Skip to main content
Top
Published in: Head and Neck Pathology 2/2018

01-06-2018 | Original Paper

Importance of FNA Technique for Decreasing Non-diagnostic Rates in Thyroid Nodules

Authors: Amarbir S. Gill, Richard Amdur, Arjun S. Joshi

Published in: Head and Neck Pathology | Issue 2/2018

Login to get access

Abstract

To identify potential interventions that may lower the high non-diagnostic rates associated with ultrasound guided (US) fine needle aspiration (FNA) biopsy of the thyroid nodule. A case series of 164 thyroid nodule US-guided FNA was identified retrospectively. The following variables were analyzed in regards to diagnostic and non-diagnostic sampling: patient age, gender, size of nodule, biopsy technique (capillary vs. aspiration), needle gauge (23 vs. 25), and physician experience. The FNA diagnosis, and final pathology, when applicable, was recorded for each sample using the Bethesda criteria. Data was analyzed using the Fisher’s exact test or the chi square test. After multivariate logistic regression, capillary action was independently associated with lower non-diagnostic rates (p = 0.01), while increasing patient age was associated with higher non-diagnostic rates (p = 0.018). Physician experience (p = 0.014) was not independently associated with lower non-diagnostic rates. Nodules that were “cystic >50%” were significantly more likely to yield a non-diagnostic result (p < 0.0001). After taking into account confounding variables, including physician experience, our data reveals a statistically significant decrease in non-diagnostic rates with the use of capillary action vs. aspiration technique in US-guided FNA. A major focus in healthcare today is providing cost-effective and minimally invasive care to the patient. In the setting of a rising incidence of thyroid disease, we believe our study demonstrates the need for a prospective analysis of the relationship between technique and non-diagnostic rates.
Literature
1.
go back to reference Cooper DS, Doherty GM, Haugen BR, et al. Revised American Thyroid Association management guidelines for patients with thyroid nodules and differentiated thyroid cancer. Thyroid. 2009;19:1167–214.CrossRefPubMed Cooper DS, Doherty GM, Haugen BR, et al. Revised American Thyroid Association management guidelines for patients with thyroid nodules and differentiated thyroid cancer. Thyroid. 2009;19:1167–214.CrossRefPubMed
2.
go back to reference Gharib H. Fine-needle aspiration biopsy of thyroid nodules: advantages, limitations, and effect. Mayo Clin Proc. 1994;69:44–9.CrossRefPubMed Gharib H. Fine-needle aspiration biopsy of thyroid nodules: advantages, limitations, and effect. Mayo Clin Proc. 1994;69:44–9.CrossRefPubMed
3.
go back to reference Baloch ZW, LiVolsi VA. Fine-needle aspiration of thyroid nodules: past, present, and future. Endocr Pract. 2004;10:234–41.CrossRefPubMed Baloch ZW, LiVolsi VA. Fine-needle aspiration of thyroid nodules: past, present, and future. Endocr Pract. 2004;10:234–41.CrossRefPubMed
5.
go back to reference Robitschek J, Straub M, Wirtz E, Klem C, Sniezek J. Diagnostic efficacy of surgeon-performed ultrasound-guided fine needle aspiration: a randomized controlled trial. Otolaryngol Head Neck Surg. 2010;142:306–9.CrossRefPubMed Robitschek J, Straub M, Wirtz E, Klem C, Sniezek J. Diagnostic efficacy of surgeon-performed ultrasound-guided fine needle aspiration: a randomized controlled trial. Otolaryngol Head Neck Surg. 2010;142:306–9.CrossRefPubMed
6.
go back to reference Carmeci C, Jeffrey RB, McDougall IR, Nowels KW, Weigel RJ. Ultrasound-guided fine-needle aspiration biopsy of thyroid masses. Thyroid. 1998;8:283–9.CrossRefPubMed Carmeci C, Jeffrey RB, McDougall IR, Nowels KW, Weigel RJ. Ultrasound-guided fine-needle aspiration biopsy of thyroid masses. Thyroid. 1998;8:283–9.CrossRefPubMed
7.
go back to reference Cesur M, Corapcioglu D, Bulut S, et al. Comparison of palpation-guided fine-needle aspiration biopsy to ultrasound-guided fine-needle aspiration biopsy in the evaluation of thyroid nodules. Thyroid. 2006;16:555–61.CrossRefPubMed Cesur M, Corapcioglu D, Bulut S, et al. Comparison of palpation-guided fine-needle aspiration biopsy to ultrasound-guided fine-needle aspiration biopsy in the evaluation of thyroid nodules. Thyroid. 2006;16:555–61.CrossRefPubMed
8.
