Abstract

Background

Maintaining robust perfusion is an important physiologic parameter in wound healing. The effect of different closure techniques on wound perfusion after total knee arthroplasty (TKA) has not been established previously and may have implications for wound healing.

Questions/purposes

We asked whether a running subcuticular, vertical mattress, or skin staple closure technique enables the most robust wound perfusion after TKA as measured by laser-assisted indocyanine green angiography (LA-ICGA) in patients without specific risk factors for wound healing complications.

Methods

Forty-five patients undergoing primary TKA without comorbidities known to impact wound healing and perfusion were prospectively randomized to receive superficial skin closure with one of the following techniques: (1) running subcuticular (3-0 monofilament); (2) vertical mattress (2-0 nylon); or (3) skin staples. Twenty procedures were performed by RTT, 15 by RJS, and 10 by FHS. All surgeons used an anterior skin incision over the medial third of the patella in combination with a median parapatellar arthrotomy. Perfusion was assessed with a LA-ICGA device and software system immediately after closure to quantify fluorescence. Twenty-seven points were assessed immediately after closure in the operating room in each patient (nine along the incision and nine pairs medial and lateral to the incision). Mean incision perfusion was determined from the nine points along the incision with higher values indicating greater blood flow. Mean perfusion impairment was determined by calculating the difference between the nine pairs of surrounding skin and the nine points along the incision with smaller values indicating less perfusion impairment. These parameters were compared with analysis of variance (ANOVA) and subsequent pairwise comparisons with an unadjusted analysis as well as a multivariate analysis that adjusted for age, sex, and body mass index. Patients were followed for a mean of 7 months after surgery (range, 3–12 months) for possible incision-related complications. No patents were lost to followup.

Results

Running subcuticular closure demonstrated the best overall perfusion. Mean incision perfusion in fluorescent units with SD was as follows: running subcuticular, 64 (16); vertical mattress, 32 (18); and staples, 19 (7) (ANOVA p < 0.001). The running subcuticular closure demonstrated the least impairment of perfusion among the closures compared. Mean perfusion impairment was as follows: running subcuticular, 21 (12); vertical mattress, 37 (24); and staples, 69 (27) (ANOVA p < 0.001). All Tukey-adjusted pairwise comparisons from both metrics likewise favored the subcuticular closure (p < 0.001) both before and after adjusting for age, sex, and body mass index. One patient in the vertical mattress cohort experienced a surgical site infection; no other wound-related complications were observed in this study.

Conclusions

The method of closure can influence skin and soft tissue perfusion after TKA. Running subcuticular closure enables the most physiologic robust blood flow, which may improve wound healing. However, the clinical importance of these findings remains uncertain, because patients in this study were selected because they lacked risk factors for wound healing complications. Studies with this modality in specific patient populations at higher risk for wound complications will be necessary to quantify the clinical advantage of using running subcuticular closure.

