Skip to main content
Top
Published in: Neuroinformatics 4/2010

Open Access 01-12-2010

Open Database of Epileptic EEG with MRI and Postoperational Assessment of Foci—a Real World Verification for the EEG Inverse Solutions

Authors: Piotr Zwoliński, Marcin Roszkowski, Jaroslaw Żygierewicz, Stefan Haufe, Guido Nolte, Piotr J. Durka

Published in: Neuroinformatics | Issue 4/2010

Login to get access

Abstract

This paper introduces a freely accessible database http://​eeg.​pl/​epi, containing 23 datasets from patients diagnosed with and operated on for drug-resistant epilepsy. This was collected as part of the clinical routine at the Warsaw Memorial Child Hospital. Each record contains (1) pre-surgical electroencephalography (EEG) recording (10–20 system) with inter-ictal discharges marked separately by an expert, (2) a full set of magnetic resonance imaging (MRI) scans for calculations of the realistic forward models, (3) structural placement of the epileptogenic zone, recognized by electrocorticography (ECoG) and post-surgical results, plotted on pre-surgical MRI scans in transverse, sagittal and coronal projections, (4) brief clinical description of each case. The main goal of this project is evaluation of possible improvements of localization of epileptic foci from the surface EEG recordings. These datasets offer a unique possibility for evaluating different EEG inverse solutions. We present preliminary results from a subset of these cases, including comparison of different schemes for the EEG inverse solution and preprocessing. We report also a finding which relates to the selective parametrization of single waveforms by multivariate matching pursuit, which is used in the preprocessing for the inverse solutions. It seems to offer a possibility of tracing the spatial evolution of seizures in time.
Literature
go back to reference Cao, N., Yetik, I., Nehorai, A., Muravchik, C., & Haueisen, J. (2006). Parametric surface-source modeling and estimation with electroencephalography. IEEE Transactions On Biomedical Engineering, 53(12 Pt 1), 2414–24.PubMedCrossRef Cao, N., Yetik, I., Nehorai, A., Muravchik, C., & Haueisen, J. (2006). Parametric surface-source modeling and estimation with electroencephalography. IEEE Transactions On Biomedical Engineering, 53(12 Pt 1), 2414–24.PubMedCrossRef
go back to reference Durka, P. (2007). Matching pursuit and unification in EEG analysis. Artech House, isbn 978-1-58053-304-1 edition. Durka, P. (2007). Matching pursuit and unification in EEG analysis. Artech House, isbn 978-1-58053-304-1 edition.
go back to reference Durka, P., Matysiak, A., Martinez-Montes, E., Valdes-Sosa, P., & Blinowska, K. (2005). Multichannel matching pursuit and EEG inverse solutions. Journal of Neuroscience Methods, 148(1), 49–59.PubMedCrossRef Durka, P., Matysiak, A., Martinez-Montes, E., Valdes-Sosa, P., & Blinowska, K. (2005). Multichannel matching pursuit and EEG inverse solutions. Journal of Neuroscience Methods, 148(1), 49–59.PubMedCrossRef
go back to reference Eckersley, P., Egan, G., De Schutter, E., Yiyuan, T., Novak, M., Sebesta, V., et al. (2003). Neuroscience data and tool sharing. Neuroinformatics, 1(2), 149–165.PubMedCrossRef Eckersley, P., Egan, G., De Schutter, E., Yiyuan, T., Novak, M., Sebesta, V., et al. (2003). Neuroscience data and tool sharing. Neuroinformatics, 1(2), 149–165.PubMedCrossRef
go back to reference Ermer, J., Mosher, J., Huang, M., & Leahy, R. (2000). Paired MEG data set source localization using recursively applied and projected (RAP) MUSIC. IEEE Transactions on Biomedical Engineering, 47(9), 1248–60.PubMedCrossRef Ermer, J., Mosher, J., Huang, M., & Leahy, R. (2000). Paired MEG data set source localization using recursively applied and projected (RAP) MUSIC. IEEE Transactions on Biomedical Engineering, 47(9), 1248–60.PubMedCrossRef