go back to reference Bongiovanni M, Spitale A, Faquin WC, Mazzucchelli L, Baloch ZW. The Bethesda system for reporting thyroid cytopathology: a meta-analysis. Acta Cytol. 2012;56:333–9.CrossRefPubMed Bongiovanni M, Spitale A, Faquin WC, Mazzucchelli L, Baloch ZW. The Bethesda system for reporting thyroid cytopathology: a meta-analysis. Acta Cytol. 2012;56:333–9.CrossRefPubMed
9.
go back to reference Williams BA, Bullock MJ, Trites JR, Taylor SM, Hart RD. Rates of thyroid malignancy by FNA diagnostic category. J Otolaryngol Head Neck Surg. 2013;42:61.CrossRefPubMedPubMedCentral Williams BA, Bullock MJ, Trites JR, Taylor SM, Hart RD. Rates of thyroid malignancy by FNA diagnostic category. J Otolaryngol Head Neck Surg. 2013;42:61.CrossRefPubMedPubMedCentral
10.
go back to reference Cibas ES, Ali SZ. The Bethesda system for reporting thyroid cytopathology. Thyroid. 2009;19:1159–65.CrossRefPubMed Cibas ES, Ali SZ. The Bethesda system for reporting thyroid cytopathology. Thyroid. 2009;19:1159–65.CrossRefPubMed
11.
go back to reference Naïm C, Karam R, Eddé D. Ultrasound-guided fine-needle aspiration biopsy of the thyroid: methods to decrease the rate of unsatisfactory biopsies in the absence of an on-site pathologist. Can Assoc Radiol J. 2013;64:220–5.CrossRefPubMed Naïm C, Karam R, Eddé D. Ultrasound-guided fine-needle aspiration biopsy of the thyroid: methods to decrease the rate of unsatisfactory biopsies in the absence of an on-site pathologist. Can Assoc Radiol J. 2013;64:220–5.CrossRefPubMed
12.
go back to reference İnci MF, Özkan F, Yüksel M, Şalk, Şahin M. The effects of sonographic and demographic features and needle size on obtaining adequate cytological material in sonography-guided fine-needle aspiration biopsy of thyroid nodules. Endocrine. 2013;43:424–9.CrossRefPubMed İnci MF, Özkan F, Yüksel M, Şalk, Şahin M. The effects of sonographic and demographic features and needle size on obtaining adequate cytological material in sonography-guided fine-needle aspiration biopsy of thyroid nodules. Endocrine. 2013;43:424–9.CrossRefPubMed
13.
go back to reference Degirmenci B, Haktanir A, Albayrak R, et al. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material. Clin Radiol. 2007;62:798–803.CrossRefPubMed Degirmenci B, Haktanir A, Albayrak R, et al. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material. Clin Radiol. 2007;62:798–803.CrossRefPubMed
14.
go back to reference Brennan PA, Mackenzie N, Oeppen RS, Kulamarva G, Thomas GJ, Spedding AV. Prospective randomized clinical trial of the effect of needle size on pain, sample adequacy and accuracy in head and neck fine-needle aspiration cytology. Head Neck. 2007;29:919–22.CrossRefPubMed Brennan PA, Mackenzie N, Oeppen RS, Kulamarva G, Thomas GJ, Spedding AV. Prospective randomized clinical trial of the effect of needle size on pain, sample adequacy and accuracy in head and neck fine-needle aspiration cytology. Head Neck. 2007;29:919–22.CrossRefPubMed
15.
go back to reference Bhakti AM, Brewer B, Robinson-Smith T, Nikiforov Y, Steward DL. Adequacy of surgeon-performed ultrasound-guided thyroid fine needle aspiration biopsy. Otolaryngol Head Neck Surg. 2008;139(1):27–31.CrossRef Bhakti AM, Brewer B, Robinson-Smith T, Nikiforov Y, Steward DL. Adequacy of surgeon-performed ultrasound-guided thyroid fine needle aspiration biopsy. Otolaryngol Head Neck Surg. 2008;139(1):27–31.CrossRef
16.
go back to reference Cibas ES, Alexander EK, Benson CB, et al. Indications for thyroid FNA and pre-FNA requirements: a synopsis of the National Cancer Institute Thyroid Fine-Needle Aspiration State of the Science Conference. Diagn Cytopathol. 2008;36:390–9.CrossRefPubMed Cibas ES, Alexander EK, Benson CB, et al. Indications for thyroid FNA and pre-FNA requirements: a synopsis of the National Cancer Institute Thyroid Fine-Needle Aspiration State of the Science Conference. Diagn Cytopathol. 2008;36:390–9.CrossRefPubMed
17.
go back to reference Wong LQ, Baloch ZW. Analysis of the bethesda system for reporting thyroid cytopathology and similar precursor thyroid cytopathology reporting schemes. Adv Anat Pathol. 2012;19:313–9.CrossRefPubMed Wong LQ, Baloch ZW. Analysis of the bethesda system for reporting thyroid cytopathology and similar precursor thyroid cytopathology reporting schemes. Adv Anat Pathol. 2012;19:313–9.CrossRefPubMed
18.
