Abstract

Background

Percutaneous biopsy for musculoskeletal tumors commonly relies on imaging adjuncts including ultrasound (US), CT, or MRI. These modalities however have disadvantages (US) or are cumbersome, not universally available, and costly (CT and MRI). US fusion is a novel technique that fuses previously obtained CT or MRI data with real-time US, which allows biopsies to be performed in an US suite. It has proven useful in various body systems but musculoskeletal applications remain scarce. Our goal is to evaluate the fusion technology and determine its ability to diagnose musculoskeletal tumors.

Questions/Purposes

We determined whether biopsies performed via US fusion compared with CT guidance provide equivalent diagnostic yield and accuracy and allow quicker biopsy scheduling and procedure times.

Methods

Forty-seven patients were assigned to undergo either US fusion (with MR, n = 16 or CT, n = 15) or CT-guided biopsies (n = 16). We evaluated adequacy of the histologic specimen (diagnostic yield) and correlation with surgical pathology (diagnostic accuracy). We determined scheduling times and lengths of the biopsy.

Results

US fusion and CT-guided biopsy groups had comparable diagnostic yields (CT = 94%; US/MRI = 94%; US/CT = 93%) and accuracy (CT = 83%; US/MRI = 90%; US/CT = 100%). US fusion biopsies were faster to schedule and perform. All procedures were safe with minimal complications.

Conclusions

US fusion provides a high diagnostic yield and accuracy comparable to CT-guided biopsy while performed in the convenience of an US suite. This may have resulted in the observed faster scheduling and biopsy times.

