Usefulness of saline pushing in reduction of contrast material dose in abdominal CT: evaluation of time–density curve for the aorta, portal vein and liver. Br J Radiol. 2007;80:231–4.CrossRefPubMed
14.
go back to reference Tomizawa N, Suzuki F, Akahane M, Torigoe R, Kiryu S, Ohtomo K. Effect of saline flush on enhancement of proximal and distal segments using 320-row coronary CT angiography. Eur J Radiol. 2013;82(8):1255–9.CrossRefPubMed Tomizawa N, Suzuki F, Akahane M, Torigoe R, Kiryu S, Ohtomo K. Effect of saline flush on enhancement of proximal and distal segments using 320-row coronary CT angiography. Eur J Radiol. 2013;82(8):1255–9.CrossRefPubMed
15.
go back to reference Yamaguchi I, Kidoya E, Suzuki M, Kimura H. Optimizing scan timing of hepatic arterial phase by physiologic pharmacokinetic analysis in bolus-tracking technique by multi-detector row computed tomography. Radiol Phys Technol. 2011;4(1):43–52.CrossRefPubMed Yamaguchi I, Kidoya E, Suzuki M, Kimura H. Optimizing scan timing of hepatic arterial phase by physiologic pharmacokinetic analysis in bolus-tracking technique by multi-detector row computed tomography. Radiol Phys Technol. 2011;4(1):43–52.CrossRefPubMed
Metadata
Title
Optimal injection method for long-range computed tomography angiography
Authors
Aogu Yamaguchi
Tsukasa Sasaki
Publication date
01-09-2017
Publisher
Springer Singapore
Published in
Radiological Physics and Technology / Issue 3/2017
Print ISSN: 1865-0333
Electronic ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-017-0402-9

Other articles of this Issue 3/2017

Radiological Physics and Technology 3/2017 Go to the issue