Skip to main content
Top
Published in: Indian Journal of Thoracic and Cardiovascular Surgery 3/2018

01-12-2018 | Review Article

Saphenous vein: advances

Authors: Ki-Bong Kim, Ho Young Hwang, Domingos Savio Ramos de Souza, David Paul Taggart

Published in: Indian Journal of Thoracic and Cardiovascular Surgery | Special Issue 3/2018

Login to get access

Abstract

Although the saphenous vein (SV) is a widely used conduit for coronary artery bypass graft surgery (CABG), lower long-term graft patency rates and worse clinical outcomes have been reported after CABG performed with SV grafts compared with CABG performed with internal thoracic artery (ITA) grafts. Of various efforts to overcome the limitations of SV that are resulting from structural and functional differences from arterial conduit, recent improvement in harvesting techniques including no-touch technique, surgical strategy of using the SV as part of a composite graft over an aortocoronary bypass graft, and external stenting of the SV will be discussed in this topic.
Literature
2.
go back to reference Barboriak JJ, Pintar K, Korns ME. Atherosclerosis in aortocoronary vein grafts. Lancet. 1974;304:621–4.CrossRef Barboriak JJ, Pintar K, Korns ME. Atherosclerosis in aortocoronary vein grafts. Lancet. 1974;304:621–4.CrossRef
3.
go back to reference Campeau L, Enjalbert M, Lespérance J, Vaislic C, Grondin CM, Bourassa MG. Atherosclerosis and late closure of aortocoronary saphenous vein grafts: sequential angiographic studies at 2 weeks, 1 year, 5 to 7 years, and 10 to 12 years after surgery. Circulation. 1983;68:II1–7.PubMed Campeau L, Enjalbert M, Lespérance J, Vaislic C, Grondin CM, Bourassa MG. Atherosclerosis and late closure of aortocoronary saphenous vein grafts: sequential angiographic studies at 2 weeks, 1 year, 5 to 7 years, and 10 to 12 years after surgery. Circulation. 1983;68:II1–7.PubMed
4.
go back to reference Loop FD, Lytle BW, Cosgrove DM, et al. Influence of the internal-mammary-artery graft on 10-year survival and other cardiac events. New Engl J Med. 1986;314:1–6.CrossRefPubMed Loop FD, Lytle BW, Cosgrove DM, et al. Influence of the internal-mammary-artery graft on 10-year survival and other cardiac events. New Engl J Med. 1986;314:1–6.CrossRefPubMed
5.
go back to reference Cameron A, Davis KB, Green G, Schaff HV. Coronary bypass surgery with internal-thoracic-artery grafts-effects on survival over a 15-year period. N Engl J Med. 1996;334:216–9.CrossRefPubMed Cameron A, Davis KB, Green G, Schaff HV. Coronary bypass surgery with internal-thoracic-artery grafts-effects on survival over a 15-year period. N Engl J Med. 1996;334:216–9.CrossRefPubMed
6.
go back to reference Roubos N, Rosenfeldt FL, Richards SM, Conyers RA, Davis BB. Improved preservation of saphenous vein grafts by the use of glyceryl trinitrate-verapamil solution during harvesting. Circulation. 1995;92:II-31–6.CrossRef Roubos N, Rosenfeldt FL, Richards SM, Conyers RA, Davis BB. Improved preservation of saphenous vein grafts by the use of glyceryl trinitrate-verapamil solution during harvesting. Circulation. 1995;92:II-31–6.CrossRef
7.
go back to reference Ratliff NB, Myles JL. Rapidly progressive atherosclerosis in aortocoronary saphenous vein grafts. Possible immune-mediated disease. Arch Pathol Lab Med. 1989;113:772–6.PubMed Ratliff NB, Myles JL. Rapidly progressive atherosclerosis in aortocoronary saphenous vein grafts. Possible immune-mediated disease. Arch Pathol Lab Med. 1989;113:772–6.PubMed