Level of Evidence

Level I, therapeutic study.
Literature
1.
go back to reference Dennis DA. Wound complications in total knee arthroplasty. Orthopedics. 1997;20:837–840.PubMed Dennis DA. Wound complications in total knee arthroplasty. Orthopedics. 1997;20:837–840.PubMed
2.
go back to reference Eggers MD, Fang L, Lionberger DR. A comparison of wound closure techniques for total knee arthroplasty. J Arthroplasty. 2011;26:1251–1258.e1251–1254. Eggers MD, Fang L, Lionberger DR. A comparison of wound closure techniques for total knee arthroplasty. J Arthroplasty. 2011;26:1251–1258.e1251–1254.
3.
go back to reference Graham DA, Jeffery JA, Bain D, Davies P, Bentley G. Staple vs. subcuticular vicryl skin closure in knee replacement surgery: a spectrophotographic assessment of wound characteristics. Knee. 2000;7:239–243.PubMedCrossRef Graham DA, Jeffery JA, Bain D, Davies P, Bentley G. Staple vs. subcuticular vicryl skin closure in knee replacement surgery: a spectrophotographic assessment of wound characteristics. Knee. 2000;7:239–243.PubMedCrossRef
4.
go back to reference Gurtner GC, Jones GE, Neligan PC, Newman MI, Phillips BT, Sacks JM, Zenn MR. Intraoperative laser angiography using the SPY system: review of the literature and recommendations for use. Ann Surg Innov Res. 2013;7:1.PubMedPubMedCentralCrossRef Gurtner GC, Jones GE, Neligan PC, Newman MI, Phillips BT, Sacks JM, Zenn MR. Intraoperative laser angiography using the SPY system: review of the literature and recommendations for use. Ann Surg Innov Res. 2013;7:1.PubMedPubMedCentralCrossRef
5.
go back to reference Jonsson K, Jensen JA, Goodson WH 3rd, Scheuenstuhl H, West J, Hopf HW, Hunt TK. Tissue oxygenation, anemia, and perfusion in relation to wound healing in surgical patients. Ann Surg. 1991;214:605–613.PubMedPubMedCentralCrossRef Jonsson K, Jensen JA, Goodson WH 3rd, Scheuenstuhl H, West J, Hopf HW, Hunt TK. Tissue oxygenation, anemia, and perfusion in relation to wound healing in surgical patients. Ann Surg. 1991;214:605–613.PubMedPubMedCentralCrossRef
6.
go back to reference Khan RJ, Fick D, Yao F, Tang K, Hurworth M, Nivbrant B, Wood D. A comparison of three methods of wound closure following arthroplasty: a prospective, randomised, controlled trial. J Bone Joint Surg Br. 2006;88:238–242.PubMedCrossRef Khan RJ, Fick D, Yao F, Tang K, Hurworth M, Nivbrant B, Wood D. A comparison of three methods of wound closure following arthroplasty: a prospective, randomised, controlled trial. J Bone Joint Surg Br. 2006;88:238–242.PubMedCrossRef
7.
go back to reference Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89:780–785.PubMedCrossRef Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89:780–785.PubMedCrossRef
8.
go back to reference Kurtz SM, Lau E, Ong K, Zhao K, Kelly M, Bozic KJ. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030. Clin Orthop Relat Res. 2009;467:2606–2612.PubMedPubMedCentralCrossRef Kurtz SM, Lau E, Ong K, Zhao K, Kelly M, Bozic KJ. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030. Clin Orthop Relat Res. 2009;467:2606–2612.PubMedPubMedCentralCrossRef
9.
go back to reference Kurtz SM, Ong KL, Lau E, Bozic KJ, Berry D, Parvizi J. Prosthetic joint infection risk after TKA in the Medicare population. Clin Orthop Relat Res. 2010;468:52–56.PubMedPubMedCentralCrossRef Kurtz SM, Ong KL, Lau E, Bozic KJ, Berry D, Parvizi J. Prosthetic joint infection risk after TKA in the Medicare population. Clin Orthop Relat Res. 2010;468:52–56.PubMedPubMedCentralCrossRef
10.
go back to reference Lepow B, Perry D, Armstrong D. The use of SPY intra-operative angiography as a predictor of wound healing. Podiatry Management. 2011;8:141–148. Lepow B, Perry D, Armstrong D. The use of SPY intra-operative angiography as a predictor of wound healing. Podiatry Management. 2011;8:141–148.
11.
go back to reference Losken A, Zenn MR, Hammel JA, Walsh MW, Carlson GW. Assessment of zonal perfusion using intraoperative angiography during abdominal flap breast reconstruction. Plast Reconstr Surg. 2012;129:618e–624e.PubMedCrossRef Losken A, Zenn MR, Hammel JA, Walsh MW, Carlson GW. Assessment of zonal perfusion using intraoperative angiography during abdominal flap breast reconstruction. Plast Reconstr Surg. 2012;129:618e–624e.PubMedCrossRef
12.
