Skip to main content
Top
Published in: Annals of Nuclear Medicine 4/2015

01-05-2015 | Original Article

A myocardial perfusion imaging system using a multifocal collimator for detecting coronary artery disease: validation with invasive coronary angiography

Authors: Yutaka Ogino, Yoriko Horiguchi, Tomohiro Ueda, Tomofumi Shiomori, Masahiko Kanna, Tomoko Kawaminami, Naoki Iinuma, Yuta Sudo, Yukiko Morita

Published in: Annals of Nuclear Medicine | Issue 4/2015

Login to get access

Abstract

Objective

Myocardial perfusion imaging (MPI) systems using a multifocal collimator can reduce scan time substantially compared with conventional MPI systems. In this study, we evaluated the diagnostic accuracy of multifocal collimator SPECT/CT in coronary artery disease (CAD) detection by comparing it with coronary artery angiography (CAG).

Methods

We retrospectively analyzed 50 consecutive patients who had undergone CAG and stress 201Tl MPI multifocal collimator SPECT/CT within a 3-month period. A summed difference score (SDS) was calculated for each vascular territory from the MPI images. On CAG, a stenotic coronary artery was defined as one with luminal narrowing of ≥75 % with quantitative coronary angiography software.

Results

We analyzed the diagnostic accuracy of coronary artery stenosis detection using the definition that a coronary artery territory was ischemic when the SDS per vessel was ≥2. We generated receiver operating characteristic (ROC) curves to evaluate the usefulness of SDS per vascular territory to find coronary artery stenoses. The area under the ROC curve was 0.86 and cut-off value was 2. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy to detect stenoses were 85, 83, 66, 94 and 84 %, respectively.