8.
go back to reference Souza D. A new no-touch preparation technique. Technical notes. Scand J Thorac Cardiovasc Surg. 1996;30:41–4.CrossRefPubMed Souza D. A new no-touch preparation technique. Technical notes. Scand J Thorac Cardiovasc Surg. 1996;30:41–4.CrossRefPubMed
9.
go back to reference Wan S, Shukla N, Angelini GD, Yim AP, Johnson JL, Jeremy JY. Nitric oxide-donating aspirin (NCX 4016) inhibits neointimal thickening in a pig model of saphenous vein-carotid artery interposition grafting: a comparison with aspirin and morpholinosydnonimine (SIN-1). J Thorac Cardiovasc Surg. 2007;134:1033–9.CrossRefPubMed Wan S, Shukla N, Angelini GD, Yim AP, Johnson JL, Jeremy JY. Nitric oxide-donating aspirin (NCX 4016) inhibits neointimal thickening in a pig model of saphenous vein-carotid artery interposition grafting: a comparison with aspirin and morpholinosydnonimine (SIN-1). J Thorac Cardiovasc Surg. 2007;134:1033–9.CrossRefPubMed
10.
go back to reference Alexander JH, Hafley G, Harrington RA, et al. Efficacy and safety of edifoligide, an E2F transcription factor decoy, for prevention of vein graft failure following coronary artery bypass graft surgery: PREVENT IV: a randomized controlled trial. JAMA. 2005;294:2446–54.CrossRefPubMed Alexander JH, Hafley G, Harrington RA, et al. Efficacy and safety of edifoligide, an E2F transcription factor decoy, for prevention of vein graft failure following coronary artery bypass graft surgery: PREVENT IV: a randomized controlled trial. JAMA. 2005;294:2446–54.CrossRefPubMed
11.
go back to reference Taggart DP, Ben Gal Y, Lees B, et al. A randomized trial of external stenting for saphenous vein grafts in coronary artery bypass grafting. Ann Thorac Surg. 2015;99:2039–45.CrossRefPubMed Taggart DP, Ben Gal Y, Lees B, et al. A randomized trial of external stenting for saphenous vein grafts in coronary artery bypass grafting. Ann Thorac Surg. 2015;99:2039–45.CrossRefPubMed
12.
go back to reference Dashwood MR, Tsui JC. ‘No-touch’ saphenous vein harvesting improves graft performance in patients undergoing coronary artery bypass surgery: a journey from bedside to bench. Vascul Pharmacol. 2013;58:240–50.CrossRefPubMed Dashwood MR, Tsui JC. ‘No-touch’ saphenous vein harvesting improves graft performance in patients undergoing coronary artery bypass surgery: a journey from bedside to bench. Vascul Pharmacol. 2013;58:240–50.CrossRefPubMed
13.
go back to reference Tsui JC, Souza DS, Filbey D, Bomfim V, Dashwood MR. Preserved endothelial integrity and nitric oxide synthase in saphenous vein grafts harvested by a 'no-touch' technique. Br J Surg. 2001;88:1209–15.CrossRefPubMed Tsui JC, Souza DS, Filbey D, Bomfim V, Dashwood MR. Preserved endothelial integrity and nitric oxide synthase in saphenous vein grafts harvested by a 'no-touch' technique. Br J Surg. 2001;88:1209–15.CrossRefPubMed
14.
go back to reference Dreifaldt M, Souza DS, Loesch A, et al. The “no-touch” harvesting technique for vein grafts in coronary artery bypass surgery preserves an intact vasa vasorum. J Thorac Cardiovasc Surg. 2011;141:145–50.CrossRefPubMed Dreifaldt M, Souza DS, Loesch A, et al. The “no-touch” harvesting technique for vein grafts in coronary artery bypass surgery preserves an intact vasa vasorum. J Thorac Cardiovasc Surg. 2011;141:145–50.CrossRefPubMed
15.