go back to reference Novadaq. The SPY Elite (Intraoperative Perfusion Assessment System Operator’s Manual, November 2011013-50001-001, rev C). Richmond, British Columbia, Canada: Novadaq Technologies; 2008. Novadaq. The SPY Elite (Intraoperative Perfusion Assessment System Operator’s Manual, November 2011013-50001-001, rev C). Richmond, British Columbia, Canada: Novadaq Technologies; 2008.
13.
go back to reference Pestana IA, Zenn MR. Correlation between abdominal perforator vessels identified with preoperative CT angiography and intraoperative fluorescent angiography in the microsurgical breast reconstruction patient. Ann Plast Surg. 2014;72:S144–149.PubMedCrossRef Pestana IA, Zenn MR. Correlation between abdominal perforator vessels identified with preoperative CT angiography and intraoperative fluorescent angiography in the microsurgical breast reconstruction patient. Ann Plast Surg. 2014;72:S144–149.PubMedCrossRef
14.
go back to reference Poss R, Thornhill TS, Ewald FC, Thomas WH, Batte NJ, Sledge CB. Factors influencing the incidence and outcome of infection following total joint arthroplasty. Clin Orthop Relat Res. 1984;182:117–126.PubMed Poss R, Thornhill TS, Ewald FC, Thomas WH, Batte NJ, Sledge CB. Factors influencing the incidence and outcome of infection following total joint arthroplasty. Clin Orthop Relat Res. 1984;182:117–126.PubMed
15.
go back to reference Shantz JA, Vernon J, Leiter J, Morshed S, Stranges G. Sutures versus staples for wound closure in orthopaedic surgery: a randomized controlled trial. BMC Musculoskelet Disord. 2012;13:89.PubMedPubMedCentralCrossRef Shantz JA, Vernon J, Leiter J, Morshed S, Stranges G. Sutures versus staples for wound closure in orthopaedic surgery: a randomized controlled trial. BMC Musculoskelet Disord. 2012;13:89.PubMedPubMedCentralCrossRef
16.
go back to reference Shetty AA, Kumar VS, Morgan-Hough C, Georgeu GA, James KD, Nicholl JE. Comparing wound complication rates following closure of hip wounds with metallic skin staples or subcuticular vicryl suture: a prospective randomised trial. J Orthop Surg (Hong Kong). 2004;12:191–193. Shetty AA, Kumar VS, Morgan-Hough C, Georgeu GA, James KD, Nicholl JE. Comparing wound complication rates following closure of hip wounds with metallic skin staples or subcuticular vicryl suture: a prospective randomised trial. J Orthop Surg (Hong Kong). 2004;12:191–193.
18.
go back to reference Stockley I, Elson RA. Skin closure using staples and nylon sutures: a comparison of results. Ann R Coll Surg Engl. 1987;69:76–78.PubMedPubMedCentral Stockley I, Elson RA. Skin closure using staples and nylon sutures: a comparison of results. Ann R Coll Surg Engl. 1987;69:76–78.PubMedPubMedCentral
19.
go back to reference Vince K, Chivas D, Droll KP. Wound complications after total knee arthroplasty. J Arthroplasty. 2007;22:39–44.PubMedCrossRef Vince K, Chivas D, Droll KP. Wound complications after total knee arthroplasty. J Arthroplasty. 2007;22:39–44.PubMedCrossRef
20.
go back to reference Vince KG, Abdeen A. Wound problems in total knee arthroplasty. Clin Orthop Relat Res. 2006;452:88–90.PubMedCrossRef Vince KG, Abdeen A. Wound problems in total knee arthroplasty. Clin Orthop Relat Res. 2006;452:88–90.PubMedCrossRef
21.
go back to reference Wyles CC, Taunton MJ, Jacobson SR, Tran NV, Sierra RJ, Trousdale RT. Intraoperative angiography provides objective assessment of skin perfusion in complex knee reconstruction. Clin Orthop Relat Res. 2015;473:82–89.PubMedCrossRef Wyles CC, Taunton MJ, Jacobson SR, Tran NV, Sierra RJ, Trousdale RT. Intraoperative angiography provides objective assessment of skin perfusion in complex knee reconstruction. Clin Orthop Relat Res. 2015;473:82–89.PubMedCrossRef
Metadata
Title
The Chitranjan Ranawat Award: Running Subcuticular Closure Enables the Most Robust Perfusion After TKA: A Randomized Clinical Trial
Authors
Cody C. Wyles, BS
Steven R. Jacobson, MD
Matthew T. Houdek, MD
Dirk R. Larson, MS
Michael J. Taunton, MD
Franklin H. Sim, MD
Rafael J. Sierra, MD
Robert T. Trousdale, MD
Publication date
01-01-2016
Publisher
Springer US
Published in
Clinical Orthopaedics and Related Research® / Issue 1/2016
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-015-4209-x

Other articles of this Issue 1/2016

Clinical Orthopaedics and Related Research® 1/2016 Go to the issue