Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 7/2016

01-07-2016 | From Bench to Bedside

From Bench to Bedside: How Stiff is Too Stiff? Far-cortical Locking or Dynamic Locked Plating May Obviate the Question

Author: Benjamin K. Potter, MD

Published in: Clinical Orthopaedics and Related Research® | Issue 7/2016

Login to get access

Excerpt

Plate-and-screw fracture fixation represents, at its core, perhaps the most basic and stereotypical of orthopaedic surgery procedures—the “bone broke, me fix” or “sterile carpentry” punchline of so many medical jokes. For many simple fracture patterns, compression plating, absolute stability, and primary bone healing work well. Achieving stable, rigid fixation represents a core principle of this approach. Over the last 15 years, the development of locking screws and locked-plating has allowed us to increase construct rigidity, improve purchase and stability in osteoporotic or otherwise compromised bone, and changed our approach to many comminuted fractures. These developments have enabled, and been accompanied by, greater interest in minimally invasive plate osteosynthesis, which better respects the soft-tissues and periosteal blood supply. This minimally invasive plate osteosynthesis seeks to preserve biology and improve the capacity for fracture healing. Far-cortical locking and active locked-plating of fractures represent, perhaps, the next revolution in fracture fixation. …
Literature
1.
go back to reference Bottlang M, Doornink J, Fitzpatrick DC, Madey SM. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength. J Bone Joint Surg Am. 2009;91:1985–1994.CrossRefPubMedPubMedCentral Bottlang M, Doornink J, Fitzpatrick DC, Madey SM. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength. J Bone Joint Surg Am. 2009;91:1985–1994.CrossRefPubMedPubMedCentral
2.
go back to reference Bottlang M, Fitzpatrick DC, Sheerin D, Kubiak E, Gellman R, Vande Zandschulp C, Doornink J, Earley K, Madey SM. Dynamic fixation of distal femur fractures using far cortical locking screws: A prospective observational study. J Orthop Trauma. 2014;28:181–188.CrossRefPubMed Bottlang M, Fitzpatrick DC, Sheerin D, Kubiak E, Gellman R, Vande Zandschulp C, Doornink J, Earley K, Madey SM. Dynamic fixation of distal femur fractures using far cortical locking screws: A prospective observational study. J Orthop Trauma. 2014;28:181–188.CrossRefPubMed
3.
go back to reference Bottlang M, Tsai S, Bliven EK, von Rechenberg B, Klein K, Augat P, Henschel J, Fitzpatrick DC, Madey SM. Dynamic stabilization with active locking plates delivers faster, stronger, and more symmetric fracture-healing. J Bone Joint Surg Am. 2016;98:466–474.CrossRefPubMed Bottlang M, Tsai S, Bliven EK, von Rechenberg B, Klein K, Augat P, Henschel J, Fitzpatrick DC, Madey SM. Dynamic stabilization with active locking plates delivers faster, stronger, and more symmetric fracture-healing. J Bone Joint Surg Am. 2016;98:466–474.CrossRefPubMed
4.
go back to reference Claes L. Biomechanical principles and mechanobiologic aspects of flexible and locked plating. J Orthop Trauma. 2011;25(suppl 1):S4–S7.CrossRefPubMed Claes L. Biomechanical principles and mechanobiologic aspects of flexible and locked plating. J Orthop Trauma. 2011;25(suppl 1):S4–S7.CrossRefPubMed
5.
go back to reference Elkins J, Marsh JL, Lujan T, Peindl R, Kellam J, Anderson DD, Lack W. Motion predicts clinical callus formation: Construct-specific finite element analysis of supracondylar femoral fractures. J Bone Joint Surg Am. 2016;98:276–284.CrossRefPubMed Elkins J, Marsh JL, Lujan T, Peindl R, Kellam J, Anderson DD, Lack W. Motion predicts clinical callus formation: Construct-specific finite element analysis of supracondylar femoral fractures. J Bone Joint Surg Am. 2016;98:276–284.CrossRefPubMed