go back to reference Fernández-Alfonso MS, Gil-Ortega M, Aranguez I, et al. Role of PVAT in coronary atherosclerosis and vein graft patency: friend or foe? Br J Pharmacol. 2017;174:3561–72.CrossRefPubMedPubMedCentral Fernández-Alfonso MS, Gil-Ortega M, Aranguez I, et al. Role of PVAT in coronary atherosclerosis and vein graft patency: friend or foe? Br J Pharmacol. 2017;174:3561–72.CrossRefPubMedPubMedCentral
16.
go back to reference Dashwood MR, Savage K, Tsui JC, et al. Retaining perivascular tissue of human saphenous vein grafts protects against surgical and distension-induced damage and preserves endothelial nitric oxide synthase and nitric oxide synthase activity. J Thorac Cardiovasc Surg. 2009;138:334–40.CrossRefPubMed Dashwood MR, Savage K, Tsui JC, et al. Retaining perivascular tissue of human saphenous vein grafts protects against surgical and distension-induced damage and preserves endothelial nitric oxide synthase and nitric oxide synthase activity. J Thorac Cardiovasc Surg. 2009;138:334–40.CrossRefPubMed
17.
go back to reference Johansson BL, Souza DS, Bodin L, et al. Slower progression of atherosclerosis in vein grafts harvested with “no touch” technique compared with conventional harvesting technique in coronary artery bypass grafting: an angiographic and intravascular ultrasound study. Eur J Cardiothorac Surg. 2010;38:414–9.CrossRefPubMed Johansson BL, Souza DS, Bodin L, et al. Slower progression of atherosclerosis in vein grafts harvested with “no touch” technique compared with conventional harvesting technique in coronary artery bypass grafting: an angiographic and intravascular ultrasound study. Eur J Cardiothorac Surg. 2010;38:414–9.CrossRefPubMed
19.
go back to reference Samano N, Geijer H, Lidén M, Fremes S, Bodin L, Souza D. The no-touch saphenous vein for coronary artery bypass grafting maintains a patency, after 16 years, comparable to the left internal thoracic artery: a randomized trial. J Thorac Cardiovasc Surg. 2015;150:880–8.CrossRefPubMed Samano N, Geijer H, Lidén M, Fremes S, Bodin L, Souza D. The no-touch saphenous vein for coronary artery bypass grafting maintains a patency, after 16 years, comparable to the left internal thoracic artery: a randomized trial. J Thorac Cardiovasc Surg. 2015;150:880–8.CrossRefPubMed
20.
go back to reference Verma S, Lovren F, Pan Y, et al. Pedicled no-touch saphenous vein graft harvest limits vascular smooth muscle cell activation: the PATENT saphenous vein graft study. Eur J Cardiothorac Surg. 2014;45:717–25.CrossRefPubMed Verma S, Lovren F, Pan Y, et al. Pedicled no-touch saphenous vein graft harvest limits vascular smooth muscle cell activation: the PATENT saphenous vein graft study. Eur J Cardiothorac Surg. 2014;45:717–25.CrossRefPubMed
21.
go back to reference Hwang HY, Kim MA, Seo JW, Kim KB. Endothelial preservation of the minimally manipulated saphenous vein composite graft: histologic and immunohistochemical study. J Thorac Cardiovasc Surg. 2012;144:690–6.CrossRefPubMed Hwang HY, Kim MA, Seo JW, Kim KB. Endothelial preservation of the minimally manipulated saphenous vein composite graft: histologic and immunohistochemical study. J Thorac Cardiovasc Surg. 2012;144:690–6.CrossRefPubMed
22.
go back to reference Hwang HY, Kim JS, Kim KB. Angiographic equivalency of off-pump saphenous vein and arterial composite grafts at one year. Ann Thorac Surg. 2010;90:516–21.CrossRefPubMed Hwang HY, Kim JS, Kim KB. Angiographic equivalency of off-pump saphenous vein and arterial composite grafts at one year. Ann Thorac Surg. 2010;90:516–21.CrossRefPubMed