Level of Evidence

Level II, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Altuntas AO, Slavin J, Smith PJ, Schlict SM, Powell GJ, Ngan S, Toner G, Choong PF. Accuracy of computed tomography guided core needle biopsy of musculoskeletal tumours. ANZ J Surg. 2005;75:187–191.PubMedCrossRef Altuntas AO, Slavin J, Smith PJ, Schlict SM, Powell GJ, Ngan S, Toner G, Choong PF. Accuracy of computed tomography guided core needle biopsy of musculoskeletal tumours. ANZ J Surg. 2005;75:187–191.PubMedCrossRef
2.
go back to reference Cardinal E, Chhem RK, Beauregard CG. Ultrasound-guided interventional procedures in the musculoskeletal system. Radiol Clin North Am. 1998;36:597–604.PubMedCrossRef Cardinal E, Chhem RK, Beauregard CG. Ultrasound-guided interventional procedures in the musculoskeletal system. Radiol Clin North Am. 1998;36:597–604.PubMedCrossRef
3.
go back to reference Chojniak R, Isberner RK, Viana LM, Yu LS, Aita AA, Soares FA. Computed tomography guided needle biopsy: experience from 1,300 procedures. Sao Paulo Med J. 2006;124:10–14.PubMedCrossRef Chojniak R, Isberner RK, Viana LM, Yu LS, Aita AA, Soares FA. Computed tomography guided needle biopsy: experience from 1,300 procedures. Sao Paulo Med J. 2006;124:10–14.PubMedCrossRef
4.
go back to reference Cohen M, Jacob D. [Ultrasound guided interventional radiology] [in French]. J Radiol. 2007;88:1223–1229.PubMedCrossRef Cohen M, Jacob D. [Ultrasound guided interventional radiology] [in French]. J Radiol. 2007;88:1223–1229.PubMedCrossRef
5.
go back to reference Daecke W, Libicher M, Madler U, Rumpf C, Bernd L. [MRI-guided musculoskeletal biopsy] [in German]. Orthopade. 2003;32:170–174.PubMedCrossRef Daecke W, Libicher M, Madler U, Rumpf C, Bernd L. [MRI-guided musculoskeletal biopsy] [in German]. Orthopade. 2003;32:170–174.PubMedCrossRef
6.
go back to reference Dupuy DE, Rosenberg AE, Punyaratabandhu T, Tan MH, Mankin HJ. Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms. AJR Am J Roentgenol. 1998;171:759–762.PubMed Dupuy DE, Rosenberg AE, Punyaratabandhu T, Tan MH, Mankin HJ. Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms. AJR Am J Roentgenol. 1998;171:759–762.PubMed
7.
go back to reference Fraser-Hill MA, Renfrew DL, Hilsenrath PE. Percutaneous needle biopsy of musculoskeletal lesions: 2. Cost-effectiveness. AJR Am J Roentgenol. 1992;158:813–818.PubMed Fraser-Hill MA, Renfrew DL, Hilsenrath PE. Percutaneous needle biopsy of musculoskeletal lesions: 2. Cost-effectiveness. AJR Am J Roentgenol. 1992;158:813–818.PubMed
8.
go back to reference Fuller DB, Jin H. Computed tomography-ultrasound fusion brachytherapy: description and evolution of the technique. Brachytherapy. 2007;6:272–279.PubMedCrossRef Fuller DB, Jin H. Computed tomography-ultrasound fusion brachytherapy: description and evolution of the technique. Brachytherapy. 2007;6:272–279.PubMedCrossRef
9.
go back to reference Fuller DB, Jin H, Koziol JA, Feng AC. CT-ultrasound fusion prostate brachytherapy: a dynamic dosimetry feedback and improvement method. A report of 54 consecutive cases. Brachytherapy. 2005;4:207–216.PubMedCrossRef Fuller DB, Jin H, Koziol JA, Feng AC. CT-ultrasound fusion prostate brachytherapy: a dynamic dosimetry feedback and improvement method. A report of 54 consecutive cases. Brachytherapy. 2005;4:207–216.PubMedCrossRef
10.
go back to reference Gogna A, Peh WC, Munk PL. Image-guided musculoskeletal biopsy. Radiol Clin North Am. 2008;46:455–473, v.PubMedCrossRef Gogna A, Peh WC, Munk PL. Image-guided musculoskeletal biopsy. Radiol Clin North Am. 2008;46:455–473, v.PubMedCrossRef
11.
go back to reference Hakime A, Deschamps F, De Carvalho EG, Teriitehau C, Auperin A, De Baere T. Clinical evaluation of spatial accuracy of a fusion imaging technique combining previously acquired computed tomography and real-time ultrasound for imaging of liver metastases. Cardiovasc Intervent Radiol. 2011;34:338–344.PubMedCrossRef Hakime A, Deschamps F, De Carvalho EG, Teriitehau C, Auperin A, De Baere T. Clinical evaluation of spatial accuracy of a fusion imaging technique combining previously acquired computed tomography and real-time ultrasound for imaging of liver metastases. Cardiovasc Intervent Radiol. 2011;34:338–344.PubMedCrossRef