6.
go back to reference Foux A, Yeadon AJ, Uhthoff HK. Improved fracture healing with less rigid plates. A biomechanical study in dogs. Clin Orthop Relat Res. 1997;339:232–245.CrossRefPubMed Foux A, Yeadon AJ, Uhthoff HK. Improved fracture healing with less rigid plates. A biomechanical study in dogs. Clin Orthop Relat Res. 1997;339:232–245.CrossRefPubMed
7.
go back to reference Goodship AE, Kenwright J. The influence of induced micromovement upon the healing of experimental tibial fractures. J Bone Joint Surg Br. 1985;67:650–655.PubMed Goodship AE, Kenwright J. The influence of induced micromovement upon the healing of experimental tibial fractures. J Bone Joint Surg Br. 1985;67:650–655.PubMed
8.
go back to reference Henderson CE, Lujan TJ, Kuhl LL, Bottlang M, Fitzpatrick DC, Marsh JL. 2010 Mid-America Orthopaedic Association Physician in Training Award: Healing complications are common after locked plating for distal femur fractures. Clin Orthop Relat Res. 2011;469:1757–1765.CrossRefPubMedPubMedCentral Henderson CE, Lujan TJ, Kuhl LL, Bottlang M, Fitzpatrick DC, Marsh JL. 2010 Mid-America Orthopaedic Association Physician in Training Award: Healing complications are common after locked plating for distal femur fractures. Clin Orthop Relat Res. 2011;469:1757–1765.CrossRefPubMedPubMedCentral
9.
go back to reference Holzman MA, Hanus BD, Munz JW, O’Connor DP, Brinker MR. Addition of a medial locking plate to an in situ lateral lock plate results in healing of distal femoral nonunions. Clin Orthop Relat Res. [Published online ahead of print January 21, 2016]. DOI: 10.1007/s11999-016-4709-3. Holzman MA, Hanus BD, Munz JW, O’Connor DP, Brinker MR. Addition of a medial locking plate to an in situ lateral lock plate results in healing of distal femoral nonunions. Clin Orthop Relat Res. [Published online ahead of print January 21, 2016]. DOI: 10.​1007/​s11999-016-4709-3.
10.
go back to reference Perren SM. Evolution of the internal fixation of long bone fractures: The scientific basis of biological internal fixation: Choosing a new balance between stability and biology. J Bone Joint Surg Br. 2002;84:1093–1110.CrossRefPubMed Perren SM. Evolution of the internal fixation of long bone fractures: The scientific basis of biological internal fixation: Choosing a new balance between stability and biology. J Bone Joint Surg Br. 2002;84:1093–1110.CrossRefPubMed
11.
go back to reference Rodriguez EK, Zurakowski D, Herder L, Hall A, Walley KC, Weaver MJ, Appleton PT, Vrahas M. Mechanical construct characteristics predisposing to nonunion after locked lateral plating of the distal femur fractures. J Orthop Trauma. [Published online ahead of print March 29, 2016]. DOI: 10.1097/BOT.0000000000000593. Rodriguez EK, Zurakowski D, Herder L, Hall A, Walley KC, Weaver MJ, Appleton PT, Vrahas M. Mechanical construct characteristics predisposing to nonunion after locked lateral plating of the distal femur fractures. J Orthop Trauma. [Published online ahead of print March 29, 2016]. DOI: 10.​1097/​BOT.​0000000000000593​.
Metadata
Title
From Bench to Bedside: How Stiff is Too Stiff? Far-cortical Locking or Dynamic Locked Plating May Obviate the Question
Author
Benjamin K. Potter, MD
Publication date
01-07-2016
Publisher
Springer US
Published in
Clinical Orthopaedics and Related Research® / Issue 7/2016
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-016-4885-1

Other articles of this Issue 7/2016

Clinical Orthopaedics and Related Research® 7/2016 Go to the issue