go back to reference Haufe, S., Nikulin, V., Ziehe, A., Müller, K., & Nolte, G. (2008). Combining sparsity and rotational invariance in EEG/MEG source reconstruction. Neuroimage, 42(2), 726–738.PubMedCrossRef Haufe, S., Nikulin, V., Ziehe, A., Müller, K., & Nolte, G. (2008). Combining sparsity and rotational invariance in EEG/MEG source reconstruction. Neuroimage, 42(2), 726–738.PubMedCrossRef
go back to reference Irimia, A., Swinney, K., & Wikswo, J. (2009). Partial independence of bioelectric and biomagnetic fields and its implications for encephalography and cardiography. Physical Review. E, Statistical, Nonlinear And Soft Matter Physics, 79(5 Pt 1), 051908. Irimia, A., Swinney, K., & Wikswo, J. (2009). Partial independence of bioelectric and biomagnetic fields and its implications for encephalography and cardiography. Physical Review. E, Statistical, Nonlinear And Soft Matter Physics, 79(5 Pt 1), 051908.
go back to reference Karbowski, K. (1990). Sixty years of clinical electroencephalography. European Neurology, 30(3), 170–175.PubMedCrossRef Karbowski, K. (1990). Sixty years of clinical electroencephalography. European Neurology, 30(3), 170–175.PubMedCrossRef
go back to reference Kemp, B., Värri, A., Rosa, A. C., Nielsen, K. D., & Gade, J. (1992). A simple format for exchange of digitized polygraphic recordings. Electroencephalography and Clinical Neurophysiology, 82, 391–393.PubMedCrossRef Kemp, B., Värri, A., Rosa, A. C., Nielsen, K. D., & Gade, J. (1992). A simple format for exchange of digitized polygraphic recordings. Electroencephalography and Clinical Neurophysiology, 82, 391–393.PubMedCrossRef
go back to reference Koffler, D. J., & Gotman, J. (1985). Automatic detection of spike-and-wave bursts in ambulatory EEG recordings. Electroencephalography and Clinical Neurophysiology, 61(2), 165–180.PubMedCrossRef Koffler, D. J., & Gotman, J. (1985). Automatic detection of spike-and-wave bursts in ambulatory EEG recordings. Electroencephalography and Clinical Neurophysiology, 61(2), 165–180.PubMedCrossRef
go back to reference Loddenkemper, T., & Kotagal, P. (2005). Lateralizing signs during seizures in focal epilepsy. Epilepsy & Behavior, 7(1), 1–17.CrossRef Loddenkemper, T., & Kotagal, P. (2005). Lateralizing signs during seizures in focal epilepsy. Epilepsy & Behavior, 7(1), 1–17.CrossRef
go back to reference Mallat, S., & Zhang, Z. (1993). Matching pursuit with time-frequency dictionaries. IEEE Transactions on Signal Processing, 41, 3397–3415.CrossRef Mallat, S., & Zhang, Z. (1993). Matching pursuit with time-frequency dictionaries. IEEE Transactions on Signal Processing, 41, 3397–3415.CrossRef
go back to reference Molins, A., Stufflebeam, S., Brown, E., & Hämäläinen, M. (2008). Quantification of the benefit from integrating MEG and EEG data in minimum l2-norm estimation. NeuroImage, 42(3), 1069–1077.PubMedCrossRef Molins, A., Stufflebeam, S., Brown, E., & Hämäläinen, M. (2008). Quantification of the benefit from integrating MEG and EEG data in minimum l2-norm estimation. NeuroImage, 42(3), 1069–1077.PubMedCrossRef
go back to reference Mosher, J., Lewis, P., & Leahy, R. (1992). Multiple dipole modeling and localization from spatio-temporal MEG data. IEEE Transactions on Biomedical Engineering, 39(6), 541–557.PubMedCrossRef Mosher, J., Lewis, P., & Leahy, R. (1992). Multiple dipole modeling and localization from spatio-temporal MEG data. IEEE Transactions on Biomedical Engineering, 39(6), 541–557.PubMedCrossRef
go back to reference Niedermeyer, E., & Lopes da Silva, F. H. (2004). Electroencephalography: Basic principles, clinical applications, and related fields (p. 140). Lippincott Williams & Wilkins. Niedermeyer, E., & Lopes da Silva, F. H. (2004). Electroencephalography: Basic principles, clinical applications, and related fields (p. 140). Lippincott Williams & Wilkins.
