Abstract

Aim

Computer-aided diagnosis (CAD) software for bone scintigrams have recently been introduced as a clinical quality assurance tool. The purpose of this study was to compare the diagnostic accuracy of two CAD systems, one based on a European and one on a Japanese training database, in a group of bone scans from Japanese patients.

Method

The two CAD software are trained to interpret bone scans using training databases consisting of bone scans with the desired interpretation, metastatic disease or not. One software was trained using 795 bone scans from European patients and the other with 904 bone scans from Japanese patients. The two CAD softwares were evaluated using the same group of 257 Japanese patients, who underwent bone scintigraphy because of suspected metastases of malignant tumors in 2009. The final diagnostic results made by clinicians were used as gold standard.

Results

The Japanese CAD software showed a higher specificity and accuracy compared to the European CAD software [81 vs. 57 % (p < 0.05) and 82 vs. 61 % (p < 0.05), respectively]. The sensitivity was 90 % for the Japanese CAD software and 83 % for the European CAD software (n.s).

Conclusion

The CAD software trained with a Japanese database showed significantly higher performance than the corresponding CAD software trained with a European database for the analysis of bone scans from Japanese patients. These results could at least partly be caused by the physical differences between Japanese and European patients resulting in less influence of attenuation in Japanese patients and possible different judgement of count intensities of hot spots.
Literature
1.
go back to reference Maffioli L, Florimonte L, Pagani L, Butti I, Roca IN. Current role of bone scan with phosphonates in the follow-up of breast cancer. Eur J Nucl Med Mol Imaging. 2004;31(Suppl 1):S143–8.PubMedCrossRef Maffioli L, Florimonte L, Pagani L, Butti I, Roca IN. Current role of bone scan with phosphonates in the follow-up of breast cancer. Eur J Nucl Med Mol Imaging. 2004;31(Suppl 1):S143–8.PubMedCrossRef
2.
go back to reference Coleman R, Heidenreich A, Bell R. Managing metastatic bone disease: three case studies. Semin Oncol. 2004;31:83–6.PubMedCrossRef Coleman R, Heidenreich A, Bell R. Managing metastatic bone disease: three case studies. Semin Oncol. 2004;31:83–6.PubMedCrossRef
3.
go back to reference Coleman RE. Metastatic bone disease: clinical features, pathophysiology and treatment strategies. Cancer Treat Rev. 2001;27:165–76.PubMedCrossRef Coleman RE. Metastatic bone disease: clinical features, pathophysiology and treatment strategies. Cancer Treat Rev. 2001;27:165–76.PubMedCrossRef
4.
go back to reference Doi K. Computer-aided diagnosis in medical imaging: historical review, current status and future potential. Comput Med Imaging Graph. 2007;31:198–211.PubMedCrossRef Doi K. Computer-aided diagnosis in medical imaging: historical review, current status and future potential. Comput Med Imaging Graph. 2007;31:198–211.PubMedCrossRef
5.
go back to reference Gromet M. Comparison of computer-aided detection to double reading of screening mammograms: review of 231,221 mammograms. AJR. 2008;190:854–9.PubMedCrossRef Gromet M. Comparison of computer-aided detection to double reading of screening mammograms: review of 231,221 mammograms. AJR. 2008;190:854–9.PubMedCrossRef
6.
go back to reference Goldin JG, Brown MS, Petkovska I. Computer-aided diagnosis in lung nodule assessment. J Thorac Imaging. 2008;23:97–104.PubMedCrossRef Goldin JG, Brown MS, Petkovska I. Computer-aided diagnosis in lung nodule assessment. J Thorac Imaging. 2008;23:97–104.PubMedCrossRef
7.
go back to reference Kawamoto K, Houlihan CA, Balas EA, Lobach DF. Improving clinical practice using clinical decision support systems: a systemic review of trials to identify features critical to success. BMJ. 2005;330:765–8.PubMedCrossRef Kawamoto K, Houlihan CA, Balas EA, Lobach DF. Improving clinical practice using clinical decision support systems: a systemic review of trials to identify features critical to success. BMJ. 2005;330:765–8.PubMedCrossRef