23.
go back to reference Hwang HY, Kim JS, Oh SJ, Kim KB. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: Early results. J Thorac Cardiovasc Surg. 2012;144:1027–33.CrossRefPubMed Hwang HY, Kim JS, Oh SJ, Kim KB. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: Early results. J Thorac Cardiovasc Surg. 2012;144:1027–33.CrossRefPubMed
24.
go back to reference Kim KB, Hwang HY, Hahn S, Kim JS, Oh SJ. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: One-year angiographic results and mid-term clinical outcomes. J Thorac Cardiovasc Surg. 2014;148:901–8.CrossRefPubMed Kim KB, Hwang HY, Hahn S, Kim JS, Oh SJ. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: One-year angiographic results and mid-term clinical outcomes. J Thorac Cardiovasc Surg. 2014;148:901–8.CrossRefPubMed
25.
go back to reference Hwang HY, Lee KH, Han JW, Kim KB. Equivalency of saphenous vein and arterial composite grafts: 5-year angiography and midterm clinical follow-up. Ann Thorac Surg. 2016;102:580–8.CrossRefPubMed Hwang HY, Lee KH, Han JW, Kim KB. Equivalency of saphenous vein and arterial composite grafts: 5-year angiography and midterm clinical follow-up. Ann Thorac Surg. 2016;102:580–8.CrossRefPubMed
26.
go back to reference Kim YH, Oh HC, Choi JW, Hwang HY, Kim KB. No-touch saphenous Vein harvesting may improve further the patency of saphenous vein composite grafts: early outcomes and 1-year angiographic results. Ann Thorac Surg. 2017;103:1489–97.CrossRefPubMed Kim YH, Oh HC, Choi JW, Hwang HY, Kim KB. No-touch saphenous Vein harvesting may improve further the patency of saphenous vein composite grafts: early outcomes and 1-year angiographic results. Ann Thorac Surg. 2017;103:1489–97.CrossRefPubMed
27.
go back to reference Gaudino M, Alessandrini F, Pragliola C, et al. Composite Y internal thoracic artery-saphenous vein grafts: short-term angiographic results and vasoreactive profile. J Thorac Cardiovasc Surg. 2004;127:1139–44.CrossRefPubMed Gaudino M, Alessandrini F, Pragliola C, et al. Composite Y internal thoracic artery-saphenous vein grafts: short-term angiographic results and vasoreactive profile. J Thorac Cardiovasc Surg. 2004;127:1139–44.CrossRefPubMed
28.
go back to reference Glineur D, Boodhwani M, Poncelet A, et al. Comparison of fractional flow reserve of composite Y-grafts with saphenous vein or right internal thoracic arteries. J Thorac Cardiovasc Surg. 2010;140:639–45.CrossRefPubMed Glineur D, Boodhwani M, Poncelet A, et al. Comparison of fractional flow reserve of composite Y-grafts with saphenous vein or right internal thoracic arteries. J Thorac Cardiovasc Surg. 2010;140:639–45.CrossRefPubMed
29.
go back to reference Hwang HY, Koo BK, Oh SJ, Kim KB. Morphologic changes of the saphenous vein Y-composite graft based on the left internal thoracic artery: 1-year intravascular ultrasound study. J Thorac Cardiovasc Surg. 2015;149:487–93.CrossRefPubMed Hwang HY, Koo BK, Oh SJ, Kim KB. Morphologic changes of the saphenous vein Y-composite graft based on the left internal thoracic artery: 1-year intravascular ultrasound study. J Thorac Cardiovasc Surg. 2015;149:487–93.CrossRefPubMed
30.
go back to reference Hwang HY, Koo BK, Yeom SY, Kim TK, Kim KB. Endothelial shear stress of the saphenous vein composite graft based on the internal thoracic artery. Ann Thorac Surg. 2018;105:564–71.CrossRefPubMed Hwang HY, Koo BK, Yeom SY, Kim TK, Kim KB. Endothelial shear stress of the saphenous vein composite graft based on the internal thoracic artery. Ann Thorac Surg. 2018;105:564–71.CrossRefPubMed