12.
go back to reference Hau A, Kim I, Kattapuram S, Hornicek FJ, Rosenberg AE, Gebhardt MC, Mankin HJ. Accuracy of CT-guided biopsies in 359 patients with musculoskeletal lesions. Skeletal Radiol. 2002;31:349–353.PubMedCrossRef Hau A, Kim I, Kattapuram S, Hornicek FJ, Rosenberg AE, Gebhardt MC, Mankin HJ. Accuracy of CT-guided biopsies in 359 patients with musculoskeletal lesions. Skeletal Radiol. 2002;31:349–353.PubMedCrossRef
13.
go back to reference Hoang JK, Yoshizumi TT, Toncheva G, Gray L, Gafton AR, Huh BK, Eastwood JD, Lascola CD, Hurwitz LM. Radiation dose exposure for lumbar spine epidural steroid injections: a comparison of conventional fluoroscopy data and CT fluoroscopy techniques. AJR Am J Roentgenol. 2011;197:778–782.PubMedCrossRef Hoang JK, Yoshizumi TT, Toncheva G, Gray L, Gafton AR, Huh BK, Eastwood JD, Lascola CD, Hurwitz LM. Radiation dose exposure for lumbar spine epidural steroid injections: a comparison of conventional fluoroscopy data and CT fluoroscopy techniques. AJR Am J Roentgenol. 2011;197:778–782.PubMedCrossRef
14.
go back to reference Jung EM, Schreyer AG, Schacherer D, Menzel C, Farkas S, Loss M, Feuerbach S, Zorger N, Fellner C. New real-time image fusion technique for characterization of tumor vascularisation and tumor perfusion of liver tumors with contrast-enhanced ultrasound, spiral CT or MRI: first results. Clin Hemorheol Microcirc. 2009;43:57–69.PubMed Jung EM, Schreyer AG, Schacherer D, Menzel C, Farkas S, Loss M, Feuerbach S, Zorger N, Fellner C. New real-time image fusion technique for characterization of tumor vascularisation and tumor perfusion of liver tumors with contrast-enhanced ultrasound, spiral CT or MRI: first results. Clin Hemorheol Microcirc. 2009;43:57–69.PubMed
15.
go back to reference Klauser AS, De Zordo T, Feuchtner GM, Djedovic G, Weiler RB, Faschingbauer R, Schirmer M, Moriggl B. Fusion of real-time US with CT images to guide sacroiliac joint injection in vitro and in vivo. Radiology. 2010;256:547–553.PubMedCrossRef Klauser AS, De Zordo T, Feuchtner GM, Djedovic G, Weiler RB, Faschingbauer R, Schirmer M, Moriggl B. Fusion of real-time US with CT images to guide sacroiliac joint injection in vitro and in vivo. Radiology. 2010;256:547–553.PubMedCrossRef
16.
go back to reference Lindseth F, Kaspersen JH, Ommedal S, Lango T, Bang J, Hokland J, Unsgaard G, Hernes TA. Multimodal image fusion in ultrasound-based neuronavigation: improving overview and interpretation by integrating preoperative MRI with intraoperative 3D ultrasound. Comput Aided Surg. 2003;8:49–69.PubMedCrossRef Lindseth F, Kaspersen JH, Ommedal S, Lango T, Bang J, Hokland J, Unsgaard G, Hernes TA. Multimodal image fusion in ultrasound-based neuronavigation: improving overview and interpretation by integrating preoperative MRI with intraoperative 3D ultrasound. Comput Aided Surg. 2003;8:49–69.PubMedCrossRef
17.
go back to reference Paulson EK, Sheafor DH, Enterline DS, McAdams HP, Yoshizumi TT. CT fluoroscopy-guided interventional procedures: techniques and radiation dose to radiologists. Radiology. 2001;220:161–167.PubMed Paulson EK, Sheafor DH, Enterline DS, McAdams HP, Yoshizumi TT. CT fluoroscopy-guided interventional procedures: techniques and radiation dose to radiologists. Radiology. 2001;220:161–167.PubMed
18.
go back to reference Puri A, Shingade VU, Agarwal MG, Anchan C, Juvekar S, Desai S, Jambhekar NA. CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases. Skeletal Radiol. 2006;35:138–143.PubMedCrossRef Puri A, Shingade VU, Agarwal MG, Anchan C, Juvekar S, Desai S, Jambhekar NA. CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases. Skeletal Radiol. 2006;35:138–143.PubMedCrossRef