8.
go back to reference Freer TW, Ulissey MJ. Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center. Radiology. 2001;220:781–6.PubMedCrossRef Freer TW, Ulissey MJ. Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center. Radiology. 2001;220:781–6.PubMedCrossRef
9.
go back to reference Lindahl D, Lanke J, Lundin A, Palmer J, Edenbrandt L. Improved classifications of myocardial bull’s-eye scintigrams with computer-based decision support systems. J Nucl Med. 1999;40:96–101.PubMed Lindahl D, Lanke J, Lundin A, Palmer J, Edenbrandt L. Improved classifications of myocardial bull’s-eye scintigrams with computer-based decision support systems. J Nucl Med. 1999;40:96–101.PubMed
10.
go back to reference Sadik M, Hamadeh I, Nordblom P, Suurkula M, Hoglund P, Ohlsson M, et al. Computer-assisted interpretation of planar whole-body bone scans. J Nucl Med. 2008;49(12):1958–65.PubMedCrossRef Sadik M, Hamadeh I, Nordblom P, Suurkula M, Hoglund P, Ohlsson M, et al. Computer-assisted interpretation of planar whole-body bone scans. J Nucl Med. 2008;49(12):1958–65.PubMedCrossRef
11.
go back to reference Sadik M, Suurkula M, Hoglund P, Jarund A, Edenbrandt L. Quality of planar whole-body bone scan interpretations: a nationwide survey. Eur J Nucl Med Mol Imaging. 2008;35:1464–72.PubMedCrossRef Sadik M, Suurkula M, Hoglund P, Jarund A, Edenbrandt L. Quality of planar whole-body bone scan interpretations: a nationwide survey. Eur J Nucl Med Mol Imaging. 2008;35:1464–72.PubMedCrossRef
12.
go back to reference Sadik M, Suurkula M, Höglund P, Järund A, Edenbrandt L. Improved classifications of planar whole-body bonescans using a computer-assisted diagnosis system: a multicenter, multiple-reader, multiple-case study. J Nucl Med. 2009;50(3):368–75.PubMedCrossRef Sadik M, Suurkula M, Höglund P, Järund A, Edenbrandt L. Improved classifications of planar whole-body bonescans using a computer-assisted diagnosis system: a multicenter, multiple-reader, multiple-case study. J Nucl Med. 2009;50(3):368–75.PubMedCrossRef
13.
go back to reference Sadik M, Jakobsson D, Olofsson F, Ohlsson M, Suurkula M, Edenbrandt L. A new computer-based decision-support system for the interpretation of bone scans. Nucl Med Commun. 2006;27:417–23.PubMedCrossRef Sadik M, Jakobsson D, Olofsson F, Ohlsson M, Suurkula M, Edenbrandt L. A new computer-based decision-support system for the interpretation of bone scans. Nucl Med Commun. 2006;27:417–23.PubMedCrossRef
14.
go back to reference Yin T-K, Chiu N-T. A computer-aided diagnosis for locating abnormalities in bone scintigraphy by a fuzzy system with a three-step minimization approach. IEEE Trans Med Imag. 2004;23:639–54.CrossRef Yin T-K, Chiu N-T. A computer-aided diagnosis for locating abnormalities in bone scintigraphy by a fuzzy system with a three-step minimization approach. IEEE Trans Med Imag. 2004;23:639–54.CrossRef
15.
go back to reference Nakajima K, Okuda K, Kawano M, Matsuo S, Slomka P, Germano G, et al. The importance of population-specific normal database for quantification of myocardial ischemia: comparison between Japanese 360 and 180-degree databases and a US database. J Nucl Cardiol. 2009;16:422–30.PubMedCrossRef Nakajima K, Okuda K, Kawano M, Matsuo S, Slomka P, Germano G, et al. The importance of population-specific normal database for quantification of myocardial ischemia: comparison between Japanese 360 and 180-degree databases and a US database. J Nucl Cardiol. 2009;16:422–30.PubMedCrossRef
Metadata
Title
Computer-aided diagnosis system for bone scintigrams from Japanese patients: importance of training database
Authors
Hiroyuki Horikoshi
Akihiro Kikuchi
Masahisa Onoguchi
Karl Sjöstrand
Lars Edenbrandt
Publication date
01-10-2012
Publisher
Springer Japan
Published in
Annals of Nuclear Medicine / Issue 8/2012
Print ISSN: 0914-7187
Electronic ISSN: 1864-6433
DOI
https://doi.org/10.1007/s12149-012-0620-5

Other articles of this Issue 8/2012

Annals of Nuclear Medicine 8/2012 Go to the issue