go back to reference Nolte, G., & Dassios, G. (2005). Analytic expansion of the EEG lead field for realistic volume conductors. Physics in Medicine & Biology, 50, 3807–3823.CrossRef Nolte, G., & Dassios, G. (2005). Analytic expansion of the EEG lead field for realistic volume conductors. Physics in Medicine & Biology, 50, 3807–3823.CrossRef
go back to reference Ou, W., Hämäläinen, M., & Golland, P. (2009). A distributed spatio-temporal EEG/MEG inverse solver. NeuroImage, 44(3), 932–946.PubMedCrossRef Ou, W., Hämäläinen, M., & Golland, P. (2009). A distributed spatio-temporal EEG/MEG inverse solver. NeuroImage, 44(3), 932–946.PubMedCrossRef
go back to reference Pascual-Marqui, R., Esslen, M., Kochi, K., & Lehmann, D. (2002). Functional imaging with low-resolution brain electromagnetic tomography (LORETA): A review. Methods and Findings In Experimental And Clinical Pharmacology, 24(Suppl C), 91–95.PubMed Pascual-Marqui, R., Esslen, M., Kochi, K., & Lehmann, D. (2002). Functional imaging with low-resolution brain electromagnetic tomography (LORETA): A review. Methods and Findings In Experimental And Clinical Pharmacology, 24(Suppl C), 91–95.PubMed
go back to reference Penin, H. (1968). Electronische Patientenuberwachung in der Nervenklinik Bonn (Electronic patient monitoring in the neurologic hospital of Bonn). Umsschau in Wissenschaft und Technik, 7, 211–212. Penin, H. (1968). Electronische Patientenuberwachung in der Nervenklinik Bonn (Electronic patient monitoring in the neurologic hospital of Bonn). Umsschau in Wissenschaft und Technik, 7, 211–212.
go back to reference Pillai, J., & Sperling, M. (2006). Interictal EEG and the diagnosis of epilepsy. Epilepsia, 47(Suppl 1), 14–22.PubMedCrossRef Pillai, J., & Sperling, M. (2006). Interictal EEG and the diagnosis of epilepsy. Epilepsia, 47(Suppl 1), 14–22.PubMedCrossRef
go back to reference Sekihara, K., Sahani, M., & Nagarajan, S. (2005). Localization bias and spatial resolution of adaptive and non-adaptive spatial filters for MEG source reconstruction. NeuroImage, 25(4), 1056–1067.PubMedCrossRef Sekihara, K., Sahani, M., & Nagarajan, S. (2005). Localization bias and spatial resolution of adaptive and non-adaptive spatial filters for MEG source reconstruction. NeuroImage, 25(4), 1056–1067.PubMedCrossRef
go back to reference Veen, B. V., van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997). Localization of brain electrical activity via linearly constrained minimum variance spatial filtering. IEEE Transactions on Biomedical Engineering, 44(9), 867–880.PubMedCrossRef Veen, B. V., van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997). Localization of brain electrical activity via linearly constrained minimum variance spatial filtering. IEEE Transactions on Biomedical Engineering, 44(9), 867–880.PubMedCrossRef
go back to reference Wong, P. K. (1998). Potential fields, EEG maps, and cortical spike generators. Electroencephalography and Clinical Neurophysiology, 106(2), 138–141.PubMedCrossRef Wong, P. K. (1998). Potential fields, EEG maps, and cortical spike generators. Electroencephalography and Clinical Neurophysiology, 106(2), 138–141.PubMedCrossRef
Metadata
Title
Open Database of Epileptic EEG with MRI and Postoperational Assessment of Foci—a Real World Verification for the EEG Inverse Solutions
Authors
Piotr Zwoliński
Marcin Roszkowski
Jaroslaw Żygierewicz
Stefan Haufe
Guido Nolte
Piotr J. Durka
Publication date
01-12-2010
Publisher
Humana Press Inc
Published in
Neuroinformatics / Issue 4/2010
Print ISSN: 1539-2791
Electronic ISSN: 1559-0089
DOI
https://doi.org/10.1007/s12021-010-9086-6

Other articles of this Issue 4/2010

Neuroinformatics 4/2010 Go to the issue