Conclusions

We confirmed the high accuracy of imaging with multifocal collimator SPECT/CT for detection of angiographically significant CAD.
Literature
1.
go back to reference Rajaram R, Bhattacharya M, Ding X, Malmin R, Rempel TD, Vija AH, et al. Tomographic performance characteristics of the IQ SPECT system. IEEE nuclear science symposium conference record. 2011;2451–6. Rajaram R, Bhattacharya M, Ding X, Malmin R, Rempel TD, Vija AH, et al. Tomographic performance characteristics of the IQ SPECT system. IEEE nuclear science symposium conference record. 2011;2451–6.
2.
go back to reference Vija AH, Malmin R, Yahil A, Zeintl J, Bhattacharya M, Rempel TD, et al. A method for improving the efficiency of myocardial perfusion imaging using conventional SPECT and SPECT/CT imaging systems. IEEE nuclear science symposium and medical imaging conference record. 2010; 3433–7. Vija AH, Malmin R, Yahil A, Zeintl J, Bhattacharya M, Rempel TD, et al. A method for improving the efficiency of myocardial perfusion imaging using conventional SPECT and SPECT/CT imaging systems. IEEE nuclear science symposium and medical imaging conference record. 2010; 3433–7.
3.
go back to reference Caobelli F, Pizzocaro C, Paghera B, Guerra UP. Evaluation of patients with coronary artery disease. IQ-SPECT protocol in myocardial perfusion imaging: preliminary results. Nuklearmedizin. 2013;52:178–85.CrossRefPubMed Caobelli F, Pizzocaro C, Paghera B, Guerra UP. Evaluation of patients with coronary artery disease. IQ-SPECT protocol in myocardial perfusion imaging: preliminary results. Nuklearmedizin. 2013;52:178–85.CrossRefPubMed
4.
go back to reference Horiguchi Y, Ueda T, Shiomori T, Kanna M, Matsushita H, Kawaminami T, et al. Validation of a short-scan-time imaging protocol for thallium-201 myocardial SPECT with a multifocal collimator. Ann Nucl Med. 2014;28:707–15.CrossRefPubMed Horiguchi Y, Ueda T, Shiomori T, Kanna M, Matsushita H, Kawaminami T, et al. Validation of a short-scan-time imaging protocol for thallium-201 myocardial SPECT with a multifocal collimator. Ann Nucl Med. 2014;28:707–15.CrossRefPubMed
5.
go back to reference Nakata T, Watanabe S, Matsuo H, Hosokawa R, Kasai T. Risk management guidelines for the routine clinical use of stress myocardial perfusion imaging. Shinzoukakuigaku. 2008;9:6–10 (in Japanese). Nakata T, Watanabe S, Matsuo H, Hosokawa R, Kasai T. Risk management guidelines for the routine clinical use of stress myocardial perfusion imaging. Shinzoukakuigaku. 2008;9:6–10 (in Japanese).
6.
go back to reference Cerqueria MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation. 2002;105:539–42.CrossRef Cerqueria MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation. 2002;105:539–42.CrossRef
7.
go back to reference Cohen J. Weighted kappa: nominal scale agreement with provision for scaled disagreement or partial credit. Psychol Bull. 1968;70:213–20.CrossRefPubMed Cohen J. Weighted kappa: nominal scale agreement with provision for scaled disagreement or partial credit. Psychol Bull. 1968;70:213–20.CrossRefPubMed
8.
go back to reference Ozaki Y, Keane D, Herrman JP, et al. Coronary arteriography for quantitative analysis: an experimental and clinical comparison of cinefilm and video recordings. Am Heart J. 1995;129:471–5.CrossRefPubMed Ozaki Y, Keane D, Herrman JP, et al. Coronary arteriography for quantitative analysis: an experimental and clinical comparison of cinefilm and video recordings. Am Heart J. 1995;129:471–5.CrossRefPubMed
9.
go back to reference Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159–74.CrossRefPubMed Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159–74.CrossRefPubMed
10.
go back to reference Tamaki N, Morita K. SPECT in cardiology. Q J Nucl Med. 2005;49:193–203. Tamaki N, Morita K. SPECT in cardiology. Q J Nucl Med. 2005;49:193–203.
11.
go back to reference Cuocolo A, Acampa W, Imbriaco M, De Luca N, Iovino GL, Salvatore M. The many ways to myocardial perfusion imaging. Q J Nucl Med Mol Imaging. 2005;49:4–18.PubMed Cuocolo A, Acampa W, Imbriaco M, De Luca N, Iovino GL, Salvatore M. The many ways to myocardial perfusion imaging. Q J Nucl Med Mol Imaging. 2005;49:4–18.PubMed
12.
go back to reference Nakajima K, Matsuo S, Kawano M, Matsumoto N, Hashimoto J, Yoshinaga K, et al. The validity of multi-center common normal database for identifying myocardial ischemia: Japanese Society of Nuclear Medicine working group database. Ann Nucl Med. 2010;24:99–105.CrossRefPubMed Nakajima K, Matsuo S, Kawano M, Matsumoto N, Hashimoto J, Yoshinaga K, et al. The validity of multi-center common normal database for identifying myocardial ischemia: Japanese Society of Nuclear Medicine working group database. Ann Nucl Med. 2010;24:99–105.CrossRefPubMed
13.
go back to reference Allman KC, Berry J, Sucharski LA, Stafford KA, Petry NA, Wysor W, et al. Determination of extent and location of coronary artery disease in patients without prior myocardial infarction by thallium-201 tomography with pharmacologic stress. J Nucl Med. 1992;33:2067–73.PubMed Allman KC, Berry J, Sucharski LA, Stafford KA, Petry NA, Wysor W, et al. Determination of extent and location of coronary artery disease in patients without prior myocardial infarction by thallium-201 tomography with pharmacologic stress. J Nucl Med. 1992;33:2067–73.PubMed
14.
go back to reference Förster S, Rieber J, Ubleis C, Weiss M, Bartenstein P, Cumming P, et al. Tc-99 m sestamibi single photon emission computed tomography for guiding percutaneous coronary intervention in patients with multivessel disease: a comparison with quantitative coronary angiography and fraction flow reserve. Int J Cardiovasc Imaging. 2010;26:203–13.CrossRefPubMed Förster S, Rieber J, Ubleis C, Weiss M, Bartenstein P, Cumming P, et al. Tc-99 m sestamibi single photon emission computed tomography for guiding percutaneous coronary intervention in patients with multivessel disease: a comparison with quantitative coronary angiography and fraction flow reserve. Int J Cardiovasc Imaging. 2010;26:203–13.CrossRefPubMed
15.
go back to reference Tonino PA, De Bruyne B, Pijls NH, Siebert U, Ikeno F, van’t Veer M, et al. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention. N Engl J Med 2009;15:213–224. Tonino PA, De Bruyne B, Pijls NH, Siebert U, Ikeno F, van’t Veer M, et al. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention. N Engl J Med 2009;15:213–224.
16.
go back to reference Fiechter M, Ghadri JR, Kuest SM, Pazhenkottil AP, Wolfrum M, Nkoulou RN, et al. Nuclear myocardial perfusion imaging with a novel cadmium–zinc–telluride detector SPECT/CT device: first validation versus invasive coronary angiography. Eur J Nucl Med Mol Imaging. 2011;38:2025–30.CrossRefPubMed Fiechter M, Ghadri JR, Kuest SM, Pazhenkottil AP, Wolfrum M, Nkoulou RN, et al. Nuclear myocardial perfusion imaging with a novel cadmium–zinc–telluride detector SPECT/CT device: first validation versus invasive coronary angiography. Eur J Nucl Med Mol Imaging. 2011;38:2025–30.CrossRefPubMed
17.
go back to reference Nakazato R, Berman DS, Hayes SW, Fish M, Padgett R, Xu Y, et al. Myocardial perfusion imaging with a solid-state camera: simulation of a very low dose imaging protocol. J Nucl Med. 2013;54:373–9.CrossRefPubMedCentralPubMed Nakazato R, Berman DS, Hayes SW, Fish M, Padgett R, Xu Y, et al. Myocardial perfusion imaging with a solid-state camera: simulation of a very low dose imaging protocol. J Nucl Med. 2013;54:373–9.CrossRefPubMedCentralPubMed
Metadata
Title
A myocardial perfusion imaging system using a multifocal collimator for detecting coronary artery disease: validation with invasive coronary angiography
Authors
Yutaka Ogino
Yoriko Horiguchi
Tomohiro Ueda
Tomofumi Shiomori
Masahiko Kanna
Tomoko Kawaminami
Naoki Iinuma
Yuta Sudo
Yukiko Morita
Publication date
01-05-2015
Publisher
Springer Japan
Published in
Annals of Nuclear Medicine / Issue 4/2015
Print ISSN: 0914-7187
Electronic ISSN: 1864-6433
DOI
https://doi.org/10.1007/s12149-015-0955-9

Other articles of this Issue 4/2015

Annals of Nuclear Medicine 4/2015 Go to the issue