19.
go back to reference Rimondi E, Rossi G, Bartalena T, Ciminari R, Alberghini M, Ruggieri P, Errani C, Angelini A, Calabro T, Abati CN, Balladelli A, Tranfaglia C, Mavrogenis AF, Vanel D, Mercuri M. Percutaneous CT-guided biopsy of the musculoskeletal system: results of 2027 cases. Eur J Radiol. 2011;77:34–42.PubMedCrossRef Rimondi E, Rossi G, Bartalena T, Ciminari R, Alberghini M, Ruggieri P, Errani C, Angelini A, Calabro T, Abati CN, Balladelli A, Tranfaglia C, Mavrogenis AF, Vanel D, Mercuri M. Percutaneous CT-guided biopsy of the musculoskeletal system: results of 2027 cases. Eur J Radiol. 2011;77:34–42.PubMedCrossRef
20.
go back to reference Schlaier JR, Warnat J, Dorenbeck U, Proescholdt M, Schebesch KM, Brawanski A. Image fusion of MR images and real-time ultrasonography: evaluation of fusion accuracy combining two commercial instruments, a neuronavigation system and a ultrasound system. Acta Neurochir (Wien). 2004;146:271–276; discussion 276–277.CrossRef Schlaier JR, Warnat J, Dorenbeck U, Proescholdt M, Schebesch KM, Brawanski A. Image fusion of MR images and real-time ultrasonography: evaluation of fusion accuracy combining two commercial instruments, a neuronavigation system and a ultrasound system. Acta Neurochir (Wien). 2004;146:271–276; discussion 276–277.CrossRef
21.
go back to reference Tsukushi S, Nishida Y, Yamada Y, Yoshida M, Ishiguro N. CT-guided needle biopsy for musculoskeletal lesions. Arch Orthop Trauma Surg. 2010;130:699–703.PubMedCrossRef Tsukushi S, Nishida Y, Yamada Y, Yoshida M, Ishiguro N. CT-guided needle biopsy for musculoskeletal lesions. Arch Orthop Trauma Surg. 2010;130:699–703.PubMedCrossRef
22.
go back to reference Wein W, Roper B, Navab N. Automatic registration and fusion of ultrasound with CT for radiotherapy. Med Image Comput Comput Assist Interv. 2005;8:303–311.PubMed Wein W, Roper B, Navab N. Automatic registration and fusion of ultrasound with CT for radiotherapy. Med Image Comput Comput Assist Interv. 2005;8:303–311.PubMed
23.
go back to reference Welker JA, Henshaw RM, Jelinek J, Shmookler BM, Malawer MM. The percutaneous needle biopsy is safe and recommended in the diagnosis of musculoskeletal masses. Cancer. 2000;89:2677–2686.PubMedCrossRef Welker JA, Henshaw RM, Jelinek J, Shmookler BM, Malawer MM. The percutaneous needle biopsy is safe and recommended in the diagnosis of musculoskeletal masses. Cancer. 2000;89:2677–2686.PubMedCrossRef
24.
go back to reference Wendler T, Feuerstein M, Traub J, Lasser T, Vogel J, Daghighian F, Ziegler SI, Navab N. Real-time fusion of ultrasound and gamma probe for navigated localization of liver metastases. Med Image Comput Comput Assist Interv. 2007;10:252–260.PubMed Wendler T, Feuerstein M, Traub J, Lasser T, Vogel J, Daghighian F, Ziegler SI, Navab N. Real-time fusion of ultrasound and gamma probe for navigated localization of liver metastases. Med Image Comput Comput Assist Interv. 2007;10:252–260.PubMed
25.
go back to reference Yao L, Nelson SD, Seeger LL, Eckardt JJ, Eilber FR. Primary musculoskeletal neoplasms: effectiveness of core-needle biopsy. Radiology. 1999;212:682–686.PubMed Yao L, Nelson SD, Seeger LL, Eckardt JJ, Eilber FR. Primary musculoskeletal neoplasms: effectiveness of core-needle biopsy. Radiology. 1999;212:682–686.PubMed
Metadata
Title
2011 Mid-America Orthopaedic Association Dallas B. Phemister Physician in Training Award: Can Musculoskeletal Tumors be Diagnosed with Ultrasound Fusion-Guided Biopsy?
Authors
Jad G. Khalil, MD
Michael P. Mott, MD
Theodore W. Parsons III, MD
Trevor R. Banka, MD
Marnix van Holsbeeck, MD
Publication date
01-08-2012
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 8/2012
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-012-2405-5

Other articles of this Issue 8/2012

Clinical Orthopaedics and Related Research® 8/2012 Go to the issue

Symposium: Disruptions of the Pelvic Ring: An Update

Biographical Sketch: Frank Wild Holdsworth, FRCS (1904–1969)