go back to reference Moon HJ, Kwak JY, Kim EK, Kim MJ. Ultrasonographic characteristics predictive of nondiagnostic results for fine-needle aspiration biopsies of thyroid nodules. Ultrasound Med Biol. 2011;37:549–55.CrossRefPubMed Moon HJ, Kwak JY, Kim EK, Kim MJ. Ultrasonographic characteristics predictive of nondiagnostic results for fine-needle aspiration biopsies of thyroid nodules. Ultrasound Med Biol. 2011;37:549–55.CrossRefPubMed
19.
go back to reference Tublin ME, Martin JA, Rollin LJ, Pealer K, Kurs-Lasky M, Ohori NP. Ultrasound-guided fine-needle aspiration versus fine-needle capillary sampling biopsy of thyroid nodules: does technique matter? J Ultrasound Med. 2007;26:1697–701.CrossRefPubMed Tublin ME, Martin JA, Rollin LJ, Pealer K, Kurs-Lasky M, Ohori NP. Ultrasound-guided fine-needle aspiration versus fine-needle capillary sampling biopsy of thyroid nodules: does technique matter? J Ultrasound Med. 2007;26:1697–701.CrossRefPubMed
20.
go back to reference Schoedel KE, Tublin ME, Pealer K, Ohori NP. Ultrasound-guided biopsy of the thyroid: a comparison of technique with respect to diagnostic accuracy. Diagn Cytopathol. 2008;36:787–9.CrossRefPubMed Schoedel KE, Tublin ME, Pealer K, Ohori NP. Ultrasound-guided biopsy of the thyroid: a comparison of technique with respect to diagnostic accuracy. Diagn Cytopathol. 2008;36:787–9.CrossRefPubMed
21.
go back to reference Tauro LF, Lobo GJ, Fernandes H, et al. A comparative study on fine needle aspiration cytology versus fine needle capillary cytology in thyroid nodules. Oman Med J. 2012;27:151–6.CrossRefPubMedPubMedCentral Tauro LF, Lobo GJ, Fernandes H, et al. A comparative study on fine needle aspiration cytology versus fine needle capillary cytology in thyroid nodules. Oman Med J. 2012;27:151–6.CrossRefPubMedPubMedCentral
22.
go back to reference de Carvalho GA, Paz-Filho G, Cavalcanti TC, Graf H. Adequacy and diagnostic accuracy of aspiration versus capillary fine needle thyroid biopsies. Endocr Pathol. 2009;20:204–8.CrossRefPubMed de Carvalho GA, Paz-Filho G, Cavalcanti TC, Graf H. Adequacy and diagnostic accuracy of aspiration versus capillary fine needle thyroid biopsies. Endocr Pathol. 2009;20:204–8.CrossRefPubMed
23.
go back to reference Dey P, Ray R. Comparison of fine needle sampling by capillary action and fine needle aspiration. Cytopathology. 1993;4:299–303.CrossRefPubMed Dey P, Ray R. Comparison of fine needle sampling by capillary action and fine needle aspiration. Cytopathology. 1993;4:299–303.CrossRefPubMed
24.
go back to reference Zhou JQ, Zhang JW, Zhan WW, et al. Comparison of fine-needle aspiration and fine-needle capillary sampling of thyroid nodules: a prospective study with emphasis on the influence of nodule size. Cancer Cytopathol. 2014;122:266–73.CrossRefPubMed Zhou JQ, Zhang JW, Zhan WW, et al. Comparison of fine-needle aspiration and fine-needle capillary sampling of thyroid nodules: a prospective study with emphasis on the influence of nodule size. Cancer Cytopathol. 2014;122:266–73.CrossRefPubMed
25.
go back to reference Gümüş M, Cay N, Algin O, et al. Comparison of 21 and 27 gauge needles for determining sample adequacy in the aspiration biopsy of thyroid nodules. Diagn Interv Radiol. 2012;18:102–5.PubMed Gümüş M, Cay N, Algin O, et al. Comparison of 21 and 27 gauge needles for determining sample adequacy in the aspiration biopsy of thyroid nodules. Diagn Interv Radiol. 2012;18:102–5.PubMed
26.
go back to reference Tangpricha V, Chen BJ, Swan NC, Sweeney AT, de las Morenas A, Safer JD. Twenty-one-gauge needles provide more cellular samples than twenty-five-gauge needles in fine-needle aspiration biopsy of the thyroid but may not provide increased diagnostic accuracy. Thyroid. 2001;11:973–6.CrossRefPubMed Tangpricha V, Chen BJ, Swan NC, Sweeney AT, de las Morenas A, Safer JD. Twenty-one-gauge needles provide more cellular samples than twenty-five-gauge needles in fine-needle aspiration biopsy of the thyroid but may not provide increased diagnostic accuracy. Thyroid. 2001;11:973–6.CrossRefPubMed
Metadata
Title
Importance of FNA Technique for Decreasing Non-diagnostic Rates in Thyroid Nodules
Authors
Amarbir S. Gill
Richard Amdur
Arjun S. Joshi
Publication date
01-06-2018
Publisher
Springer US
Published in
Head and Neck Pathology / Issue 2/2018
Electronic ISSN: 1936-0568
DOI
https://doi.org/10.1007/s12105-017-0844-8

Other articles of this Issue 2/2018

Head and Neck Pathology 2/2018 Go to the issue