Excerpt

Acetabular dysplasia commonly causes secondary arthritis of the hip [2]. Today, the so-called Bernese periacetabular osteotomy (PAO) is one of the most frequently and successfully used joint preserving surgical procedures designed to manage dysplasia in the young active patient [12]. This complex procedure combines a polygonal juxta-articular osteotomy using a modified Smith-Peterson approach. Proper acetabular reorientation can improve long-term survivorship and decelerate the progression of degenerative changes [1]. Overcorrection can produce femoroacetabular impingement, undercorrection may leave a patient with persistent symptoms, and poor congruency of the joint can cause abnormal contact stresses and accelerated chondral damage [4, 9]. Thorough preoperative planning is fundamental in PAO, and is based on plain radiographs and, more importantly, on CT imaging [6]. Clearly, accurate intraoperative imaging is required for implementation of the surgical plan. Fluoroscopy is commonly used for guidance while carrying out this complex osteotomy and for assessment of acetabular fragment reorientation, femoral head coverage, and osteotomy fixation. High-volume surgeons with extensive PAO experience do not necessarily need intraoperative fluoroscopy to check their osteotomy positioning, and prefer plain radiographs for assessment of acetabular reorientation. Intraoperative plain full pelvis radiographs are still considered the best available test under reasonable conditions [2]. However, serial intraoperative radiographs are time-consuming, and therefore, often are replaced by fluoroscopy. …
Literature
1.
go back to reference Albers CE, Steppacher SD, Ganz R, Tannast M, Siebenrock KA. Impingement adversely affects 10-year survivorship after periacetabular osteotomy for DDH. Clin Orthop Relat Res. 2013;471:1602–1614.CrossRefPubMedPubMedCentral Albers CE, Steppacher SD, Ganz R, Tannast M, Siebenrock KA. Impingement adversely affects 10-year survivorship after periacetabular osteotomy for DDH. Clin Orthop Relat Res. 2013;471:1602–1614.CrossRefPubMedPubMedCentral
2.
go back to reference Ganz R, Klaue K, Vinh TS, Mast JW. A new periacetabular osteotomy for the treatment of hip dysplasias. Technique and preliminary results. Clin Orthop Rel Res. 1988;232:26–36. Ganz R, Klaue K, Vinh TS, Mast JW. A new periacetabular osteotomy for the treatment of hip dysplasias. Technique and preliminary results. Clin Orthop Rel Res. 1988;232:26–36.
3.
go back to reference Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA. Accuracy of pedicle screw placement: A systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J. 2012;21:247–255.CrossRefPubMed Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA. Accuracy of pedicle screw placement: A systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J. 2012;21:247–255.CrossRefPubMed
4.
go back to reference Hartig-Andreasen C, Troelsen A, Thillemann TM, Søballe K. What factors predict failure 4 to 12 years after periacetabular osteotomy? Clin Orthop Relat Res. 2012;470:2978–2987.CrossRefPubMedPubMedCentral Hartig-Andreasen C, Troelsen A, Thillemann TM, Søballe K. What factors predict failure 4 to 12 years after periacetabular osteotomy? Clin Orthop Relat Res. 2012;470:2978–2987.CrossRefPubMedPubMedCentral
5.
go back to reference Hsieh PH, Chang YH, Shih CH. Image-guided periacetabular osteotomy: computer-assisted navigation compared with the conventional technique: a randomized study of 36 patients followed for 2 years. Acta Orthop. 2006;4:591–597.CrossRef Hsieh PH, Chang YH, Shih CH. Image-guided periacetabular osteotomy: computer-assisted navigation compared with the conventional technique: a randomized study of 36 patients followed for 2 years. Acta Orthop. 2006;4:591–597.CrossRef
6.