31.
go back to reference Parsonnet V, Lari AA, Shah IH. New stent for support of veins in arterial grafts. Arch Surg. 1963;87:696–702.CrossRefPubMed Parsonnet V, Lari AA, Shah IH. New stent for support of veins in arterial grafts. Arch Surg. 1963;87:696–702.CrossRefPubMed
32.
go back to reference Ben-Gal Y, Taggart DP, Williams MR, et al. Expandable external support device to improve Saphenous Vein Graft Patency after CABG. J Cardiothorac Surg. 2013;8:122.CrossRefPubMedPubMedCentral Ben-Gal Y, Taggart DP, Williams MR, et al. Expandable external support device to improve Saphenous Vein Graft Patency after CABG. J Cardiothorac Surg. 2013;8:122.CrossRefPubMedPubMedCentral
33.
go back to reference Murphy GJ, Newby AC, Jeremy JY, Baumbach A, Angelini GD. A randomized trial of an external Dacron sheath for the prevention of vein graft disease: The Extent study. J Thorac Cardiovasc Surg. 2007;134:504–5.CrossRefPubMed Murphy GJ, Newby AC, Jeremy JY, Baumbach A, Angelini GD. A randomized trial of an external Dacron sheath for the prevention of vein graft disease: The Extent study. J Thorac Cardiovasc Surg. 2007;134:504–5.CrossRefPubMed
34.
go back to reference Rescigno G, Aratari C, Matteucci SM, et al. Saphenous vein graft wrapping by nitinol mesh: A word of caution. Thorac Cardiovasc Surg. 2015;63:292–7.PubMed Rescigno G, Aratari C, Matteucci SM, et al. Saphenous vein graft wrapping by nitinol mesh: A word of caution. Thorac Cardiovasc Surg. 2015;63:292–7.PubMed
35.
go back to reference Meirson T, Orion E, Di Mario C, et al. Flow patterns in externally stented saphenous vein grafts and development of intimal hyperplasia. J Thorac Cardiovasc Surg. 2015;150:871–8.CrossRefPubMed Meirson T, Orion E, Di Mario C, et al. Flow patterns in externally stented saphenous vein grafts and development of intimal hyperplasia. J Thorac Cardiovasc Surg. 2015;150:871–8.CrossRefPubMed
36.
go back to reference Webb CM, Orion E, Taggart DP, Channon KM, Di Mario C. OCT imaging of aorto-coronary vein graft pathology modified by external stenting: 1-year post-surgery. Eur Heart J Cardiovasc Imaging. 2016;17:1290–5.CrossRefPubMed Webb CM, Orion E, Taggart DP, Channon KM, Di Mario C. OCT imaging of aorto-coronary vein graft pathology modified by external stenting: 1-year post-surgery. Eur Heart J Cardiovasc Imaging. 2016;17:1290–5.CrossRefPubMed
37.
go back to reference Taggart DP, Amin S, Djordjevic J, et al. A prospective study of external stenting of saphenous vein grafts to the right coronary artery: the VEST II study. Eur J Cardiothorac Surg. 2017;51:952–8.CrossRefPubMed Taggart DP, Amin S, Djordjevic J, et al. A prospective study of external stenting of saphenous vein grafts to the right coronary artery: the VEST II study. Eur J Cardiothorac Surg. 2017;51:952–8.CrossRefPubMed
Metadata
Title
Saphenous vein: advances
Authors
Ki-Bong Kim
Ho Young Hwang
Domingos Savio Ramos de Souza
David Paul Taggart
Publication date
01-12-2018
Publisher
Springer Singapore
Published in
Indian Journal of Thoracic and Cardiovascular Surgery / Issue Special Issue 3/2018
Print ISSN: 0970-9134
Electronic ISSN: 0973-7723
DOI
https://doi.org/10.1007/s12055-018-0753-9

Other articles of this Special Issue 3/2018

Indian Journal of Thoracic and Cardiovascular Surgery 3/2018 Go to the issue