go back to reference Klaue K, Wallin A, Ganz R. CT evaluation of coverage and congruency of the hip prior to osteotomy. Clin Orthop Relat Res. 1988;232:15–25. Klaue K, Wallin A, Ganz R. CT evaluation of coverage and congruency of the hip prior to osteotomy. Clin Orthop Relat Res. 1988;232:15–25.
7.
go back to reference Langlotz F, Bächler R, Berlemann U, Nolte LP, Ganz R. Computer assistance for pelvic osteotomies. Clin Orthop Relat Res. 1998;354:92–102.CrossRef Langlotz F, Bächler R, Berlemann U, Nolte LP, Ganz R. Computer assistance for pelvic osteotomies. Clin Orthop Relat Res. 1998;354:92–102.CrossRef
8.
go back to reference Murphy RJ, Armiger RS, Lepistö J, Armand M. Clinical evaluation of a biomechanical guidance system for periacetabular osteotomy. J Orthop Surg Res. 2016;11:36.CrossRefPubMedPubMedCentral Murphy RJ, Armiger RS, Lepistö J, Armand M. Clinical evaluation of a biomechanical guidance system for periacetabular osteotomy. J Orthop Surg Res. 2016;11:36.CrossRefPubMedPubMedCentral
9.
go back to reference Novais EN, Carry PM, Kestel LA, Ketterman B, Brusalis CM, Sankar WN. Does surgeon experience impact the risk of complications after Bernese periacetabular osteotomy? Clin Orthop Relat Res. [Published online ahead of print August 5, 2016]. DOI: 10.1007/s11999-016-5010-1. Novais EN, Carry PM, Kestel LA, Ketterman B, Brusalis CM, Sankar WN. Does surgeon experience impact the risk of complications after Bernese periacetabular osteotomy? Clin Orthop Relat Res. [Published online ahead of print August 5, 2016]. DOI: 10.​1007/​s11999-016-5010-1.
10.
go back to reference Post LK, Kirchhoff C, Toepfer A, Kirchhoff S, Schmitt-Sody M, von Eisenhart-Rothe R, Burgkart R. Potential accuracy of navigated K-wire guided supra-acetabular osteotomies in orthopedic surgery: A CT fluoroscopy cadaver study. Int J Med Robot. [Published online ahead of print June 8, 2016]. DOI: 10.1002/rcs.1752. Post LK, Kirchhoff C, Toepfer A, Kirchhoff S, Schmitt-Sody M, von Eisenhart-Rothe R, Burgkart R. Potential accuracy of navigated K-wire guided supra-acetabular osteotomies in orthopedic surgery: A CT fluoroscopy cadaver study. Int J Med Robot. [Published online ahead of print June 8, 2016]. DOI: 10.​1002/​rcs.​1752.
11.
go back to reference So TY, Lam YL, Mak KL. Computer-assisted navigation in bone tumor surgery: Seamless workflow model and evolution of technique. Clin Orthop Relat Res. 2010;468:2985–2991.CrossRefPubMedPubMedCentral So TY, Lam YL, Mak KL. Computer-assisted navigation in bone tumor surgery: Seamless workflow model and evolution of technique. Clin Orthop Relat Res. 2010;468:2985–2991.CrossRefPubMedPubMedCentral
12.
go back to reference Steppacher SD, Tannast M, Ganz R, Siebenrock KA. Mean 20-year followup of Bernese periacetabular osteotomy. Clin Orthop Relat Res. 2008;466:1633–1644.CrossRefPubMedPubMedCentral Steppacher SD, Tannast M, Ganz R, Siebenrock KA. Mean 20-year followup of Bernese periacetabular osteotomy. Clin Orthop Relat Res. 2008;466:1633–1644.CrossRefPubMedPubMedCentral
13.
go back to reference Wong JM, Bewsher S, Yew J, Bucknill A, de Steiger R. Fluoroscopically assisted computer navigation enables accurate percutaneous screw placement for pelvic and acetabular fracture fixation. Injury. 2015;46:1064–1068.CrossRefPubMed Wong JM, Bewsher S, Yew J, Bucknill A, de Steiger R. Fluoroscopically assisted computer navigation enables accurate percutaneous screw placement for pelvic and acetabular fracture fixation. Injury. 2015;46:1064–1068.CrossRefPubMed
Metadata
Title
CORR Insights®: Operative Fluoroscopic Correction Is Reliable and Correlates With Postoperative Radiographic Correction in Periacetabular Osteotomy
Author
Rocco P. Pitto, MD, PhD, FRACS
Publication date
01-04-2017
Publisher
Springer US
Published in
Clinical Orthopaedics and Related Research® / Issue 4/2017
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-016-5111-x

Other articles of this Issue 4/2017

Clinical Orthopaedics and Related Research® 4/2017 Go to the issue